Page 1: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and
Page 2: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

ContentsC

omm

erci

al

Dom

estic

01

Regulations

Bathroom/ WCKitchen/ Utility Rooms Cooker HoodsWhole house SystemsDomestic/Commercial Inline FansWall and Window fansHeat Recovery Ventilation UnitsCooker HoodsCeiling Sweep FansHand and Hair DryersAir Curtains

AccessoriesWiring diagrams

02

0416263038 404854565860

6470

Page 3: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Ventilation requirements Building RegulationsApproved Document F (2006)

02

The Building Regulations for England and Wales require that all building plans must now provide extract ventilation in every wet room (kitchens, bathrooms, WCs and utility rooms). In Commercial or office buildings alongside the extract ventilation rates for specific rooms there is a minimum air supply rate of 10l/s per person.The required ventilation performance will be achieved by providing the airflow rates set out in Tables 1 & 2. The airflow rates specified are for the performance of the complete installation. Extract ventilation to outside is required in each kitchen, utility room and bathroom and for sanitary accommodation (WCs). The extract can can be either intermittent or continuously operating. The intermittent rate, and for continuous systems the minimum extract airflow rates at the highest and lowest settings, should be no less than specified in Table 1.

The whole dwelling ventilation rate for the supply of air to the habitable rooms in a dwelling should be no less than specified in Table 2.

For current Building Regulations in Scotland check online at www.sbsa.gov.ukFor current Building Regulations in Northern Ireland check online at www.dfpni.gov.uk

Table 1. Extract ventilation rates

Room type Intermittent extract Continuous extract

Minimum rate Minimum Minimum high rate low rate Kitchen 30 l/s (108m3/hr) at hob; or 13 l/s (47m3/hr) Total extract rate should be at least the whole 60 l/s (216m3/hr) elsewhere house or dwelling ventilation rate given in table below Utility room 30 l/s (108m3/hr) 8 l/s (29m3/hr)

Bathroom 15 l/s (54m3/hr) 8 l/s (29m3/hr)

WC or Sanitary 6 l/s (22m3/hr) 6 l/s (22m3/hr) accommodation

Table 2. Whole house or dwelling ventilation rates

Number of bedrooms in dwelling

1 2 3 4 5

Whole house or dwelling 13 17 21 25 29 ventilation rate a,b (l/s) (47m3/hr) (61m3/hr) (76m3/hr) (90m3/hr) (104m3/hr)

Notes: a. In addition, the minimum ventilation rate should not be less than 0.3 l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas.)

b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4 l/s(14.4m3/hr) per occupant.

Page 4: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

03

Ventilation systems

System 1 Background ventilators and intermittent extract (LEV) fans. Guidance on minimum provisions forextract andwhole dwelling ventilation is set out in Table 1. above. (See catalogue pages 4 to 25 for Soler & Palau fans and ventilation products to meet these performance requirements)

System 3 Continuous mechanical extract (MEV). Guidance on (MEV) minimum provisions for extract andwhole dwelling ventilationis set out in Table 2. above.(See catalogue pages 26 to 29 for Soler & Palau fans and ventilation products to meet these performance requirements)

Select one of the following four ventilation systems options:

System 2 Passive stack ventilation (PSV).(PSV) Not offered by Soler & Palau.

System 4 Continuous mechanical supply and extract with(MVHR) heat recovery (MVHR).Guidance on minimum provisions for extract and whole dwelling ventilation is set out in Table 2. above.(See catalogue pages 30 to 33 for Soler & Palau fans and ventilation products to meet these performance requirements)

Installation guidelines

• Site fan as far away as possible from air replacement points.• Site fan close to any source of moisture and high on walls or in ceiling.• Ensure there is adequate air replacement into the room to match the extract performance of the fan or ventilation system. This may require the provision of fresh air vents or an undercut to internal doors.• Avoid siting fans near sources of heat.• To prevent condensation forming in any ductwork, insulate ducting that runs through cold roof spaces.

Page 5: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Bathroom/ WC

04 SILENT Series Range of axial extractors with airflow rates of approx.100 m3/h, for connection to 100 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb noise and vibration and create a very low noise level. All the fans are manufac-tured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, energy-saving motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.Ballrace bearings ensure long life at any mounting angle.

IP45 Water protected

26.5 dB (A) Low noise

8Wconsumption

Energy efficient

Model provided with an elec-tronic humidi-stat which can be adjusted to 60, 70, 80 or

90% HR using a key located on the front grille.Four indicators show the desired level of humidity. The extractor operates automatically when the humidity level in theroom is higher than the set level. The extractor will stop automati-cally when the humidity dropsbelow the selected level and after the selected period set on the ad-justable timer (1 and 30 minutes).

Model provided with a PIR (pas-sive infra-red)detector. The unit starts auto-matically when

a movement is detected within a maximum distance of 4 meters from the fan. They are also fitted with an adjustable “run on” timer, from 1 to 30 minutes, to allow the fan contin-ues operating after the initiation of the movement detection.

SILENT-100 12V must be wired to a safety isolating transformer CT-12/14 which must be located out of the reach of the water spray or person using a bath or shower. The transformer is IP21, class II insulation and protected by fuse. Also available, Transformer CT12/14 R, supplied with adjust-able run-on-timer between 1 to 30 minutes.

Model SELV (Safety Extra Low Voltage). Specially designed to operate within the shower or bath volume with total safety. They are rated 12V, Class III and IP57.

SILENT 100 CZ 12V SILENT 100 CDZ SILENT 100 CHZ VISUAL

Page 6: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Ceiling or wall mounted with discharge directly to the outside or through duct system

Installation examples

05

Bathroom/ WC

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100WBack draft shutter

Fixed shutter and telescopic duct (200-400mm)

Window

Quiet operation

SILENT -100 Usual extractorIn most extract fans the vibration is transmitted to the surrounding areas while in SILENT extractor fans the vibrations are absorbed by acoustic mounting blocks.

Dimensions (mm)

PPa mmcda

40

35

30

25

20

15

10

5

0

4

3,5

3

2,5

2

1,5

1

0,5

0

PPa mmcda

m3/h

m3/sQ

0 20 40 60 80 100

0.00 0.01 0.02

90

80

70

60

50

40

30

20

10

0

9

8

7

6

5

4

3

2

1

0 m3/h

m3/sQ

0 50 100 150 200 250 300

0.00 0.02 0.04 0.05 0.08

Performance curves SILENT100

Models features CZ CRZ CRIZ CHZ CHZ CDZ CZ (12V) CZ CRZ

VISUAL SILVER SILVER

Neon light • • • • • • • Backdraft shutter • • • • • • • • • Timer (1-30min) • • • • * • Automatic timer • Adjustable humidistat • • • PIR • Ball bearings • • • • • • • • Silver colour • • •* Using CT-12/14R transformer • • • •

Technical characteristics Model Speed Abs power Voltage Sound Airflow Insulation Weight

at free (V) pressure at free IP

discharge 50Hz level discharge

(W) (dB(A)) (M3/h) (dB(A)) (kg)

SILENT-100 2400 8 230 26.5 95 II / IP45 0,57

SILENT-100 12V 2320 13 12 26.5 95 / IP57 0,57

Page 7: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Bathroom/ WC

06 SILENT-100DESIGN

Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb vibration and offer a very low noise level. All the fans are manufacturedfrom injection moulded plastic, fitted with automatic shutter and singlephase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.

• Elegant design• Very low noise: 26,5 dB(A)• Low power consumption : 8W• IP 45• Backdraftshutter• Versions with electronic run-o n time r (CRZ) and adjustable humidistat (CHZ)• LED Indicator

Back draft shutter

Motor mounted on “Silent-elastic-block” to prevent vibration and noise transmission

Silent-blocks

To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the prescence of the air

IP45 Water protected

26.5 dB (A) Low noise

8Wconsumption

Energy efficient

Quiet operation

SILENT -100 DESIGN Usual extractorIn most extract fans the vibration is are transmitted to the surrounding areas while in SILENT extractor fans the vibrations are absorbed by acoustic mounting blocks

Page 8: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Technical characteristics Model Max. power Supply Sound Airflow Weight Insulation

at free Voltage pressure at free class /

discharge (V-Hz) level* dB(A) discharge IP

(W) (m3/h) (kg)

SILENT-100 DESIGN 8 230V~50Hz 26,5 80 0,65 II / 45

* Sound presure level measured at 3m at free air conditions

SILENT-100DESIGN

07

Bathroom/ WCModels features

CZ CRZ CHZ CZ SILVER CRZ SILVER CHZ SILVER

LED indicator • • • • • • Backdraft shutter • • • • • • Adjustable Run-On-Timer 1-30mins • • • • Adjustable humidistat • • Ball bearings • • • • • • Silver finish • • •

Dimensions (mm) Performance curve SILENT-100 DESIGN

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100WBack draft shutter

Fixed shutter and telescopic duct (200-400mm)

Window

Page 9: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Bathroom/ WC

08 DECOR -100

Slim line axial flow fans for wall or ceiling installation, designed to remove odours and moisture in small rooms, toilets and bathrooms. The DECOR Series are easy to install, aesthetically pleasing, slim line and extremely quiet The DECOR-100 is available with many different integrated control options to accommodate all applications.

Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diam-eter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon light indicator and single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fans are class II insulation, IP44 rated and suitable to operate with air tempera-tures up to 40oC.

Page 10: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Ceiling or wall mounted with discharge directly to the outside or through duct system

Installation examples

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100WBack draft shutter

Wall kit with fixed or auto-matic shutter

Window Kit

To prevent air entry and limitheat leakage when the extractoris not operating. It opens auto-matically when the fan is activated

Back draft shutter

Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight Insulation

absorbed (V) air flow pressure class / IP

power 50Hz level

(rpm) (W) (m3/h) (dB(A))* (kg)

DECOR-100 2500 13 230 95 40 0,44 / IP44

* Sound pressure level at 1.5m

DECOR -100 09

Bathroom/ WC

Models features C CZ CR CRZ CH CHZ CD CDZ 12V C VISUAL

Neon light indicator • • • • • • • • • Automatic back draft shutter • • • • • • • • • Adjustable Run-On-Timer • • • • • • * Adjustable humidistat • • PIR detector • • Ball bearings • • • •

Dimensions (mm) Performance curve

PPa mmcda

40

35

30

25

20

15

10

5

0

4

3,5

3

2,5

2

1,5

1

0,5

0

PPa mmcda

m3/h

m3/sQ

0 20 40 60 80 100

0.00 0.01 0.02

90

80

70

60

50

40

30

20

10

0

9

8

7

6

5

4

3

2

1

0 m3/h

m3/sQ

0 50 100 150 200 250 300

0.00 0.02 0.04 0.05 0.08

Page 11: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

To prevent air entry and limitheat leakage when the extractoris not operating. It opens due tothe pressure of the air

Back draft shutter Window kit

EDM-100 12V must be wired to a safety isolating transformer CT-12/14 which must be located out of the reach of the water spray or person using a bath or shower. The transformer is IP21, class II insulation and protected by fuse.Also available: Transformer CT12/14 R, supplied with adjustable run-on-timer between 1 to 30 minutes

CT-12/14 transformer

Model SELV (Safety Extra Low Voltage). Specially designed to operate within the shower or bath zone with total safety. They are rated 12V, Class IIIand IP57

EDM-100 12V SEDM-100 12V C

Bathroom/ WC

10 EDM -100

Range of axial extractors with airflow rates of approx. 100 m3/h, for connection to 100 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon light indicator (1) and single single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incor-porate long life motors fitted with ball bearings. All the fans are class II insulation (2), IP44 rated (3) and suitable to operate with air temperature up to 40oC.

(1) Except “S” Basic model(2) H versions: IP40(3) 12V Versions: IP57, class III insulation

EDM -100 12V EDM -100 C

Page 12: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Models features

S T R H C CT CR EC CH M VM VMH 12V S 12V C

Neon pilot light • • • • • • • • • • • • • Fixed period Run-On-Timer • • Adjustable period Run-On-Timer • • • • • * * Automatic shutter • • • • • • • • • • Photoelectric cell • Adjustable humidistat • • • On/off pull cord switch • • • • • Adaptation for glass • • External fixed shutter • • Safety Extra Low Voltage (SELV) • •

* Adjustable Run-On-Timer between 1 and 30 using CT-12/14 T transformer.

Bathroom/ WC

Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight IP

absorbed (V) air flow pressure

power 50Hz level

(rpm) (W) (M3/h) (dB(A))** (kg)

EDM-100 2450 13 230 95 40 0,48 IP44 *

EDM-100S 12V 2100 7 12 85 37 0,48 IP57

EDM-100C 12V 2100 11 12 85 37 0,48 IP57

* H versions: IP40 ** Sound pressure level at 1.5m

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100WBack draft shutter

Wall kit CAR-100Back draft shutter

30

25

20

15

10

5

0

PPa mmcda

3,5

3

2,5

2

1,5

1

0,5

0m3/h

m3/sQ

0 20 40 60 80

0,020,010,00

30

25

20

15

10

5

0

PPa mmcda

3,5

3

2,5

2

1,5

1

0,5

0m3/h

m3/sQ

0 20 40 60 80

0,020,010,00

Performance curve EDM-100

30

25

20

15

10

5

0

PPa mmcda

3,5

3

2,5

2

1,5

1

0,5

0m3/h

m3/sQ

0 20 40 60 80

0,020,010,00

30

25

20

15

10

5

0

PPa mmcda

3,5

3

2,5

2

1,5

1

0,5

0m3/h

m3/sQ

0 20 40 60 80

0,020,010,00

EDM-100 12V

Dimensions (mm)

11

Page 13: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

12 EB -100

Bathroom/ WC

Centrifugal fans suitable for many domestic general ventilation applications where higher system resistance pressures are encountered.The EB models incorporate powerful forward curved centrifugal impeller with single phase 230V50Hz, 2-pole motor Class B insulation are available with a variety of fan function options.

EB-100 S Standard models.EB-100 T Models with adjustable run-on-timer.EB-100 HT Models with internal humidistat and adjustable run-on-timer.

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

MRT-100Circular duct joining piece

A C E

D

B

Dimensions (mm)

EB-100 are fitted with anautomatic back draft shutter toprevent air entry and limit heatleakage when the extractor isnot operating

Back draft shutter

To deliver high airflowperformance with a minimumof noise generation against highstatic pressure system resistance

Forward curvedcentrifugal impeller

140

120

100

80

60

40

20

0

PPa mmcda

14

12

10

8

6

4

2

0m3/h

m3/sQ

0 20 40 60 80

0,0050,000

100 120

0,0150,010 0,0250,020 0,030

PPa mmcda

m3/h

m3/sQ

0 50 100 150 200

0,010,00

250

0,030,02 0,050,04 0,06

280

240

200

160

120

80

40

0

28

24

20

16

12

8

4

0

Performance curveTechnical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP at free (V) at free pressure discharge 50 Hz discharge level (dB(A))

(r.p.m.) (W) (m3/hw) at 1,5 m (kg)

EB-100 2250 30 220-240 110 45,5 1,1 IPX4*

* H version: IPX2

Models features

S T HT

Neon light • • • Backdraft shutter • • • Adjustable Run-On-Timer • • Integral humidistat •

Extract ventila-tion throughthe wall or ceiling

Duct extract ventilation

Installation examples

Page 14: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

13EBB -100 NEBB-100 N extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The range comprises three models, S, T and HT. EBB-N models incorporate powerful forward curved centrifu-gal impeller with 2-speed single phase 230V~50Hz, 2-pole motor.

“S” version: Standard model.“T” version: Model with adjustable run-on-timer.“HT” version: Model with internal humidistat and adjustable run-on-timer.

Models features

S T HT

Backdraft shutter • • • Metal filters • • • Two speed • • • Adjustable Run-On-Timer • • Integral humidistat •

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

MRT-100Circular duct joining piece

REBSingle phase electronic speed controllers

Dimensions (mm)

Performance curveTechnical characteristics Model Speed Maximum Voltage Airflow Sound Weight Insulation

absorbed (V) at free pressure class / IP

power 50Hz discharge level

(rpm) (W) (m3/h) (dB(A))* (kg)

HS 1600 35 130 46 EBB-100 N

LS 1050 15 230

75 34 1.88

/ IP44

* Sound pressure level at 1.5 m

Bathroom/ WC

Duct

Page 15: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

SILENTUB -100In-line axial fan offering a very low noise leveland specifically designed to work through aduct or to be flush mounted into the wall, idealfor ventilating small areas or to exchange heatbetween adjoining rooms. Fitted with singlephase motors 230V-50Hz, IP44, Class II, withball bearings for enhanced working life andassembled on silent-blocks.

Performance curve

SILENTUB -100 is fitted with an automatic back draft shutter to prevent air entry and limit heat leakage when the extractor is not operating

Back draft shutter

Motor mounted on silent-elastic mounting block to absorb vibrations and reduce noise transmissions

Silent mounting blocks

Dimensions (mm)

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100W Back draft shutter

Mounting Foot PIE-100/120Support for wall fixing (accessory)

Bathroom/ WC

14

Bathroom/ WCTechnical characteristics

Model Speed Maximum Voltage Maximum Sound Weight

absorbed (V) air flow pressure

power 50Hz level

(rpm) (W) (m3/h) (dB(A)) (kg)

SILENTUB-100 2450 12 230V 100 37.5 0,5

Page 16: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

MIXVENT -100 KITS

15

Bathroom/ WC

The TD ventilation kits enable the simple andfast installation of a complete ventilationsystem. The kits provide efficient extraction forbathrooms, toilets, washrooms and any otherapplications that require the removal of badodours, stuffy and humid air.3 kits are available:

KIT TD-160/100 N SILENT includes:1 TD-160/100 N SILENT fan+ 4 m of flexible aluminium ducting GSA-100+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA

KIT TD-250/100 includes:1 TD-250/100 fan+ 4 m of flexible aluminium ducting GSA-100+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA

Included:

GSA-100Flexible aluminium ducting

GRA-100Exterior mount grille

BA-50Adhesive aluminium duct tape (10m)

BOR-100Interior circular air valve

Installation and mounting

GRA-100

BOR-100

TD-160/100 N SILENTTD-250/100TD-250/100 T

Bathroom/ WC

WC

Bathroom

Internal WC/Bathroom

KIT TD-250/100T includes:1 TD-250/100 T fan+ 4 m of flexible aluminium ducting GSA+ 1 interior circular air valve BOR-100+ 1 exterior mounted grille GR-100+ 1 adhesive duct tape BA

The TD-250 T extractor is fitted with anadjustable Run-On- Timer between 1 and30 minutes, keeping the fan in operation forthe selected period of time after beingswitched off.

Internal WC/Bathroom

Page 17: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

IP45 Water protected

Kitchen/Utility Room

16 SILENT-200 Range of axial extractors with airflow rates of approx. 180 m3/h, for connection to 125 mm diameter circular ducting.Motor mounted on silent-elastic-blocks which absorb the vibrations and offer a very low noise level. All the fans are manufactured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperatures up to 40oC.The SILENT-200 CZ and CRZ can be supplied with an aesthetic silver front grille.

Technical characteristics Model Speed Abs power Voltage Sound Air flow Insulation Weight

at free (V) pressure at free IP

discharge level discharge

(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)

SILENT-200 2350 16 230 33 180 II / IP45 0,77

* At 3m

Models features CZ CRZ CHZ

Pilot light • • • Backdraft shutter • • • Adjustable Run-On-Timer • • (1-30min) Adjustable humidistat • Ball bearings • • • Silver front grille • •

Page 18: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

17

Kitchen/Utility Room

Dimensions (mm)

0 40 80 120 160

1

2

3

4

5

6

7

8

9

0

10

20

30

40

50

60

70

80

90

0.00 0.01 0.02 0.03 0.04 0.05

0

PPa mmcda

m3/h

m3/sQ

Performance curves SILENT-200

SILENT -200 is fitted with an automatic back draft shutter to prevent air entry

and limit heat leakage when the extractor is not operating

Back draft shutterMotor mounted on acoustic block to absorb vibrations and reduce noise transmissions

Silent-blocks SILENT-200

Accessories

GSA-125Flexible aluminium ducting

GRA-150Exterior mount grille

CX-125Worm drive ducting clip

PER-125WBack draft shutter

Page 19: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Range of axial extractors with airflow rates of approx. 300 m3/h, for connection to 150-160 mm diameter circular ducting.Motor mounted on silent-elastic-blocks (SILENT-300) which absorb the vibrations and offer a very low noise level. All the fans are manufactured from injection moulded plastic, fitted with automatic shutter and single phase 230V-50Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.The SILENT-300 CZ and CRZ can be supplied with an aesthetic silver front grille.

Models features CZ CRZ CHZ CZ PLUS CRZ PLUS CHZ PLUS

Pilot light • • • • • •Backdraft shutter • • • • • •Adjustable Run-On- • • • • Timer (1-30min) Adjustable humidistat • •Ball bearings • • • • • •Silver front grille • •

Technical characteristics Model Speed Abs power Voltage Sound Air flow Insulation Weight

at free (V) pressure at free IP

discharge level discharge

(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)

SILENT-200 1700 29 230 32 280 II / IP45 1,25

SILENT-300 PLUS 2000 17 230 36 320 II / IP45 1,65

* At 3m

Kitchen/Utility Room

18 SILENT-300

REBSingle phase electronic speed controllers

Accessories

GSA-150Flexible aluminium ducting

GRA-150Exterior mount grille

CX-150Worm drive ducting clip

PER-150WBack draft shutter

IP45 Water protected

Page 20: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

SILENT -300 is fitted with an automatic back draft shutter to prevent air entry

and limit heat leakage when the extractor is not operating

Back draft shutterMotor mounted on silent-elastic block to absorb vibrations and reduce noise transmissions

Silent-blocks

Dimensions (mm)Performance curves SILENT-300

19

Kitchen/Utility Room

SILENT-300

Page 21: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

DECOR -200 Range of axial extractors suitable for utility rooms with airflow rates of approx. 180 m3/h, for connection to 120 mm diameter circular ducting.All the fans are manufactured from injection moulded plastic, fitted with neon light indicator and single phase 230V-50Hz, class B motor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fans are class II insulation, IP44 rated and suitable to operate with air temperatures up to 40oC.

40

30

20

10

0

PPa mmcda

m3/h

m3/sQ

0 40 80 120 160 200

0.00 0.01 0.02 0,03 0,04 0,05

4

3

2

1

0

Performance curves DECOR-200

Accessories

GSA-125Flexible aluminium ducting

GRA-150Exterior mount grille

PER-125WBack draft shutter

Dimensions (mm)

Models features C CZ CR CRZ CH

Neon light indicator • • • • • Automatic back draft shutter • • • • • Adjustable Run-On-Timer • • • Adjustable humidistat • Ball bearings • •

Back draft shutter

To prevent air entry and limitheat leakage when the extractoris not operating. It opens due tothe pressure of the air

Technical characteristics Model Speed Maximum Voltage Sound Maximum Weight IP

absorbed (V) pressure air flow

power level

(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)

DECOR-200 2500 20 230 45.5 185 0,8 IP44

* At 1.5m

20

Kitchen/Utility Room

Page 22: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

DECOR - 300 21

Kitchen/Utility Room

Range of axial extractors suitable for kitchens with airflow rates of approx. 280 m3/h, for connection to 150-160 mm diameter circular ducting.All the fans are manufactured from injection moulded plastic and fitted with neon light indicator and single phase 230V-50Hz, class Bmotor equipped with overload thermal protection. The “Z” versions incorporate long life motors fitted with ball bearings. All the fansare class II insulation, IP45 rated and suitable to operate with air temperature up to 40oC.

PPa mmcda

m3/h

m3/sQ

0 60 120 180 240 300

0,080,060,040,020,00

0

7

6

5

4

3

2

110

0

20

30

40

50

60

70

Performance curves DECOR-300Technical characteristics Model Speed Maximum Voltage Sound Maximum Weight IP

absorbed (V) pressure air flow

power level

(rpm) (W) 50Hz (dB(A))* (m3/h) (kg)

DECOR-300 2200 35 230 47 280 1,44 IP44

* At 1.5m

Dimensions (mm)

Models features S C CZ R CR CRZ H CH

Neon light indicator • • • • • • • • Automatic back draft shutter • • • • • Adjustable Run-On-Timer • • • • • Adjustable humidistat • • Ball bearings • •

Back draft shutter

To prevent air entry and limitheat leakage when the extractoris not operating. It is opened bythe pressure of the air flow

Accessories

GSA-150Flexible aluminium ducting

GRA-150Exterior mount grille

PER-150WBack draft shutter

REBSingle phase electronic speed controllers

Page 23: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Ceiling or wall mounted with discharge directly to the outside or through duct system

Installation examples

Kitchen/Utility Room

22 EBB 175EBB 250

The EBB extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The EBB models incorporate powerful forward curved centrifugal impeller with single phase 230V-50Hz, 4-pole (EBB-175) or 2-pole motor (EBB-250).

EBB-175 S and EBB-250 S: Standard models.EBB-175 T and EBB-250 T: Models with adjustable run-on-timer.

Models features S T DV HM Neon light • • • • Back draft shutter • • • • Adjustable Run-On-Timer • 2 speed • Pullcord • Humidstat •

Page 24: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

EBB 175 EBB 250

23

Kitchen/Utility Room

EBB fans are fitted with anautomatic back draft shutter toprevent air entry and limit heatleakage when the extractor isnot operating

Back draft shutter

To deliver high airflowperformances with a minimumof noise generation against highstatic pressure system resistance

Forward curved centrifugal impeller

Performance curves

Technical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP

at free (V) at free pressure

discharge discharge level

(rpm) (W) 50Hz (m3/h) (dB(A))* (kg)

EBB-175 1400 70 230 175 45 2,2 IPX4

EBB-250 1800 125 230 230 52 2,2 IPX4

* At 1.5m

Ceiling or wall mounted with discharge directly to the outside or through duct system

Dimensions (mm) EBB 175 / EBB 250

170

136

7

7

Accessories

GSA-100Flexible aluminium ducting

GRA-70Aluminium exterior grille

CX-80/125Worm drive ducting clip

PER-100WBack draft shutter

Fixed shutter and telescopic duct (200-400mm)

Window

Page 25: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Installation examples

Surface mounted Flush mounted

Kitchen/Utility Room

24 EBB 170NEBB 250N

The EBB-N extractor fans are suitable for many domestic and commercial ventilation applications where higher system resistancepressures are encountered. The range is comprised of EBB-170N and EBB-250N, each available in different versions. The EBB-N models incorporate powerful forward curved centrifugal impeller with 2-speed single phase 230V50Hz, 4-pole motors.

“S” version Standard models.“T” version Models with adjustable run-on-timer.“HT” version Models with internal humidistat and adjustable run-on-timer

Technical characteristics Model Speed Abs. power Voltage Airflow Sound Weight IP

at free (V) at free pressure

discharge discharge level

(rpm) (W) 50Hz (m3/h) (dB(A))* (kg)

EBB-170 N 1010 48 230 220 42,5 3 IP44

EBB-250 N 1225 51 230 270 46 3 IP44

* At 1.5m

Models features S T HT

Back draft shutter • • • Metal filters • • • Two speed • • • Adjustable Run-On-Timer • • Integral humidstat •

Page 26: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

EBB 170NEBB 250N

25

Kitchen/Utility Room

170150

Ø 9

8

284

337

Dimensions (mm) EBB 170 / EBB 250N

Accessories

GSA-100Flexible aluminium ducting

GRA-100Exterior mount grille

MRT-100Circular duct joining piece

REBSingle phase electronic speed controllers

CX-80/125Worm drive ducting clip

Pa mmcda

P

120

110

100

90

80

70

60

50

40

30

20

10

0

12

11

10

9

8

7

6

5

4

3

2

1

0m3/h

m3/sQ

0 40 80 120 160

0,010,00

200 280

0,030,02 0,050,04 0,06

240

0,07

170VL

250VL

170VR

250VR

Performance curves EBB-170 N EBB-250 N

High

High

Low

Low

Page 27: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Cooker Hoods

26 HA-600 SLIMHA-900 SLIM

• Tangential motor/capacitor motor• IIlumination: 2 lamps of 40 W• Professional type metal filters• Frontal, push button, speed selector• Telescopic chimney• Backdraft shutter• Reducer for discharge conduit to 120 mm• Air recirculation through carbon filters• Chrome tray (optional)

Technical characteristics Model Airflow Diameter Motors Speed Voltage Power Current Sound

at free discharge pressure

discharge tube level

(m3/h) (mm) (r.p.m.) (V) (W) (A) (dB(A))*

HA SLIM 700 150 1 3 230 210 0,9 58

* At 1.5m

VERSIONS Stainless / White / BlackHA-600 Slim: 60 cm wideHA-900 Slim: 90 cm wide

Dimensions (mm)

Upper or rear extractionUpper or rear extraction. Easing the outlet installation of smoke and grease

Air recirculation of airCarbon filters allow use of the kitchen hood when the extraction function cannot operate.

Technical characteristics Model Airflow Diameter Voltage Power Absorbed Sound at free discharge current pressure discharge tube level

(m3/h) (mm) (V) (W) (A) (dB (A))

HP-60 300 120 230 130 1,30 47

CEB-60 N 300 120 230 130 1,30 52

GE-350N 300 120 230 130 1,30 51

GET-60NC 230 120 230 180 1,30 45

GET-60NF Plus 525 120 230 205 0,75 65

Page 28: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

27

Cooker Hoods

VERSION: WhiteGE-350N: 56,5 cm wide

Dimensions (mm)

256286565

494

16

149

GE-350 N• Flush fitting• 3 speed• 240 W lamps• Metal filter• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)

GET-60 NC• Hood with telescopic glass extension• 3 speed• Safety switch• Illumination: two 40 W lamps• Metal filter• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)VERSION: White

GET-60NC: 60 cm wide

Dimensions (mm)

20

510

Ø120=

=

280

462

600

280

186

40

30

HP-60600

47084

66

150

495

Dimensions (mm)

• 3 speed• Two 40 W lamps• Metal filter• Backdraft shutter• Upper or rear extraction• Air recirculation through carbon filters (optional/available on request)VERSION: White

HP-60: 60 cm wide

GET-60 NF• Hood with telescopic extension filter• Capacitor motor• 3 speed• Safety switch• Illumination: two 20 W halogen lamps• Metal filters• Backdraft shutter• Upper extraction• Air recirculation through carbon filters (optional/available on request)

VERSION: StainlessGET-60NF PLUS: 60 cm wide

Dimensions (mm)

Page 29: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

28 Extractors Centrifugal extractors manufactured from flameretardant plastic (V0). All extractors are class IIinsulation fitted with centrifugal impeller andsingle phase 230V 50Hz speed controllablemotor. This range consists of three models withairflow ranging up to 625 m3/h.

Metallic Teflon-coated filter

Fitted to the inlet to preventthe build-up of grease withinthe fan and ducting enclosure (CK-40F and CK-60F)

Protection guard

To avoid any contact with theimpeller (CK-25N)

To avoid any contact with theimpeller (CK-25N)

Removeable grease collection tray

CK-60F: 2-speed motor

REGUL-2 speed selector I/II switch to adapt the extractair volume to the needs

All the CK Series extractor parts are easily removable and can be cleaned in the dishwasher.

Easy to dismantle

The efficiency of the kitchen extractors depends on themaintenance and cleaning of the centrifugal impeller.

Cooker Hoods

Page 30: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Dimensions (mm)ØA

E

D

C

G

F

B

Model ØA B C D E F G

CK-25 N 98 34 304 149 218 – 127

CK-40 F 98 42 370 179 266 140 162

CK-60 F 116,5 42 362 180 293,5 145 174

29

To obtain the maximum efficiency of the polluted air extraction, the CK series fans should be installed within a cooker canopy.The airflow required depends upon the canopy width and the distance between the canopy and the cooker. The CK series fans should be installed in vertical position with the grease collection tray at the bottom.

Installation

600

560

520

480

440

400

360

320

280

240

200

160

120

80

40

0

PPa mmcda

m3/h

m3/sQ

0 100 200 300 400 500 600

0 0,025 0,050 0,075 0,1 0,125 0,150 0,175

60

56

52

48

44

40

36

32

28

24

20

16

12

8

4

0

CK-40

CK-25N

CK-60 VR

CK-60 VL

Performance curves SILENT-200

Model features CK-25 N CK-40 F CK-60 F

Grease collection tray • • • Protection guard • Metallic Teflon coated filter • • Removable • • • Washable in a dishwasher • • • Adjustable • • • 2 speed •

Technical characteristics

Model Speed Abs. power Voltage Airflow Sound Weight at free (V) at free pressure discharge 50 Hz discharge level (r.p.m.) (W) (m3/h) (dB(A)) (kg)

CK-25 N 2250 40 230 250 50 1,9

CK-40 F 2350 70 230 360 55 2,7

CK-60 F VR 2475 160 230 625 59 4,7

VL 1740 96 415 54

Canopy size and extractor model recommendations CANOPY RECOMMENDED AIRFLOW EXTRACTION DUCT LENGTH (*)

SIZE (m3/h) 0 to 5 m 5 to 15 m 15 to 30 m

CK-40 F UP TO 60 cm 200-300 CK-25 N CK-35 N CK-50 CK-40 F ECO-500

CK-35 N CK-40 F CK-50 UP TO 90 cm 300-600 CK-40 F CK-50 ECO-500 CK-50 ECO-500 CK-60 F ECO-500 CK-60 F

(*) Expected with an installation with two 90° elbows.

Cooker Hoods

Page 31: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Whole House Systems

30 VENTURIA Extract system ensuring a continuous exhausting of air within residential homes through the extract grilles located in the ‘wet’ rooms (kitchens, toilets, bathrooms, etc) and air inlets located in the main rooms (living room, bedrooms, etc) allowing the input of fresh air.

Equipped with a centrifugal fan and fitted with a two speed, low energy consumption, 230V-50Hz motor, IP44, class B insulation.The Venturia extract system is designed for continuous operation.

Fitted with a two speed switch controlling the maximum airflow

The Venturia extract system ensures the continuous air renewal in residential houses through the extract grilles located in the ‘wet’ rooms (kitchen, toilets, bathrooms) and air inlets located in the main rooms (living room, bedrooms)

Continuous fresh air

Three anti vibration hangingcords enabling to hang the unit in the attic of a house or in false ceilings reducing theradiated noise

Remote location

• 4 exhaust valves of Ø 80 mm for toilets and bathrooms, removable by means of a quarter turn and fitted with two ring clamps allowing a quick and watertight installation of the ducts without tools and clamps. The exhaust valves of Ø 80 mm are regulated automatically: 2 at 15 m3/h and 2 at 30 m3/h.• Exhaust automatically regulated valves for kitchen of Ø 125 mm (45 m3/h and 135 m3/h), with 2 ring clamps for a fast installation.• Discharge port of Ø 125 mm allowing to expel the exhaust air to the outside.• Terminal box fitted• Two plastic covers to blockthe exhaust valves that are notoperating.

Standard version

Technical Model Voltage Power absorbed Absorbed

at free discharge current

(rpm) (W) (A)

VENTURIA-SF 230 65/24 0,3/0,2

Page 32: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

VENTURIA 31

Whole House Systems

3 opening and closing flanges allowing the dismantling of the assembly motor-extractor without the need of disconnecting the ducts and the exhaust valves

Easy maintenance

Performance curves

260

202

266

Ø12531

2

265

Ø125

Ø80

Dimensions (mm)

Technical Model Voltage Power absorbed Absorbed

at free discharge current

(rpm) (W) (A)

VENTURIA-SF 230 65/24 0,3/0,2

Supplied with the VENTURIA Extract system, 2 exhaust valves designed for bathrooms of O 80mm, 1 exhaust valve for kitchens of Ø 125mm and a 2 speed switch

KIT VENTURIA

Accessories

Model Ø mm

Exhaust valve BOAP-80 80 Exhaust valve BOAP-125 125 Switch VMC 2 V

Page 33: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Whole House Systems

32 MINIFAN

MINIFAN is a whole house extract ventilation unit.The range is suitable for different types ofapplications and installations:• Single and multi-dwelling applications.• Either new building or refurbishment.• Small flats to large houses.• Low or high pressure drop systems.

The MINIFAN consists of 2 moulded plasticcomponents secured with clips to ensure perfectairtightness and to facilitate ease of dismantling.The MINIFAN can be installed in many configurations, it can be fixed either on the wall, in a cupboard, under the ceiling or in an attic. The duct work can run in cupboards, false ceilings, lofts, etc.

We recommend the use of our auto regulating valves in conjunction with the casing, to provide the correct rate of extraction and provide an efficient ventilation system.

The MINIFAN whole house ventilator is designed to improve the comfort and hygiene level in the home, with exhaust valves located in wet rooms: kitchen, bathrooms, toilets, etc. Fresh air is introduced through air inlets in the main rooms such as living room and bedrooms.

The MINIFAN is available in 3 standard model performances: LO, ST, HI.Each model is equipped with a 3 speedmotor.

The MINIFAN features:• 4 spigots in 125 mm.• 1 extract spigot in 125 mm.The unit body and fan motor plate are moulded from shock resistant ABS.Fan motor plate is moulded from heat resistant ABS . Highly durable polypropylene clip lock.An external rotor, class B insulation, IP44 protection.MINIFAN is suitable for continuous operation within temperatures of -20oC to +50oC.

Page 34: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

MINIFAN 33

Whole House Systems

271

7183

83

303

326

Ø12

5

Ø125

Ø125

305

Dimensions (mm)

Performance curves

Technical characteristics Model Power supply Current Power Lw in (dB(A))

(A) (W) High speed Medium speed Low speed

MINIFAN LO 230/V~Hz/50Hz 0,29 65 55 * 52 * 43 *

MINIFAN ST 230/V~Hz/50Hz 0,37 80 61 * 56 * 45 *

MINIFAN HI 230/V~Hz/50Hz 0,45 95 62 * 58 * 41 *

* Sound power level radiated with all the spigots connected.

Air flow m3/h Without sleeve With sleeve With claw plasterboard in diameter Sleeve in diameter 125 mm 125 mm for wall installation for ceiling installation

15 BAR 15 BARJ 15 BARP 15

30 BAR 30 BARJ 30 BARP 30

45 BAR 45 BARJ 45 BARP 45

60 BAR 60 BARJ 60 BARP 60

Accessories

BARSelf-adjusting exhaust valves

ROOF OUTLETS Model Version CT 125 P Tulle Tile

CT 125 P Ard Slate

ECASelf-adjusting noise-attenuating Trickle Vent air inlets for installation in joinery elements

Air flow m3/h Model Colour 22 ECA 22 RA* white

30 ECA 30 RA* white

45 ECA 45 RA* white

*Air inlet with acoustic extension piece

Page 35: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Whole House Systems

34 AKOR The Akor Heat Recovery unit provides a balanced ventilation system with air renewal and heat recovery for domestic dwellings. The AKOR heat recovery unit incorporates an efficient cross flow heat exchanger and two direct drive centrifugal fans with 2-speed low power consumption class B, IP44 single phase 230V50Hz motors.

The casing is injection moulded from tough reinforced plastic.

The unit is designed for continuous operation.

Standard Versions

Option 1• 4 circular connection flanges 80 mm diameter for exhaust air from bathrooms, toilets and wet rooms.• 1 circular connection flange 125 mm diameter for exhaust air of the kitchen area.

Option 2

• 1 circular connection flange for exhaust air from bathrooms, WC’s and Utility rooms

Fibreglass thermal insulation Permanent drain to evacuatecondensation water

Easy maintenance and filtercleaning

Plate heat exchanger Efficient cross flow heatexchanger, manufacturedfrom polypropylene plates

All models incorporate inletand discharge circular ductconnection flanges withintegrated air seal

Option 2

Option 1

Page 36: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Technical characteristics Model Voltage Power absorbed Weight at free discharge

(V) (W) (kg)

AKOR-T37 230 115 15

AKOR-GD 230 270 16

* Sound pressure level measured at 1,5m, at the inlet side, in free field.

35

Dimensions (mm)

Connection for condensation drain

Insulation panel

External insulation

FRESH AIR

Interior airto be extracted

INPUT

OUTPUT

Characteristic curves

• Q = Air volume in, m3/hr and m3/s.• Pe = Static pressure in mmWG and Pa.• Dry air at 20oC and 760 mmHg.• Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

80

70

60

50

50 100 150 200 250

Eff

icie

ncy (%

)

Airflow (m3/h)

Heat recovery efficiency

Whole House Systems

Text in

Page 37: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Whole House Systems

36 AKOR

Air flow m3/h Without sleeve With sleeve With claw plasterboard in diameter Sleeve in diameter 125 mm 125 mm for wall installation for ceiling installation

15 BAR 15 BARJ 15 BARP 15

30 BAR 30 BARJ 30 BARP 30

45 BAR 45 BARJ 45 BARP 45

60 BAR 60 BARJ 60 BARP 60

Accessories

BARSelf-adjusting exhaust valves

ROOF OUTLETS Model Version CT 125 P Tulle Tile

CT 125 P Ard Slate

ECASelf-adjusting noise-attenuating Trickle Vent air inlets for installation in joinery elements

Air flow m3/h Model Colour 22 ECA 22 RA* white

30 ECA 30 RA* white

45 ECA 45 RA* white

*Air inlet with acoustic extension piece

Page 38: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Whole House Systems

37

Accessories

Model Diameter (mm) ABE-150/0.5M 150

CD intake grilleDesigned to introduce air into individual houses. It can be installed on a wall, ceiling or on straight or inclined ceiling tiles. Diam-eter 60 mm

BOAP/BOAC plastic extract grill

ABE defrosting unitPrevents the formation of ice from the con-densation on the interchanger plates in the air extract. Made from galvanized steel plate and supplied with polyethylene clips. It has a heat resistance of 500W and control thermostats.

ABE heating unitAllows the temperature of the blown air to be increased. It has a 500W power heating element and control thermostats.

Air inlet forfalse ceilingmounting

Air inlet, wall- mounted

Model Diameter (mm) BOAP 80 80

BOAC 80 80

BOAP 125 125

BOAC 125 125

Sound attenuatorLA 80LA 125

MRT Plastic connection for connecting 2 ducts of the same diameter

Model Diameter (mm) MRT 60 P 80

MRT 80 P 80

MRT 125 P 125 MRT 150 P 150

Duct fittings

Diameters Model A (mm) B (mm) C (mm) D (mm)

DERIV 80-80 P 80 80 80 DERIV 125-60-60-125 P 125 60 60 125 DERIV 125-60-60-60 P 125 60 60 60 DERIV 150-125-125 P 150 125 125

DERIV 150-60-60-125 P 150 60 60 125

Model Diameter (mm) ABE-150/0.5M 150

CT-150 extract roof cowl

Model Diameter (mm) CT 150P TILE 150

CT 150P SLATE 150

GP ISO insulated flexible duct

Model Diameter (mm) GP ISO 60 60

GP ISO 80 80

GP ISO 125 125

GP ISO 125 125

AKOR Plenum10 inlet spigots in 60 mm diameter.Outlet spigot in 150 mm diameter.5 covers.

AKOR switch(Extract/Input)2 extract positions with stop2 input positions with stop

Page 39: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

38 TD-ECOWATT Series

Range of Low Profile Mixed flow fans with ball bearings and brushless DC motors, of high efficiency and low powerconsumption. Manufactured in plastic with a removable fan body, and rated as standard 90/260V-50/60Hz,IP44, speed controllable from 10% to 100%. Specially suitable for any kind of ventilationapplication, where the fan must operate continuously allowing a significant energy saving, or on those requiring a Demand Controlled Ventilaton System involving the use of other sensors or controls

The unique design of the sup-port bracket allows the motor and impeller assembly to be fitted or removed without dis-mantling the adjacent ducting

Easy maintainance

The low profile of the TD-ECOWATT fans makes them the most effective solution for installations where the space for installation is limited such as false ceilings.

Low profile

ClassicCentrifugal

CentrífugalIn-line

Ventilationcabinet

Mixed flowTD-ECOWATT

Design characteristics

160 250 350 500 800

Plastic housing • • • • • Plastic impeller • • • • • Insulation Class II II II II II

Non self resetable • • • • • thermal protection

Ball bearings • • • • •

Dimensions (mm)

303

188

176

97

100

80

9060

115

Domestic/ CommercialInline fans

Page 40: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

TDM Series 39

Domestic/ CommercialInline fans

Place the impeller and motorFix the support bracket

Easy to mount

Connect the ductsCarry out the wiring connections

Technical characteristics Speed Maximum Maximum Airflow Maximum Sound Ø Weight power absorbed at free operating pressure Duct absorbed current discharge temperature level*

TD-MIXVENT (r.p.m.) (W) (A) (m3/h) (°C) (dB(A)) (mm) (kg)

TD-160/100 ECOWATT 2650 10 0,07 190 60 34 100 1,4

TD-250/100 ECOWATT 2400 22 0,17 275 60 35 100 2,0

TD-350/125 ECOWATT 2420 22 0,17 360 60 34 125 2,0

TD-500/150 ECOWATT 2600 48 0,35 580 60 36 150 2,7

TD-800/200 ECOWATT 2360 105 0,75 1030 60 38 200 4,9

Performance curves

– Q = Air volume in, m3/hr and m3/s.– Pe = Static pressure in mmWG and Pa.– Dry air at 20oC and 760 mmHg.– Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, Part 1; AMCA 210-85 and ASHRAE 51-1985.

Page 41: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Elegant design harmonises with any environment

40 HV STYLVENT Series

Complete range of axial flow fans for wall or window mounting applications. All the fans are supplied with tough ABS plastic grilles, shutter and single phase 230V- 50Hz motor. All the fans are class II insulation and IPX4 rated.The HV-STYLVENT series comprises 3 diameters: 150, 230 and 300 mm, including several operating options, making them ideallysuited for a wide range of general, commercial exhaust or supply ventilation applications.

To prevent air entry and prevent heat leakage when the extractor is not operating

Shutter

Extract or Supply operation

Reversible

CommercialWall/ Window

Page 42: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

HV STYLVENT Series

41

HV-M versions Manually operated models via integral pull cord

• Single speed (HV-150M) or 2-speed (HV-230M and 300M) operation• Model 230 and 300 are reversible• Natural ventilation position (shutter open, fan off - except HV-150M)• Neon lights indicating the mode of operation

HV-150 M 2 Positions: Fan OFF, shutter closed Fan ON, working as air extract with shutter openHV-230 M 5 Positions:

HV-300 M 1 Fan stopped and shutter closed 2 Fan on high speed working as air extract with shutter open 3 Fan on low speed working as air extract with shutter open 4 Fan stopped and shutter open 5 Fan in reverse high speed supplying air in the room with shutter open

HV-A versions Automatic models operated via control unit CR

• Single speed (HV-150A) or 2-speed (HV-230A and 300A) operation• Model 230 and 300 are reversible• Natural ventilation position (shutter open, fan off)• Neon lights indicating the mode of operation

HV-150 A 3 Positions: Fan OFF, shutter closed Fan OFF, shutter open Fan ON, working as air extract

To operate all these functions use the accessory CR-150HV-230 A 5 Positions:

HV-300 A 1 Fan stopped and shutter closed 2 Fan on high speed working as air extract with shutter open 3 Fan on low speed working as air extract with shutter open 4 Fan stopped and shutter open 5 Fan in reverse high speed supplying air in the room with shutter open To operate all these functions use the accessory CR-300

Standard range

• Single-phase motor 230V50Hz with thermal overload protection• Single speed operation• Class II insulation• Model 230 and 300 are reversible with CR-150 control accessory• Automatic, thermally actuated shutter

HV-150 AE 2 Positions: OFF - Fan OFF, shutter closed ON - fan ON, working as air extract with shutter openHV-230 AE 3 positions (with CR-150 control accessory)

HV-300 AE OFF - Fan OFF/Shutter closed ON - Fan ON/shutter open Fan working as air extract/supplying air

REB-1R control Speed controller including a switch to reverse the airflow direction

HV-AE versions

CommercialWall/ Window

Page 43: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

42 HV STYLVENT Series

Radio control range• Two speed operation• Natural ventilation position• All model are reversible• Automatic, thermally actuated shutter• Neon light mode of operation indication

HV-230 RC 6 Positions:

HV-300 RC 1 Fan stopped and shutter open 2 Fan stopped and shutter closed 3 Fan on high speed working as air extract with shutter open 4 Fan on reverse high speed supplying air in the room with shutter open 5 Fan on low speed working as air extract with shutter open 6 Fan in reverse low speed supplying air in the room with shutter open

HV-RC versions

Flush mounted version

HVE-230 AE 3 same positions as HV-230 AEHVE-230 A 5 same positions as HV-230 AHVE-230 RC 6 same positions as HV-230 RC

HVE versions

STYLVENT Product Summary – Operational Specifications

Model Flush Single Two Natural Pull Electrical accessories

Radio

mounted speed speed Reversible ventilation cord REB-1R CR-150 CR-300 control

HV-150 M • • HV-230 M • • • • HV-300 M • • • • HV-150 AE • • HV-230 AE • • • HV-300 AE • • • HV-150 A • • • HV-230 A • • • • HV-300 A • • • • HV-230 RC • • • • HV-300 RC • • • • HVE-230 AE • • • • HVE-230 A • • • • • HVE-230 RC • • • • • Maximum ambient operating temperature for all models: 45oC. One remote control can operate several HV.RC. In that case, the fans must be installed with a minimum distance of 1,5 meters between fans.

CommercialWall/ Window

Page 44: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Technical characteristics Model Speed Maximum Maximum Airflow rate (m3/h) SPL* at 3 m Weight

absorbed absorbed Extraction (dB(A))

power

current

High Low Intake High Low

(rpm) (W) (A) speed speed speed speed (kg)

HV-150 AE 1800 32 0,19 225 - - 39 - 2,0

HV-150 M 1800 32 0,19 225 - - 39 - 2,0

HV-150 A 1800 32 0,19 225 - - 39 - 2,0

HV-230 AE 1250 34 0,15 600 - 330 43 - 3,5

HVE-230 AE 1250 34 0,15 600 - 330 43 - 3,5

HV-230 M 1250 34 0,15 600 450 330 43 37 3,5

HV-230 A 1250 34 0,15 600 450 330 43 37 3,5

HVE-230 A 1250 34 0,15 600 450 330 43 37 3,5

HV-230 RC 1250 34 0,15 600 450 330 43 37 3,5

HVE-230 RC 1250 34 0,15 600 450 330 43 37 3,5

HV-300 AE 1150 68 0,30 1100 - 700 46 - 5,1

HV-300 M 1150 68 0,30 1100 750 700 46 38 5,1

HV-300 A 1150 68 0,30 1100 750 700 46 38 5,1

HV-300 RC 1150 68 0,30 1100 750 700 46 38 5,1

* SPL: Sound Pressure Level measured at 3 m.

G

F

B

C

E

Ø D

A

H

(no vidro)

Dimensions (mm) Model A B C ø D E F G H

Min Max Min Max Min Min

HV-150 230 251 109 187 190 3 25 22 160 150

HV-230 300 325 142 259 262 3 25 22 200 185

HV-300 368 403 150 327 330 3 25 22 230 220

163

173 182356

326

367

337

Dimensions of the HVE “flush mounted” version

CommercialWall/ Window

43

Page 45: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CommercialWall/ Window

44

Stage 1 External grilleOnce in position, the external grille is held bythree rubber plugs which allow the installer toassemble the interior section of the fan.

Installation in glass or panels from 3 to 25 mm thickness

Stage 2 Support frameTo enable easy mounting of the support frame, the holes are tapered and the fixing screws can be located depending on the glass/panel thickness:

3 mm< thickness<10 mm

10 mm<thickness<25 mm

Stage 3 Internal grilleFinally, place the lugs on the top of the support frame into the rectangular slots on the front grilleit into position.

The STYLVENT series of fans are designed for speed of installation in three easy stages.

For a wall mounted installation it is necessary to use the extended threaded rod set (see Installation Accessories) Installation on walls from 25 to 300 mm thick

Before installation, rods must be cut to 5mm less than the thickness of the wall. Cut a hole in the wall in accordance with the dimensions shown in the table (to right). Ensure that internal wall mounting surface is as smooth as possible.

On the interior of the wall, mark the fixing hole positions using the support plate as a template.

Fit the threaded rods to the external guard usingthe threaded sleeves. Place the external grille into position and hold in place with the rubber plugs.

Then, the installation follows the same stages as in the glass installation except for the supportframe installation, which has to be fixed using 2 or 4 screws (HV-150, HV-230 and HV-300 models respectively).

H

L

Ø D

Model ø D

Min Max H* L*

HV-150 187 190 117 121

HV-230 259 262 152 165

HV-300 327 330 322,5 357,3

* There are only two diagonal fixing holes for model HV-150

Page 46: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

HV STYLVENT Series

45

CommercialWall/ Window

Threaded Rod setThreaded rods and sleeves for use when installing the HV fanson walls from 25 mm up to 300 mm thick

Installation accessories

Accessories

CR-150Control unit for HV-150 AFitted with:• On/off switch for fan operation. ( - )• On/Off switch for shutter operation• One single CR-150 unit can operate up to 5 HV-150 fans.

CR-300Control unit for HV-230 A,HV-300 A and HVE-230 A Fitted with:• A selector for the different modes of fan operation (0,••,•, )• A reversing switch to change the airflow direction ( , )• One single CR-300 unit can operate up to 5 HV-230 or 300 fans.

REB-1RSpeed controller including a switch to reverse the airflow direction.Only to be used with models HV-230 AE, HV-300 AE andHVE-230 AE Max 1A.

Connection cableA (7) core wire cable for the connec-tion of models HV-230 A andHV-300 A to the remote control unit CR-300. (Supplied on 10m rolls as standard)

Model Electrical supply IP Power Maximum Class Temperature Dimensions Frequency Voltage protection current (mm)

(Hz) (V) (VA) (A) L A H

REB-1R 50 220-240 IP-40 400 1 II ( ) 0-40°C 160 58 88

Control Unit CR-150 88 47 88

Control Unit CR-300 158 57 88

Page 47: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CommercialWall/ Window

46 HCM-N Series Range of axial flow fans designed to exhaust air directly to the outside. All the fans are manufactured from injection moulded plastic and fitted with automatic shutter and single phase 230V-50Hz, class B motor. All the fans are class II insulation and IPX4 rated.

Overpressure shutter

External shutter

Guards fitted at the inlet andoutlet of the fan to prevent the entry of any foreign objects

Safety guards

Installation

Mounting in glassMaximum diameter (3 to 6 mm)Cut hole diameter (mm)HCM-150 N 183 to 188HCM-180 N 220 to 225HCM-225 N 262 to 267

Mounting in wallsCut hole diameter (mm)HCM-150 N 183 to 188HCM-180 N 220 to 225HCM-225 N 262 to 267

Easy installationIn glass use two screws to fix the inner fan assembly to the outer part.For wall mounted installation using 4 screws to fix the winner fan assembly directly on the wall.

Page 48: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

HCM-N Series 47

CommercialWall/ Window

Model ØA ØB C D E F

HCM-150 N 214 174 60 88 35 98

HCM-180 N 255 205 86 120 35 135

HCM-225 N 298 248 89 119 35 125

C

D

E

F

Ø B

Ø A

Dimensions (mm) Technical characteristics Model Speed Maximum Voltage Maximum Sound Weight

absorbed (V) airflow pressure

power 50 Hz level*

(r.p.m.) (W) (m3/h) (dB(A)) (kg)

HCM-150 N 1900 25 230 400 40 0,9

HCM-180 N 2000 24,8 230 600 41 1,7

HCM-225 N 1700 40 230 900 45 1,8

* Sound pressure level measured at 1,5m, at the inlet side, in free field.

Page 49: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

48 CADB-SSlimline Range of heat recovery units mounted with double skin galvanised sheet steel panels and internally lined with fireproof (M0) fibreglass insulation. They are supplied with a cross flow heat exchanger made of Aluminium with a maximum efficiency of 60%.

All models incorporate single phase direct drive forward curved centrifugal fans, an external IP55 terminal box and are supplied with four mounting feet with antivibration mounts to facilitate the installation and reduce noise transmission.

All models are fitted with inlet and discharge circular duct connection flanges with integrated rubber air seal.Supplied with two G4 grade filters.

MotorsCADB-010 2 speeds, Class B insulation, IP44.CADB-020 Speed controllable by voltage, Class F insulation, IP55. Electrical supply: Single phase 230V 50Hz.

Additional information Heat exchanger removable from the top panel. Filters removable from side panels.

Double skin galvanised sheet steel panels and internally lined with 25 mm thickness of fireproof (M0) fibreglass insulation

Low noise level

Anti-vibration mounts toreduce vibration and noisetransmission to the installation

Air tightness High efficiency filters

All models incorporate inletand discharge circular ductconnection flanges withintegrated rubber air seal

Two G4 grade filters, 90%efficiency and M3 fireresistance

CommercialHeat Recovery

Page 50: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CADB-S 49

CommercialHeat Recovery

All models are supplied withfour mounting feet to facilitate installation

Easy to mount

Permanent drain to removewcondensation water

Condensation drain

IP55 external terminal box

External weatherproof terminal box

Dimensions (mm)

Technical characteristics Model Fan Speed Motor Maximum Maximum Weight type power current drawn flow at 230V (r.p.m.) (W) (A) (m3/h) (kg)

CADB S 010 7/7 1100 2 x 184 2 x 1,5 1200 100

CADB S 020 9/9 1320 2 x 550 2 x 5,5 2000 130

CADB S 010 CADB S 020

A 1030 1100 B 950 1030 C 470 570 Ø D 315 400 E 230 260 F 245 290 G 1120 1220 H 1050 1120

J 970 1050

Characteristic curves The graphs are valid for air density of 1.2 kg/m 3 , with the tubing apparatus for intake and outtake.

Level of acoustic pressure measured in open field at 4m. Intake tubing. Lp in dB (A).

Level of acoustic power radiated at the intake duct. Lw in dB (A).

Level of acoustic power radiated at the outlet duct. Lw in dB (A).

Page 51: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CommercialHeat Recovery

50 CADB-SAccessories

ABEElectric heater batteriesOperationsDefrosting operation: To heat the outside fresh air before going through the heat recovery unit to avoid frost accumulation and sealing of the heat exchanger.Post heating operation: To increase the temperature of the supply air, after the heat exchanger.

AccessoriesKAAFlexible coupling

AFL AND AFR Filters

Electrical accessories

APCDischarge protection guards

Model Screen CADB S 010 APC-135

CADB S 020 APC-400

Model Frame support Spare +Filter Filter CADB S 010 AFL-010 AFR-010

CADB S 020 AFL-020 AFR-020

Model Flexible coupling CADB S 010 KAA-315

CADB S 020 KAA-400

PULSER controllerElectronic controller to regulate the heat outputfor single phase or two phase (200 - 415 V)electric heater battery in order to maintaina constant pre-selected temperature.Depending on the selected temperature, thecontroller pulses the entire power outputand uses a time-proportional control tomaintain that temperature.

PULSER-ADDSupplementary unit for slave control fromanother PULSER to control batteries withpower ratings superior to the PULSER capacity(3600W-230V).superior to the PULSERcapacity (3600W-230V).- Post heating operation: To increase the temperature of the supply air, after the heat exchanger.

TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.

Electrical heater battery accessoriesTo control the heater batteries.

DEFROSTING OPERATION POST HEATING OPERATION* Heat recovery Supply Diameter Power Heater Controller Duct External Controller Duct External Model (mm) (kW) type sensor potentiometer sensor potentiometer

CADB S 010 1~230V 315 3 ABE 315/3M PULSER TGK 310 TBI 10 PULSER TGK 330 TBI 30

CADB S 020 1~230V 400 5 ABE 400/5M PULSER + TGK 310 TBI 10 PULSER + TGK 330 TBI 30

PULSER ADD PULSER ADD

* Other control configurations are possible

Page 52: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

51

CommercialHeat Recovery

TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.

PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.

TB-10Potentiometer mounted on the main board panel for setting temperature between -20 and +10oC. Used with the Pulser and a TGK-310 duct sensor to set the minimum air temperature before entering in the heat exchanger.

COM-2Speed switch for CADB S 010.

REB-10Single phase electronic speed controller for CADB S 020.

TB-30Potentiometer mounted on the main board panel for setting temperature between 0 and +30oC. Used with the Pulser and with a TGK-330 duct sensor to set the air temperature after the electric battery in post heating operation.

Acoustic accessories

SILSound attenuators to mount at the inlet and/or discharge of the heat recovery units

ØA ØB C D dB Attenuation

Model Attenuator (mm) (mm) (mm) (mm) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

CADB S 010 SIL 315 315 400 700 860 2 2,2 3,3 9 21,2 7,6 4,1 5,5

CADB S 020 SIL 400 400 500 700 860 1,8 3,1 4 9,5 13,7 5,6 0,4 5,9

Page 53: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CommercialVentilation

52 CADB-S Accessories

Model Frame Support Spare + Filter Filter

CADB S 010 AFL-010 AFR-010

CADB S 020 AFL-020 AFR-020

Mounting accessories

Electrical accessories: Electric heater batteries The heater battery operation must be enslaving to the fan operation. The installation must include a pressure switch to switch off the electric heater battery supplies in case of fan failure.ABEElectric heater batteriesOperations• Defrosting operation: To heat the outside fresh air before going through the heat recovery unit to avoid frost accumulation and sealing of the heat exchanger.• Post heating operation: To increase the temperature of the supply air, after the heat exchanger.

Electrical heater battery accessoriesTo control the heater batteries.

AFL and AFR Filters

Model Flexible coupling

CADB S 010 KAA-315

CADB S 020 KAA-400

KAAFlexible coupling

APCDischarge protection guards

Model Screen

CADB S 010 APC-315

CADB S 020 APC-400

PULSER controllerElectronic controller to regulate the heat outputfor single phase or two phase (200 - 415 V)electric heater battery in order to maintaina constant pre-selected temperature.Depending on the selected temperature, thecontroller pulses the entire power outputand uses a time-proportional control tomaintain that temperature.PULSER-ADDSupplementary unit for slave control fromanother PULSER to control batteries withpower ratings superior to the PULSER capacity(3600W-230V).superior to the PULSERcapacity (3600W-230V).

TG- K310, TG-K330 and TG-K360Duct temperature sensor.Temperature range:TG-K310 from -20 to 10oC.TG-K330 from 0 to 30oC.

DEFROSTING OPERATION POST HEATING OPERATION* Heat recovery Supply Diameter Power Heater Controller Duct External Controller Duct External Model (mm) (kW) type sensor potentiometer sensor potentiometer

CADB S 010 1~230V 315 3 ABE 315/3M PULSER TGK 310 TBI 10 PULSER TGK 330 TBI 30

CADB S 020 1~230V 400 5 ABE 400/5M PULSER + TGK 310 TBI 10 PULSER + TGK 330 TBI 30

PULSER ADD PULSER ADD

* Other control configurations are possible

Page 54: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CADB-S Accessories

53

CommercialVentilation

Acoustic accessories

TBI-10Potentiometer mounted on the main board panel for set-ting temperature between -20 and +10oC. Used with the Pulser and a TGK-310 duct sensor to set the minimum air temperature before entering in the heat exchanger.

4.30 PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.

REB-10Potentiometer mounted on the main board panel for setting temperature between 0 and +30oC. Used with the Pulser and with a TGK-330 duct sensor to set the air temperature after the electric battery in post heating operation.

4.30 PRESSURE SWITCHDifferential pressure switch to control the fan running and the filter clogging up.Working pressure range from 40 to 300 Pa.

COM-2Speed switch for CADB S 010.

SILSound attenuators to mount at the inlet and/or discharge of the heat recovery units

ØA ØB C D dB Attenuation

Model Attenuator (mm) (mm) (mm) (mm) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

CADB S 010 SIL 315 315 400 700 860 2 2,2 3,3 9 21,2 7,6 4,1 5,5

CADB S 020 SIL 400 400 500 700 860 1,8 3,1 4 9,5 13,7 5,6 0,4 5,9

Page 55: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CommercialVentilationCooker Hoods

54 HS-600/900 • Decorative cooker hoods without motor• Illumination: two 40 W lamps• Professional type metal filters• Fan system speed controllable• Telescopic chimney

Fitted with control panel to adjust the speed of the fan.

Versions Stainless

HS-600 60 cm wide

HS-900 90 cm wide

Dimensions (mm)

Page 56: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

GAR-190/150Flexible alumin-ium 190 x150 mm ducting with circular ends.3m long.

BA-50Aluminium adhesive connection tape to fix the accessories for theremote extraction installation.5 m long.

Flange-200Circular duct coupling. For fans CKB-800

Mixed flow in-line fan, type TD-800/200 N with an airflow performance of 800 m3/h.Speed controllable from the cooker hood and designed to be installed at any point of the duct.

55

CommercialVentilationCooker Hoods

Centrifugal roof extract fan with an airflowperformance of 800 m3/h. Controllable from the cooker hood and designed for roof mounted installations either in buildings or in houses.

Model Airflow Diameter Voltage Power Sound at free discharge pressure discharge tube level (m3/h) (mm) (V) (W) (dB (A))

TD-800 800 200 230 140 45

TH-800 800 200 230 140 52

Cooker hood without motor

Extractor fan

Cooker hood without motor

Extractor fan

Roof-mounted fan systemIn-Line fan system

TD-800

A canopy hood, with filter and controls, with a remote mounted duct fan provides enormous flexibility of installation.

A canopy hood, with filter and controls, with a remote mounted duct fan provides enormous flexibility of installation.

TH-800

Mounting Kit “H”To ease the installation of the decorative cooker hoods HS-600 and HS-900 regardless of the fan, a mounting kit with the required accessories is shown below:

Page 57: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

56 HTB N STANDARD Series

High performance ceiling fans, silent, easy to install, three-speed control included.80, 100 and 140 cm diameter models.IP44, class B.

CommercialVentilationSweep Fans

Includes: three-speed control.Dimensions LxWxH (mm):68x42x113

ØA

ØB

D

C

ØEDimensions (mm)

Technical characteristics Voltage Power N° Maximum Air Sound Thermal Colour Speed control Weight 50Hz speeds speed flow pressure fuse switch level

Model (V) (W) (r.p.m.) (m3/h) (dB(A)) (Kg)

HTB-75 N 230 45 3 280 6.400 45 • White Included 4,8

HTB-90 N 230 60 3 240 8.650 46 • White Included 5,2

HTB-150 N 230 75 3 220 12.600 47 • White Included 8,2

Model Ø A Ø B C D

HTB-75 N 800 175 395 210

HTB-90 N 1000 175 395 210

HTB-150 N 1405 195 410 210

Page 58: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

HTS STANDARD Series

57

CommercialVentilationSweep Fans

Silent ceiling fans, easy to install, metal bladesand body, three-speed control included.90 and 40 cm diameter models. Available inwhite colour paint or chromed finish type (CR).IP44, class B.

ØEDimensions (mm)

Includes; three-speed control.Dimensions LxWxH (mm):68x42x113

Technical characteristics

Voltage Power N° Maximum Air Sound Thermal Colour Speed control Weight 50Hz speeds speed flow pressure fuse switch level

Model (V) (W) (r.p.m.) (m3/h) (dB(A)) (Kg)

HTS-90 230 45 3 380 4.000 45 • White Included 5,2

HTS-140 230 50 3 226 6.000 46 • White Included 5,5

HTS-90 CR 230 45 3 380 4.000 45 • Chrome Included 5,2

HTS-140 CR 230 50 3 226 6.000 46 • Chrome Included 5,5

Model Ø A Ø B C D

HTS-90 905 175 395 210

HTS-140 1387 175 395 210

HTS-90 CR 905 175 395 210

HTS-140 CR 1387 175 395 210

Page 59: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Commercial Hand & Hair Dryers

58 SL Series S&P warm air hand dryers protected against vertical water splash.Fitted with thermal overload protection in the motor and the heating element. Motor Class II (*).(*) Aluminium and 2500 models, Class I

Technical characteristics Model Maximum Voltage Maximum Sound Weight Dimensions Casing On Off Colour

power (V) airflow pressure LxAxH material

absorbed level

(W) 50 Hz (m3/h) (dB(A)) (kg) (mm)

SL-2002 Automatic 1875 230 170 52 2.8 230x145x332 Polycarbonate Infra-red when hands are removed White

SL-2002 A Silver 1875 230 170 52 2.8 230x145x332 Polycarbonate Infra-red when hands are removed Silver

SL-2002 Aluminium 1875 230 170 52 3.8 230x145x332 Aluminium Infra-red when hands are removed White

SL-2002 1875 230 170 52 2.8 230x145x332 Polycarbonate Push button Run-On-Timer 45s White

SL-2500 2600 230 280 55 10 330x190x265 Aluminium Push button Run-On-Timer 50s White

Easy installation

SL-2002 A SILVER SL-2002 AUTOMATIC ALUMINIUM

SL-2002 AUTOMATIC SL-2002

SL-2500

SL-2002 AUTOMATIC / SL-2002 A SILVER

Automatic activation by means of an infrared

sensor • The unit switches off when the hands

are removed • Polycarbonate casing • Safety cut

out device to avoid continued function if exhaust

is blocked.

White (SL-2002 AUTOMATIC)

or SL-2002 A SILVER.

SL-2002 AUTOMATIC ALUMINIUM

Automatic activation by means of an infrared

sensor • The unit is switched off when the hands

are removed • Vandal resistant: Aluminium casing.

• Safety cut out device to avoid continued function

if exhaust is blocked.

White

SL-2500

Activated by means of Touch Control push

button. • Run-On-Timer of 50 seconds • Vandal

resistant casing: Aluminium casing • Two air

guide • Class I motor with self resetting thermal

protection.

SL-2002

Activated by means of a push button.

Run-On-Time of 45 seconds.

Polycarbonate casing.

Page 60: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

COMET 59

Commercial Hand & Hair Dryers

Class II, fitted with thermal protection andadjustable airflow. The unit turns on and offautomatically.

Allowing the user to set therequired airflow

Adjustable airflow

When the unit is lifted or replaced back into the cradle

Easy to install

Such as toilets. hotel bath-rooms, gymnasiums chang-ing rooms, washrooms, etc

Once installed, the unit cannot be removed without special tools avoiding stealing or inappropriate use

Automatic switch-off/power-off

Many applications in commercial instalations

118 4 100

228

Dimensions (mm)

SL-2002

Technical characteristics Model Max. power Voltage On Off Weight Colour

at free (V)

discharge (kg)

(W) 50 Hz

COMET 800 230 Automatic Automatic 1.25 White

when lifted when replaced

Page 61: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Commercial Air Curtains

60 COR-S Series

The air curtains of the S range are designed to be installed in reduced spaces to create a barrier between two different areas. Because of the volume/power ratio, they also fulfi ll a purpose as a space heater.

The range S is made up of two models of 4 and 6 kW respectively, both with two heating powers, two speeds and ambient thermostat. They can also work at two speeds without heating.They create an effective barrier up to a distance of 1.5 m.The installation of this type of air curtain is recommended in cases such as kiosk windows, service windows that must be opened to assist the public, windows which, due to differences in temperature, have a tendency to steam up and make exterior vision diffi cult. Model COR-6-900 S includes a remote control unit.

Technical characteristics Voltage Heat Motor Speeds Airfl ow Outlet Maximum �ΔT Absorbed Thermal Ambient/ Remote Weight Colour (50 Hz) power power (m3/h) speed (m/s) (°C) current fuse Hot control at 0,05 m air Speed Speed Max. Power Min. Power

Model (V) (kW) (W) high low high low High s. Low s. High s. Low s. (A) (kg)

COR-4-900 S 230 2 / 4 30,5 2 409 316 4,4 3,4 30 38 15 20 18 • A / H 7,15 White RAL 9003

400V + N

COR-6-900 S 230V 3 phase 3 / 6 30,5 2 409 316 4,4 3,4 40 55 20 28 26/15/8,6 • A / H • 7,5 White RAL 9003

230V 3 single ph

Dimensions (mm)

APPLICATIONS OF COR SERIES AIR CURTAINSWhenever there is a loss of warm or cold air due to the opening of doors or windows.To install an air curtain not only creates a barrier between two environments reducing the loss of warm or cool air, but it also prevents insects from entering a room, specially in food preparation areas. All air curtains are fi tted with a special device that activates them when the door is opened.Air curtains are very useful in:Commercial applications: bars, restaurants, cinemas, shops, supermarkets, hypermarkets, workshops, hairdresser’s, theatres, outpatient departments, hospitals, exhibition hall, schools,churches, banks, gyms, changing rooms, pools, sports centres.Industrial applications: entrance goods door in warehouses, halls, cold stores, drying installations, greenhouses.

Air distance / speed

Power heating selector andthermostat COR-4-900 S

Installation height

900 Series

Page 62: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Technical characteristics Voltage Heat Motor Speeds Airfl ow Air output Maximum �ΔT Sound Absorbed Thermal Ambient Ambient Weight Colour (50 Hz) power power (m3/h) speed* (m/s) (°C) pressure current fuse thermostat Hot at 0,05 m level** connection air Speed Speed

Model (V) (kW) (W) High Med Low High Med Low (db(A)) (A) (kg)

COR-F-1000 N 230 100 2 1420 1090 10,5 48 0,5 A 15,2 White RAL 9003

COR-F-1500 N 230 200 2 2675 2060 10,5 50 0,8 A 20 White RAL 9003

COR-3,5-1000 N 230 3,5 100 3 1384 1070 640 10 9 11 18 48 15,5 • • A / H 15,8 White RAL 9003

COR-6-1000 N 3N 400 3 / 6 100 3 1384 1070 750 10 14 18 26 48 8,6 • • A / H 15,8 White RAL 9003

COR-9-1500 N 3N 400 4,5/ 9 200 3 2545 1960 1180 10 13 15 25 50 13 • • A / H 20,8 White RAL 9003

*Maximum speed. ** Measured at 3 m distance, at free air.

COR-N Series 61

Commercial Air Curtains

Air distance / speed

Power selector CR-6/9 NRemote control unit fi tted with the fan to con-trol up to 5 units of the same model in series.The combinations of the following models can be controlled with a single remote control:COR F-1000 N with COR-F-1500 NCOR-6-1000 N with COR-9-15000 N

Designed for wall application in commercial or industrial environments.Characteristics:High performance tangential propeller/impeller giving a low sound level.Can be installed in series. Extra low speed in those fans that need a higher output air temperature (warm air versions)

Installation height

Dimensions (mm)

1000 Series 1500 Series

Page 63: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Commercial Air Curtains

62 COR Series

Designed for wall mounting in commercial and industrial environments.Characteristics:• High performance tangential propeller/impeller giving a low sound level.• Ambient air version: COR-2F• Ambient/Warm air versions: COR-10

Dimensions (mm)

L

208

184

Model L DimensionCOR-2F 2148COR-10 2148Air distance / speedInstallation height

Technical characteristics Voltage Heat Motor Speeds Airflow Output Maximum Sound Absorbed Ambient Manual Ambient / Weight Colour 50/60Hz power power speed* � ΔT pressure current thermostat reset Hot (m/s) level** connection thermal air Model (V) (kW) (W) (m3/h) at 0,05 m (°C) (dB(A)) (A) fuse (kg)

COR-2F 1~230 160 2 2220 8 47,5 1 • • A 25 Ivory RAL 9002

COR-10 3~400+N 5 / 10 160 1 2150 8 13,5 47,5 15 • • A / H 28 Ivory RAL 9002

* Maximum speed. ** Measured at 3 m distance, at free air.

Control unit COR-2F Control unit COR-10

Page 64: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

COR-IND M Series

63

Commercial Air Curtains

1390

405

315

Serie 1000

1970

405

315

Serie 1500

Dimensions (mm)

1390

405

315

Serie 1000

1970

405

315

Serie 1500

Designed for wall application in commercial or industrial environments.Characteristics:• High performance tangential impeller giving a low sound level.• Can be installed in series.• Available in ambient or ambient and hot air versions.• For installation at heights from 4 to 6 m.

Ease of installation Fitted with a hinged service cover to ease the wiring.

Technical characteristics

Installation heightAir distance / speed

Voltage Heat Motor Speeds Airflow Outlet Maximum �ΔT Sound Absorbed Thermal Ambient/ Weight Colour (50 Hz) power power (m3/h) speed* (m/s) (°C) pressure current fuse Hot at 0,05 m level** air Speed Max. Power Min. Power

Model (V) (kW) (W) high low High s. Low s. High s. Low s. (db(A)) (A) (kg)

COR-IND M 1000 F 230 267 2 3400 3037 12,84 55 1,2 • A 40 White RAL 9003

COR-IND M 1500 F 230 381 2 4849 4071 14,1 59 1,76 • A 50 White RAL 9003

COR-IND M 1000/18 3N 400 9 / 18 348 2 4955 4375 18.5 12,38 23,34 9,64 11,3 59 1,62 • A / H 45 White RAL 9003

*Maximum air speed **measured at 5m distance at free air

1000 Series

1500 Series

Accessories

CR-20 remote control unit

Remote control model Air curtain modelCR-20 COR-IND M 1000 F COR-IND M 1500 FCR-30 COR-IND M 1000/12 COR-IND M 1500/18Dimensions (mm) CR-20 / CR-30H 120 x W 80 x D 57 Each remote unit can control up to 5 units of the same model in series.The combinations of the following models can be controlled with a single remote control: COR-IND M-1000 F with COR-IND M-1500 F.

Page 65: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Accessories K SERIES

Accessories

64

PER-WBackdraft shutter

GRAAluminium guards

CXWorm drive clips

CM-130Backdraft shutter

CTCowel

GSAFlexiblealuminiumducting

PF-60Filter panel

CARBackdraft shutter

REBSingle phaseelectronic fan speed controlregulators

REGUL 2Two speedselectorswitch

CK-25 N CK-40 F CK-60 F

GSA-100 GSA-100 GSA-125

CX-80/125 CX-80/125 CX-125/215

PER-100 W PER-100 W PER-125 W

CAR-100 CAR-100 CAR-125

CM-130

CK-25 N CK-40 F CK-60 F

GRA-75 GRA-75 GRA-100

CT-125 CT-125 CT-125

PF-60 PF-60 PF-60

RWB-1N RWB-1N RWB-1N

RWB-1N E RWB-1N E RWB-1N E

REGUL-2

K Series

Are fitted with all the elements (extractor and accessories) needed to carry out a successful installation

CK kitchen Exhaust Fan Kits

Includes:1 CK-60 fan3m of GSA-100 flexible aluminium ducting2 Duct connectors CX-125/2151 Backdraft shutter CM-1301 two-speed switch REGUL-2

Includes:1 CK-40 fan3m of GSA-100 flexible aluminium ducting2 Duct connectors CX-80-1251 Backdraft shutter CM-130

Kit CK-40 F Kit CK-60 F

Page 66: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

GP GP “COQUE” Series

GRX Series

GP-ISO Series GPX Series

Flame retardant PVC: M1Bending radius: 0,6 x ØWorking temperature: from -18oC to 75oC

WORM DRIVE DUCT CLIPS (CX)

Dimensions Ø Equivalent Length

Model (mm) diameter (mm) (m)

GR 90 x 45 90 x 45 80 6

GR 135 x 70 135 x 70 125 6

GRX 90 x 45 90 x 4580 6

GRX 135 x 70 135 x 70 125 6

Flame retardant PVC: M1Bending radius: 0,6 x ØWorking temperature: from -18oC to 75oCGrey PVC rectangular flexible ducting supplied reinforced with polyester and supplied in 6 m compressed lengths for dwelling ventilation applications.

Dimensions Ø Equivalent Length

Model (mm) diameter (mm) (m)

GR 90 x 45 90 x 45 80 6

GR 135 x 70 135 x 70 125 6

GRX 90 x 45 90 x 4580 6

GRX 135 x 70 135 x 70 125 6

Worm drive flexible duct connection clips of various diameters. Suitable to fix flexible ducting to accessories.

Model Diameters (mm)

CX-80/125 From 80 to 125

CX-125/215 From 125 to 215

CX-250 250

CX-315 315

ALUMINIUM DUCT TAPE (BA-50)

Adhesive aluminium duct tape with 5 m lengths.

PLASTIC CIRCULAR BACK DRAFT SHUTTERS (CM-130)

Small diameter plastic back draft shutter to be installed within a circular duct to prevent back draft of air when the fans are switched off.

Model Diameters (mm)

CM-130 113/122 - 118/127

65

Accessories

Ø118Ø127

Ø122

Ø11

3

Ø133 136

Page 67: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

CIRCULAR INLET/OUTLET PROTECTION GUARDS (APC)

protection guards for direct connection to the inlet/outlet fan flange connector

Model ØA B

APC-125 125 232

APC-160 160 252

APC-200 200 275

APC-250 250 304

APC-315 315 342

APC-355 355 365

APC-400 400 391

APC-450 450 420

APC-500 500 449

APC-560 560 483

APC-630 630 524

APC-710 710 570

APC-800 800 622

60°

B

ØA

70 100

CIRCULAR BACK DRAFT SHUTTERS (CAR)

66

Back draft shutters to be installed within circular ducting to prevent back draft of air when the fans are switched off.

Model ØD L L1 L2

CAR-100 100 80 32

CAR-125 125 100 42

CAR-150 150 120 52

CAR-160 160 120 52

CAR-200 200 140 62

CAR-250 250 140 62

CAR-315 315 140 62 45

CAR-355 352 160 198

CAR-400 397 160 223

FLEXIBLE CONNECTOR (MSO)

Circular flexible connectors for fans designed for ventilation applications.

Model Ø(mm)

MSO 125 125

MSO 160 160

MSO 200 200

MSO 250 250

MSO 315 315

MSO 355 355

Model Ø(mm)

MSO 400 400

MSO 450 450

MSO 500 500

MSO 560 560

MSO 630 630

MSO 710 710

CIRCULAR FLEXIBLE CONNECTOR (KAA)

Circular flexible connectors designed for smoke extract fans in fire conditions and certified F400 120.

Model Ø(mm)

KAA-120 112

KAA-140 125

KAA-160 160

KAA-180 180

KAA-200 200

KAA-225 225

KAA-250 250

KAA-280 280

Model Ø(mm)

KAA-315 315

KAA-355 355

KAA-400 400

KAA-450 450

KAA-500 500

KAA-560 560

KAA-630 630

KAA-710 710

METALLIC ROOF TERMINAL COWL (CT)

Designed for circular duct connection, the CT roof terminal kit enable air discharge or supply through a flat or pitched roof.

Model A B C Ø D E F G H I J Weight

(kg)

CT-125 54 200 250 125 70 500 400 –

CT-150 65 248 300 150 70 500 400 – –

CT-200 100 333 400 200 85 600 600 160 500 500 8

CT-250 100 333 400 250 85 600 600 160 500 500 8

CT-315 112 420 500 315 85 600 600 140 500 750 9

CT-355 200 550 660 355 150 900 750 225 600 750 17

CT-400 200 550 660 400 150 900 750 225 600 750 17

CT-450 200 550 660 450 150 900 750 225 600 750 17

CT-500 245 650 850 500 160 1200 1000 215 780 997 34

CT-630 320 780 1000 630 160 1200 1000 215 780 997 36 Model Discharge Supply

CTM 125 350 165

CTM 150 425 245

CTM 200 900 600

CTM 250 1050 850

CTM 315 1800 1100

CTM 355 2600 1700

CTM 400 3000 2100

CTM 450 3600 2600

CTM 500 4700 3500

CTM 630 8000 4500

USE: Recommended air volumes

(Pressure drop 20 Pa)

Accessories

Page 68: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

67

PLASTIC ROOF TERMINAL COWL (CTP)

Designed for circular duct connection, the CTP roof terminal kit enable air discharge or supply through a flat or pitched roof.

Model A B C Ø D E F G H Weight

(kg)

CTP 125 72 203 280 125 80 500 400 140 3,5

CTP 150 72 203 280 150 80 500 400 140 3,5

CTP 160 72 203 280 160 80 500 400 140 3,5

Model Discharge Supply

CTP 125 320 170

CTP 150 320 210

CTP 160 320 210

DUCT CONNECTOR FOR ROOF TERMINAL COWL (BROCHAL)

Duct connector enabling to fit the flexible duct just before the roof terminal cowl.

Models:Brochal 125Brochal 150

ROOF EXTERNAL FRESH AIR GRILLE

External fresh air grille for dwelling ventilation application with heat recovery system.

WALL EXTERNAL FRESH AIR GRILLE

External fresh air grille for dwelling ventilation application with heat recovery system.

150 mm

150 mm

ALUMINIUM GRILLE (GRA)

Aluminium externally / internally mounted discharge / supply air grilles.

Model External Grille dimensions area A B

GRA-70 130 x 130 100 x 100

GRA-100 165 x 165 125 x 125

GRA-150 190 x 190 150 x 150

GRA-200 210 x 210 165 x 165

GRA-300 240 x 240 200 x 200

ALUMINIUM INTERNAL GRILLE (GRI)

Extract louvre grilles manufactured from aluminium and finished with an epoxy polyester paint coating.

Model Available nominal dimensions

GRI-125 125 x 125

GRI-200 200 x 200

GRI-250 250 x 250

GRI-300 300 x 300

GRI-450 450 x 450

TERMINAL CONNECTOR (RP) FOR GRI INTERNAL GRILLE

The RP plenums are manufactured from galvanised sheet steel. Six diameters are available for corresponding GRI grilles.

Model Available nominal dimensions

GRI-125 125 x 125

GRI-200 200 x 200

GRI-250 250 x 250

GRI-300 300 x 300

GRI-450 450 x 450

200

250

125

450

0.180.15

0.125

0.100.080.070.060.05

0.0450.04

0.030.025

0.015

0.02

0.0050.006

0.01

0.035

0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 9 10

Q(m3/h)

4000

3000

2000

1500

1000900800700

Air volume and air speed comparison (m/s)

Open surface (m2)

speed (m/s)

Accessories

Page 69: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Accessories

68

ØA

ØB

L1

ØC

Ø

E

L

GCI – CIRCULAR SUPPLY/EXHAUST GRILLES

Air diffuser extract/supply grilles manufactured from aluminium and finished with epoxy-polyester paint coating.

Model A B C Net free area Min. air Max. air

(m2) volume volume

GCI-160 140 250 200 0,0086 70 275

GCI-200 190 300 250 0,0200 120 500

GCI-250 240 350 300 0,0326 200 800

GCI-315 290 400 350 0,0460 275 1100

GCI-350 340 450 400 0,0550 350 1200

GCI-400 390 500 450 0,0702 400 1500

VR mounting accessory for GCI circular grilles

Mounting support to facilitate the installation of the GCI circular grilles and connection to ducting.

Flexible

ducting

INTERIOR AIR EXHAUST VALVE (BOC)

Metallic air exhaust valves for dwelling and commercial applications. All models offer an adjustable central valve to regulate the airflow. They can be used in heating, air conditioning and ventilation system.

Model Ø A Ø B Ø C Ø D Ø E L

BOC-100 100 125 74 75 137 47

BOC-125 125 150 98 100 161 49

BOC-160 160 185 128 149 218 60

BOC-200 200 225 157 157 248 75

INTERIOR AIR EXHAUST VALVE (BOR)

White polystyrene air exhaust valves for dwelling and commercial applications. All models offer an adjustable central valve to regulate the airflow. They can be used in heating, air conditioning and ventilation system.

Duct diameter Duct Plasterboard Paving slab and thick

Ø (mm) mounting valve mounting valve wall mounting valve

Model Model Model

80 BOR 80 BOR 80 P BOR 80 D

100 BOR 100 BOR 100 P BOR 100 D

125 BOR 125 BOR 125 P BOR 125 D

150 BOR 150 BOR 150 P BOR 150 D

160 BOR 160 BOR 160 P BOR 160 D

200 BOR 200 BOR 200 P BOR 200 D

Connector dimensions (mm)

Model Air flow Ø A Ø A1 Ø B Ø B1 C H

BOR 80 from 10 to 100 m3/h 78 77 99 110 100 275

BOR 100 from 15 to 160 m3/h 89 98 130 129 100 250

BOR 125 from 25 to 200 m3/h 122 120 155 155 130 275

BOR 150 from 30 to 250 m3/h 148 145 195 195 100 250

BOR 160 from 30 to 250 m3/h 158 155 195 195 100 250

BOR 200 from 55 to 330 m3/h 198 195 235 235 100 250

Characteristics and dimensions (mm)

3-claw mounting connector

Ø A

C

Ø B

Duct mounting connector with rubber seal

Ø A1 Ø B1

Paving slab and thick wall mounting connector

Ø A

Ø B

HH

Page 70: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

69

Accessories

BOAP 80

BOAE 80 BOAC 80

BOAP 125 BOAE 125 BOAC 125

BOAP 80 60

���60

A

A

A

A

60

���120

PLASTIC REDUCER (RED)

Model Diameters (mm)

RED-100/80 100-80

RED-125/100 125-100

RED-150/125 150-125

RED 160/125 P 160-125

RED 200/160 P 200-160

RED-250/200 250-200

Plastic sections for the connection of two ducts of different diameters.

PLASTIC DERIVATION (DERIV)

Model

DERIV 80/80 P

DERIV 125-60-60-125 P

DERIV 125-60-60-60 P

DERIV 150-125-125 P

DERIV 150-60-60-125 P

Plastic sections for the connection/adaptation of different duct diameters.

PLASTIC GRILLE (GR-100)

Plastic interior or exterior mounting air discharge grilles. Designed for direct connection to 100 mm diameter ducting.

WALL KIT

Wall kit with fixed grille for use with EDM-80N, EDM-100, DÉCOR-100 and SILENT-100.The kit includes a plastic external grille and a telescopic duct wall liner. The kit allows the fan to be installed in walls of 20-42 mm thickness.

PLASTIC CIRCULAR DUCT JOINING PIECE (MRT)

Plastic pieces allowing the connection of two ducts of the same diameter.

PLASTIC EXHAUST VALVES (BOC)

Plastic exhaust valves manufactured from injection

moulded white polypropylene plastic.

• BOCP are supplied with 3-claw mounting connector

suitable for plasterboard and ceiling tiles installation.

• BOAE are supplied with a large mounting connector

suitable for paving slabs and thick walls

Model Ø Connector type

(mm)

BOCP 80 80 Ht 100 - 3-claw mounting connector

BOCP 125 125 Ht 100 -3-claw mounting connector

BOC 80 80 Ht 275 - Thick wall mounting connector

BOC 125 125 Ht 275 -Thick wall mounting connector

BOC 80 80 Ht 300 - Bent mounting connector

BOC 125 125 Ht 440 - Bent mounting connector

Dimensions (mm)

A 80 129mm125 172mm

Page 71: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Wiring DiagramsGENERAL WIRING DIAGRAMS: Domestic Fans

70MODELS: DV; VM; H CONTROLLED BY INTEGRAL PULLCORD OR SENSOR

230V~50Hz

EXCLUDES SELV 12V FANS AND SYSTEM PRODUCTS

MODELS: T; R; CR; CT; HM; HT CONTROLLED BY REMOTE SWITCHED LIVE

230V~50Hz

CONTROLLED BY REMOTE SWITCHMODELS: EC: C

230V~50Hz

eg. SILENT-100 12V DECOR-100 12V EDM-100 12V

* Also available: CT/1214 R to give adjustable run-on time

SELV TRANSFORMER

230V~50Hz

*

SELV (Safety Extra Low Voltage)

Page 72: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

71

Wiring DiagramsHV-STYLVENT options

Fig 1

Fig 3

Fig 2

Fig 1: STYLVENT 150 and STYLVENT 230 & 300 (Pullcord models)Fig 2: STYLVENT 230 and 300 extract/intakeFig 3: STYLVENT 230 and 300 extract or intake only

HV STYLVENT HV-150 M; HV-230 M; HV-300

HV STYLVENT HV-150 M; HV-230 RC; HV-300 RC

1. Fan Stopped; Shutter open

2. Fan Stopped; Shutter closed

3. Fan on High Speed; Shutter open

4. Fan in Reverse (High Speed); Shutter open

5. Fan on Low Speed; Shutter open

6. Fan in Reverse (Low Speed); Shutter open

6

Live

HV STYLVENT; HV-150 A; HV-230 A; HV-300 A

Fig 1

Fig 3

Fig 2

1. Extraction only

2. Intake only

3. Extraction and intake (reversible) with the CRS-150

Page 73: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and

Wiring DiagramsTD ECOWATT options

72

Fig 1a

TD-ECOWATT 160/100

Fig 1a TD ECOWATT Connection directly to a 230V supplyFig 1b TD ECOWATT Connection to available speed controllerFig 2a TD ECOWATT Connection to a 230V supplyFig 2b TD ECOWATT Variable speed controllerFig 3a TD ECOWATT Connection to other external sensorsFig 3b TD ECOWATT Connection to other external sensorsFig 3c TD ECOWATT Connection to other external sensorsFig 4 TD ECOWATT Directly to a 230V supplyFig 5 TD ECOWATT Variable speed controller

Fig 1b

Fig 2a Fig 2b

TD-ECOWATT 160/100

TD-ECOWATT 250/100; 350/125

Fig 4

TD-ECOWATT 160/100

Fig 3a Fig 3b

Fig 3b

TD-ECOWATT 500/150; 800/200

Fig 5

Page 74: lay v5 master - Find The Needlepdfs.findtheneedle.co.uk/79570-2003.pdf · check online at For current Building Regulations in Northern Ireland ... to 33 for Soler & Palau fans and