LEVEL 3
Your survey
reportProperty address
4 Uplands Rd
Handsworth
Birmingham
|B21 8BP
Client's name
Sukhwinder Rana
Inspection Date
13th October 2021
Surveyor’s RICS number
0849864
3RICS Home Survey - Level 3
Contents
A About the inspection
B Overall opinion
C About the property
D Outside the property
E Inside the property
F Services
G Grounds
H Issues for your legal advisers
I Risks
J Energy matters
K Surveyor’s declaration
L What to do now
MDescription of the RICS Home Survey – Level 3 service
and terms of engagement
N Typical house diagram
RICS disclaimer
The RICS Home Survey – Level 3 is reproduced with the permission of the Royal Institution of
Chartered Surveyors, which owns the copyright. © 2021 RICS
RICS Home Survey - Level 3
AAbout the inspection and report
This RICS Home Survey – Level 3 has been produced by a surveyor, who has written this
report for you to use. If you decide not to act on the advice in this report, you do so at your
own risk.
Page 3RICS Home Survey - Level 3
About the survey
As agreed, this report will contain the following:
• a thorough inspection of the property (see 'The inspection' in section M) and
• a report based on the inspection (see 'The report' in section M).
About the report
We aim to give you professional advice to:
• help you make a reasoned and informed decision when purchasing the property, or when planning for repairs,
maintenance or upgrading the property
• provide detailed advice on condition
• describe the identifiable risk of potential or hidden defects
• propose the most probable cause(s) of the defects, based on the inspection
• where practicable and agreed, provide an estimate of costs and likely timescale for identified repairs and
necessary work, and
• make recommendations as to any further actions to take or advice that needs to be obtained before
committing to a purchase.
Any extra services we provide that are not covered by the terms and conditions of this report must be
covered by a separate contract.
About the inspection
• We carry out a desk-top study and make oral enquiries for information about matters affecting the property.
• We carefully and thoroughly inspect the property, using our best endeavours to see as much of it as is
physically accessible. Where this is not possible, an explanation will be provided.
• We visually inspect roofs, chimneys and other surfaces on the outside of the building from ground level and, if
necessary, from neighbouring public property and with the help of binoculars.
• We inspect the roof structure from inside the roof space if there is access. We examine floor surfaces and
under-floor spaces, so far as there is safe access and with permission from the owner. We are not able to
assess the condition of the inside of any chimney, boiler or other flues.
• If we are concerned about parts of the property that the inspection cannot cover, the report will tell you about
any further investigations that are needed.
• Where practicable and agreed, we report on the cost of any work for identified repairs and make
recommendations on how these repairs should be carried out. Some maintenance and repairs that we
suggest may be expensive.
• We inspect the inside and outside of the main building and all permanent outbuildings. We also inspect the
parts of the electricity, gas/oil, water, heating, drainage and other services that can be seen, but these are not
tested other than normal operation in everyday use.
• To help describe the condition of the home, we give condition ratings to the main parts (the ‘elements’) of the
building, garage, and some parts outside. Some elements can be made up of several different parts.
• In the element boxes in sections D, E, F and G, we describe the part that has the worst condition rating first
and then outline the condition of the other parts.
A
Page 4RICS Home Survey - Level 3
! Reminder
Please refer to your Terms and Conditions, that were sent to you at the point you Sukhwinder Rana
confirmed your instruction to us Shape Property Surveyors Ltd, for a full list of exclusions.
Page 5RICS Home Survey - Level 3
Date of the inspection Report reference number
13th October 2021 GJE131021B218BP
About the inspection
Surveyor's name
Gary Edwards MA MRICS
Surveyor’s RICS number
0849864
Company name
Shape Property Surveyors Ltd
Related party disclosure
The valuer and indeed Shape Surveyors does not have any involvement with either the financial disposal
of the property inspected or indeed the vendors.
The Valuer is an 'External Valuer' in accordance with the definitions set out by the Royal Institution of
Chartered Surveyors.
Furthermore, we are not aware that there is any conflict of interest as defined in the RICS Valuation
standards and the RICS Rules of Conduct. We can confirm that to be best of our knowledge and based on
our records and enquiries we are not aware of any associated link with this property transaction and do not
believe we have any conflict of interest.
We can also confirm that to the best of our knowledge we have not had any previous dealings with this
property. As far as we are aware there are no conflicts of interest as defined in relevant RICS
documentation.
We have made no special assumptions within our report or valuation unless specifically stated within the
relevant section of the report. Our main assumptions are stated within the agreed terms of engagement.
We have not been provided with any supporting legal searches, documentation or specialist reports that
relate to the subject property at the time of compiling this report. We will, however, happily review and
advise on any issues of concern raised by your legal adviser and offer guidance as to how best to proceed
where relevant.
Full address and postcode of the property
4 Uplands Rd
Handsworth
Birmingham
|B21 8BP
A
Page 6RICS Home Survey - Level 3
Weather conditions when the inspection took place
It was mild and dry at the time of inspection, having been preceded by a period of variable weather.
Status of the property when the inspection took place
At the time of inspection, the property was not occupied and was free of furniture and general items.
Floors were mainly covered with various floor coverings.
Page 7RICS Home Survey - Level 3
BOverall opinion
This section provides our overall opinion of the property, highlighting areas of concern, and
summarises the condition ratings of different elements of the property. If an element is
made up of a number of different parts (for example, a pitched roof to the main building
and a flat roof to an extension), only the part in the worst condition is shown here. It also
provides a summary of repairs (and cost guidance where agreed) and recommendations
for further investigations.
Important note
To get a balanced impression of the property, we strongly recommend that you read all
sections of the report, in particular section L, 'What to do now', and discuss this with us if
required.
Page 8RICS Home Survey - Level 3
Condition ratings
Overall opinion of property
The property is considered to be a reasonable proposition for purchase although there are a number of
defects which require immediate attention and which will require some expenditure at the outset. We would
not expect any particular difficulty on resale in normal market conditions, provided that the necessary
works are carried out to a satisfactory standard.
You should investigate the cost of these works prior to a commitment to purchase. Once known, you may
wish to re-negotiate the purchase price to reflect them.
It is very important that you read this report as a whole. In the main body of the report, we will notify you of
the actions that will be required prior to exchange of contracts. You must make sure that you have all of
the repairs needed investigated by reputable contractors so that you are fully aware of their scope and
financial implications before you purchase.
This report should be construed as a comment upon the overall condition of the property and is not an
inventory of every single defect. The report is based on the condition of the property at the time of our
inspection and no liability can be accepted for any deterioration in its condition after that date.
B
Page 9RICS Home Survey - Level 3
Documents we may suggest you request before you sign contracts
There are documents associated with the following elements. Check these documents have
been supplied by your solicitor before exchanging contracts.
3Elements that require urgent attention
These elements have defects that are serious and/or need to be repaired, replaced or
investigated urgently. Failure to do so could risk serious safety issues or severe long-term
damage to your property.
2Elements that require attention but are not serious or urgent
These elements have defects that need repairing or replacing, but are not considered to be
either serious or urgent. These elements must also be maintained in the normal way.
Condition ratings
To determine the condition of the property, we assess the main parts (the ‘elements’) of the building, garage
and some outside areas. These elements are rated on the urgency of maintenance needed, ranging from
‘very urgent’ to ‘no issues recorded’.
Element no. Document name Received
E3 Building Regulations Certificate for extension NO
F1 Electrical Inspection Condition Report NO
F2 Gas Safety Certificate NO
F4 Gas Boiler Service NO
Element no. Element name
E3 Walls and partitions
F1 Electricity
F2 Gas/oil
F4 Heating
F5 Water heating
Element no. Element name
D1 Chimney stacks
D2 Roof coverings
D3 Rainwater pipes and gutters
B
R
Page 10RICS Home Survey - Level 3
1Elements with no current issues
No repair is currently needed. The elements listed here must be maintained in the normal way.
NIElements not inspected
We carry out a visual inspection, so a number of elements may not have been inspected.
These are listed here.
Summary of repairs and cost guidance
Formal quotations should be obtained prior to making a legal commitment to purchase the
property.
Element no. Element name
D4 Main walls
D5 Windows
D6 Outside doors (including patio doors)
D8 Other joinery and finishes
E1 Roof structure
E4 Floors
E5 Fireplaces, chimney breasts and flues
E6 Built-in fittings (built-in kitchen and other fittings, not including appliances)
E7 Woodwork (for example, staircase joinery)
E8 Bathroom fittings
F3 Water
G3 Other
Element no. Element name
E2 Ceilings
Element no. Element name
F6 Drainage
Repairs Cost guidance (optional)
Chimney pot repair
Replace missing/slipped/cracked roof tiles to ridge and bay
Page 11RICS Home Survey - Level 3
Repairs Cost guidance (optional)
Repair bay gutter
External walls repairs and re-pointing
Replaces misted window units
Repair/replace front door
External joinery decoration
Damp proof / re-plaster walls
Repair floors
Repair/decorate internal joinery
Replace gas boiler
Release inspection chamber cover.
Gardens clearance and improvements
Further InvestigationsFurther investigations should be carried out before making a legal commitment to purchase the property.
Electrical safety inspection & test
Gas safety assessment & service
Page 12RICS Home Survey - Level 3
CAbout the property
This section includes:
• About the property
• Energy efficiency
• Location and facilities
Page 13RICS Home Survey - Level 3
Photo - 2 Photo - 3
About the property
Type of property
The property comprises a two storey three bedroom mid-terrace house.
Approximate year the property was built
The precise date of construction is unknown and should be confirmed by your Legal Adviser.
Approximate year the property was extended
A single storey extension has been added to the rear of the property and the date of this extension should
be confirmed by your Legal Adviser.
Details of the extension should be obtained by your Legal Adviser, together with evidence of all statutory
approvals and Completion Certificates.
Approximate year the property was converted
The property has not been converted.
Information relevant to flats and maisonettes
This property is not a flat or maisonette.
Construction
The property comprises traditional solid brick wall construction with a pitched tiled roof. Floors comprise
timber and solid construction and doors and windows comprise uPVC framed construction.
C
Page 14RICS Home Survey - Level 3
Accommodation
Living
roomsBedrooms
Bath or
shower
Separate
toiletKitchen
Utility
roomConservatory Other
Ground 2 1 1
First 3
Means of escape
At ground floor level, means of escape is possible through the doors to the front and rear of the property
and the opening lights to windows.
Assisted escape at first floor level is possible via the opening lights to the front and rear of the property.
Where opening lights are fitted with locks, keys should be kept close by so they can be opened at all
times.
Page 15RICS Home Survey - Level 3
Gas Electric Water Drainage
Gas Electric Solid fuel Oil None
Energy efficiency
We are advised that the property’s current energy performance, as recorded in the EPC, is as stated below.
We have checked for any obvious discrepancies between the EPC and the subject property, and the
implications are explained to you.
We will advise on the appropriateness of any energy improvements recommended by the EPC.
Energy efficiency rating
The current energy efficiency rating for the property is D63.
Issues relating to the energy efficiency rating
Please refer to the EPC for issues relating to the energy efficiency rating.
Mains services
A marked box shows that the relevant mains service is present.
Central heating
Other services or energy sources (including feed-in tariffs)
There are no other services or energy sources as far as we are aware.
Other energy matters
There are no other services or energy sources as far as we are aware.
C
Page 16RICS Home Survey - Level 3
Photo - 4 Photo - 5
Photo - 6
Location and facilities
Grounds
The property has a small front area and enclosed rear garden.
There is no garage to the property and vehicular parking is not possible on the property.
There appears to be a footpath across the rear garden which permits neighbours to access their rear
gardens. Your Legal Adviser should confirm the arrangements and implications.
Location
The property is located in a residential area amongst properties of a similar age and type.
Facilities
The property is situated within an established residential location convenient for all usual local amenities
and transport links.
C
Page 17RICS Home Survey - Level 3
Local environment
At the time of writing environmental survey reports were not available for comment upon. Should the
purchaser want to be sure of any particular environmental issues in respect of the subject premises and
surrounding area then they should instruct their legal agent to prepare/obtain appropriate environmental
survey reports. The surveyor would be pleased to provide outline comment in respect of any such
documentation as long as it was made available in a timely manner prior to completion of the sale. This
report and valuation are provided on the basis that there is no contamination or other adverse factors.
We are unaware of any adverse environmental issues connected with this property. However, reference
should be made to the environmental search provided by your Legal Advisers. This survey does not cover
potential issues arising from historic land uses or localised underground geological conditions.
Other local factors
We are not aware of any other detrimental factors locally that may adversely affect the property.
Page 18RICS Home Survey - Level 3
DOutside the property
Page 19RICS Home Survey - Level 3
NI321
The property is served by two brick built shared chimney stacks. Both stacks are shared with the
neighbouring property.
Stacks are weathered to the roof finish with lead flashings.
The chimney stacks are reasonably plumb and not leaning or curved to any significant extent. No
deflection or cracks were noted to suggest they are unstable.
The stacks appear to be in overall reasonable condition, requiring routine maintenance and
improvement works not considered unusual for their age. One chimney pot is leaning out of true
and this needs to be remedied as it may be unstable and pose a risk. Otherwise, no significant
defects were noted.
Open chimney pots can be blocked by nesting birds or allow rain penetration. Appropriate guarding
should be provided as a matter of priority. It cannot be assumed that connected flues are
functioning and open to the air and testing must be undertaken before use.
The capacity, condition and integrity of any flues and their layout within the chimney stacks could
not be verified and further upgrading and improvement in this regard may be necessary. Flues
should be tested at the same time as any gas appliance testing is undertaken.
When chimney flues serve no heating appliance or open fireplace they are considered to be
redundant. They should be topped by appropriate terminations which permit ventilation to the flues
and chimney breasts below.
It should be borne in mind that if works are required on the chimney stacks to the building,
scaffolding or other means of access may be required to undertake this work which can
significantly increase the cost of the initial repair.
2
Full detail of elements inspected
Limitations on the inspection
The external fabric of the building is inspected from ground level only except where it is possible to
observe elements of the building from higher levels such as windows and skylights and similar vantage
points.
It should, therefore, be remembered that whilst we inspect the building throughout there are always areas
that may not be visible. Typically rear pitched roofs and roof ridges when viewed from ground level cannot
be completely seen or closely inspected and therefore the condition not reported fully.
D1 Chimney stacks
D
Page 20RICS Home Survey - Level 3
Photo - 7 Photo - 8
It is essential that roof coverings are kept in good order to minimise the risks of water penetration
which can cause deterioration to roof timbers and damage to the interior of the property. Roofs can
be damaged during maintenance activities and by severe weather conditions. For safe access,
scaffolding is required for most roof repairs and this can be costly.
The main roof and wing roof are covered with artificial slates.
The original roof covering has been replaced and evidence of statutory approvals, which are
necessary for such works, should be obtained by your Legal Adviser.
The general shape of the main roof and the lack of any significant deflection or pronounced dishing
suggest there is no structural failure of the roof structure. A missing ridge tile was noted and
daylight is visible in the roof space. This tile needs to be replaced immediately. An artificial slate
was also noted to be missing and in need of replacement. The verge to the rear extension is also
in need of making good.
The front bay window roof is covered with plain clay tiles, a number of which are displaced and
damaged. It is suspected this roof is leaking. Immediate repairs are required and quotations should
be obtained from a reputable roofing contractor.
Otherwise, the roof coverings are in serviceable condition and no significant defects were noted.
No slipped or damaged slates were noted and ridges and verges are free from significant defect.
The canopy over the front window should be closely inspected and any necessary repairs
undertaken.
The roofs generally should be inspected regularly so if any slate or tile becomes detached it can be
replaced without delay.
Some areas of roof are affected by vegetative growth. This should be removed as part of ongoing
maintenance as it impedes drainage and can eventually obstruct gutters.
The wing roof is concealed from view so its condition cannot be ascertained. Internally, there was
no evidence of this roof leaking, however.
2
D2 Roof Coverings
Page 21RICS Home Survey - Level 3
Photo - 9 Photo - 10
Photo - 11 Photo - 12
Photo - 13 Photo - 14
Rainwater goods comprise standard domestic uPVC gutters which discharge rainwater via
downpipes attached to external walls.2
D3 Rainwater pipes and gutters
Page 22RICS Home Survey - Level 3
It is important that gutters are kept clean and free of any vegetation or debris at all times to ensure
free flow of surface water run-off from roofs. Regular inspections should therefore be undertaken
and shortly after taking up occupation you should arrange for the gutters to be cleaned, removing
all vegetation, which is clearly visible, and general debris. Leaking gutters and downpipes can
cause damage to the fabric of the building and cause damp stains to appear internally.
Vegetation was noted to the rear wing gutter and the stained brickwork below indicates this gutter
is overflowing. The extension gutter and bay window gutter are filled with debris. All gutters need to
be thoroughly cleaned out. A taped repair was noted to the front bay gutter and this section of
gutter should be replaced.
Otherwise, although it was dry at the time of inspection, the condition and arrangement of the
rainwater goods appears to be satisfactory. There was no evidence of failure of gutters or
downpipes and no evidence of leaking joints.
Although no significant staining to joints was noted to suggest serious leaks, because it was not
raining at the time of inspection, it cannot be categorically confirmed the system is free from
isolated leaks. It is recommended the system is inspected during a period of rainfall just to confirm
it is completely free from any leaks.
Photo - 15 Photo - 16
Photo - 17 Photo - 18
Page 23RICS Home Survey - Level 3
Photo - 19
The main walls comprise traditional solid brick construction of varying widths.
Walls generally are slightly deflected, out of square and not plumb and this is common for
properties of this age, as a result of the structure having moved and settled from the time it was
built. It is possible the original building was constructed with inadequate foundations so external
walls will inevitably experience differential movement over time.
Friable mortar joints and spalled bricks are evident and areas of brickwork are generally in poor
condition, particularly to the rear. Areas of poor quality repointing, which is failing, were noted. In
addition, brick on edge cills are deteriorating and in need of re-pointing and repair. Some making
good and maintenance is required. Removing and re-pointing friable mortar joints should be
undertaken as part of ongoing maintenance for the property.
The pebbledash finish applied to the front wall is affected by some minor cracks and damage,
which should be repaired as soon as possible. Quotations for repairs and decoration should be
obtained from a competent contractor, prior to purchase.
It is important that the render finish is maintained in sound condition into the future as failure here
can cause moisture to become trapped within the wall. This can penetrate into the interior and
cause damp staining, which will then be costly to resolve.
The painted front bay is in very poor condition and redecoration is required.
Properties of this age are unlikely to have full lintel support above the openings. As slight
settlement was noted above some of the openings, you should consider upgrading the support in
order to prevent problems with window frames and opening lights.
It was not possible to determine if a DPC (Damp Proof Course) has been incorporated in external
walls. Areas of high damp content were noted internally within the walls and this is detailed in the
F3 Walls and Partitions section below.
The external walls are of solid construction, unlike modern walls which have a cavity incorporated.
Solid walls are designed to absorb moisture up to a certain point and then to evaporate moisture
during dryer periods. A damp proof course at low level is intended to stop moisture from the ground
rising up through the brickwork. Rising damp (due to a failure or a lack of damp proof course) or
2
D4 Main walls
Page 24RICS Home Survey - Level 3
defective brickwork (i.e. spalled bricks or friable mortar joints) can cause walls to be come totally
saturated and this is when damp staining will occur internally.
There are some cracks to the rear elevation of the rear wing which require repair. Although not
symptomatic of serious structural movement, a contractor should be engaged to provide a
quotation for repairing cracks and making good brickwork above the ground floor extension. Some
re-pointing to high level brickwork is also required on the neighbour's side.
A row of plugs at low level indicate a chemical injection damp proof course has been installed at
some stage in the past. This indicates the property has been subject to remedial damp proofing
measures at some stage in the past and transferable and enforceable guarantees should be
obtained by your Legal Adviser.
Ground levels around the property are too high in areas and walls would benefit from a lowering of
ground levels generally in the proximity of external walls. It is good practice to maintain a 150mm
(two bricks) clearance between external levels and the damp courses to prevent possible bridging
and damp penetration. High ground levels also increase the possibility of surface water ingress,
particularly to vulnerable areas such as door openings.
Air bricks have been incorporated within the external walls and it is important these air bricks are
kept unobstructed.
Photo - 20 Photo - 21
Photo - 22 Photo - 23
Page 25RICS Home Survey - Level 3
Photo - 24 Photo - 25
Photo - 26 Photo - 27
Photo - 28 Photo - 29
Page 26RICS Home Survey - Level 3
Photo - 30 Photo - 31
Routine maintenance should always be anticipated to windows in the form of regular attention to
items such as: hinges, latches, locking mechanisms, framework, sills and glazing seal edges, etc.
This is something all homeowners should anticipate and budget for.
Windows comprise uPVC double glazed casement windows, being installed within the original
openings around the property.
All possible windows were opened and windows generally appear to be in functional condition. The
front living room window is badly cracked and needs to be re-glazed, however. Some opening
lights are snagging the frames and some locks and hinges are stiff to operate. Frames and
mechanisms are heavily soiled and would benefit from thorough cleaning, easing and adjusting
and servicing.
As the windows age, some repairs and maintenance will be necessary and this should be
budgeted for accordingly.
Misting was noted to some windows indicating these glazed units have failed and need to be
replaced.
Quotations should be obtained from a reputable contractor, prior to purchase, to refurbish and
service the existing windows and replace any defective sealed glazing units, hinge mechanisms,
seals and locks. Opening lights should also be adjusted to ensure they open and close freely.
When windows are removed to facilitate replacement units, a lack of adequate lintel support within
the wall can become apparent. Lintel upgrading would then be necessary and costs will increase.
2
D5 Windows
Page 27RICS Home Survey - Level 3
Photo - 32 Photo - 33
Photo - 34 Photo - 35
Photo - 36
As with windows, routine maintenance should always be anticipated to door joinery in the form of
regular attention to items such as: hinges, latches, locking mechanisms, framework, weatherboard
threshold strips and glazing seal edges, etc. This is something all homeowners should anticipate
2
D6 Outside doors (including patio doors)
Page 28RICS Home Survey - Level 3
and budget for. When taking up occupation, it is advisable to change the door locks. Unless egress
locks are fitted, all door keys should be kept readily available to allow for emergency escape.
External doors comprise uPVC composition.
Doors are ageing and in need of some attention. The front door has been damaged and crudely
repaired in an unsightly manner. Doors would also benefit from easing and adjusting to ensure
they do not foul on the frames or floor, in addition to servicing/cleaning of hinges and frames. The
glazed units have a limited life and may mist up under certain conditions.
Photo - 37
The property has no conservatory or projecting porch.
Other joinery comprises the fascias to the rear wing and extension, in addition to a canopy over the
front bedroom window and a canopy over the front door.
As with all exposed timber components, regular decoration is required in order to protect joinery
from premature decay and costly replacement. Good quality paint or stain applied in built up layers,
after suitable preparation, will greatly lengthen the life of external timbers. Five years is generally
considered to be the maximum recommended decoration cycle.
Joinery is exhibiting signs of deterioration and evidence of decay was noted. Decorations are
failing as a result of the decay which is affecting external joinery. Timbers require repairs and/or
replacement together with complete decoration after necessary timber treatments have been
applied.
Quotations for timber repairs and decoration should be obtained from a competent contractor prior
to purchase.
2
D7 Conservatory and porches
D8 Other joinery and finishes
Page 29RICS Home Survey - Level 3
Photo - 38 Photo - 39
Photo - 40 Photo - 41
There are no other matters requiring comment.
D9 Other
Page 30RICS Home Survey - Level 3
EInside the property
Page 31RICS Home Survey - Level 3
NI321
The roof space area is inspected as far as possible providing boarded or safe access is available.
When insulation is placed over joists or exposed joists lack suitable decking it is not possible to
enter into the roof space. In this instance, only a ‘Head and Shoulders’ level of inspection is
possible.
A small opening in the middle bedroom cupboard allows very limited visibility of the main roof
space. It is recommended a proper ceiling hatch is formed in an accessible location.
No safe access was possible within the main roof space, so a head and shoulders inspection was
undertaken. This involved an inspection of the roof space from the vicinity of the hatch, supported
by a ladder and assisted by torchlight.
The roof structure comprises a pitched roof which is cut and fabricated on-site as part of the
construction process. This framework has to be of sufficient strength to transmit the dead and
imposed loadings which are placed upon it, primarily from the weight of the covering and
additionally from snow and wind pressure, onto external and internal load-bearing walls without
undue distortion.
Roofing felt is installed below the roof covering, so there is a secondary line of defence against
penetrating rainwater.
An examination of the roof slopes was carried out from various locations to see if any movement in
the form of sag or other structural movement has occurred to the roof slopes that could be
attributed to a defect in the roof structure. Internally where access was possible an examination
was made of the structural timbers.
Viewed both externally and in addition to a limited internal inspection, the main roof structure
appears to be free from any signs of structural failure. Key areas, however, including rafter ends
and wall-plate junctions were not visible and improvements are recommended which would enable
a more frequent and comprehensive inspection of the roof structure to be undertaken.
Replacement purlins and rafters were noted together with additional timber strengthening braces
and struts. From within the roof void, it was possible to determine that the timbers are of
appropriate size and configuration to bear their dead and imposed loads. No signs of significant
deflection or movement were noted. Having regard to the age and style of structure ongoing
maintenance should be anticipated. As the roof structure and roof covering has been subject to
wholescale replacement, evidence of statutory approvals should be obtained.
2
Inside the property
Limitations on the inspection
At the time of inspection, the property was not occupied and was free of furniture. Floors were mainly
covered with a variety of floor finishes and coverings.
As much of the internal fabric of the building as possible will be inspected without opening up the structure
or causing damage or moving furniture and fittings.
E1 Roof structure
E
Page 32RICS Home Survey - Level 3
The roofing felt is largely in sound condition, with no significant disrepair noted. The roofing felt
beneath the roof covering fulfils an important function and is designed as a secondary barrier
against water ingress into the roof space. Over time, it can deteriorate – and the lower roof slope
where it meets the gutter is very vulnerable in this respect. Failure in this location can lead to long
tern moisture ingress which can affect external walls, rafters, wall plates and soffits. This
accumulating moisture is not readily detectable until well advanced and repair costs can be high as
a result. Roofing felt inspections should be undertaken regularly and any if any damp or disrepair is
noted a competent roofing contractor should be engaged to undertake any necessary repairs.
Instances of daylight are visible through the roof covering and this indicates the roof is not
watertight. This has been referred to in the Roof coverings section above.
Current Building Regulations require insulated and felted roofs to be ventilated to prevent
condensation within the roof void. In severe cases, a lack of ventilation can result in decay to
timbers. We would recommend that you upgrade roof space ventilation provision so as to prevent
moisture build up within the wider building fabric.
Other than some unsupported pipework ,no defects were noted in the extension roof space.
Photo - 42 Photo - 43
Photo - 44 Photo - 45
Page 33RICS Home Survey - Level 3
Photo - 46 Photo - 47
Photo - 48 Photo - 49
Ceilings have been inspected from within the rooms and no formal opening up has been
undertaken.
It is not always possible to determine the construction of a ceiling through a visual inspection. It
may, therefore, be found that during decoration or improvements that some ceilings will require
unforeseen replacements or more extensive repairs than anticipated.
Ceilings are free from structural cracks and any serious defects. On-going maintenance and
decoration is required to maintain them in reasonable condition.
It is common for ceilings to be affected by random minor cracks. These can be caused by general
plaster shrinkage, or moisture and thermal changes in the air. In addition, cracks can also be
caused by relative movement of the timber floor or roof joists and plasterboards. These types of
cracks are common in a property of this age and type and do not give cause for concern. They
should be made good as part of routine maintenance and decoration.
1
E2 Ceilings
Page 34RICS Home Survey - Level 3
Photo - 50
An examination of all of the internal walls was undertaken to determine if there is any failure or
defects in the supporting nature of the walls or any defects in plaster surfaces. A particular
examination was made where possible to determine which are the load bearing walls. The ground
floor walls were checked for any sign of damp, foundation failure or, where possible, failure of the
sub floor support.
Before you undertake any repairs or maintenance on internal walls you should ensure that you
verify whether the walls are load bearing or not and also if there are any concealed pipes or
electric cables within the body of the wall or partition. If in doubt always seek specialist advice.
It is not possible to categorically state the type of construction or structural function of internal walls
without intrusive examination so no assumptions should be made regarding the composition of an
internal wall or partition without such an examination.
Internal walls comprise mainly plastered masonry construction and lightweight partitions and have
the usual decorative finishes.
The walls within the property are generally free from abnormal damage and irregularities and no
significant defects were noted at the time of inspection. Periodic decoration and ongoing
maintenance is required.
There is some movement to the internal partition walls evidenced, for example, by distortion to
door frames at first floor level. It is common for walls and partitions to move gradually over time as
the building structure settles slowly over time. This can cause a degree of distortion to walls and
partitions internally and the effect is often seen affecting door heads which can become quite
distorted. This movement shows no signs of any recent progression and is considered to be within
acceptable tolerances for a property of this type and age.
Many areas of blown, uneven and defective plaster were noted and the need for significant areas
of re-plastering, prior to decoration, should be budgeted for.
The property has solid brick walls which were designed to resist the passage of damp without
modern damp proof courses or the benefits of cavity wall construction. Inevitably, when tested with
a damp meter, these solid walls record significantly higher damp content when compared to
modern walls. This has to be accepted as a characteristic of buildings of this age. Levels of damp
3
E3 Walls and partitions
Page 35RICS Home Survey - Level 3
are considered to be unacceptable when damp staining occurs internally or when plaster surfaces
become friable, detached or cracked.
Significant dampness was detected at a low level to the walls to the front chimney breast, hall,
kitchen and WC. Damp staining and efflorescence is visible to a low level area of wall by the
kitchen door opening. This pattern of dampness usually signifies Damp Proof Course (DPC)
failure. Remedial treatment of this type often involves the removal of large areas of plaster and re-
plastering internally so that the company guarantees are effective. Where there are built-in fittings
such as kitchen units, damp proofing can be costly and inconvenient to rectify.
Further specialist investigation to the whole property is required prior to exchange of contracts.
Any floor timbers which are in contact with damp masonry are at risk from rots and decay these
should be inspected by the specialist firm so they can carry out appropriate remedial treatment/
repairs as required.
It is recommended that a Timber and Damp Report for the whole property is obtained from a
member of the Property Care Association. All recommendations should be followed and costs
budgeted for.
Photo - 51 Photo - 52
Photo - 53
Page 36RICS Home Survey - Level 3
There are always practical limitations on the inspections of floors, whether exposed or covered by
fitted coverings and furniture. Floorboards are not lifted unless they are exposed and not secured.
If there is any evidence that concealed defects may exist then this is reported.
Floors were completely covered with fitted carpet and other floor finishes at the time of inspection.
The floors to the property are believed to be of a part solid and part suspended timber construction,
with solid and suspended timber construction noted to the ground floor and suspended timber
construction noted to the first floor.
The suspended timber floors generally are showing general signs of loose and uneven floorboards
and further securing and improvement is necessary. Immediate repairs are required to the timber
floors, which will need to be exposed, in order to bring them back to a smooth and level finish.
In view of the damp levels noted within the property, it is necessary to expose ground floor timbers
and check for the presence of any rots decay or infestation. This should be part of the damp and
timber inspection required for the property. Quotations for any remedial works required should be
obtained prior to purchase.
The solid ground floor to the property is uneven and irregular and there may be no damp proof
membrane incorporated within the floor structure. It is quite possible the only resistance to damp is
provided by the floor finishes themselves and this would only become evident when replacing such
floor finishes. It is recommended that you instruct a competent contractor to determine the
condition and composition of the solid ground floors, and make any recommendations for
improvements.
It is important for the space beneath the surface of a suspended timber ground floor to be
adequately ventilated. This is to ensure that there is an adequate flow of air around the timbers
which keeps them dry and reduces the risk of rot and decay. It is important, therefore, to ensure
that air bricks, usually provided at the low level in the external walls, are kept completely clear at all
times and protected from any possible moisture ingress.
2
The property has no chimney breasts with flues or built in fireplaces.
Fireplaces and flues have not been formally tested. Visual observations are made only. We cannot,
therefore, guarantee the functionality of fireplaces or their flues and where relevant these should
be fully checked and tested by a suitably qualified specialist contractor.
You should also verify historic service records of any associated heating appliances (whether oil,
solid fuel or gas fired) via your legal adviser in due course. These units should not be used without
professionally checking/testing the flue arrangements first. Existing flues may require significant
upgrading, possibly including re-lining or replacement, which is costly.
Where original open fireplaces have been sealed off, these redundant flues should always be
ventilated internally and terminated at the top with a suitable flue termination. This should help to
prevent any build-up of damp penetration or moisture within the flue voids/masonry.
Chimneys and flues can deteriorate allowing combustion gases to leak into other rooms and
spaces creating a health hazard. It is not possible to assess the condition of flues or the presence
or type of flue liners by visual inspection. In addition, flue liners are designed for gas fires or solid
2
E4 Floors
E5 Fireplaces, chimney breasts and flues
Page 37RICS Home Survey - Level 3
fuel burners but not both.
It is imperative that current safety regulations are met and appliances and tested to ensure they
are in safe condition. This must be undertaken by a suitably qualified person, which, in the case of
gas appliances, is a Gas Safe Registered Contractor. The contractor should also confirm that
adequate ventilation has been provided to all appliances. All tests must be undertaken before any
appliances are used.
Two chimney breasts extend from the ground floor to the chimney stacks. The breasts currently
serve no gas, oil or solid fuel appliances, so are effectively redundant.
The purpose of chimney breasts is to house flues which allow the products of combustion to safely
discharge to the atmosphere via the chimney stack. Over time, flues can deteriorate allowing
combustion gases to leak into the living accommodation, thereby creating a serious health hazard.
Not only must flues be maintained in good condition, but they must also be the correct size and
design to serve any installed appliance or solid fuel fire or appliance.
It is not possible to assess the condition of flues or the presence or type of flue liners by visual
inspection. Before any appliance or coal fire is installed, the relevant flue must be tested to ensure
it is in sound condition and that it meets current safety regulations. This must be undertaken by a
suitably legally qualified person, who should also confirm that adequate ventilation has been
provided to all appliances. All tests must be undertaken before any appliances are used. Existing
flues may require significant upgrading, possibly including re-lining or replacement, which is costly.
Flues should be terminated externally with appropriate terminations or cowls.
The plaster finish to the rear chimney breast is very uneven and it appears a vent has been
wallpapered over. Re-plastering and decoration is required.
Photo - 54 Photo - 55
A range of fitted units to the kitchen were noted, comprising work surfaces and sink / drainer with
cupboards and drawers at high and low level.
Kitchen fittings are generally in serviceable condition and other than general ageing and some
blemishes no significant defects were noted.
Built-in fittings can conceal a variety of problems that are only revealed when they are removed for
repair. For example, kitchen units often hide water and gas pipes, or obscure dampness to walls.
2
E6 Built-in fittings (built-in kitchen and other fittings, not including appliances)
Page 38RICS Home Survey - Level 3
You should plan for a higher level of maintenance with these older fittings.
Flexible sealants around sinks and worktops should be regularly checked and maintained. Damage
may allow water penetration to enclosed areas beneath, which can cause rot and decay.
There is insufficient ventilation in the kitchen and additional ventilation should now be installed to
prevent condensation and related defects.
Other fixtures and fittings are generally in serviceable condition. Again, It is assumed you have
already assessed the adequacy of these, for your own purposes.
It is common in properties of this age to discover asbestos containing materials, particularly in the
form of panels and linings in enclosures such as airing cupboards. When painted over, or
concealed by finishes or household items, it is not possible at the time of survey to categorically
state the property is free of asbestos. When repairs or improvements are undertaken internally,
asbestos materials may be discovered and this will result in unforeseen costs as specialist testing /
treatment or removal may be required.
Photo - 56
Internal joinery comprises the staircase, skirtings, internal doors, door frames/ linings, architraves
and window sills.
Period doors generally require more maintenance compared to modern internal doors. Locks and
handles can be difficult to obtain as well as being relatively costly. This should be budgeted for
accordingly.
Internal joinery is in poor condition and general repairs, refurbishment and decoration is required.
Internal doors would benefit from minor easing and adjusting and an overhaul of locks, in addition
to various repairs.
Architraves and skirtings are generally susceptible to impact damage and ongoing maintenance
and decoration is required.
Some internal doors to the ground floor have been removed and they should be reinstated as
internal doors improve fire safety, especially to kitchens.
2
E7 Woodwork (for example, staircase joinery)
Page 39RICS Home Survey - Level 3
The internal decorations are generally in a dated condition, soiled in areas, and redecoration is
recommended. You should allow for some making good as part of the preparation works.
Photo - 57 Photo - 58
The property is served by a main bathroom on the ground floor.
Sanitary appliances are not in new condition and not free of blemishes and general ageing. They
do appear to be functional however.
Seals to sanitary fittings such as baths and shower cubicles are often neglected and will gradually
perish over time, resulting in moisture penetration to walls and floors. When bath panels or shower
trays are removed, the concealed timbers may be affected by moisture in which case local repairs
may be required. Accordingly, seals should be kept in good condition at all times, particularly to
bath and shower tray edges.
2
Photo - 59 Photo - 60
There are no other matters requiring comment.
E8 Bathroom fittings
E9 Other
Page 40RICS Home Survey - Level 3
FServices
Services are generally hidden within the construction of the property. This means that we
can only inspect the visible parts of the available services, and we do not carry out
specialist tests. The visual inspection cannot assess the services to make sure they work
efficiently and safely, and meet modern standards.
Page 41RICS Home Survey - Level 3
NI321
Safety warning: You should have your electrical installations inspected and tested regularly to
protect your home from damage and to avoid putting your safety at risk. Guidance published by the
Institution of Electrical Engineers recommends that electrical installations should be inspected and
tested at least every 10 years and when the occupiers of the property change. All electrical work
carried out after 1 January 2005 should be recorded on an Electrical Installation Certificate.
Mains electricity is connected to the property. The rising main and meter is located in the front
reception room and the contractual arrangements for the supply should be confirmed by your Legal
Adviser. The consumer unit is located in the same area.
In view of the guidance given above relating to change of occupancy, it is essential the installation
is now checked by an appropriate specialist registered with either the NICEIC or similar approved
body prior to exchange of contracts.
Lighting and power provision may be inadequate for your needs and due allowance should be
made for upgrading the electrical installation accordingly.
3
Services
Limitations on the inspection
Services are generally hidden within the construction of the property and, as a result, only the visible parts
of the available services can be inspected. The Surveyor does not carry out specialist tests. The visual
inspection does not assess the services to make sure they work properly and efficiently and meet modern
standards.
In addition to confirmation of past service records and warranties, we strongly advise that you commission
your own independent safety inspection reports for the various service installations via suitably qualified
engineers prior to purchase together with associated costings for necessary upgrading/repair works.
F1 Electricity
Safety warning: The Electrical Safety Council recommends that you should get a registered electrician to check the property and its
electrical fittings at least every ten years, or on change of occupancy. All electrical installation work undertaken after 1 January 2005
should have appropriate certification. For more advice, contact the Electrical Safety Council.
F
Page 42RICS Home Survey - Level 3
Photo - 61 Photo - 62
Safety warning: All gas appliances and equipment should regularly be inspected, tested,
maintained and serviced by a registered ‘competent person’ and in line with the manufacturer’s
instructions.
Only general observations will be made on the system. You must seek independent qualified
advice that is based upon specific testing of the installation. This is to be carried out prior to legal
commitment to purchase the property.
This is important to make sure that the equipment is working correctly, to limit the risk of fire and
carbon monoxide poisoning, and to prevent carbon dioxide and other greenhouse gases from
leaking into the air. For more advice, contact the Gas Safe Register for gas installations.
Mains gas is connected to the property and the rising main and meter is located in the front
reception room. The contractual arrangements for the gas supply should be confirmed by your
Legal Adviser.
As a matter of safety, you should now arrange for the installation and all gas appliances to be
inspected and tested by a suitably qualified engineer prior to exchange of contracts.
3
F2 Gas/oil
Safety warning: All gas and oil appliances and equipment should be regularly inspected, tested, maintained and serviced by a
registered ‘competent person’ in line with the manufacturer’s instructions. This is important to make sure that the equipment is working
correctly, to limit the risk of fire and carbon monoxide poisoning, and to prevent carbon dioxide and other greenhouse gases from
leaking into the air. For more advice, contact the Gas Safe Register for gas installations, and OFTEC for oil installations.
Page 43RICS Home Survey - Level 3
Photo - 63
The property is served by a mains water supply.
Whilst every effort is made to identify any obvious deficiencies or signs of problematic areas, our
inspection is a visual, surface level only and no tests are carried out. Much of the plumbing
installation is often hidden away within sub-structures such as floors, walls and ceilings etc. A
further, more detailed, review and test of the plumbing installation is advised so, as to avoid any
problems after taking up occupation.
The external stop valve could not be located and confirmed and you should make enquiries of the
relevant water company to ascertain its location.
The internal stop valve could not be located and confirmed and you should make enquiries via your
Legal Adviser to ascertain its location. It is important you locate and test the effectiveness of the
stop valve upon occupation as a defective or inaccessible stop tap can result in considerable
damage being caused by a water leak. It cannot be ascertained if the property has a water meter
and your Legal Adviser should make enquiries in this respect.
There are defects to the plumbing, including poorly installed and aged pipework.
A reputable plumber should be engaged to inspect the installation and provide a quotation for all
necessary repairs and improvements.
2
F3 Water
Page 44RICS Home Survey - Level 3
Photo - 64
Safety Warning: Your attention is drawn to the advice above regarding the need to ensure all gas
appliances and flues are tested and serviced annually, by a competent person.
Space heating within the property is provided by the gas central heating system.
The central heating system is energised by a wall mounted gas fired boiler located in the kitchen.
This serves steel panelled radiators noted around the property. The gas boiler is in a complete
state of disrepair and has to be assumed to be in a dangerous condition and in need of urgent
removal and replacement. Some radiators are damaged and badly marked.
A Registered Gas Safe Engineer should be instructed to inspect the system immediately and
disconnect the gas boiler from the gas supply. A report should also be obtained detailing the
condition of all central heating components with an estimated repair, replacement and upgrading
cost.
3
Photo - 65 Photo - 66
F4 Heating
Page 45RICS Home Survey - Level 3
Hot water is provided by the main gas boiler. Arrangements should be made for the system to be
checked and tested prior to exchange of contracts.3
The property is believed to be connected to the mains drainage system.
We will lift drain covers where possible and make an observation on the system. This will not
include a formal CCTV scan or drainage test. If you wish to know more or have concerns you
should obtain a specialist drainage report.
The main Soil and Vent pipe (SVP) is concealed within the fabric of the building.
Waste pipes, where visible, appear to be in generally serviceable condition with no evidence of
significant defects although some ongoing maintenance will be required.
An external gully was noted to be free from damage but obstructed and in need of clearing out.
The gully should be checked regularly and cleared out as necessary.
It was not possible to lift a seized inspection chamber cover because excessive force would have
been needed and this would have rendered the cover susceptible to damage. The Inspection
Chamber cover should be released as soon as possible to allow inspection and access to the
underground drainage system.
The system has to be expressly excluded from the scope of this report therefore.
There was no evidence above ground to suggest a drainage problem exists, however.
Given the general age of the property and given our relatively limited inspection of the below-
ground drainage system you may deem it prudent, to undertake a CCTV examination of the
drainage system as a precautionary measure to ensure serviceability.
NI
Photo - 67 Photo - 68
There are believed to be no common services.
F5 Water heating
F6 Drainage
F7 Common services
Page 46RICS Home Survey - Level 3
GGrounds
(including shared areas for flats)
Page 47RICS Home Survey - Level 3
NI321
There is no garage to the property.
The property has no permanent outbuildings or other structures.
The property has a small area to the front and a small garden to the rear. There are no formal
fences to the rear other than informal barriers.
Uneven pavers can be a trip hazard and impede drainage. Replacing uneven pavers and re-
bedding and levelling uneven pavers is advised. It is suspected that surface water to the rear area
is not draining effectively and improvements may be required in this respect.
Concrete hard-standing areas frequently crack and become uneven, as was noted here. Cracks
should be repaired and hard-standing areas should be brought back to a smooth surface.
There a lot of waste items in the garden and the removal of these items should be budgeted for.
Both this garden and neighbouring gardens are very neglected and generally full of waste items.
The presence of vermin is inevitable and this will require specialist eradication.
It is not possible to categorically confirm the property is free from invasive plant species such as
Japanese Knotweed. This is especially important because this garden and neighbouring gardens
are neglected and full of many different weeds and plants. It is beyond the scope of this report to
identify all of these plants. You are advised to procure a specialist survey if you require assurance
the property is free from such invasive plants.
Repairs and improvements should be budgeted for accordingly.
2
Grounds (including shared areas for flats)
Limitations on the inspection
The gardens and grounds are inspected generally. We will make general observations about the gardens
and boundaries. These are not inspected to the same level as the residence itself.
The position, rights and responsibility of the various boundaries around the property should be verified with
your legal adviser, as some maintenance and general upgrading may be expected in due course.
Any noted outbuildings are inspected to assess general condition only. They are not inspected to the
same level as the residence. A general overall impression is provided together with any additional matters
the surveyor feels to be of noteworthy comment.
G1 Garage
G2 Permanent outbuildings and other structures
G3 Other
G
Page 48RICS Home Survey - Level 3
It appears there is a path across the rear garden which allows neighbours to access their gardens.
Details and implications should be confirmed by your Legal Adviser.
Photo - 69 Photo - 70
Photo - 71 Photo - 72
Photo - 73
Page 49RICS Home Survey - Level 3
HIssues for your legal advisers
We do not act as a legal adviser and will not comment on any legal documents. However,
if, during the inspection, we identify issues that your legal advisers may need to investigate
further, we may refer to these in the report (for example, to state you should check
whether there is a warranty covering replacement windows). You should show your legal
advisers this section of the report.
Page 50RICS Home Survey - Level 3
Issues for your legal advisers
H1 Regulation
The property has been extended/altered in the form of;
- Extension to the rear (Building Regulation & Planning Permission)
- Replacement roof covering and structure (Building Regulation)
- Alterations to Electrical Installation (Building Regulation)
Your legal adviser must confirm that all necessary statutory consents and regulations (as stated above)
were obtained and complied with, prior to legal commitment to purchase. In the absence of such, in the
first instance, you should refer back to us for further advice as to how best to proceed. If the above is not
confirmed prior to purchase, and you decide to proceed, you must accept the risk of defects occurring at a
later date, which were not visible or apparent at the time of our inspection.
H2 Guarantees
Your legal advisor should confirm whether there is a transferable, and enforceable warranty scheme in
place for:
Remedial damp treatment works
Replacement windows/doors
Chemical damp-proof course
H3 Other matters
The position of the boundaries of the land around a property are important because doubt over their
location can give rise to disputes that can be time consuming and expensive to resolve.
Your Legal Adviser should confirm the legal boundaries to the property correspond with delineating
physical features such as walls, fences and hedges, etc.
There appears to be a footpath across the rear garden which enables neighbours to access their back
gardens and your Legal Adviser should confirm the arrangements and implications.
Access rights and arrangements to the rear garden, i.e. a shared and gated path should be confirmed.
H
Page 51RICS Home Survey - Level 3
Photo - 74
Page 52RICS Home Survey - Level 3
IRisks
This section summarises defects and issues that present a risk to the building or grounds,
or a safety risk to people. These may have been reported and condition-rated against
more than one part of the property, or may be of a more general nature. They may have
existed for some time and cannot be reasonably changed.
Page 53RICS Home Survey - Level 3
Risks
I1 Risks to the building
The presence of damp has been identified and remedial measures are required.
It is recommended that you arrange for any builders or other specialist reports, estimates or tests before
you legally commit to purchasing the property so that you are fully aware of the costs.
I2 Risks to the grounds
The neglected condition of the grounds means there is a potentially significant risk of invasive species
such as Japanese Knotweed present.
I3 Risks to people
Without recent testing and up-to-date certificates for gas and electric services and appliances, these do
represent a potential health risk.
I4 Other risks or hazards
No other risks or hazards have been identified.
I
Page 54RICS Home Survey - Level 3
JEnergy matters
This section describes energy-related matters for the property as a whole. It takes into
account a broad range of energy-related features and issues already identified in the
previous sections of this report, and discusses how they may be affected by the condition
of the property.
This is not a formal energy assessment of the building, but part of the report that will help
you get a broader view of this topic. Although this may use information obtained from an
available EPC, it does not check the certificate’s validity or accuracy.
Page 55RICS Home Survey - Level 3
Energy matters
J1 Insulation
This property will not be as thermally efficient when compared to new buildings. As a result running costs
will be higher.
Further regard should be had to the matters raised within the energy performance certificate.
J2 Heating
The installation should be checked and tested every 12 months by a Gas Safe registered engineer in
order to ensure that it is in a safe and satisfactory working order.
When the boiler is due for replacement, consideration should be given to a high efficiency replacement.
J3 Lighting
Low energy lighting should be considered for all fixed outlets in an attempt to keep energy consumption
and running costs for the property as low as possible.
J4 Ventilation
Ventilation systems within the property are very important for the health of occupants and maintenance of
the property.
Mechanical ventilation extractions systems within the kitchen and sanitary areas should be reviewed and
upgraded as necessary. Natural background room ventilation should be introduced where possible in
order to keep moisture build up to a minimum.
Any redundant flues should be properly capped and vented.
J5 General
No other matters noted.
J
Page 56RICS Home Survey - Level 3
KSurveyor’s declaration
Page 57RICS Home Survey - Level 3
Surveyor’s RICS number Qualifications
0849864 MA MRICS
Email Website
[email protected] https://www.shapesurveyors.co.uk
Client's name Date the report was produced
Sukhwinder Rana 17th October 2021
Surveyor’s declaration
Company
Shape Property Surveyors Ltd
Address
Spaces Crossway, 156 Great Charles Street, Birmingham, West Midlands, B3 3HN
Phone number
03337729516 / 0121 769 2175
Property address
4 Uplands Rd
Handsworth
Birmingham
|B21 8BP
I confirm that I have inspected the property and prepared this report.
Signature
K
Page 58RICS Home Survey - Level 3
LWhat to do now
Page 59RICS Home Survey - Level 3
Further investigations and getting quotes
We have provided advice below on what to do next, now that you have an overview of any work to be carried
out on the property. We recommend you make a note of any quotations you receive. This will allow you to
check the amounts are in line with our estimates, if cost estimates have been provided.
Getting quotations
The cost of repairs may influence the amount you are prepared to pay for the property. Before you make a
legal commitment to buy the property, you should get reports and quotations for all the repairs and further
investigations the surveyor may have identified. You should get at least two quotations from experienced
contractors who are properly insured.
You should also:
• ask them for references from people they have worked for
• describe in writing exactly what you will want them to do and
• get the contractors to put their quotations in writing.
Some repairs will need contractors who have specialist skills and who are members of regulated
organisations (for example, electricians, gas engineers, plumbers and so on). You may also need to get
Building Regulations permission or planning permission from your local authority for some work.
Further investigations and what they involve
If we are concerned about the condition of a hidden part of the building, could only see part of a defect or do
not have the specialist knowledge to assess part of the property fully, we may have recommended that
further investigations should be carried out to discover the true extent of the problem.
This will depend on the type of problem, but to do this properly, parts of the home may have to be disturbed,
so you should discuss this matter with the current owner. In some cases, the cost of investigation may be
high.
When a further investigation is recommended, the following will be included in your report:
• a description of the affected element and why a further investigation is required
• when a further investigation should be carried out and
• a broad indication of who should carry out the further investigation.
Who you should use for further investigations
You should ask an appropriately qualified person, although it is not possible to tell you which one. Specialists
belonging to different types of organisations will be able to do this. For example, qualified electricians can
belong to five different government-approved schemes. If you want further advice, please contact the
surveyor.
L
Page 60RICS Home Survey - Level 3
MDescription of the RICS Home Survey
– Level 3 service and terms of
engagement
Page 61RICS Home Survey - Level 3
Description of the RICS Home Survey – Level 3
service and terms of engagement
The service
The RICS Home Survey – Level 3 service includes:
• a thorough inspection of the property (see 'The inspection' below) and
• a detailed report based on the inspection (see 'The report' below).
The surveyor who provides the RICS Home Survey – Level 3 service aims to give you professional advice to
help you to:
• help you make a reasoned and informed decision when purchasing the property, or when planning
for repairs, maintenance or upgrading the property
• provide detailed advice on condition
• describe the identifiable risk of potential or hidden defects
• propose the most probable cause(s) of the defects based on the inspection and
• where practicable and agreed, provide an estimate of costs and likely timescale for identified
repairs and necessary work.
Any extra services provided that are not covered by the terms and conditions of this service must be covered
by a separate contract.
The inspection
The surveyor carefully and thoroughly inspects the inside and outside of the main building and all permanent
outbuildings, recording the construction and defects that are evident. This inspection is intended to cover as
much of the property as is physically accessible. Where this is not possible, an explanation is provided in the
‘Limitations on the inspection’ box in the relevant section of the report.
The surveyor does not force or open up the fabric of the building without occupier/owner consent, or if there
is a risk of causing personal injury or damage. This includes taking up fitted carpets and fitted floor coverings
or floorboards; moving heavy furniture; removing the contents of cupboards, roof spaces, etc.; removing
secured panels and/or hatches; or undoing electrical fittings.
If necessary, the surveyor carries out parts of the inspection when standing at ground level from adjoining
public property where accessible. This means the extent of the inspection will depend on a range of
individual circumstances at the time of inspection, and the surveyor judges each case on an individual basis.
The surveyor uses equipment such as a damp meter, binoculars and torch, and uses a ladder for flat roofs
and for hatches no more than 3m above level ground (outside) or floor surfaces (inside) if it is safe to do so.
If it is safe and reasonable to do so, the surveyor will enter the roof space and visually inspect the roof
structure with attention paid to those parts vulnerable to deterioration and damage. Although thermal
insulation is not moved, small corners should be lifted so its thickness and type, and the nature of underlying
ceiling can be identified (if the surveyor considers it safe to do). The surveyor does not move stored goods or
other contents.
The surveyor also carries out a desk-top study and makes oral enquiries for information about matters
affecting the property.
M
Page 62RICS Home Survey - Level 3
Services to the property
Services are generally hidden within the construction of the property. This means that only the visible parts
of the available services can be inspected, and the surveyor does not carry out specialist tests other than
through their normal operation in everyday use. The visual inspection cannot assess the efficiency or safety
of electrical, gas or other energy sources. It also does not investigate the plumbing, heating or drainage
installations (or whether they meet current regulations), or the internal condition of any chimney, boiler or
other flue.
Outside the property
The surveyor inspects the condition of boundary walls, fences, permanent outbuildings and areas in common
(shared) use. To inspect these areas, the surveyor walks around the grounds and any neighbouring public
property where access can be obtained. Where there are restrictions to access (e.g. a creeper plant
prevents closer inspection), these are reported and advice is given on any potential underlying risks that may
require further investigation.
Buildings with swimming pools and sports facilities are also treated as permanent outbuildings and are
therefore inspected, but the surveyor does not report on the leisure facilities, such as the pool itself and its
equipment internally or externally, landscaping and other facilities (for example, tennis courts and temporary
outbuildings).
Flats
When inspecting flats, the surveyor assesses the general condition of the outside surfaces of the building, as
well as its access and communal areas (for example, shared hallways and staircases that lead directly to the
subject flat) and roof spaces, but only if they are accessible from within or owned by the subject flat or
communal areas. The surveyor also inspects (within the identifiable boundary of the subject flat) drains, lifts,
fire alarms and security systems, although the surveyor does not carry out any specialist tests other than
their normal operation in everyday use.
External wall systems are not inspected. If the surveyor has specific concerns about these items, further
investigation will be recommended prior to legal commitment to purchase.
Dangerous materials, contamination and environmental issues
The surveyor makes enquiries about contamination or other environmental dangers. If the surveyor suspects
a problem, they recommend a further investigation.
The surveyor may assume that no harmful or dangerous materials have been used in the construction, and
does not have a duty to justify making this assumption. However, if the inspection shows that such materials
have been used, the surveyor must report this and ask for further instructions.
The surveyor does not carry out an asbestos inspection and does not act as an asbestos inspector when
inspecting properties that may fall within The Control of Asbestos Regulations 2012 (‘CAR 2012’). However,
the report should properly emphasise the suspected presence of asbestos containing materials if the
inspection identifies that possibility. With flats, the surveyor assumes that there is a ‘dutyholder’ (as defined
in the regulations), and that there is an asbestos register and an effective management plan in place, which
does not present a significant risk to health or need any immediate payment. The surveyor does not consult
the dutyholder.
Page 63RICS Home Survey - Level 3
The report
The surveyor produces a report of the inspection results for you to use, but cannot accept any liability if it is
used by anyone else. If you decide not to act on the advice in the report, you do this at your own risk. The
report is aimed at providing you with a detailed understanding of the condition of the property to allow you to
make an informed decision on serious or urgent repairs, and on the maintenance of a wide range of reported
issues.
Condition ratings
The surveyor gives condition ratings to the main parts (the ‘elements’) of the main building, garage and some
outside elements. The condition ratings are described as follows:
• R – Documents we may suggest you request before you sign contracts.
• Condition rating 3– Defects that are serious and/or need to be repaired, replaced or investigated
urgently. Failure to do so could risk serious safety issues or severe long-term damage to your
property. Written quotations for repairs should be obtained prior to legal commitment to purchase.
• Condition rating 2 – Defects that need repairing or replacing but are not considered to be either
serious or urgent. The property must be maintained in the normal way.
• Condition rating 1 – No repair is currently needed. The property must be maintained in the normal
way.
• NI – Elements not inspected.
The surveyor notes in the report if it was not possible to check any parts of the property that the inspection
would normally cover. If the surveyor is concerned about these parts, the report tells you about any further
investigations that are needed.
Energy
The surveyor has not prepared the Energy Performance Certificate (EPC) as part of the RICS Home Survey
– Level 3 service for the property. Where the EPC has not been made available by others, the surveyor will
obtain the most recent certificate from the appropriate central registry where practicable. If the surveyor has
seen the current EPC, they will present the energy efficiency rating in this report. Where possible and
appropriate, the surveyor will include additional commentary on energy-related matters for the property as a
whole in the energy efficiency section of the report, but this is not a formal energy assessment of the
building. Checks will be made for any obvious discrepancies between the EPC and the subject property, and
the implications will be explained to you. As part of the Home Survey – Level 3 Service, the surveyor will
advise on the appropriateness of any energy improvements recommended by the EPC.
Page 64RICS Home Survey - Level 3
Issues for legal advisers
The surveyor does not act as a legal adviser and does not comment on any legal documents. If, during the
inspection, the surveyor identifies issues that your legal advisers may need to investigate further, the
surveyor may refer to these in the report (for example, to state you should check whether there is a warranty
covering replacement windows).
This report has been prepared by a surveyor merely in their capacity as an employee or agent of a firm,
company or other business entity (‘the Company’). The report is the product of the Company, not of the
individual surveyor. All of the statements and opinions contained in this report are expressed entirely on
behalf of the Company, which accepts sole responsibility for them. For their part, the individual surveyor
assumes no personal financial responsibility or liability in respect of the report, and no reliance or inference
to the contrary should be drawn.
In the case of sole practitioners, the surveyor may sign the report in their own name, unless the surveyor
operates as a sole trader limited liability company.
Nothing in this report excludes or limits liability for death or personal injury (including disease and impairment
of mental condition) resulting from negligence.
Risks
This section summarises defects and issues that present a risk to the building or grounds, or a safety risk to
people. These may have been reported and condition rated against more than one part of the property, or
may be of a more general nature. They may have existed for some time and cannot be reasonably changed.
The RICS Home Survey – Level 3 report will identify risks, explain the nature of the problems and explain
how the client may resolve or reduce the risk.
If the property is leasehold, the surveyor gives you general advice and details of questions you should ask
your legal advisers.
Page 65RICS Home Survey - Level 3
Standard terms of engagement
1 The service – The surveyor provides the standard RICS Home Survey – Level 3 service described in this
section, unless you agree with the surveyor in writing before the inspection that the surveyor will provide
extra services. Any extra service will require separate terms of engagement to be entered into with the
surveyor. Examples of extra services include:
• schedules of works
• supervision of works
• re-inspection
• detailed specific issue reports
• market valuation and re-instatement cost, and
• negotiation.
2 The surveyor – The service will be provided by an AssocRICS, MRICS or FRICS member of the Royal
Institution of Chartered Surveyors (RICS) who has the skills, knowledge and experience to survey and report
on the property.
3 Before the inspection – Before the inspection, you should tell us if there is already an agreed or proposed
price for the property, and if you have any particular concerns about the property (such as a crack noted
above the bathroom window or any plans for extension).
This period forms an important part of the relationship between you and the surveyor. The surveyor will use
reasonable endeavours to contact you to discuss your particular concerns regarding the property, and
explain (where necessary) the extent and/or limitations of the inspection and report. The surveyor also
carries out a desktop study to understand the property better.
4 Terms of payment – You agree to pay the surveyor’s fee and any other charges agreed in writing.
5 Cancelling this contract – You should seek advice on your obligations under The Consumer Contracts
(Information, Cancellation and Additional Charges) Regulations 2013 (‘the Regulations’) and/or the
Consumer Rights Act 2015, in accordance with section 2.6 of the current edition of the Home survey
standard RICS professional statement.
6 Liability – The report is provided for your use, and the surveyor cannot accept responsibility if it is used, or
relied upon, by anyone else.
Note: These terms form part of the contract between you and the surveyor.
This report is for use in the UK.
Complaints handling procedure
The surveyor will have a complaints handling procedure and will give you a copy if you ask. The surveyor is
required to provide you with contact details, in writing, for their complaints department or the person
responsible for dealing with client complaints. Where the surveyor is party to a redress scheme, those details
should also be provided. If any of this information is not provided, please notify the surveyor and ask for it to
be supplied.
Page 66RICS Home Survey - Level 3
NTypical house diagram
Page 67RICS Home Survey - Level 3
Typical house diagram
This diagram illustrates where you may find some of the building elements referred to in the report.
N
Page 68RICS Home Survey - Level 3
! You should know...
RICS disclaimer
This report has been prepared by a surveyor merely in their capacity as an employee or agent of a
firm, company or other business entity (‘the Company’). The report is the product of the Company, not
of the individual surveyor. All of the statements and opinions contained in this report are expressed
entirely on behalf of the Company, which accepts sole responsibility for them. For their part, the
individual surveyor assumes no personal financial responsibility or liability in respect of the report, and
no reliance or inference to the contrary should be drawn.
In the case of sole practitioners, the surveyor may sign the report in their own name unless the
surveyor operates as a sole trader limited liability company.
Nothing in this report excludes or limits liability for death or personal injury (including disease and
impairment of mental condition) resulting from negligence.
This document is issued in blank form by the Royal Institution of Chartered Surveyors (RICS) and is
available only to parties who have signed a licence agreement with RICS.
RICS gives no representations or warranties, express or implied, and no responsibility or liability is
accepted for the accuracy or completeness of the information inserted into the document, or any other
written or oral information given to any interested party or its advisers. Any such liability is expressly
disclaimed.
Page 69RICS Home Survey - Level 3