Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration
Transcript
Page 1: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Lenel OnGuard and Bioscrypt V-SmartCONFIGURATION GUIDE

-Veriadmin configuration

-OnGuard configuration

Page 2: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Overview

Using a biometric/smartcard reader connected to a reader port in 1320, 1300 and 2220. 

Biometrics are previously encoded in the card in OnGuard

The reader “reads” the biometrics from the card, compares against the finger placed and send the Wiegand that belong to the card trough the Wiegand port

Page 3: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Connection Diagram

Page 4: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

If you are configuring a new unit, the Network Setup screen will automatically be displayed. Click

[OK] to access the Network Configuration Manager. If this screen is not automatically displayed, from

the Configure menu, select Network Setup.

Veriadmin Configuration

Page 5: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Click “ADD UNIT” to get the reader online.

The next step is Advanced Botton, it is displayed the Unit Parameters

Veriadmin Configuration

Page 6: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Unit Parameter Settings

From the Configure menu, select Unit Parameters

The Unit Parameter Settings window appears.

a. The General tab displays the product, firmware, communication, and template information for the

current reader.

On the Communication tab, assign the network ID, select port mode and baud rate. Select Enable

Port. The settings for an enrollment reader are shown in the picture.

Veriadmin Configuration

Page 7: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

From the Configure menu, select LED Table Settings.

Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings

for the V-Smart reader as shown in the following screenshots

Page 8: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

From the Configure menu, select LED Table Settings.

Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings

for the V-Smart reader as shown in the following screenshots

Page 9: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

From the Configure menu, select LED Table Settings.

Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings

for the V-Smart reader as shown in the following screenshots

Page 10: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

On the Biometrics tab,

– Change the Global Security Threshold to Very High

– Make sure that the Biometric Verification is Enabled, and that Finger Required (under

Template Security) is selected.

– Select the number of fingers required and enter the Inter-Finger Timeout in seconds.

– If you wish, you may enable Password Verification (this will only apply to V-Station-G and VStation-

H units).

Page 11: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

On the Wiegand tab, set the Pass-Thru Format. Enable Input and Selective Output under Wiegand

I/O.

This format is not in the Bioscrypt reader, in order to upload it, click on Upload custom format and find it in “OnGuard Supplemental Materials disk (disk 2/2)” under the following directory:

Disco 2:\OEM Access Control\Bioscrypt Components\Software\ Lenel64.wgf

Page 12: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

Smart Card Settings

Configure the Smart Card settings via the Smart Card Manager. This is accessed by clicking the smart

card button in the toolbar. For Reader Type, the smart card technology (MIFARE or iCLASS) should be

stated here.

Page 13: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

Click [Security Settings] to configure the smart card security settings.

Note that all units should be configured to these specifications for the Smartcard Administrator

SiteKey:

– Primary SiteKey: C5RH9kVI7yDzSQu

– Secondary SiteKey: blank

– “Use software HASH” should NOT be selected

After typing in the site key, click [Change SiteKey].

A confirmation message will be displayed. Click [Accept].

You will be asked to enter the current sitekey. If you have a brand new reader, there is no sitekey

assigned yet and you may leave this field blank. Otherwise, enter the current sitekey.

Click [SAVE Settings].

Page 14: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

Veriadmin Configuration

For iCLASS readers, cards should already be encoded. If you require encoding, use an iCLASS encoder

for the enrollment workstation. Using Bioscrypt tools will create a 1K card, which is not practical.

Page 15: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Access Control Readers

Click (Add reader) , type a reader name, select the typo reader (ej. Dual interface Rdr 2 (wiegand / Prox).

Select Reader Modes and choose online and offline cases.

Page 16: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Workstations

Add a new workstation , click Browse and select the workstation form the network

Page 17: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Encoders/Scanners

Creat a new encoder , select the workstation that you added , device type select V-Smart (iCLASS)

Credential technology select iCLASS

Page 18: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Card Format

Select Add card format , application is V-smart (iCLASS)

Access Control card format select wiegand 64

SiteKey: C5RH9kVI7yDzSQu (same as configured ver reaeder inVeriadmin)

Click card Layout to check the configuration

Page 19: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Card Format

Here you have to check if the configuration is correct

Page 20: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Card Format

Add this card format following this configuration showed in the picture

Page 21: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Badge Type

Creat a new encoder , select the workstation that you added , device type select V-Smart (iCLASS)

Credential technology select iCLASS

Page 22: Lenel OnGuard and Bioscrypt V-Smart CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration.

OnGuard Configuration

SYSTEM ADMINISTRATION

Cardholder

Create a new user, select the badge type you have added after you typed all the information select capture, add a biometric finger then click ok and select “ENCODE”


Recommended