+ All Categories
Home > Documents > LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides...

LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides...

Date post: 07-Jun-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
10
LC6B Benchtop Conveyor Parts Listing Document No. 588661 Revision K, dated May 2016
Transcript
Page 1: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B Benchtop Conveyor

Parts Listing

Document No. 588661 Revision K, dated May 2016

Page 2: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

© Copyright 2011-2016 Heraeus Noblelight America LLCAll Rights Reserved.

Heraeus Noblelight America LLC910 Clopper RoadGaithersburg, MD 20878-1357 USA301-527-2660 • FAX 301-527-2661

Heraeus Noblelight America LLC reserves the right to make changes without prior announcement.

2 LC6B 588661 Rev. K ©Heraeus

Page 3: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B PARTS LISTING

LC6B PARTS LISTING

Contained within this document are the part numbers for your genuine Heraeus UV parts. Heraeus Noblelight America LLC (formerly Fusion UV Systems) received full ISO certification in 1993 and we maintain that certification today to the ISO 9001:2008 standard, which underscores our commitment to providing the highest quality components, systems, support, training, process development, and after sales service.

For the most current Replacement Parts Listing for the LC6B Benchtop Conveyor, please visit:

http://www.heraeus-noblelight.com/spareparts

On-Line StoreCustomers can now place parts orders online*. Our Web Store provides a new level of efficiency and convenience and features:

• 24/7 access

• fully secure website

• pictorial catalog of parts

• ability to review open or closed parts orders, invoices, and returns

• ability to track your parts shipments

• A discount is given for ALL parts ordered online

If you are not yet registered for the Web Store but would like to do so, please contact Sales Support on 1-301-990-8600 or [email protected].

* Only customers who place orders directly with Heraeus Noblelight America LLC may register for the online store. If you currently order parts through a local Heraeus Noblelight distributor, please contact them directly for all parts orders.

This document replaces any parts listings that may be contained within the LC6B Installation, Operation, and Maintenance Manual.

©Heraeus LC6B 588661 Rev. K 3

Page 4: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B PARTS LISTING

Customer SupportThe following groups within Heraeus Noblelight America LLC are available to provide customer support.

Sales SupportThe Sales Support group is responsible for the processing of domestic and international quotation requests as well as the purchase orders of spare parts, systems, and online orders.

Contact Sales Support at [email protected].

Technical ServiceThe Technical Service group is responsible for worldwide after sales support including repair services whether returned to a Heraeus Noblelight Service Center or at the customer site. This group also provides new equipment commissioning, maintenance and operator training, telephone/email/fax support, maintenance programs such as multi-level service contracts, and certified rebuilt equipment. Our service staff averages nearly 16 years of hands-on experience with Fusion UV equipment!

Contact Technical Services at [email protected].

Applications EngineeringThe Applications Engineering group concentrates on the optimization of a customer’s UV process or proposed process and in assisting customers with troubleshooting of their UV curing process. Their expertise includes system selection and configuration; determination of system size, lamp type, and optics; machine design concepts, integration; and air handling systems and measurement (radiometry and thermometry).

This group oversees and operates the Applications Lab in which processes can be developed, demonstrated, or refined using any of a wide range of UV exposure equipment available, including all lamp and bulb types.

Contact Applications Engineering at [email protected].

4 LC6B 588661 Rev. K ©Heraeus

Page 5: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B PARTS LISTING

LC6B Replacement Parts

LC6/LC6B Replacement Parts

Item # Description Reference Designator

LC6 Model w/ LCD (black

numbers)*

LC6B Model w/ LED (red numbers)

1 Connector, power inlet with SPST line switch, 250V, 10 A, IEC

-- 253713

2 not shown

RF detector bracket -- 75321

3 Belt, KEVLAR®, conductive (standard) -- 27765

4 PWB assembly Kit, interface (contains fuses) -- 328781 600181

5Cable assembly, encoder, for belt travel Left to Right, LC6B -- 514872

Cable assembly, encoder, for belt travel Right to Left, LC6B -- 514871

6 Display, speed -- 511701 514161

7 Knob, speed control -- 30443

8 Switch, rocker, DPDT -- 242002 529571

9 Motor controller kit, 120/240V, variable speed (contains controller, fuses, and resistors)

-- 574841

10 Terminal block assembly (installed in units built after June 2013)NOTE: Units manufactured prior to July 2013 had a different crossflow blower unit and included a capacitor in this location. The earlier crossflow blower and associated capacitor are no longer available.

-- 599041

©Heraeus LC6B 588661 Rev. K 5

Page 6: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B PARTS LISTING

not shown Bearing/carrier (without roller) -- 275361

not shown Bearing/carrier/encoder mounting, LC6B -- 528601

not shown Drive pulleys and belt kit, 2-250 fpm -- 323681

not shown Encoder, shaft mount, 512 pulse/revolution -- 292972 514701

not shown Fuse, 3AG, fast acting, 1 Amp, 250V (on LC6 interface bd) F1, F2 295331

not shown Fuse, 3AG, fast acting, 0.5 Amp, 250V (on LC6 interface bd) F3 295332

not shown Fuse, 3AG, fast acting, 8.0 Amp, 250V (on LC6 interface bd) F4 23496

not shown Fuse, 2.0 Amp, 250V dual, (motor controller) F1 23481

not shown Fuse, 3AG, fast acting, 1 Amp, 250V, (motor controller) F2 295331

not shown Fuse, 5x20mm, time delay, 6.3 Amp, 250V (on LC6B interface bd)

F1 296399

not shown Fuse, 5x20mm, time delay, 1 Amp, 250V (on LC6B interface bd) NOTE: Units manufactured prior to July 2013 had a different type of crossflow blower unit with different amperage requirements. For units with a capacitor instead of terminal block, use a 1A fuse for replacement.

F2, F3 302611

not shown Fuse, 5x20mm, time delay, 2 Amp, 250V (on LC6B interface bd)NOTE: Units manufactured after June 2013 have a different type of crossflow blower unit with different amperage requirements. For units with a terminal block instead of capacitor, use a 2A fuse for replacement.

F2, F3 302614

not shown Motor Kit, PMDC, 93 rpm, 1/30 HP, 90 Vdc (high speed Model)

-- 583201

not shown Motor Kit, PMDC, 11 rpm, 1/30 HP, 90 Vdc (low speed Model)

-- 583202

not shown Pin, belt interlace, Teflon® coated -- 589871

not shown Power cord, IEC320/US 120V, 10A -- 261623

not shown Power cord, IEC320/Bare, 250V, 10A -- 261622

not shown Resistor, motor control, 0.25 Ohm R21 302633

not shown RF detector assembly kit (contains RF detector and bracket) -- 79961UV

not shown Roller assembly (includes roller and bearings) -- 513551

not shown Screw, roller bearing alignment, M4 -- 109265

* The principle difference between models LC6 and LC6B is in the type of display used. The LC6, manufactured before March 1999, has an LCD readout with black numbers displayed and the LC6B has an LED readout with red numbers displayed.

NOTE: The replacement of the crossflow blower is a significant activity. Please consult with Heraeus Noblelight Technical Services.

LC6/LC6B Replacement Parts (continued)

Item # Description Reference Designator

LC6 Model w/ LCD (black

numbers)*

LC6B Model w/ LED (red numbers)

6 LC6B 588661 Rev. K ©Heraeus

Page 7: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

LC6B PARTS LISTING

LC6B Optional Items/Accessories

LC6B Cables

Description HeraeusPart Number

Air deflection kit, high-grade quartz (for 1 lamp) 326602

Belt, KEVLAR®, conductive, with center strip (optional) 27766

Belt, PTFE/Glass, close weave (optional) 590941

Belt, stainless steel, retrofit kit (optional) 299111

Blanking plate, LC6B 585021

Exhaust blower, 3 phase, 200/230/400/460 VAC, 50/60 Hz (649 cfm, 18.4 m3/min) for use with 2 I6B lamps

80126420

Exhaust blower, 3 phase, 190/230/380/460 VAC, 50/60 Hz (460 cfm, 13.0 m3/min) for use with 2 I300MB lamps

80126421

Exhaust duct plenum, 200 mm, UP or DOWN 275371

Exhaust transition duct/reducer, 8” to 6” (for use with external exhaust blower 80126420)

80126449

Exhaust transition duct/reducer, 8” to 7” (for use with external exhaust blower 80126421)

80126450

External end reflector, each (2 recommended) 43271

Feed chute, infeed or outfeed 326591

Knife, outfeed 383321

Kit, Quartz tray assembly (for use with 2-lamp boot)NOTE: Kit is for one lamp slot only. If quartz tray is needed for both lamp slots, order two kits.

585061

Sight shield, snap-in, “box-end” style 275452

Sight shield, snap-in, “tunnel” style 275451

Variable cooling (VFD) controller, LH6, 200-240V, pre-programmed

590071

Variable cooling (VFD) controller, LH6, 380-480V, pre-programmed

590072

Variable cooling (VFD) controller/blower kit, LH6, 380-480V, European (contains pre-programmed VFD controller, blower, cable, and line filter)

590073

Reference Designator Description Use Heraeus

Part Number

P105B to P106 Adapter cable, harness LC6B to LH6PS 529862

-- Adapter cable LC6B to LH6PS and VFD 570981

J106 Adapter cable, pigtail LC6B to VPS I/O module 529861

P106 Control cable, remote LC6B to P300Mx 529701

©Heraeus LC6B 588661 Rev. K 7

Page 8: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

Numerical Listing of Replacement Parts

Numerical Listing of Replacement Parts

Numerical Listing of LC6B Parts

Description HeraeusPart Number

Fuse (LC6/LC6B motor controller), 2.0 Amp, 250V dual, F1 23481

Fuse, 3AG, fast acting, 8.0 Amp, 250V (on LC6 interface bd), F4 23496

Belt, KEVLAR®, conductive (standard) 27765

Knob, speed control 30443

RF detector bracket 75321

RF detector assembly kit 79961UV

Screw, roller bearing alignment 109265

Switch, rocker, DPDT, LC6 242002

Connector, power inlet with SPST line switch, 250V, 10 A, IEC 253713

Power cord, IEC320/Bare, 250V, 10A 261622

Power cord, IEC320/US 120V, 10A 261623

Bearing/carrier (without roller) 275361

Encoder, shaft mount, 512 pulse/revolution, LC6 292972

Fuse, 3AG, fast acting, 1 Amp, 250V (on LC6 interface bd), F1/F2Fuse, 3AG, fast acting, 1 Amp, 250V, (on LC6/LC6B motor controller), F2

295331

Fuse, 3AG, fast acting, 0.5 Amp, 250V (on LC6 interface bd), F3 295332

Fuse, 5x20mm, time delay, 6.3 Amp, 250V (on LC6B interface bd), F1 296399

Fuse, 5x20mm, time delay, 1 Amp, 250V (only on LC6B interface board in units with capacitor), F2/F3

302611

Fuse, 5x20mm, time delay, 2 Amp, 250V (only on LC6B interface board in units with terminal block), F2/F3

302614

Resistor, motor control, 0.25 Ohm, R21 302633

Drive pulleys and belt kit, 2-250 fpm 323681

PWB assembly, interface, LC6 328781

PWB assembly, interface, LC6B 509461

Display, speed, LC6 511701

Roller assembly (includes roller and bearings) 513551

Display, speed, LC6B 514161

Encoder, shaft mount, 512 pulse/revolution, LC6B 514701

Cable assembly, encoder, for belt travel Right to Left, LC6B 514871

Cable assembly, encoder, for belt travel Left to Right, LC6B 514872

Bearing/carrier/encoder mounting, LC6B 528601

Switch, rocker, DPDT, LC6B 529571

8 LC6B 588661 Rev. K ©Heraeus

Page 9: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

Numerical Listing of Replacement Parts

Motor controller kit, 120/240V, variable speed (contains controller, fuses, and resistors)

574841

Motor Kit, PMDC, 93 rpm, 1/30 HP, 90 Vdc (high speed Model) 583201

Motor Kit, PMDC, 11rpm, 1/30 HP, 90 Vdc (low speed Model) 583202

Pin, belt interlace, Teflon® coated 589871

Numerical Listing of LC6B Parts (continued)

Description HeraeusPart Number

©Heraeus LC6B 588661 Rev. K 9

Page 10: LC6B Parts 588661K - Heraeus › media › media › hng › doc_hng › products_… · provides new equipment commissioning, maintenance and operator training, telephone/email/fax

Heraeus Noblelight America LLC

Heraeus Noblelight GmbH

Heraeus K.K.

Heraeus Noblelight (Shenyang) Ltd.

910 Clopper Road Phone: +1 301-527-2660Gaithersburg, MD 20878-1357 USA Fax: (Technical Service) +1 301-527-2663www.heraeus-noblelight.com/fusionuv Fax: (Sales) +1 301-527-2661

email: [email protected]

Heraeusstraße 12-14 Phone: +49 6181 35 496663450 Hanau, Germany Fax: +49 6181 35 9926

email: [email protected]

Noblelight DivisionSumitomo Fudosan Otowa Phone: +81 3 6902 6602Bldg. 1F, 2F, 5F Fax: +81 3 6902 66132-9-3 Otsuka, Bunkyo-ku, email: [email protected], Tokyo Japan

Shanghai Branch2F, Building 5, No. 406 Guilin Road Phone: +86 (21) 3357 5555Xuhui District Fax: +86 (21) 3357 5333Shanghai 200233, P.R. China email: [email protected]


Recommended