Including 1-Zone Controller into Z-Wave® Network:
NOTES:• Ifusinganon-LevitonProgrammer/Remote,refertothe
Programmer/RemoteinstructionsheetforIncludingadevice.• 1-zonecontrollersincludedintoaZ-Wave®networkmustbeupdated
afteryouhaveincludedallotherdevices.• IfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepC.A) IfusingaLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,
presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.Pressthecenterbuttonto<IncludeNode>.
B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace1-zonecontrollerintoprogrammingmode.
C) ToaccessProgrammode,engagetheair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard(refer to figure).Wait5secondsandthenpressthepushpadbackintotheframeandholdpushpaduntiltheLEDturnsAmber.ReleasethepushpadandtheLEDshouldblinkAmber.YouarenowinProgrammingmode.
NOTE:IftheLEDonthe1-zonecontrollerturnssolidRedwhileincluding,therehasbeenacommunicationerror.
D) Whilestandingclosetothe1-zonecontroller(approximately2-5ft.),pressthecenterbuttonontheProgrammer/Remoteto<Include>deviceinthenetwork.NOTE:Onlyonedevicemaybeincludedatanytime.
E) TheVRCPGProgrammer/RemotewillassignaHomeID,NodeIDandNameforthisdevice.
NOTE:ThisinformationwillbestoredintheProgrammer/Remotetobeusedforfuturereference.
NOTE:Youmaynameoreditthenodeofthisdeviceatthistime.F) The 1-zone controller is now installed in the network.
WARNINGS AND CAUTIONS:• ON/OFFLEDandBrightnesslevelLEDfor2-waystatusreporting.• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.• ViziaRF+TMVRCZ11-ZoneDimmingControllerdoesnotcontroltheload,butprovides3-wayor4-wayapplicationstooperatewithViziaRF+TMdimmer.
WARNINGS AND CAUTIONS:• Recommendedminimumwallboxdepthis2-1/2".•Notravelerwiresareneeded.Remotecontrolsviaradiofrequency(RF)technology.• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
1-Zone Dimming Controller/Virtual Matching Dimmer Remote
Cat.No.VRCZ1120VAC,60Hz
INSTAllATION INSTRUCTIONSDI-000-VRCZ1-02A
Changing the color of your 1-Zone Controller:Yourdevicemayincludecoloroptions.Tochangecoloroftheface,proceedasfollows:
Push in side at tab to release
INSTAllING YOUR 1-ZONE CONTROllER
NOTE:UsecheckboxeswhenStepsarecompleted.
WIRING 1-ZONE CONTROllER:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHotwallboxwiretoterminalscrewmarked"BK".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• Proceed to Step 5.
Step 8
Wiring Application:
Hot (Bla c k )
Neutral (White)
BK WH
Green Ground
Line 120 V A C , 60H z
1-Zone Controller
Step 4
Testing your 1-Zone Controller prior to mounting in wall box:
• Positionallwirestoprovideroominoutletwallboxfordevice.
• Ensurethattheword“TOP”isfacingupondevicestrap.
• Partiallyscrewinmountingscrewsinwallboxmountingholes.
NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.
• Restorepoweratcircuitbreakerorfuse.• LEDshouldturnON. If lED does not turn ON, refer to the
TROUBlESHOOTING section.
Step 5
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!
Step 1
Step 3 Preparing and connecting wires:This1-zonecontrollercanbewiredusingsidewireterminalscrewsorthroughbackwireopenings.Chooseappropriatewirestrippingspecificationsaccordingly.
• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).
5/8" (1.6 cm) Strip Gage
(measure bare wire here)Cut
(if necessary)
Side Wire Connection Sidewireterminalsaccept#14AWGsolid wire copper only.
Back Wire (either hole may be used) Backwireopeningsuse#14-12AWGsolid wire copper only.
2
3
1
2
1.Line(Hot)2.Neutral3.Ground
Identifying your wiring application (most common):NOTE:Ifthewiringinyourwallboxdoesnotresemblethisconfiguration,consultaqualifiedelectrician.
Step 2
INTRODUCTION
Leviton’sViziaRF+TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’sViziaRF+TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave®network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.The1-ZoneDimmingController/VirtualMatchingDimmerRemoteiscompatiblewithanyZ-Wave®enablednetwork,regardlessofthemanufacturerandcanalsobeusedwithotherdevicesdisplayingtheZ-Wave®logo.
• ThisisaZ-Wave®Controller
• 3-wayor4-waycontrolwithouttravelerwires
• Controlsdimmingofremoteload
• ON/OFFLEDandBrightnesslevelLED
• Twowaycommunication
• RFreliability
• Easeofinstallation–Nonewwiring
• CompatiblewithotherZ-Wave®enableddevices
FEATURES
Tools needed to install your 1-Zone Controller
Slotted/PhillipsScrewdriver ElectricalTape Pliers Pencil Cutters Ruler
line up tabs and press in sides one at a time to attach
Gently press top of push pad
Restore Power:Restorepoweratcircuitbreakerorfuse. Installation is complete.
Step 7
1-Zone Controller Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.
Step 6
Excluding 1-Zone Controller from Z-Wave® Network:
Including 1-Zone Controller into Z-Wave® Network:
Factory Default:Ifyour1-zonecontrollerisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthe1-zonecontrollertoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthe1-zonecontroller,engagetheair-gapswitchbygentlypressing
thetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard(refer to figure).Wait5secondsandthenpressthepushpadbackintotheframeandholdpushpaduntilthelocatorLEDturnsAmberandthenturnsRed.Releasethepushpad.The1-zonecontrollerisnowreset.Oncethecontrollerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.
CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYPROGRAMMERREMOTE’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINSYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.
DI-000-VRCZ1-02A2008©LevitonMfg.Co.,Inc.
lIMITED 5 YEAR WARRANTY AND EXClUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoleviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,islimitedtofiveyears.leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
Step 8 cont'd
Programmer/Remote Cat. No. VRCPG
NOTE:Programmer/Remotemustbeincloseproximityto1-zonecontrollerwhenincludinginthenetwork.
For additional information, contact leviton’s Techline at 1-800-824-3005 or visit leviton’s
website at www.ViziaRFplus.com
ProtectedunderU.S.PatentNumber6,388,399andpatentspendingandlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthatto
whichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC COMPlIANCE STATEMENT
A) IfusingaLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.Scrolldownandpressthecenterbuttonto<ExcludeNode>.
B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace1-zonecontrollerintoprogrammingmode.
C) ToaccessProgrammode,engagetheair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard(refer to figure).Wait5secondsandthenpressthepushpadbackintotheframeandholdpushpaduntiltheLEDturnsAmber.ReleasethepushpadandtheLEDshouldblinkAmber.YouarenowinProgrammingmode.
NOTE:IftheLEDonthe1-zonecontrollerturnssolidRedwhileexcluding,therehasbeenacommunicationerror.
D) Whilestandingclosetothe1-zonecontroller(approximately2-5ft.),pressthecenterbuttonontheProgrammer/Remoteto<Exclude>devicefromthenetwork.
Step 9
TROUBlESHOOTING
• LocatorLEDoncontrollerdoesnotturnON - Circuitbreakerorfusehastripped. - If1-zonecontrollerispoweredupandLEDdoesnotturnON,
checkwiring.• Zonecontrollerdoesnotoperatelights -Checkassociation. -Ensurethatcontrollerwasproperlyupdated.
OPERATION
DIM/BRIGHT BarBRIGHTEN:PresstherighthalfoftheDIM/BRIGHTBar–Lightsbrightentodesiredlevel.DIM:PressthelefthalfoftheDIM/BRIGHTBar–Lightsdimtodesiredlevel.Ifthereisapoweroutage,whenthepowerisrestored,thelightswillreturntothelastsettingbeforethepowerinterruption.Cleaning:Cleanwithadampcloth.DO NOTusechemicalcleaners.
Virtual Matching Remote Application:Push Pad (Default settings)Turn ON from OFF position:Tap–LightsturnON,LEDturnsOFF.Turn OFF from ON position:Tap–LightsturnOFF,LEDturnsON.
Push Pad
lED
DIM/ BRIGHT
Bar
lED Brightness
Display
Device Association:After inclusion process, you must associate the devices to the controllers. Refer to the Primary Programmer/Controller instruction sheet for complete details.
Step 10
NOTE:One(1)Z-Wave®devicecanbeassociatedtomultipleprogrammer/remotes(uptofive(5)programmer/remotesmaximum).
NOTE:Ifusinganon-LevitonProgrammer/Remote,refertotheProgrammer/RemoteinstructionsheetforAssociatingadevice.
NOTE: Only one Vizia RF +TM dimmer can be associated to the 1-zone controller.
Gently press top of push pad
Definition of ModeLEDOptions:SetsthetimeperiodinsecondstheLocatorLEDandBrightnessdisplaywillstayonbeforeextinguishing.
NOTE:Theswitchwillexitprogrammodeafter3minutesofinactivity.
Program ModeTo enter programming mode:PressandholdthepushpadandthentherighthalfoftheDIM/BRIGHTbar(^)for5secondsuntiltheLocatorLEDstartsandtheleftmostLED(LED1)begintoblink.
TheLocatorLEDwillblinkoncepersecondtoindicateProgramMode,lED Options.TochangeLEDOptionssettingsusetheDIM/BRIGHTbartomovetheLEDtothedesiredpresetsettingaccordingtothechartbelow.Bytappingthepushpad,thissettingwillautomaticallybesavedandthedevicewillexitprogrammingmode.
ADVANCED PROGRAMMING FEATURES
Active
Active
Active
Active
Turns off 5 seconds after use
Turns off 5 seconds after use
Active
Active
Turns off 5 seconds after use
LOCATOR LED TIMEOUT
1
2
3
4
5
6
7
LED
Turns off 5 seconds after use
Turns off 5 seconds after use
LED Bar active
LED Bar turns off 5 seconds after use
LED Bar turns off 5 seconds after use
LED BRIGHTNESS DISPLAY OPTIONS
G) Afteralldevicesareincludedintothenetwork,thecontrollermustbeupdatedtoallowpropernetworkfunction.Toupdatecontrollerproceedasfollows:
• Ifusinganon-LevitonProgrammer/Remote,refertotheProgrammer/Remoteinstructionsheetforupdatingcontroller.
• IfusingLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.PressthecenterbuttontoselectUpdate"cntrl".Whenpromptedpresspushpadonthe1-zonedimmingcontroller.
• WaituntiltheVRCPGProgrammer/Remoteconfirmscompletion.Updateisdone.
NOTE: IfusingtheVRCPG'sInstallChecklistfeature,afteralldevicesareincluded,gotoUpdateControllersstep.NOTE:Ifthe1-zonecontrollerhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutfirstexcludingitfromthenetwork,thecontrollerwillretainthefirstnodeIDithadreceivedandignorethesecond.
Cat. No. VRCPG
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Menu Button