TC Fluid Control are world revered for the design, manufacture and sales of liquid level instrumentation products.
The company was established in 2003 having been part of the UK business of Trouvay & Cauvin based in Le Havre France.
The instrumentation Division was originally founded in the UK as Richard Klinger Ltd in 1933. In December 1999 Trouvay & Cauvin Ltd acquired the Instrumentation Division which was based in Sidcup and in 2002 the UK Management Team bought out the UK side of the company.
In 2003 the Company was renamed to TC Fluid Control to give focus for it to develop in the liquid level instrumentation field. Ten years later, in 2013, TC Fluid Control became part of WIKA Instruments Limited.
With a wealth of knowledge, derived from decades of focus in Level Controls, our sales application engineers provide expert advice on the correct choice of level instrument for any given application. Our products are renowned for their precision, quality and reliability and are used by process plant operators throughout the world.
In addition to high quality product supply we are also highly experienced in contractor projects and offer full documentary facilities for the demands of project management.
2www.tc-fluidcontrol.com
Introduction
Transmit Submersible pressure sensors
Transmit Continuous measurement with float
Level measuring instruments for liquid - overview
Switch Float switches
Switch Optoelectronic switches
4
5-7
8-9
10-13
14-15
3www.tc-fluidcontrol.com
Contents
Applications � Level measurement in rivers and lakes � Control of sewage lift and pumping stations � Monitoring of sewage, settling and rainwater retention basins � Level measurement in vessel and storage systems for oils and
fuels
Special features � Slimline and hermetically sealed design up to 300 m water
column � Highly resistant versions available � Explosion protection per ATEX, IECEx, FM and CSA � Drinking water conformity per KTW and ACS � Temperature output, HART® and low-power output signal for
battery operation
LF-1For superior applications
Accuracy (± % of span) ≤ 0.5 or ≤ 1Measuring range 0 … 0.1 to 0 … 6 barOutput signal ■ 4 ... 20 mA (2-wire)
■ 4 … 20 mA + HART® (2-wire) ■ DC 0.1 … 2.5 V (3-wire)
Special feature ■ Suitable for measurements in contaminated and aggressive media
■ An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a minimum maintenance effort
■ Can be used in explosion-protected areas
■ Developed for wireless applications
Data sheet LM 40.04
LS-10Standard version
Accuracy (± % of span) ≤ 0.5Measuring range 0 … 0.25 to 0 … 10 barOutput signal 4 ... 20 mA (2-wire)Data sheet PE 81.55
LH-20High-performance
Accuracy (± % of span) ≤ 0.2 or 0.1Measuring range ■ 0 … 0.1 to 0 … 25 bar
■ 0 … 1.6 to 0 … 25 bar abs.Special feature ■ Scalable measuring range (optional)
■ Resistant against the harshest environ-mental conditions
■ Reliable and secure by double-sealed design
■ Titanium case for especially high resist-ance (optional)
Data sheet PE 81.56
Submersible pressure sensorsHydrostatic level measurement
www.tc-fluidcontrol.com4
Applications � Level measurement in rivers and lakes � Control of sewage lift and pumping stations � Monitoring of sewage, settling and rainwater retention basins � Level measurement in vessel and storage systems for oils and
fuels
Special features � Slimline and hermetically sealed design up to 300 m water
column � Highly resistant versions available � Explosion protection per ATEX, IECEx, FM and CSA � Drinking water conformity per KTW and ACS � Temperature output, HART® and low-power output signal for
battery operation
LF-1For superior applications
Accuracy (± % of span) ≤ 0.5 or ≤ 1Measuring range 0 … 0.1 to 0 … 6 barOutput signal ■ 4 ... 20 mA (2-wire)
■ 4 … 20 mA + HART® (2-wire) ■ DC 0.1 … 2.5 V (3-wire)
Special feature ■ Suitable for measurements in contaminated and aggressive media
■ An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a minimum maintenance effort
■ Can be used in explosion-protected areas
■ Developed for wireless applications
Data sheet LM 40.04
LS-10Standard version
Accuracy (± % of span) ≤ 0.5Measuring range 0 … 0.25 to 0 … 10 barOutput signal 4 ... 20 mA (2-wire)Data sheet PE 81.55
LH-20High-performance
Accuracy (± % of span) ≤ 0.2 or 0.1Measuring range ■ 0 … 0.1 to 0 … 25 bar
■ 0 … 1.6 to 0 … 25 bar abs.Special feature ■ Scalable measuring range (optional)
■ Resistant against the harshest environ-mental conditions
■ Reliable and secure by double-sealed design
■ Titanium case for especially high resist-ance (optional)
Data sheet PE 81.56
RLT-1000Stainless steel version
Accuracy 24, 12, 10, 6 or 3 mmOutput signal Resistance signal
or 4 … 20 mATemperature -30 … +80 °C
(+120 °C optional)Guide tube length 150 … 1,500 mmData sheet LM 50.02
RLT-2000Plastic version
Accuracy 24, 12, 10, 6 or 3 mmOutput signal Resistance signal
or 4 … 20 mATemperature -10 … +80 °C
(-30 … +120 °C optional)Guide tube length 150 … 1,500 mmData sheet LM 50.01
RLT-3000Stainless steel version with temperature output signal
Accuracy 24, 12, 10, 6 or 3 mmLevel output signal
4 … 20 mAOutput signalTemperature
4 … 20 mA, Pt100 or Pt1000
Temperature -30 … +100 °CGuide tube length 150 … 1,500 mmData sheet LM 50.05
Applications � Level measurement of liquids in machine building � Control and monitoring tasks for hydraulic power packs,
compressors and cooling systems
Special features � Media compatibility: Oil, water, diesel, refrigerants and other
liquids � Permissible medium temperature: -30 … +120 °C � Output signals for level and temperature (optional) as
resistance output signal or 4 ... 20 mA current output � Measurement principle: Reed-chain technology � Accuracy, resolution: 24, 12, 10, 6 or 3 mm
Level | Transmit
www.tc-fluidcontrol.com5
Continuous measurement with float for industrial applicationsWith reed measuring chain
RLT-1000Stainless steel version
Accuracy 24, 12, 10, 6 or 3 mmOutput signal Resistance signal
or 4 … 20 mATemperature -30 … +80 °C
(+120 °C optional)Guide tube length 150 … 1,500 mmData sheet LM 50.02
RLT-2000Plastic version
Accuracy 24, 12, 10, 6 or 3 mmOutput signal Resistance signal
or 4 … 20 mATemperature -10 … +80 °C
(-30 … +120 °C optional)Guide tube length 150 … 1,500 mmData sheet LM 50.01
RLT-3000Stainless steel version with temperature output signal
Accuracy 24, 12, 10, 6 or 3 mmLevel output signal
4 … 20 mAOutput signalTemperature
4 … 20 mA, Pt100 or Pt1000
Temperature -30 … +100 °CGuide tube length 150 … 1,500 mmData sheet LM 50.05
Applications � Level measurement of liquids in machine building � Control and monitoring tasks for hydraulic power packs,
compressors and cooling systems
Special features � Media compatibility: Oil, water, diesel, refrigerants and other
liquids � Permissible medium temperature: -30 … +120 °C � Output signals for level and temperature (optional) as
resistance output signal or 4 ... 20 mA current output � Measurement principle: Reed-chain technology � Accuracy, resolution: 24, 12, 10, 6 or 3 mm
FLM-SStainless steel version
Process connection ■ Mounting thread ■ Flange: DIN, ANSI
Guide tube length Max. 6,000 mmPressure 0 … 200 barTemperature -90 … +450 °CDensity ≥ 400 kg/m³Data sheet LM 20.01
FLM-SPPlastic version
Process connection ■ Mounting thread■ Flange DIN, ANSI
Guide tube length Max. 5,000 mmPressure 0 … 16 barTemperature -10 … +100 °CDensity ≥ 800 kg/m³Data sheet LM 20.01
FLM-HHygienic version, for sanitary applications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.01
Applications � High-accuracy level measurement for almost all liquid media � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry, pharmaceutical industry
Special features � Process- and system-specific solutions possible � Operating limits: □ Operating temperature: T = -90 … +400 °C
□ Operating pressure: P = vacuum to 100 bar□ Limit density: ρ ≥ 400 kg/m3
� Resolution < 0.1 mm � Wide variety of different electrical connections, process
connections and materials � Explosion-protected versions
VARIVENT® is a registered trademark of the company GEA TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
Continuous measurement with float for the process industry Magnetostrictive
www.tc-fluidcontrol.com6
FLM-SStainless steel version
Process connection ■ Mounting thread ■ Flange: DIN, ANSI
Guide tube length Max. 6,000 mmPressure 0 … 200 barTemperature -90 … +450 °CDensity ≥ 400 kg/m³Data sheet LM 20.01
FLM-SPPlastic version
Process connection ■ Mounting thread■ Flange DIN, ANSI
Guide tube length Max. 5,000 mmPressure 0 … 16 barTemperature -10 … +100 °CDensity ≥ 800 kg/m³Data sheet LM 20.01
FLM-HHygienic version, for sanitary applications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.01
Applications � High-accuracy level measurement for almost all liquid media � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry, pharmaceutical industry
Special features � Process- and system-specific solutions possible � Operating limits: □ Operating temperature: T = -90 … +400 °C
□ Operating pressure: P = vacuum to 100 bar□ Limit density: ρ ≥ 400 kg/m3
� Resolution < 0.1 mm � Wide variety of different electrical connections, process
connections and materials � Explosion-protected versions
VARIVENT® is a registered trademark of the company GEA TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
FLR-SA, FLR-SBStainless steel version
Process connection ■ Mounting thread■ Flange DIN,
ANSI, ENGuide tube length Max. 6,000 mmPressure 0 … 100 barTemperature -80 … +200 °CDensity ≥ 400 kg/m³Data sheet LM 20.02
FLR-PA, FLR-PBPlastic version, PP, PVDF, PP
Process connection ■ Mounting thread■ Flange DIN,
ANSI, ENGuide tube length Max. 5,000 mmPressure 0 … 3 barTemperature -10 … +100 °CDensity ≥ 800 kg/m3
Data sheet LM 20.02
FLR-HA3Hygienic version, for sanitary applications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.02
Applications � Level detection for almost all liquid media � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry, pharmaceutical industry
Special features � Process- and system-specific solutions possible � Operating limits: □ Operating temperature: T = -80 … +200 °C
□ Operating pressure: P = vacuum to 80 bar□ Limit density: ρ ≥ 400 kg/m3
� Wide variety of different electrical connections, processconnections and materials
� Optionally with programmable and configurable head-mountedtransmitter for 4 … 20 mA field signals, HART®, PROFIBUS®
PA and FOUNDATION™ Fieldbus � Explosion-protected versions
VARIVENT® is a registered trademark of the company GEA TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
www.tc-fluidcontrol.com7
With reed measuring chain
FLR-SA, FLR-SBStainless steel version
Process connection ■ Mounting thread■ Flange DIN,
ANSI, ENGuide tube length Max. 6,000 mmPressure 0 … 100 barTemperature -80 … +200 °CDensity ≥ 400 kg/m³Data sheet LM 20.02
FLR-PA, FLR-PBPlastic version, PP, PVDF, PP
Process connection ■ Mounting thread■ Flange DIN,
ANSI, ENGuide tube length Max. 5,000 mmPressure 0 … 3 barTemperature -10 … +100 °CDensity ≥ 800 kg/m3
Data sheet LM 20.02
FLR-HA3Hygienic version, for sanitary applications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.02
Applications � Level detection for almost all liquid media � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry, pharmaceutical industry
Special features � Process- and system-specific solutions possible � Operating limits: □ Operating temperature: T = -80 … +200 °C
□ Operating pressure: P = vacuum to 80 bar□ Limit density: ρ ≥ 400 kg/m3
� Wide variety of different electrical connections, processconnections and materials
� Optionally with programmable and configurable head-mountedtransmitter for 4 … 20 mA field signals, HART®, PROFIBUS®
PA and FOUNDATION™ Fieldbus � Explosion-protected versions
VARIVENT® is a registered trademark of the company GEA TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
Level | Transmit
WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 30∙63911 Klingenberg∙Germany
Tel. +49 9372 132-0∙Fax +49 9372 [email protected]∙www.wika.de
SLSSuspended fl oat switches
Data sheet: LM 32.01
Level measuring instrumentsfor water applications
14156384 02/2016 EN
FLM-SPLevel sensor,plastic version
Process connection: ■ Mounting thread■ Flange: DIN, ANSI, EN
Guide tube length: Max. 5,000 mmPressure: 0 … 16 barTemperature: -10 … +100 °CDensity: ≥ 800 kg/m³Data sheet: LM 20.01
FLM-SLevel sensor, Stainlesssteel Version
Process connection: ■ Mounting thread■ Flange: DIN, ANSI, EN
Guide tube length: Max. 6,000 mmPressure: 0 … 200 barTemperature: -90 … +450 °CDensity: ≥ 400 kg/m³Data sheet: LM 20.01
FLS-SMagnetic fl oat switch,stainless steel version
Switch points: Max. 8 switch pointsProcess connection: ■ Mounting thread
■ Flange: DIN, ANSI, ENGuide tube length: Max. 6,000 mmPressure: 0 … 100 barTemperature: -196 … +300 °CDensity: ≥ 390 kg/m³Data sheet: LM 30.01
FLS-PMagnetic fl oat switch,plastic version
Switch points: Max. 8 switch pointsProcess connection: ■ Mounting thread
■ Flange:DIN, ANSI, EN
Guide tube length: Max. 5,000 mmPressure: 0 … 3 barTemperature: -10 … +100 °CDensity: ≥ 400 kg/m³Data sheet: LM 30.01
DPT-10Diff erential pressure transmitter
Non-linearity(% of span): ≥ 0,075 ... 0,15Measuring range: 0 ... 10 mbar to 0 ... 40 barSpecial features: ■ Freely scaleable measuring ranges
■ Case from plastic, aluminium or stainless steel
■ With integrated display and mounting bracket for wall/pipe mounting (optio-nal)
■ Possibility of combining diaphragm seals with sterile connections
Data sheet: PE 86.21
IL-10Intrinsically safe
Accuracy (± % of span): ≤ 0.25 or 0.5Measuring range: 0 … 0.1 to 0 … 25 barSpecial features: ■ Explosion protection in accord-
ance with ATEX, FM, CSA and EAC■ Hastelloy design (optional)■ Highly resistive FEP cable (op-
tional)Data sheet: PE 81.23
BGU, BLMMagnetic switch,Magnetostrictive Sensor
For bypass Level indicatorsData sheet: LM 10.06, LM 10.05
BLRReed sensor
For bypass Level indicatorsData sheet: LM 10.04
Float level sensors
Optoelectronic level switches
OLS-C04OEM level switch, ompact design, refrigerant version, with transistor output
Material: Steel, nickel-plated; glassProcess connection: G ½", ½" NPTPressure: Max. 40 barTemperature: -40 … +100 °CData sheet: LM 31.34
OLS-C05OEM level switch, compact design, high-pressure version
Material: Stainless steel, borosilicateglass
Process connection: G ½"Pressure: Max. 25 barTemperature: -40 … +150 °CData sheet: LM 31.33
LSD-30Electronic level switch, with display
Measuring range: Sensor length 250, 370, 410, 520, 730 mm
Density: ≥ 0.7 g/cm3 (NBR float)Switching output: ■ 1 or 2 (PNP or NPN)
■ Analogue output (optional)Process connection: G ¾ A, ¾ NPTData sheet: LM 40.01
design, refrigerant version, with transistor output
Steel, nickel-plated; glass, ½" NPT
design, refrigerant version, with
Steel, nickel-plated; glassStainless steel, borosilicate
Level sensor, Stainless
Mounting threadFlange: DIN, ANSI, EN
Sensor length 250, 370, 410,
GL
LS-10Standard version
Accuracy (± % of span): ≤ 0.5Measuring range: 0 … 0.25 to 0 … 10 barData sheet: PE 81.55
HLS-PPlastic version, for horizontal installation
Process connection: Flange: DIN, ANSI, ENPressure: 0 … 3 barTemperature: -10 … +80 °CDensity: ≥ 750 kg/mMaterial: PPData sheet: LM 30.02
HLS-SStainless steel version, for horizontal installation
Process connection: Flange: DIN, ANSI, ENPressure: 0 … 232 barTemperature: -196 … +350 °CDensity: ≥ 600 kg/m³Material: Stainless steel, titaniumData sheet: LM 30.02
Magnetic fl oat switches
Pressure level sensors
Mounting thread
BNAStainless steel Version
Material: Austenitic steels, 6Mo, Hastelloy,titanium, Monel, Inconel, Incoloy,Duplex, Super Duplex
Process connection: ■ Flange: DIN, ANSI, EN■ Thread■ Weld stub
Temperature: -160 … +450 °CDensity: ≥ 400 kg/m³Data sheet: LM 10.01
BNA-PPlastic version
Material: PVDF, PPProcess connection: Flange: DIN, ANSI, ENPressure: PVDF 6 bar, PP 4 barTemperature: -25 … +80 °CDensity: ≥ 800 kg/m³Data sheet: LM 10.01
Bypass level indicators
Poster_Water_Level_A1_EN.indd Alle Seiten 24.02.2016 08:15:37
8www.tc-fluidcontrol.com
Level measuring instruments for liquid applications
WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 30∙63911 Klingenberg∙Germany
Tel. +49 9372 132-0∙Fax +49 9372 [email protected]∙www.wika.de
SLSSuspended fl oat switches
Data sheet: LM 32.01
Level measuring instrumentsfor water applications
14156384 02/2016 EN
FLM-SPLevel sensor,plastic version
Process connection: ■ Mounting thread■ Flange: DIN, ANSI, EN
Guide tube length: Max. 5,000 mmPressure: 0 … 16 barTemperature: -10 … +100 °CDensity: ≥ 800 kg/m³Data sheet: LM 20.01
FLM-SLevel sensor, Stainlesssteel Version
Process connection: ■ Mounting thread■ Flange: DIN, ANSI, EN
Guide tube length: Max. 6,000 mmPressure: 0 … 200 barTemperature: -90 … +450 °CDensity: ≥ 400 kg/m³Data sheet: LM 20.01
FLS-SMagnetic fl oat switch,stainless steel version
Switch points: Max. 8 switch pointsProcess connection: ■ Mounting thread
■ Flange: DIN, ANSI, ENGuide tube length: Max. 6,000 mmPressure: 0 … 100 barTemperature: -196 … +300 °CDensity: ≥ 390 kg/m³Data sheet: LM 30.01
FLS-PMagnetic fl oat switch,plastic version
Switch points: Max. 8 switch pointsProcess connection: ■ Mounting thread
■ Flange:DIN, ANSI, EN
Guide tube length: Max. 5,000 mmPressure: 0 … 3 barTemperature: -10 … +100 °CDensity: ≥ 400 kg/m³Data sheet: LM 30.01
DPT-10Diff erential pressure transmitter
Non-linearity(% of span): ≥ 0,075 ... 0,15Measuring range: 0 ... 10 mbar to 0 ... 40 barSpecial features: ■ Freely scaleable measuring ranges
■ Case from plastic, aluminium or stainless steel
■ With integrated display and mounting bracket for wall/pipe mounting (optio-nal)
■ Possibility of combining diaphragm seals with sterile connections
Data sheet: PE 86.21
IL-10Intrinsically safe
Accuracy (± % of span): ≤ 0.25 or 0.5Measuring range: 0 … 0.1 to 0 … 25 barSpecial features: ■ Explosion protection in accord-
ance with ATEX, FM, CSA and EAC■ Hastelloy design (optional)■ Highly resistive FEP cable (op-
tional)Data sheet: PE 81.23
BGU, BLMMagnetic switch,Magnetostrictive Sensor
For bypass Level indicatorsData sheet: LM 10.06, LM 10.05
BLRReed sensor
For bypass Level indicatorsData sheet: LM 10.04
Float level sensors
Optoelectronic level switches
OLS-C04OEM level switch, ompact design, refrigerant version, with transistor output
Material: Steel, nickel-plated; glassProcess connection: G ½", ½" NPTPressure: Max. 40 barTemperature: -40 … +100 °CData sheet: LM 31.34
OLS-C05OEM level switch, compact design, high-pressure version
Material: Stainless steel, borosilicateglass
Process connection: G ½"Pressure: Max. 25 barTemperature: -40 … +150 °CData sheet: LM 31.33
LSD-30Electronic level switch, with display
Measuring range: Sensor length 250, 370, 410, 520, 730 mm
Density: ≥ 0.7 g/cm3 (NBR float)Switching output: ■ 1 or 2 (PNP or NPN)
■ Analogue output (optional)Process connection: G ¾ A, ¾ NPTData sheet: LM 40.01
design, refrigerant version, with transistor output
Steel, nickel-plated; glass, ½" NPT
design, refrigerant version, with
Steel, nickel-plated; glassStainless steel, borosilicate
Level sensor, Stainless
Mounting threadFlange: DIN, ANSI, EN
Sensor length 250, 370, 410,
GL
LS-10Standard version
Accuracy (± % of span): ≤ 0.5Measuring range: 0 … 0.25 to 0 … 10 barData sheet: PE 81.55
HLS-PPlastic version, for horizontal installation
Process connection: Flange: DIN, ANSI, ENPressure: 0 … 3 barTemperature: -10 … +80 °CDensity: ≥ 750 kg/mMaterial: PPData sheet: LM 30.02
HLS-SStainless steel version, for horizontal installation
Process connection: Flange: DIN, ANSI, ENPressure: 0 … 232 barTemperature: -196 … +350 °CDensity: ≥ 600 kg/m³Material: Stainless steel, titaniumData sheet: LM 30.02
Magnetic fl oat switches
Pressure level sensors
Mounting thread
BNAStainless steel Version
Material: Austenitic steels, 6Mo, Hastelloy,titanium, Monel, Inconel, Incoloy,Duplex, Super Duplex
Process connection: ■ Flange: DIN, ANSI, EN■ Thread■ Weld stub
Temperature: -160 … +450 °CDensity: ≥ 400 kg/m³Data sheet: LM 10.01
BNA-PPlastic version
Material: PVDF, PPProcess connection: Flange: DIN, ANSI, ENPressure: PVDF 6 bar, PP 4 barTemperature: -25 … +80 °CDensity: ≥ 800 kg/m³Data sheet: LM 10.01
Bypass level indicators
Poster_Water_Level_A1_EN.indd Alle Seiten 24.02.2016 08:15:37
www.tc-fluidcontrol.com9
Applications � Level measurement of liquids in machine building � Control and monitoring tasks for hydraulic power packs,
compressors and cooling systems
Special features � Media compatibility: Oil, water, diesel, refrigerants and other
liquids � Permissible medium temperature range: -30 ... +150 °C � Up to 4 switching outputs freely definable as normally open,
normally closed or change-over contact � Optional temperature output signal, selectable as
preconfigured bimetal switch or either Pt100 or Pt1000
RLS-1000Stainless steel version
Switch points Up to 4(normally closed, normally open, change-over contact)
Medium temperature -30 … +80 °C-30 … +150 °C optional
Guide tube length 60 … 1,500 mmData sheet LM 50.03
RLS-2000Plastic version
Switch points Up to 4(normally closed, normally open, change-over contact)
Medium temperature -10 … +80 °C-30 … +120 °C optional
Guide tube length 100 … 1,500 mmData sheet LM 50.04
RLS-3000Stainless steel version, with temperature output signal
Switch points Up to 3(normally closed, normally open, change-over contact)
Temperature output Normally closed, normally open, Pt100, Pt1000
Medium temperature -30 … +80 °C(-30 … +150 °C optional)
Guide tube length 60 … 1,500 mmData sheet LM 50.06
Float switches for industrial applications
www.tc-fluidcontrol.com10
Applications � Level measurement of liquids in machine building � Control and monitoring tasks for hydraulic power packs,
compressors and cooling systems
Special features � Media compatibility: Oil, water, diesel, refrigerants and other
liquids � Permissible medium temperature range: -30 ... +150 °C � Up to 4 switching outputs freely definable as normally open,
normally closed or change-over contact � Optional temperature output signal, selectable as
preconfigured bimetal switch or either Pt100 or Pt1000
RLS-1000Stainless steel version
Switch points Up to 4(normally closed, normally open, change-over contact)
Medium temperature -30 … +80 °C-30 … +150 °C optional
Guide tube length 60 … 1,500 mmData sheet LM 50.03
RLS-2000Plastic version
Switch points Up to 4(normally closed, normally open, change-over contact)
Medium temperature -10 … +80 °C-30 … +120 °C optional
Guide tube length 100 … 1,500 mmData sheet LM 50.04
RLS-3000Stainless steel version, with temperature output signal
Switch points Up to 3(normally closed, normally open, change-over contact)
Temperature output Normally closed, normally open, Pt100, Pt1000
Medium temperature -30 … +80 °C(-30 … +150 °C optional)
Guide tube length 60 … 1,500 mmData sheet LM 50.06
LSD-30Electronic level switch, with dis-play
Measuring range Probe length 250, 370, 410, 520, 730 mm (others on request)
Density ≥ 0.88 g/cm3 (stainless steel float)Output signal ■ 1 or 2 switching outputs (PNP or NPN)
■ Analogue output (optional)Process connection G ¾ A, ¾ NPT (others on request)Data sheet LM 40.01
GLS-1000PNP or NPN switching outputs
Switch points Up to 4 (normally closed, normally open)Temperature output Pt100, Pt1000Medium tempera-ture
-40 … +80 °C(-40 … +110 °C optional)
Guide tube length 60 … 1,000 mmAccuracy ≤ 1 mmData sheet LM 50.10
RLS-4000Intrinsic safety Ex i
Switch points Up to 4(normally closed, normally open, change-over contact)
Temperature output (optional)
Normally closed, normally open, Pt100, Pt1000
Medium temperature -30 … +80 °C(-30 … +150 °C optional)
Guide tube length 60 … 1,500 mmData sheet LM 50.07
RLS-5000For the shipbuilding industry (bilge water tanks)
Material Stainless steel 1.4571Switching output Normally closed,
normally open, change-over contact
Medium temperature -40 … +80 °CElectrical output Marine cable, IP68
(8 m)Test device optionalData sheet LM 50.08
RLS-6000For water and wastewater
Switching output Normally closed, normally open, change-over contact
Density ≥ 1,000 kg/m3
Medium temperature -10 … +60 °CGuide tube length 150 … 1,000 mmData sheet LM 50.09
APP ROV EDTYPE
www.tc-fluidcontrol.com11
Level | Switch
FLS-SA, FLS-SBStainless steel version, for vertical installation
Switch points Max. 8 switch pointsProcess connection ■ Mounting thread
■ Flange DIN, ANSI, ENGuide tube length Max. 6,000 mmPressure 0 … 100 barTemperature -196 … +300 °CDensity ≥ 390 kg/m³Data sheet LM 30.01
FLS-PA, FLS-PBPlastic version, for vertical installation
Switch points Max. 8 switch pointsProcess connection ■ Mounting thread
■ Flange DIN, ANSI, ENGuide tube length Max. 5,000 mmPressure 0 … 3 barTemperature -10 … +100 °CDensity ≥ 400 kg/m³Data sheet LM 30.01
Applications � Level measurement for almost all liquid media � Pump and level control and monitoring of distinct filling levels � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry
Special features � Large range of application due to the simple, proven functional
principle � For harsh operating conditions, long service life � Operating limits: □ Operating temperature: T = -196 … +350 °C
□ Operating pressure: P = vacuum to 40 bar□ Limit density: ρ ≥ 300 kg/m³
� Wide variety of different electrical connections, processconnections and materials
� Explosion-protected versions
FLR-HA3Hygienic version, for sanitary ap-plications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.02
VARIVENT® is a registered trademark of the company TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
Float switches for the process industryRobust switches for liquid media
www.tc-fluidcontrol.com12
FLS-SA, FLS-SBStainless steel version, for vertical installation
Switch points Max. 8 switch pointsProcess connection ■ Mounting thread
■ Flange DIN, ANSI, ENGuide tube length Max. 6,000 mmPressure 0 … 100 barTemperature -196 … +300 °CDensity ≥ 390 kg/m³Data sheet LM 30.01
FLS-PA, FLS-PBPlastic version, for vertical installation
Switch points Max. 8 switch pointsProcess connection ■ Mounting thread
■ Flange DIN, ANSI, ENGuide tube length Max. 5,000 mmPressure 0 … 3 barTemperature -10 … +100 °CDensity ≥ 400 kg/m³Data sheet LM 30.01
Applications � Level measurement for almost all liquid media � Pump and level control and monitoring of distinct filling levels � Chemical, petrochemical industry, natural gas, offshore,
shipbuilding, machine building, power generating equipment,power plants
� Process water and drinking water treatment, food and beverageindustry
Special features � Large range of application due to the simple, proven functional
principle � For harsh operating conditions, long service life � Operating limits: □ Operating temperature: T = -196 … +350 °C
□ Operating pressure: P = vacuum to 40 bar□ Limit density: ρ ≥ 300 kg/m³
� Wide variety of different electrical connections, processconnections and materials
� Explosion-protected versions
FLR-HA3Hygienic version, for sanitary ap-plications
Process connection ■ Clamp ISO 2852■ Clamp DIN 32767■ Aseptic thread DIN 11864-1■ Aseptic liner DIN 11864-1■ Aseptic flange DIN 11864-2■ Aseptic clamp DIN 11864-3■ VARIVENT®
■ BioConnect®
Material 1.4435 (316L) or 1.4404 (316L)Guide tube length Max. 6,000 mmPressure 10 barTemperature -40 … +250 °CDensity ≥ 770 kg/m³Data sheet LM 20.02
VARIVENT® is a registered trademark of the company TuchenhagenBioConnect® is a registered trademark of the company NEUMO
®
ELS-SFor lateral mounting with external chamber
External chamber Stainless steelProcess connection Threaded pipe connection GE10-LR
galvanised steelPressure Up to 6 barTemperature -30 … +300 °CData sheet LM 30.03
ELS-AFor lateral mounting with external chamber
External chamber AluminiumProcess connection Threaded pipe connection GE10-LR
galvanised steelPressure Max. 1 barTemperature -30 … +150 °CData sheet LM 30.03
HLS-S Ex iIntrinsically safe stainless steel version for horizontal installation
Process connection ■ Mounting flange: DIN DN 50 … DN 100, PN 6 … 160EN 1092 DN 50 … DN 100, PN 6 … PN 160 ANSI 2" … 4", class 150 … 900
■ Square flange: DN 80 and DN 92 (other flanges on request)
Pressure Max. 6 barTemperature class T2 T3 T4 T5 T6Process temperature 180 °C 160 °C 108 °C 80 °C 65 °CAmbient temperature at case 80 °C
Density 600 kg/m³Material Stainless steel 1.4571Data sheet LM 30.02
HLS-SStainless steel version, for hori-zontal installation
Process connection Flange DIN, ANSI, ENPressure 0 … 232 barTemperature -196 … +350 °CDensity ≥ 600 kg/m³Material Stainless steel, titaniumData sheet LM 30.02
HLS-PPlastic version, for horizontal installation
Process connection Flange DIN, ANSI, ENPressure 0 … 3 barTemperature -10 … +80 °CDensity ≥ 750 kg/m³Material PPData sheet LM 30.02
HLS-M1, HLS-M2Plastic or stainless steel version, with cable outlet
Process connection ■ ½" NPT (installation in the tank from outside)
■ G ¼" (installation in the tank from inside)
Pressure HLS-M1: 1 barHLS-M2: 5 bar
Temperature HLS-M1: -10 … +80 °CHLS-M2: -40 … +120 °C
Material HLS-M1: PPHLS-M2: Stainless steel 1.4301
Electrical connection
HLS-M1: CableHLS-M2: Cable or connector
Data sheet LM 30.06
www.tc-fluidcontrol.com13
Level | Switch
OLS-S, OLS-HStandard and high-pressure version
Material Stainless steel, Hastelloy, KM-glass, quartz glass, sapphire, graphite
Process connection ■ G ½ A ■ ½ NPT
Pressure 0 … 500 barTemperature -269 … +400 °CApproval Ex iData sheet LM 31.01
OSA-SSwitching amplifier, for models OLS-S, OLS-H
Output 1 signal relay, 1 failure relayFunction High or low alarmTime delay Up to 8 sVoltage supply AC 24/115/120/230 V
DC 24 VApproval Ex iData sheet LM 31.01
OLS-C20Compact design, high-pressure version
Material Stainless steel, quartz glassProcess connection ■ M16 x 1.5
■ G ½ A■ ½ NPT
Insertion length 24 mmPressure 0 … 50 barTemperature -30 … +135 °CData sheet LM 31.02
Applications � Chemical, petrochemical, natural gas, offshore industries � Shipbuilding, machine building, refrigerator units � Power generating equipment, power plants � Process water and drinking water treatment � Wastewater and environmental engineering
Special features � Temperature ranges from -269 … +400 °C � Versions for pressure ranges from vacuum to 500 bar � Special versions: High pressure, interface measurement � Explosion-protected versions � Signal processing is made using a separate model OSA-S
switching amplifier
www.tc-fluidcontrol.com14
OLS-S, OLS-HStandard and high-pressure version
Material Stainless steel, Hastelloy, KM-glass, quartz glass, sapphire, graphite
Process connection ■ G ½ A ■ ½ NPT
Pressure 0 … 500 barTemperature -269 … +400 °CApproval Ex iData sheet LM 31.01
OSA-SSwitching amplifier, for models OLS-S, OLS-H
Output 1 signal relay, 1 failure relayFunction High or low alarmTime delay Up to 8 sVoltage supply AC 24/115/120/230 V
DC 24 VApproval Ex iData sheet LM 31.01
OLS-C20Compact design, high-pressure version
Material Stainless steel, quartz glassProcess connection ■ M16 x 1.5
■ G ½ A■ ½ NPT
Insertion length 24 mmPressure 0 … 50 barTemperature -30 … +135 °CData sheet LM 31.02
Applications � Chemical, petrochemical, natural gas, offshore industries � Shipbuilding, machine building, refrigerator units � Power generating equipment, power plants � Process water and drinking water treatment � Wastewater and environmental engineering
Special features � Temperature ranges from -269 … +400 °C � Versions for pressure ranges from vacuum to 500 bar � Special versions: High pressure, interface measurement � Explosion-protected versions � Signal processing is made using a separate model OSA-S
switching amplifier
Optoelectronic switches for the process industryFor applications with limited mounting space
Applications � Limit detection of liquids � Machine tools � Hydraulics � Machine building � Water technology
Special features � For liquids such as oils, water, distilled water, aqueous media � Compact design � Mounting position as required � Accuracy ±2 mm � No moving components
OLS-C01Level switch, standard version
Material Stainless steel, borosilicate glassProcess connection G ⅜", G ½" or M12 x 1Pressure Max. 25 barTemperature -30 … +100 °CSwitching output 1 x PNPData sheet LM 31.31
OLS-C05Level switch, high-temperature version
Material Stainless steel, borosilicate glassProcess connection G ½"Pressure Max. 25 barTemperature -40 … +170 °CSwitching output 1 x PNPData sheet LM 31.33
OLS-C02Level switch, with selectable switch length
Material Stainless steel, borosilicate glassProcess connection G ½"Pressure Max. 25 barTemperature -30 … +100 °CSwitch length 65 … 1,500 mmSwitching output 1 x PNPData sheet LM 31.32
OLS-C51Intrinsic safety Ex i
Material Stainless steel, borosilicate glassProcess connection G ½"Pressure Max. 40 barTemperature -30 … +135 °CApproval Ex iOutput signal 4 … 20 mA low/highData sheet LM 31.04
OLS-C04For refrigeration technology
Material Steel, nickel-plated; glassProcess connection G ½", ½" NPTPressure Max. 40 barTemperature -40 … +100 °CSwitching output 1 x PNPData sheet LM 31.34
OLS-5200For the shipbuilding industry
Material Stainless steel, borosilicate glassProcess connection Male thread G ½" or M18 x 1.5Pressure Max. 25 barTemperature -40 … +130 °CSwitching output 1 x PNPVibration resistance 10 … 5,000 Hz, 0 … 60 gData sheet LM 31.06
www.tc-fluidcontrol.com15
Optoelectronic switches for industrial applications
For applications with limited mounting space
Optoelectronic limit level switches – application specialists
Level | Switch
www.tc-fluidcontrol.com
FLUID CONTROLA division of the WIKA group
TC Fluid ControlUnit 4 The InterchangeWested LaneSwanleyKent BR8 8TE
Tel: +44 (0) 1322 622400Fax: +44 (0) 1322 660621Email: [email protected]
Scotland office:Office 1/05King James Business CentreFriarton Road Perth PH2 8DY
Tel: +44 (0) 1738 472015Fax: +44 (0) 1322 660621Email: [email protected]