For pathways, courtyards and entrances. Era ® Lantern Bollard LOW LEVEL LE1/2/3
Transcript

For pathways, courtyards and entrances.

Era® Lantern Bollard

LOW LEVEL

LE1/2/3

MAILING ADDRESSP.O. BOX 60080CITY OF INDUSTRY, CA91716-0080

BUSINESS ADDRESS16555 EAST GALE AVENUECITY OF INDUSTRY, CA 91745PHONE: 626.968.5666FAX: 626.369.2695

ENTIRE CONTENTS© COPYRIGHT 2009 KIM LIGHTING INC.ALL RIGHTS RESERVEDREPRODUCTION IN WHOLE OR IN PARTWITHOUT PERMISSION IS STRICTLY PROHIBITED.PATENTS PENDING

www.kimlighting.com

Printed in U.S.A.93019717Version 1.1 (11/09)

Era® Lantern Bollard

Era® Lantern Bollard Series

Proportion Guide

Specifications

Ordering Information

Photometrics

Lamp and Electrical Guide

1

2

3

4

5

TABLE OF CONTENTS

This proportion diagram is intended to help visualize and select the best Era® Lantern system to satisfy aestheticrequirements.

LE1TraditionalBollard

LE2TraditionalBollard

LE3TraditionalBollard

Timeless, high performance historical lighting integration throughout thesite is now possible with Kim Lighting’s Era Lantern luminaire collection,which now includes an authentically detailed replica bollard series tocomplete the class.

Traditionally,“form before function” was the conventional approach to historic luminaire design, however Era Lantern Bollard optics areunmatched by any other period pathway luminaire. Era Lantern Bollardsfeature high 95% reflectivity, precise light distributions,advanced Pulse Start Metal Halide, HPS, CFL and LEDoptions, and battery back-up modules for emergency illumination. Era Lantern Bollards also meet strict IES and IDA full cutoff dark sky standards, and are constructed with Kim Lighting’s legendary reputation for quality and durability to last a lifetime.

KimLighting.com offers lighting professionals unlimited access to the entire Era Lantern series, including specifications,photometry data, and design tools. Contact your Kim Lighting representative for additional assistance.

Era Lantern Bollard. This is outdoor lighting perfection. This is Kim Lighting.

Era® Lantern Bollard

KIM LIGHTING 1

LE1 LE3LE2

LEB26SC/HA32LWWall Mount

LET19DC/HA12SWWall Mount

LET19SC/HA12S16' Stepped Smooth Pole

LET19SS/HA02S12' Stepped Fluted Pole

LEB19DC/HA13S16' Stepped Fluted Pole

LET26SS/HA14L20' Straight Smooth Pole

LET26DC/HA37L30' Stepped Fluted Pole

LEB26SC/HA32L25' Stepped Fluted Pole

5" DIA.

3.4" DIA.

5" DIA.

3.4" DIA.

5" DIA.

6" DIA.

4" DIA.

6" DIA.

4" DIA.

6" DIA.

4" DIA.

Choose one of three shaft styles.

Era® Lantern Bollard

Luminaire Specifications

2 KIM LIGHTING

5" BOLT CIRCLE DIA.

2G" x 3O"CONDUIT OPENING8N" DIA.

(217.5 mm)

5" BOLT CIRCLE DIA.

3L" x 1L" CONDUIT OPENING 10B" DIA.

(257.2 mm)

Era® Lantern Bollard 70 to 100 watt PMH

70 to 100 watt HPS 42 watt CFL30, 45 or 60 watt LED

Dimension s

28"(711.2 mm)

28" (711.2 mm)

28" (711.2 mm)

11K" DIA.(292.1 mm)

4N"(115.8 mm)

9D"(244.5 mm)

5B" DIA.(130.2 mm)

9C" DIA.(238.1 mm)

5" DIA. (127.0 mm)

9C" DIA. (238.1 mm)

10L" DIA. (273.1 mm)

5" DIA. (127.0 mm)

5" DIA. (127.0 mm)

Smoooth - LE1 Fluted - LE2 Traditional - LE3

LE 1/2/3

SPECIFICATIONS

Kim Lighting reserves the right to change specifications without notice.

HOOD AND LENS FRAME: Die-cast, low copper aluminum alloy(<0.6% Cu) with stainless steel hinge. Hood is opened by loosening onestainless steel captive button-head socket cap screws.The B" thick clearflat tempered glass lens seals against the lens frame by a one-pieceextruded and vulcanized silicone gasket.The lens frame seals against the hood by a one-piece extruded and vulcanized silicone gasket.

ARM: Double curved die-cast, low copper aluminum alloy with internal wiring chamber supports the hood and lens frame.

HUB: Die-cast, low copper aluminum alloy with a die cast accesscover. The hub is designed to support the arms.

REFLECTOR MODULE: Specular Alzak® optical segments are rigidly mounted within an aluminum frame and fastened securely to the hood. A porcelain medium base socket rated 4KV is provided forHID and a GX24q-4 universal socket is provided for fluorescent.No reflector provided for LED.

ANCHOR BASE PLATE: A heavy cast aluminum anchor base plateis provided for mounting to the four C" x 10" + 2" zinc plated J-bolts,each with two nuts and washers.A rigid pressed board template is provided to secure the anchor bolts during concrete pour. 5" B.C.D.rods sandwich shaft between base and head.

ELECTRICAL MODULE: Factory mounted to a rigid assemblyattached to the anchor base. HID: High Power Factor with startingtemperatures of -20°F for PMH and -40°F for HPS lamp modes.Fluorescent: High Power Factor with starting temperature of 0°F.LED: A total of 9 LED emitters configured in a rectangular array comprised together as a module. Two (2) modules for 30 watt version;three (3) modules for 45 watt version; and four (4) modules for 60 watt version. Available in “Halogen White” (approx. 3500K).Emitters are directly attached to the electronic driver.

LED DRIVER: Constant current electronic driver. Rated for 30 watt, 45 watt or 60 watt. Available in 120 volt or 277 volt input.0ºF. starting temperature. All drivers are Underwriters Laboratoriesrecognized. 120V versions are dimmable.

RISER: Smooth – The Riser assembly is a one-piece smooth aluminum extrusion (.188" minimum wall thickness) and a heavy castaluminum base cover. Two internal C" mounting rods sandwich riserbetween base and hub. Fluted – The riser assembly is a one-piecefluted aluminum extrusion (.188" minimum wall thickness) and a heavycast aluminum base cover. Two internal C" mounting rods sandwichriser between base and hub. Traditional – The riser is a heavy cast aluminum base cover. Two internal 3/8” mounting rods sandwich riser between base and hub.

FINISH/COLOR: Super TGIC thermoset polyester powder coatpaint, 2.5 mil nominal thickness, applied over a titanated zirconium conversion coating; 2500 hour salt spray test endurance rating.Standard colors are Black, Dark Bronze, Light Gray, Stealth Gray™,Platinum Silver, or White. Custom colors are available.

CAUTION: Fixtures must be grounded in accordance with national,state and/or local electrical codes. Failure to do so may result in seriouspersonal injury.

Listings and RatingsUL cUL 15981 CE IP46 25C Ambient

1Suitable for wet locations.

Era® Lantern Bollard

KIM LIGHTING 3

3 Luminaire Finish:Super TGIC powder coat paint over titanated zirconiumconversion coating.

Color: Black Dark Bronze Light Gray Stealth Gray™ Platinum Silver White Custom Colors

Cat. No.: BL DB LG SG PS WH CC

Consult your KimLighting representativefor custom colors.

Line Volts: 120V 208V 240V 277V 347VCat. No.: SF DF DF SF SF

Cat. No.: LS Lexan molded high transmission luminous white enclosure replaces standard glass lens

Cat. No.: A Acrylic molded high transmission luminous white acrylic enclosure replaces standard glass lens

6 Lantern Enclosures Optional lanternenclosure

Cat. No.: HS Optional shield made of stamped louvered aluminum allowsstreetside light to pass while blocking houseside light. Blackenedreflector panels within the reflector also reduces the housesidereflection..

4 Optional HousesideShield:

5 Optional Fusing:

7 Optional EmergencyBattery Back-up:For Compact Fluorescent only.

HousesideShield

Ordering Information

PMH = Pulse StartMetal Halide

HPS = High Pressure Sodium

PL = Compact Fluorescent

LED = Light Emitting Diode

See lamp and electrical data onpage 5 for ballast types and characteristics.

Lamp Lamp LineWatts Type Volts

70 PMH 120

42PL1201

42PL2081

42PL2401

42PL2771

30LED12030LED27745LED12045LED27760LED12060LED277

70PMH12070PMH20870PMH24070PMH27770PMH347

100PMH120100PMH208100PMH240100PMH277100PMH347

Pulse Start Metal Halide70HPS12070HPS20870HPS24070HPS27770HPS347

100HPS120100HPS208100HPS240100HPS277100HPS347

2 Electrical Module:

Ordering Example: LuminaireFixture Electrical Module Finish Options

LE1 / 70PMH120 / BL / HS1 2 3 4-7

1 Fixture:Cat. No. designates LE fixture

Cat. No.: LE1 LE2 LE3

High Pressure SodiumCompact Fluorescent

142PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz).

NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative.

LED

Cat. No.: EM Internal battery pack provides 90 minutes of supplemental light at 23% of initial lamp lumens for 26, 32 or 42 watt compact fluorescent lamps.

} IESType1

} IESType3

} IESType 5

8 Optional Cold-PackEmergency Battery Pack:

Cat. No.: EM-CP The EM-CP option is a temperature controlled ballast designed tomaintain operation without interruption within a range of hi/lowambient temperatures, -20°C to +55°C.

Internal Cold-Pack emergency battery pack provides up to 90minutes of supplemental light. See table at right for max. lumensoutput by lamps.

Lamp (4-Pin) 1 lamp lumens42W 75032W 57526W 450

Era® Lantern Bollard

Photometrics

4 KIM LIGHTING

LE1/2/3 Luminaire with Houseside Shield

60° 60°

9601280

320640

60°

120° 120°

90° 90°

30° 30°

150° 150°

0'33''66'' 3'6'9'12'15'18'21'

33''

66''

12'

15'

18'

21'

33''

66''

00''

99''

99''

3'

6'

3'

6'

0'

9'

9'

12'

15'

18'

21'

600800

200400

30° 30°

60° 60°

90° 90°

120° 120°150° 150°

0'3'6'9'12'15'18'21'

0'

33''3'

6'

9'

12'

15'

18'

21'

3'

6'

9'

12'

15'

18'

21'

House Side

Path Side

PATH SIDE HOUSE SIDE0°0°0°

600600600800800800

200200200400400400

30°30° 30°30°

60°60° 60°60°

90°90° 90°90°

120°120° 120°120°150°150° 150°150°

30° 30°

60° 60°

90° 90°

120° 120°150° 150°

3'

A 70W PMH, ED-17 Med. Base, Coated, 5300 initial lumensB 100W PMH, ED-17 Med. Base, Coated, 8500 initial lumensC 70W HPS, ED-17 Med. Base, Coated, 5860 initial lumensD 100W HPS, ED-17 Med. Base, Coated, 8800 initial lumensE 42W PL-T, GX24q-4 Base, 3200 initial lumens

Typical HalfInitial Horizontal Footcandles for 42K" Bollard (39F" Light Center)

Typical Half

Initial HorizontalFootcandles for42K" Bollard (39F" Light Center)

A B C D E17.1 27.4 18.9 28.4 8.14

3.45 5.53 3.81 5.73 2.920.62 0.99 0.68 1.02 0.68

0.13 0.21 0.15 0.22 0.17

0.04 0.06 0.05 0.07 0.050.02 0.03 0.02 0.03 0.02

0.01 0.01 0.01 0.01 0.01

60°60°60° 60°60°

0°0°0°

96096012801280

320320640640

9601280

320640

60°

120°120° 120°120°

90°90° 90°90°

30°30° 30°30°

150°150° 150°150°

60°

120° 120°

90° 90°

30° 30°

150° 150°

0'

9'

9'

A B C D E21.3 34.2 23.6 35.4 12.0

3.82 6.13 4.23 6.34 2.88

0.80 1.29 0.89 1.34 0.70

0.21 0.34 0.24 0.35 0.20

0.08 0.12 0.09 0.13 0.07

0.03 0.06 0.04 0.06 0.03

0.02 0.03 0.02 0.03 0.02

Typical candlepower distribution curve for 100 Watt PMH

Typical candlepower distribution curve for 100 Watt PMH

A 70W PMH, ED-17 Med. Base, Coated, 5300 initial lumensB 100W PMH, ED-17 Med. Base, Coated, 8500 initial lumensC 70W HPS, ED-17 Med. Base, Coated, 5860 initial lumensD 100W HPS, ED-17 Med. Base, Coated, 8800 initial lumensE 42W PL-T, GX24q-4 Base, 3200 initial lumens

LE1/2/3 Luminaire

03'6'9'12'15'18'21'

3'

6'

12'

15'

18'

21'

3'

6'

0'

9'

9'

12'

15'

18'

21'

PATH SIDE0°0°

25255050

7575100100

HOUSE SIDE

120°120° 120°120°

90°90° 90°90°

60°60° 60°60°

30°30° 30°30°

150°150° 150°150°

2550

75100

120° 120°

90° 90°

60° 60°

30° 30°

150° 150°

LE1/2/3 Luminaire with LED Module

Typical candlepower distribution curve for 30 Watt LED

1.002.002.001.0000.500.200.10.050.020.01

Typical Half for 30 Watt LED

Initial Horizontal Footcandles for42K" Bollard (39F" Light Center)

Typical Halffor 45 Watt LED

Initial HorizontalFootcandles for42K" Bollard(39F" Light Center)

Typical candlepower distribution curve for 45 Watt LED

0'3'6'9'12'15'18'21'

3'

6'

12'

15'

18'

21'

3'

6'

0'

9'

9'

12'

15'

18'

21'

0°PATH SIDE

0°0°

5050100100

150150

200200

HOUSE SIDE

60°60°

90°90°

120°120° 150°150°

30°30°

60°60°

90°90°

120°120°150°150°

30°30°0°

50100

150

20060°

90°

120° 150°

30°

60°

90°

120°150°

30°

5.005.00

1.000.500.200.100.05

0.02

0.01

2.00

Typical Halffor 60 Watt LED

Initial HorizontalFootcandles for42K" Bollard(39F" Light Center)

Typical candlepower distribution curve for 60 Watt LED

0'9'12'15'18'21'

12'

15'

18'

21'

9'

9'

12'

15'

18'

21'

66'' 33''6' 3'

33''

33''

66''

66''

00''

3'

3'

6'

6'

0'

0°0°PATH SIDE

100100200200

300300400400

100200

300400

HOUSE SIDE30°30° 30°30°

60°60° 60°60°

90°90° 90°90°

120°120° 120°120°150°150° 150°150°

100200

300400

30° 30°

60° 60°

90° 90°

120° 120°150° 150°

10.05.002.001.000.500.200.100.05

0.02

IES Type1 IES Type3 IES Type 5

Era® Lantern Bollard

Lamp Guide

KIM LIGHTING 5

70 PMH 90 Coated, ED17, Med Base 6,200 16,000 M98 -30C HX-HPF 120 0.85 1.90 0.80 46,600 M143 208 0.52 1.00 0.50 3

240 0.44 0.90 0.43 2277 0.39 0.80 0.39 2347 0.28 0.70 0.20 2

100 PMH 129 Coated, ED17, Med Base 9,000 16,000 M90 -30C HX-HPF 120 1.15 2.30 1.20 6M140 208 0.66 1.40 0.80 4

240 0.58 1.15 0.65 3277 0.50 1.00 0.60 3347 0.40 1.00 0.40 2

70 HPS 91 Coated, ED17, Med Base 6,300 24,000 S62 -40C HX-HPF 120 0.81 1.45 0.75 5208 0.47 0.85 0.45 3240 0.40 0.75 0.37 2277 0.35 0.65 0.35 2347 0.30 0.55 0.30 2

100 HPS 130 Coated, ED17, Med Base 9,500 24,000 S54 -40C HX-HPF 120 1.15 2.20 1.30 7208 0.67 1.25 0.75 5240 0.58 1.10 0.65 3277 0.50 0.85 0.60 3347 0.39 0.70 0.45 3

42 PL 46 Coated, GX24q-4 Base 3,200 12,000 N/A -18C Electronic 120 – – 0.39 2208 – – 0.23 2240 – – 0.20 2277 – – 0.17 2

30 LED 30 LED 1,200 50,000+ N/A -40C Electronic 120 – – 0.25 2277 – – 0.11 2

45 LED 45 LED 1,800 50,000+ N/A -40C Electronic 120 – – 0.38 2277 – – 0.16 2

60 LED 60 LED 2,400 50,000+ N/A -40C Electronic 120 – – 0.50 2277 – – 0.22 2

Life

(Ho

urs)

AN

SI

Co

de

Sta

rtin

gTe

mp

Cir

cuit

Type

Vo

ltag

e

Lam

pW

atts

Lam

pTy

pe

Sys

tem

Wat

t

Bul

bTy

pe

Init

ial

Lum

ens

Ope

rati

ngA

mps

.

Ope

nC

ircu

itA

mps

.

Sta

rtin

gA

mps

.

Min

.Fus

eA

mps

.

All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturer’s data for exact lumen and life data.NOTE: For lamp/ballast information outside of the U.S.A and Canada, please consult your local Kim representative. Lamps by others.WARNING: All fixtures must be grounded in accordance with national, state, and/or local electrical codes. Failure to do so may result in serious personal injury.

HIGH PRESSURE SODIUM

COMPACT FLUORESCENT

LED – 75CRI, 3500K

PULSE START METAL HALIDE

Additional Era® Lantern luminaires are available from Kim Lighting.Request Kim Lighting’s Era LanternCatalog from your local Hubbell Lighting representative, or visit www.kimlighting.com.

Kim Lighting’s entire line-up of architecturally relevant outdoor lighting catalogs are available online atwww.kimlighting.com and in a two binder set.

Because of a continuingproduct improvement program,Kim Lighting reserves the right to change specifications without notice.

www.kimlighting.com

Era® Lantern Bollard


Recommended