TCP’s LED Linear High Bay features a stylish curved design and provides exceptional light distribution for mounting heights up to 60 feet. This durable, robust fixture efficiently delivers over 130 LPW of bright, white, uniform light to maximize energy savings and utility rebates. The long 50,000 hour rated life significantly decreases maintenance labor and material costs over the life of the fixture. A 0-10V dimming driver comes standard, enabling easy integration with a variety of controls options. • Energy efficient – Up to 70% energy savings compared to HID • Smooth, uniform dimming (0-10V) • Instant on, no warm up time for full light • Long life: 50,000 hours • Replaces traditional metal halide and linear fluorescent high bay systems • Durable 22 gauge housing is code grade steel • Perfect for uses in: - Warehouses & Distribution Centers - Commercial Facilities - Aisles (Open & Stock) - Retailers - Schools & Municipalities - Field Houses & Gymnasiums - Open Ceiling Designs LED IB Series High Bay by *Five year warranty for units with emergency backup Great Features/Benefits
Transcript
  • TCP’s LED Linear High Bay features

    a stylish curved design and provides

    exceptional light distribution for mounting

    heights up to 60 feet.

    This durable, robust fixture efficiently

    delivers over 130 LPW of bright, white,

    uniform light to maximize energy savings

    and utility rebates. The long 50,000

    hour rated life significantly decreases

    maintenance labor and material costs

    over the life of the fixture.

    A 0-10V dimming driver comes

    standard, enabling easy integration with

    a variety of controls options.

    • Energy efficient – Up to 70% energy savings compared to HID

    • Smooth, uniform dimming (0-10V)

    • Instant on, no warm up time for full light

    • Long life: 50,000 hours

    • Replaces traditional metal halide and linear fluorescent high bay systems

    • Durable 22 gauge housing is code grade steel

    • Perfect for uses in:

    - Warehouses & Distribution Centers

    - Commercial Facilities

    - Aisles (Open & Stock)

    - Retailers

    - Schools & Municipalities

    - Field Houses & Gymnasiums

    - Open Ceiling Designs

    LED IB Series High Bay

    by

    *Five year warranty for units with emergency backup

    Great Features/Benefits

    For more information on the quality and care TCP can deliver, call us at 800.324.1496 or visit tcpi.com325 Campus Dr. | Aurora, Ohio 44202 | P: 800.324.1496 | F: 877.487.0516

  • WarrantyFive year limited warranty against defects in manufacturing.

    Features/BenefitsUp to 70% less energy thanHID alternatives.

    Instant energy savings; potential rebate eligibility.

    Long 50,000 hours rated life. Minimizes replacements & maintenance costs.

    Very low heat generation. Less energy wasted as heat.

    UL approved for damp locations. Can be used outdoors when protected from elements. Withstands humidity indoors/outdoors.

    Replacement ComparisonTYPE WATTAGE ENERGY SAVINGS (%)

    TCP LED Linear High Bay - 13,500 lumens 105W —

    250W Metal Halide 295W 64%

    6 Lamp T8 HBF 220W 52%

    4 Lamp T5 HO 249W 58%

    TCP LED Linear High Bay - 27,300 lumens 210W —

    8 Lamp T5HO 482W 56%

    400W Metal Halide 458W 54%

    10 Lamp T8 HB 366W 43%

    SpecificationsInput Line Voltage 120-277 VAC

    Input Power 105W (13,500L), 150W (19,500L), 210 (27,300)

    Input Line Frequency 50/60HZ

    Luminaire Life (Rated) 50,000 hours

    Controls 0-10V dimming (standard)

    Minimum Starting Temperature -20°C (-4°F)

    Maximum Operating Temperature 40°C (104°F)

    CRI >80

    Power Factor >0.9

    THD

  • ApplicationsThe TCP LED IB Series High Bay is ideal for replacing traditional metal halide and linear fluorescent high bay systems. Benefits include high efficiency, excellent color rendering, long life, instant on, and improved uniformity. Suggested mounting heights up to 60’ with primary applications including warehousing, commercial facilities, manufacturing facilities, open and stack aisle applications.

    Construction • Housing: durable 22 gauge steel • Finish: powder coated, post-painted white • Large wiring compartment and multiple knock-outs to accommodate lighting controls • Stylish curved design

    Electrical • cULus damp location rated • 0-10V dimming driver (standard) • Easy-to-access wiring compartment • System rated for long 50,000 hour life • Efficiently delivers >130 LPW

    Optics • High impact, frosted white acrylic lens comes standard to protect the LEDs and minimize glare • Delivers bright, white light and excellent uniformity

    OCCUPANCY SENSORSLS1 – Leviton Occupancy Sensor w/bracket and interchangeable lenses, 40' or less, 120V, 277V, or 347VLS1D – Leviton Occupancy Sensor w/ Daylight Harvesting – PIR, 40’ or less, 120V-277V

    10C – 10' PCord 277V SJTOOW NO PLUG

    1Approximate lumen output. Actual performance may vary based on CCT, options selected and end user application.2Actual wattage may differ by +/- 10%.

    1IESNA TM-21-11 projected value based on 6X IESNA LM-80-08 total test duration of 6,000 hours.2IESNA TM-21-11 calculated value exceeds 6X IESNA LM-80-08 total test duration of 6,000 hours.

    Lumen Maintenance Factor (LMF)1

    Item # 36,000 hours1

    IB2UZDA1 91.40%

    IB2UZDA2 90.64%

    IB2UZDA3 91.40%

    Lumen Maintenance

    Catalog Ordering Matrix Examples: IB3UZDA350K IB ZD A3

    FAMILY VOLTAGE CONTROLS/DIMMING LUMEN PACKAGE (Power)12COLOR

    TEMPERATURE OPTIONS

    IB2 – LED Linear High Bay U – 120V - 277V ZD – 0-10V DimmingA1 – 13,500 lumens (105W)A2 – 19,500 lumens (150W)A3 – 27,300 lumens (210W)

    40K – 4000K50K – 5000K (see below)

    ListingsUL and cUL listedRoHS CompliantDLC 4.4 Premium

    WarrantyFive year limited warranty against defects in manufacturing.

    FACTORY INSTALLED OPTIONS (add to catalog number)

    CORD OPTIONS

    LED TECHNICAL DATA

    TCP® | 325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com

    LED IB Series High Bay Item NumberNotes Type

  • 0

    30

    60

    90

    120

    150

    -/+180

    -150

    -120

    -90

    -60

    -30

    UNIT: cdC0/180, 102.3 degC90/270, 101.5 deg

    AVERAGE BEAM ANGLE (50%): 101.9 DEG

    0

    1100

    2200

    3300

    4400

    5500

    Photometric Report

    Efficiency (total)Spacing Criterion (0-180)Spacing Criterion (90-270)

    127.861.191.19

    AAI Figure

    Flux out : 9123 lm

    1281, 3585 lx 298.20 cm

    489.17cm

    733.76 cm

    978.34 cm

    1222.93 cm

    1.219m

    2m

    3m

    4m

    5m

    Note: The Curves indicate the illuminated area and the average illumination when theluminaire is at different distance.

    476.1, 1332 lx

    211.6, 592.1 lx

    119.0, 333.1 lx

    76.17, 213.2 lx

    Height Eavg, Emax Angle: 101.45 deg Diameter

    Photometric Report – LED IB Series High Bay Luminaire

    Coefficient of Utilization Table Effective Floor Cavity Reflectance = 20%

    pcc 80% 70% 50% 30% 10% 0

    pW 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0

    pfc 20% 20% 20% 20% 20% 0

    RCR RCR: Room Cavity Ratio Coefficients of Utilization (CU)

    0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0

    1.19 1.19 1.19 1.05 1.00 0.97 0.92 0.85 0.79 0.81 0.73 0.67 0.72 0.63 0.57 0.64 0.56 0.49 0.58 0.49 0.43 0.53 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.41 0.33 0.28

    1.16 1.16 1.16 1.02 0.99 0.95 0.90 0.84 0.79 0.79 0.72 0.66 0.70 0.62 0.56 0.63 0.55 0.49 0.57 0.49 0.43 0.52 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.40 0.33 0.28

    1.11 1.11 1.11 0.98 0.95 0.92 0.86 0.81 0.77 0.76 0.70 0.65 0.68 0.61 0.55 0.61 0.54 0.48 0.55 0.48 0.42 0.50 0.43 0.38 0.46 0.39 0.34 0.43 0.36 0.31 0.39 0.33 0.28

    1.06 1.06 1.06 0.94 0.92 0.89 0.83 0.79 0.75 0.73 0.68 0.64 0.66 0.60 0.55 0.59 0.53 0.48 0.54 0.47 0.42 0.49 0.42 0.37 0.45 0.38 0.34 0.42 0.35 0.30 0.39 0.32 0.28

    1.02 1.02 1.02 0.90 0.88 0.87 0.80 0.76 0.73 0.71 0.66 0.62 0.63 0.58 0.54 0.57 0.52 0.47 0.52 0.46 0.42 0.48 0.42 0.37 0.44 0.38 0.33 0.40 0.35 0.30 0.38 0.32 0.28

    0.00 0.85 0.71 0.60 0.52 0.45 0.40 0.35 0.31 0.28 0.26

    LED TECHNICAL DATA

    LED IB Series High Bay

    IB2UZDA150K

    TCP® | 325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com

  • 0

    30

    60

    90

    120

    150

    -/+180

    -150

    -120

    -90

    -60

    -30

    UNIT: cdC0/180, 102.3 degC90/270, 101.5 deg

    AVERAGE BEAM ANGLE (50%): 101.9 DEG

    0

    1500

    3000

    4500

    6000

    7500

    Photometric Report

    Efficiency (total)Spacing Criterion (0-180)Spacing Criterion (90-270)

    N.A.1.301.38

    AAI Figure

    Flux out : 12492 lm

    1754, 4911 lx 298.41 cm

    489.52 cm

    734.28 cm

    979.04 cm

    1223.80 cm

    1.219m

    2m

    3m

    4m

    5m

    Note: The Curves indicate the illuminated area and the average illumination when theluminaire is at different distance.

    651.9, 1825 lx

    289.7, 811.1 lx

    163.0, 456.2 lx

    104.3, 292.0 lx

    Height Eavg, Emax Angle: 101.49 deg Diameter

    Coefficient of Utilization Table Effective Floor Cavity Reflectance = 20%

    pcc 80% 70% 50% 30% 10% 0

    pW 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0

    pfc 20% 20% 20% 20% 20% 0

    RCR RCR: Room Cavity Ratio Coefficients of Utilization (CU)

    0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0

    1.19 1.19 1.19 1.05 1.00 0.97 0.92 0.85 0.79 0.81 0.73 0.66 0.72 0.63 0.57 0.64 0.56 0.49 0.58 0.49 0.43 0.53 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.41 0.33 0.28

    1.16 1.16 1.16 1.02 0.99 0.95 0.90 0.84 0.78 0.79 0.72 0.66 0.70 0.62 0.56 0.63 0.55 0.49 0.57 0.49 0.43 0.52 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.40 0.33 0.28

    1.11 1.11 1.11 0.98 0.95 0.92 0.86 0.81 0.77 0.76 0.70 0.65 0.68 0.61 0.55 0.61 0.54 0.48 0.55 0.48 0.42 0.50 0.43 0.38 0.46 0.39 0.34 0.43 0.35 0.31 0.39 0.33 0.28

    1.06 1.06 1.06 0.94 0.92 0.89 0.83 0.79 0.75 0.73 0.68 0.64 0.66 0.60 0.55 0.59 0.53 0.48 0.54 0.47 0.42 0.49 0.42 0.37 0.45 0.38 0.34 0.41 0.35 0.30 0.39 0.32 0.28

    1.02 1.02 1.02 0.90 0.88 0.87 0.80 0.76 0.73 0.71 0.66 0.62 0.63 0.58 0.54 0.57 0.52 0.47 0.52 0.46 0.42 0.48 0.42 0.37 0.44 0.38 0.33 0.40 0.35 0.30 0.38 0.32 0.27

    0.00 0.84 0.71 0.60 0.52 0.45 0.40 0.35 0.31 0.28 0.26

    IB2UZDA250K

    LED TECHNICAL DATA

    LED IB Series High Bay

    TCP® | 325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com

  • Photometric Report AAI Figure

    Coefficient of Utilization Table Effective Floor Cavity Reflectance = 20%

    pcc 80% 70% 50% 30% 10% 0

    pW 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0

    pfc 20% 20% 20% 20% 20% 0

    RCR RCR: Room Cavity Ratio Coefficients of Utilization (CU)

    0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0

    1.19 1.19 1.19 1.05 1.00 0.97 0.92 0.85 0.79 0.81 0.79 0.66 0.72 0.62 0.57 0.64 0.56 0.49 0.55 0.49 0.42 0.53 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.41 0.33 0.28

    1.16 1.16 1.16 1.02 0.99 0.95 0.90 0.84 0.78 0.79 0.72 0.66 0.70 0.62 0.56 0.63 0.55 0.49 0.57 0.49 0.42 0.52 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.40 0.33 0.28

    1.11 1.11 1.11 0.98 0.95 0.92 0.86 0.81 0.77 0.76 0.70 0.65 0.68 0.61 0.55 0.61 0.54 0.48 0.55 0.48 0.42 0.50 0.43 0.38 0.46 0.39 0.34 0.43 0.36 0.31 0.39 0.33 0.28

    1.06 1.06 1.06 0.94 0.92 0.89 0.82 0.79 0.75 0.79 0.68 0.64 0.66 0.60 0.55 0.59 0.53 0.46 0.54 0.47 0.42 0.49 0.42 0.37 0.45 0.38 0.34 0.42 0.35 0.30 0.39 0.32 0.28

    1.16 1.16 1.16 1.02 0.99 0.95 0.90 0.84 0.78 0.79 0.72 0.66 0.70 0.62 0.56 0.63 0.55 0.49 0.57 0.49 0.42 0.52 0.44 0.38 0.48 0.40 0.34 0.44 0.36 0.31 0.40 0.33 0.28

    0.00 0.84 0.71 0.60 0.52 0.45 0.40 0.35 0.31 0.28 0.26

    IB2UZDA350K

    LED TECHNICAL DATA

    LED IB Series High Bay

    TCP® | 325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com

    0

    30

    60

    90

    120

    150

    -/+180

    -150

    -120

    -90

    -60

    -30

    UNIT: cdC0/180, 102.6 degC90/270, 102.1 deg

    AVERAGE BEAM ANGLE (50%): 102.5 DEG

    0

    2606

    5212

    7818

    10424

    13030

    Flux out : 9013 lm

    1266, 3542 lx 297.99 cm

    488.82 cm

    733.23 cm

    977.65 cm

    1222.06 cm

    1.219m

    2m

    3m

    4m

    5m

    Note: The Curves indicate the illuminated area and the average illumination when theluminaire is at different distance.

    470.3, 1316 lx

    209.0, 585.1 lx

    117.6, 329.1 lx

    75.25, 210.6 lx

    Height Eavg, Emax Angle: 101.41 deg Diameter

    Efficiency (total)Spacing Criterion (0-180)Spacing Criterion (90-270)

    N.A.1.301.38

  • Dimensions

    23.8”

    12.6”

    2.3”

    LED TECHNICAL DATA

    LED IB Series High Bay

    325 Campus Dr. | Aurora, Ohio 44202 | P: 800-324-1496 | tcpi.com

    ©TCP SEPT 2019/WF167756

    we know light.™

  • C R E A T I N G B E A U T Y

    For more information on the quality and care TCP can deliver, call us at 800.324.1496 or visit tcpi.com325 Campus Dr. | Aurora, Ohio 44202 | P: 800.324.1496 | F: 877.487.0516

    TCP has a 20-year history in energy-efficient lighting.

    Thanks to our cutting edge technology and manufacturing

    expertise, we have shipped billions of high quality lamps. Our

    integrated technology and manufacturing provides

    expedited time-to-market. With TCP, you can count on

    unique lighting products designed to meet very specific needs—lighting that

    transforms your surroundings and envelopes you in warmth—lighting

    that generates beauty with every flip of the switch.


Recommended