APC by Schneider Electric – Name – Date InRow SelfContained Systems Rack integrated cooling system for environmentally controlled spaces. The IT Closet in a Box…
Transcript
Page 1: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SelfContained SystemsRack integrated cooling system for environmentally controlled

spaces.

The IT Closet in a Box…

Page 2: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SC Systems Applications

Wiring Closet/ Server Room• Easily deployable

plug and play design• Supplemental cooling for overloaded

comfort system

Up to 7kW

Converted Spaces• Not designed for IT

equipment• Provides dedicated air

conditioning for spaceswithout cooling

Environmentally Controlled Manufacturing Facilities• Manufacturing floor

Data Center Hot Spots• Eliminates need

for overcooling• Isolate heat load

Page 3: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Product/System Overview

InRow SC

NetShelter SX

Configuration 1: Single SC plus NetShelter with Front and Rear Containment(RACSC112/RACSC112E)

Configuration 2: Two SC units plus NetShelter with Rear Containment(RACSC201/RACSC201E)

Configuration 3: Single SC plus NetShelter with Rear Containment(RACSC101/RACSC101E)

Rack Air Containment

Reference APC AN-114

Page 4: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Product / AirflowHeat rejected from condenser coil to

plenum space

Air from plenum space pulled into unit

via condenser fans

Cool air is supplied to row or room

Condenser air absorbs heat from

coil

Heat transferred to condenser coil

Evaporator coil absorbs heat from air

Hot exhaust air from IT equipment pulled

into unit via evaporator fans

Reference APC AN-109

Page 5: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Present the Solution

Row-based Architecture

Provides increased predictability of cooling performance

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.

Predictive failure notification

Maximizes system availability by providing early warning of required fan or filter replacement

Network manageable

View the user interface with a browser. Gives quick access from anywhere on the network

Real time capacity monitoring

Measures how much IT load is being cooled by the unit in real time

Redundant Configuration Available [RACSC201(E)]

Systems can be configured to include an additional InRow cooling unit to provide N+1 or 2N redundancy

Front/Rear Containment Options

Ensures cold supply air and server exhaust air does not mix with room air.

Noise Dampening[RACSC112(E)]

Containment of both front and rear provides reduction of noise caused by Installed equipment

Active Response Controls

Monitors and actively adjust cooling capacity to ensure server inlet temperatures

Page 6: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SC Systems User Interface Design Benefits

Check Log Status Light

Illuminates yellow to notify user at least one new alarm condition exists.

Warning Status Light

Illuminates yellow to notify user of a minor alarm condition

Critical Status Light

Illuminates red when major alarm exists

4-Line Alpha-numeric Display

Provides easy-to-read system status

Common Interface

• Controls common across APC products for intuitive operation

System On Status Light

Illuminates green when system is on

Available Data

• Air conditions, alarm set-points, alarm conditions, current mode of operation, system log

Control Functions

• Cool set-points, alarm set-points, custom input / output contact definitions

Page 7: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Predictive Failure Notification – Maximizes system availability by providing early warning of required fan or filter replacement.

Predictive Failure Notification – Maximizes system availability by providing early warning of required fan or filter replacement.

Active Response Controls – Monitors and actively adjust cooling capacity to ensure server inlet temperatures.

Active Response Controls – Monitors and actively adjust cooling capacity to ensure server inlet temperatures.

Real Time Capacity Monitoring – Measure how much IT load is being cooled by the unit in real time.

Real Time Capacity Monitoring – Measure how much IT load is being cooled by the unit in real time.

InRow SC Systems Management Design Benefits

Page 8: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SC Systems Available Services

Start Up Services Scheduled assembly and start up service for InRow SC unit and Rack Air Containment.

On Site Services An APC factory trained technician will arrive on site to diagnose or repair your APC equipment. Includes two scheduled semiannual preventative maintenance visits.

Preventive Maintenance Services Regular checkups and services can be provided on a monthly, quarterly, or semiannual basis.

Warranty: One year parts only . If Assembly is purchased, warranty changes to one year parts and labor.

Page 9: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SC Systems Options and Related Products

Cable ManagementAccessories designed to organize power or data cables within a rack.

Rack Power DistributionRack-mounted power distribution for networking equipment to high density blade servers.

InfraStruXure CentralCentralized management of your APC network-critical physical infrastructure

Smart UPS Power protection with scalable runtime for IT equipment .

Reference APC AN-115

Page 10: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InRow SC Systems Summary

● No need for refrigerant lines or remote heat exchangers. Self-contained, plug-and-play, design maximize system Agility

● Active Response Controls, network management card, and hot-swappable fans dramatically increase system Availability

● Row-based architecture allows close coupling of IT loads with air conditioning units which increases cooling Predictability

The IT Closet in a Box…

Rack integrated cooling system for environmentally controlled spaces.

Page 11: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Security and Environmental AppliancesProtects against environmental or human physical threats that cause

disruption or downtime to IT assets

NetBotz 200Environmental Monitoring for Network Closets to Data CentersRack-mount monitoring for up to 78 external sensors

NetBotz 300Cost-effective Security and Environmental Monitoring for Network Closets to Data CentersWall-mount monitoring for up to 4 external sensors and 1 camera

NetBotz 400Best Value Security and Environmental Monitoring for Network Closets to Data Centers Wall-mount and rack-mount monitoring for up to 18 external sensors and 2 cameras

Page 12: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

APC NetBotz® Rack Access PX - HID

Protecting IT Assets From Physical Threats

Network appliance enabling remote and local authentication for your NetShelter SX enclosures

Page 13: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Smart-UPS® On-Line

Smart-UPS On-Line

High density, double-conversion on-line power protection with scalable runtime

A versatile UPS developed for the harshest power conditions in the world

Page 14: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Smart-UPS® VT

Compact 3-Phase Power Protection with scalable runtime for small data centers and other business critical applications

Over 10 million currently installed – now available in three phase

Page 15: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Symmetra PX®

Right-sized, modular, scalable 3-phase power protection for any size data center or high density power zone.

Symmetra PX

The right-sized UPS for demanding business critical applications

Ranges: 10-80 kW 25-500 kW

Page 16: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

Switched Rack PDU

Switched Rack PDU

Horizontal Mounting Capabilities

Mount in any 19” rack or enclosure.

Vertical Mounting Capabilities

Occupies zero U of valuable rack space;

optimized to fit in a NetShelter VX

enclosures. Toolless Mounting Capabilities

Quickly and easily mount units in the rear

of the enclosure.

Single Input Power Source

Single branch models bring up to 3.7 kW to

rack. In North America and Japan, multi-branch models

bring 12.5 kW to rack via one strip.

User InterfaceLoad indicator LED,

current monitor, network management

Remote Individual Outlet Control

Turn outlets off that are not in use or recycle power to

locked-up equipment.

Page 17: Lasting+ +centre+de+date+-++12mai2010

APC by Schneider Electric – Name – Date

InfraStruXureTM Central

Available in three appliance platforms: Up to 525 devices, up to 2,025 devices, up to 4,025 devices●Availability

•InfraStruXure Central enables an efficient way for organizations to monitor their company-wide multi-vendor physical infrastructure: power, cooling, security, and environment. Real-time monitoring, user-defined reports and graphs, and instant fault notification and escalation enable quick assessment and resolution of critical infrastructure events that can adversely affect IT system availability.

●Agility•Provides a comprehensive look at how the physical and IT environments operate independently and influence each other, providing critical operating information on power and cooling capacity

•Total Cost of Ownership•The platforms can grow with changing business needs through additional device licenses and add-on surveillance, capacity management and change management modules.

End to end data center infrastructure management software for monitoring and control of power, cooling, security and

energy usage from the building through IT systems

Complete lifecycle, physical location, and connectivity of all data center assets