+ All Categories
Home > Documents > Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of...

Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of...

Date post: 15-Jun-2018
Category:
Upload: lytram
View: 216 times
Download: 0 times
Share this document with a friend
20
Vertiv™ SmartAisle™ Data Center Efficiency Management Platform Liebert®
Transcript
Page 1: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

Vertiv™ SmartAisle™

Data Center Efficiency Management Platform

Liebert®

Page 2: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

2

VERTIV™ SMARTAISLE™

Page 3: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

3

Vertiv™Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like ASCO®, Chloride®, Liebert®, NetSure™ and Trellis™, our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running—and your business moving. Together, we’re building the future of a world where critical technologies always work.

YOUR VISION, OUR PASSION.VertivCo.com

Page 4: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

4

VERTIV™ SMARTAISLE™

Reduce energy consumption while supporting higher density for IT and networking equipment - without compromising your requirement for availability.

Data Center Efficiency Management Platform

Raised floor data center with perimeter cooling (Liebert PDX/PCW)

Slab floor data center with Liebert CRVrow-based cooling

Vertiv™ SmartAisle™ is a platform of technologies designed to optimize the efficiency, design and operation of your data center infrastructure.

The Vertiv SmartAisle principle is based on the separation of cold and warm zones, and incorporates special cooling capacity and airflow management, raised floor sealing, cable entry sealing and cabinet sealing with blanking panels.

But it is not just physical separation and sealing of the cold and warm zones that makes this system the most efficient. Knürr CoolFlex® solution together with Liebert® PDX/PCW or Liebert CRV units with sophisticated software developed for cold aisle containment is the best way how to enhance the flexibility, reliability and efficiency of your data center.

The control strategy is based on the main task: to provide such cooling capacity that is actually required by IT equipment.

Therefore Vertiv precision cooling units for SmartAisle maintain the Temperature, Humidity and Airflow within the cold aisle containment.

Vertiv SmartAisle™ Is Ideally Suited For:yy Hot/cold aisle architecture

yy Raised floor data centers with perimeter cooling

yy Non-raised floor data centers using row-based precision cooling systems such as Liebert® CRV+ Knürr CoolLoop

yy Retrofit to existing racks.

Configure SmartAisle™ To Maximize Energy Efficiency And System Availability:yy Vertiv ICOM® control with Vertiv

SmartAisle™ control logic

yy Temperature and Airflow sensors

yy Vertiv Knürr racks

yy Knürr CoolFlex® cold aisle containment system

yy Sealed entry doors

yy Thermal Management systems

yy Knürr cable management system and rack accessories.

Page 5: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

Solution with Liebert® CRV and Knürr CoolFlex® cold aisle containment

5

Page 6: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

6

1. Knürr CoolFlex® cold aisle containmentPhysical separation of cold and warm air zones using Knürr CoolFlex technology. Cold aisle containment ensures that the cold air distributed through the raised floor or row-based cooling units is delivered directly to IT cabinets without mixing with warm air from the hot aisle.

2. Vertiv ICOM® with Vertiv SmartAisle Control LogicThe Vertiv ICOM control system featured on Thermal Management products brings high-level control and supervision to multiple units, allowing up to 32 cooling units to work together as a single system to optimize room performance. The Vertiv ICOM Control is present on Liebert® HPC Chillers, Liebert PCW and Liebert CRV units. A cooling unit with Vertiv SmartAisle control logic ensures the proper airflow, air temperature and humidity required by IT equipment. Dynamic fan speed and cooling capacity control provides maximum cooling efficiency.

3. Liebert PCWOffers two versions in terms of hydraulic circuit:

yy Traditional single circuit CW models

yy Dual circuit CW models for high redundancy.

Flexibility and the best efficiency is achieved using EC fan technology and Vertiv SmartAisle control logic.

4. Liebert CRV Row-based precision cooling systems available in 40kW version with horizontal airflow. Liebert CRV units, as a standard, equipped with EC fans, variable cooling capacity control and humidity control unsure to provide the correct operating conditions for IT equipment at the best energy efficiency.

5. Liebert® HPC Wide range of high energy efficient chillers available in air or water cooled configuration and for outdoor or indoor application. Freecooling chillers in combination with Vertiv SmartAisle architecture allow the achievement of extraordinary energy savings and increased system lifetime thanks.

6. Knürr Racks The Knürr server racks allow for flexible mounting of accessories, as well as a complete cable management system. The server rails guarantee easy mounting of all types of 19” servers and Liebert/Knürr accessories.

With fully perforated doors (83% open area) this enclosure is set upfor optimal thermal and airflow management.

7. Vertiv SmartAisle Equipment The Vertiv SmartAisle solution also incorporates additional improvements in cooling efficiency side, which can be achieved using the following equipment:

yy Cable entry sealing systems

yy Cabinets sealing with trims and blanking panels

yy High air flow perforated floor tiles with perforation up to 85% can offer more than doubled airflow in comparison with standard floor tiles or significantly increase efficiency thanks to minimized pressure drop.

Savings - Chilled Water System 36.7% 47.9%TraditionalApproach

With Cold Aisle Containment

With VertivSmartAisle

Chiller* 54.8% 41.5% 35.2%

Pumps* 10.5% 9.7% 9.6%

Cooling Unit 34.7% 12.0% 7.4%

Total 100% 63.3% 52.1%

Vertiv SmartAisle solution in combination with chilled water system with free cooling is the best practice how to maximize energy efficiency. This result has been reached by enhancing free cooling effect thanks to using higher fluid temperature.

VERTIV™ SMARTAISLE™

Vertiv™ SmartAisle™: Chilled Water System

Page 7: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

7

5

1 32

7

6

4

Page 8: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

8

VERTIV™ SMARTAISLE™

1. Knürr CoolFlex® cold aisle containmentPhysical separation of cold and warm air zones using Knürr CoolFlex® technology. Cold Aisle Containment ensures that the cold air distributed through the raised floor or row-based cooling units is delivered directly to IT cabinets without mixing with warm air from the hot aisle.

2. Vertiv ICOM® with Vertiv SmartAisle Control LogicThe Vertiv ICOM control system featured on Liebert® Precision Cooling products brings high-level control and supervision to multiple units, allowing up to 32 cooling units to work together as a single system to optimize room performance. Vertiv ICOM controller is present on Liebert® HPC Chillers, Liebert PDX and Liebert CRV units. A cooling unit with Vertiv SmartAisle control logic ensures the proper airflow, air temperature and humidity required by IT equipment. Dynamic fan speed and cooling capacity control provides maximum cooling efficiency.

3. Liebert PDXOffers flexibility in design with air/water cooled or freecooling single circuit DX models equipped with digital scroll compressor adaptable for variable cooling capacity needs. Flexibility and the best efficiency for all Liebert PDX units is achieved using EC fan technology.

4. Liebert CRV Row-based precision cooling systems available in water and air cooled Direct Expansion version with Digital Scroll Compressor featuring modular cooling capacity up to 35kW. Suitable for data centers where a raised floor is not available for cooling. Liebert CRV units, as standard, are equipped with EC fans, Digital Scroll compressor and humidity control to provide the right operating conditions for IT equipment at the best energy efficiency.

5. Liebert® HPA Remote air cooled condenser for precision room cooling units equipped with variable fan speed control specific developed for Digital Scroll solutions.

The Energy Efficient Solution maximises the system efficiency reducing the consumption during all year long.

6. Knürr Racks The Knürr server racks allow for flexible mounting of accessories, as well as a complete cable management system. The server rails guarantee easy mounting of all types of 19” servers and Liebert /Knürr accessories. With fully perforated doors (83% open area) this enclosure is set up for optimal thermal and airflow management.

7. Vertiv SmartAisle Equipment The Vertiv SmartAisle solution also incorporates additional improvements in cooling efficiency which can be achieved using the following equipment:

yy Cable entry sealing systems

yy Cabinet sealing with trims and blanking panels

yy High Air Flow Perforated Floor Tiles with perforation up to 85% can offer more than doubled airflow in comparison with standard floor tiles or significantly increase efficiency thanks to minimized pressure drop.

Vertiv SmartAisle solution in combination with direct expansion system can offer more than 34% saving thanks to intelligent control of Digital Scroll Compressor capacity and accurate fan speed management driven by cold aisle conditions. Vertiv SmartAisle solution provides consistently hot return air for more effective precision cooling system performance.

Vertiv™ SmartAisle™: Direct Expansion System

Savings - Direct Expansion System 20,2% 34,3%TraditionalApproach

With Cold Aisle Containment

With VertivSmartAisle

Compressor 72.2% 59.2% 55.2%

Condenser 5.8% 5.8% 5.8%

Evaporator Fan 22.0% 14.9% 4.7%

Total 100% 79.8% 65.7%

Page 9: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

9

5

13

2

7

64

Page 10: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

10

VERTIV™ SMARTAISLE™

Knürr IT Rackyy Industry leading 83% perforation

for high density IT equipment

yy Dozens of simple tool-less accessories

yy Significant zero-U mounting space

yy Roof designed for optional high density cooling.

Liebert® and Vertiv™ Knürr Rack PDUyy Basic, controlled or adaptive designs

yy Local and remote monitoring

yy Additional in-rack sensors available

yy Available in low and high density

yy 2-years no-hassle replacement warranty.

Knürr CoolFlex®yy Flexible design independent from

rack width

yy Swinging or sliding doors

yy Overhead panels

yy Integrated adaptive control reduces fan energy cost.

IT RACKS AND ACCESSORIES

Vertiv Nformyy Software solution providing

centralized monitoring of a wide range of data center infrastructure equipment

yy Leverages existing network communications

yy Triggers event actions or notifications.

Vertiv SiteScan Webyy Software solution providing

centralized monitoring of a wide range of data center infrastructure equipment

yy Leverages existing network communications

yy Triggers event actions or notifications.

Liebert APMyy Scalable capacity growth without

increasing footprint

yy Parallel configurations for capacity or redundancy

yy Operates with up to 96% energy efficiency

yy In-the-row installation

INFRASTRUCTURE MANAGEMENT POWER AND UPS

Page 11: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

11

THERMAL MANAGEMENT

Liebert® CRVyy 20kW to 40kW precision cooling with

horizontal airflow design for both non-raised and raised floors

yy Digital scroll compressor and variable speed fans for highly efficient operation

yy Air, water, glycol and chilled water designs

yy Vertiv™ ICOM® for intelligent control, communications and monitoring.

Knürr CoolLoopyy Water cooled cabinet for side

mounting on server cabinets

yy Available in single units from 10 to 30kW cooling capacity

yy Flexibility in terms of cooling capacity modulation from 0-100%

yy In combination with Liebert PDX/PCW and Vertiv SmartAisle offers ideal solution for higher density applications

yy Fans with EC motor technology for highly efficient cooling.

Liebert PDXyy Available from 15 to 120kW cooling

range

yy Flexibility of design with air, water, dual-fluid and freecooling mode

yy The Vertiv ICOM Control for intelligent communications and monitoring

yy Digital scroll technology for variable capacity control and optimal efficiency

yy Liebert EC Fans 2.0 to maximize energy efficiency.

Liebert PCWyy Available from 30 to 220kW cooling

range

yy The Vertiv ICOM Control for intelligent communications and monitoring

yy Flexibility of design with fan in the raised floor or base module

yy Optimized energy efficiency thanks to maximized coil surface and air distribution.

Liebert HPCyy High Energy efficiency freecoling

chiller

yy For data center application from 42kW to 1600kW

yy Freecooling option to maximize energy efficiency

yy Variable cooling capacity thanks to semi-hermetic screw or multiple scroll compressors

yy Veretiv ICOM for intelligent control, communications and monitoring

yy Liebert HPC-R available also for indoor application with ducted condenser side from 40kW to 320kW cooling capacity

yy Available also for urban applications thanks to Low-noise and Quiet option.

Page 12: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

12

VERTIV™ SMARTAISLE™

Vertiv™ SmartAisle™ Application Scenarios: Examples Of Data Center Rooms

The traditional approach considers open aisle architecture with the return air temperature to cooling units between 24-26ºC having a supply air temperature between 10-14ºC from the CRAC units. The heat load per rack is in the range of 3 to 5kW/rack.

Row-based cooling units can also satisfy higher heat load density but for large

data centers the space taken for the cooling units placed in the row of racks make this solution questionable. To cope with such issues, Liebert® has in fact developed Liebert® XD which has a zero floor space occupancy in combination with the perimeter cooling. For small and medium data center the in the row cooling is a preferable choice; the cooling units can be direct expansion or chilled

water if the building is designed to handle water pipes, chiller and water containment systems. Usually the best choice is to use direct expansion cooling units in the small and medium capacity data centers while using Chilled water in the large ones.

Chilled water systems deliver high energy efficiency when the chillers are equipped with Freecoolingand are integrated with cooling units.

IT R

acks

IT R

acks

100%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

Traditional Approach

14 C°

24 C°

14 C°

IT R

acks

IT R

acks

70%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

Cold Aisle Containment 0 C°

0 C°

0 C°

IT R

acks

IT R

acks

60%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

SmartAisle™ 32 C°

19 C°

19 C°

Using Vertiv SmartAisle solution most of the Traditional Approach limitations can be significantly improved.

Vertiv SmartAisle solution increases space efficiency with heat load limit up to 12 kW/rack with Liebert® PDX/PCW units and up to 20 kW/rack with Liebert CRV cooling units. Vertiv SmartAisle provides

always uniform and predictable temperature to all IT equipment controlling directly Cold Aisle temperature and humidity.

Optimized cooling system efficiency is achieved by optimising the return air temperature without compromising reliability.

In combination with free cooling chilled water system it can provide up to 50%+ efficiency increase and consequently fast return of investment (ROI). Vertiv SmartAisle allows easy retrofit and low initial investment as it fits existing Knürr racks.

IT R

acks

IT R

acks

100%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

Traditional Approach

14 C°

24 C°

14 C°

IT R

acks

IT R

acks

70%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

Cold Aisle Containment 0 C°

0 C°

0 C°

IT R

acks

IT R

acks

60%

Fan

Spee

d

Prec

isio

nC

oolin

g U

nit

SmartAisle™ 32 C°

19 C°

19 C°

Vertiv SmartAisle

Traditional Approach

Page 13: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

13

Small Data Center

yy Footprint: 20-50m2

yy Up to 150 kW total heat load

yy Up to 20 Racks

yy Recommended solution

y if raised floor is available: Liebert® PDX Direct Expansion

y if raised floor is not available: Liebert CRV Direct Expansion.

Case Study: Direct Expansion System With Perimeter CRAC Units

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

Stand By

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

Liebert®

HPMLiebert®

HPM

Liebert®

HPMLiebert®

HPM

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

STANDARDSCROLL CRAC

Stand By

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

Liebert®

HPMLiebert®

HPM

Liebert®

HPMLiebert®

HPM

yy Pay Back Period less than 15 months (Considering price for electric energy 0.1 ¤/kWh)

yy Reduced footprint: 42.9% saving – considering also the Data Center foootprint reduction the Pay Back Period will be significantly shorter

yy Reduced Racks Qty: 50% saving

yy Increased efficiency: 40.2% energy saving

yy Continuous dynamic adaptation to load

yy Higher reliability increase in available cooling capacity

yy Minimized hot spot risks.

VERTIV™ SMARTAISLE™ BENEFITS:

TRADITIONAL APPROACH VERTIV SMARTAISLE

Data Center Heatload (kW) 100 100

Location Munich, Germany

Racks Qty (.) 20 10

Min. Data Center footprint (m2) 84 48

Redundancy for CRAC units (.) N+1 N+1

CRAC unit type (.) Traditional 35kW unit with standard scroll compressor PX045DA

Condenser (.) Dedicated condenser with VSD HCR43

CRAC Qty (.) 4 4

Heatload per Rack (kW) 5 10

Annual energy consumption of the system (kWh) 287934 172080

Traditional Approach

Vertiv SmartAisle

Page 14: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

14

VERTIV™ SMARTAISLE™

Small Data Center

yy Footprint: 20-50m2

yy Up to 150 kW total heat load

yy Up to 20 Racks

yy Recommended solution

y if raised floor is available: Liebert® PDX Direct Expansion

y if raised floor is not available: Liebert CRV Direct Expansion.

Case Study: Direct Expansion System With Row-Based CRAC Units

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRVLiebert®

CRV

Liebert®®

CRVLiebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRVLiebert®

CRV

Liebert®

CRVLiebert®

CRV

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRVLiebert®

CRV

Liebert®®

CRVLiebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRVLiebert®

CRV

Liebert®

CRVLiebert®

CRV

SMA

RT A

ISLE

yy Pay Back Period less than 4 months (Considering price for electric energy 0.1 ¤/kWh)

yy Reduced footprint: 22,2% saving – considering also the Data center foootprint reduction the Pay Back Period will be reduced to 0 months

yy Reduced Racks Qty: 28% saving

yy Increased efficiency: 9% energy saving

yy Higher reliability increase in available cooling capacity.

TRADITIONAL APPROACH VERTIV SMARTAISLE

Data Center Heatload (kW) 100 100

Location Munich, Germany

Racks Qty (.) 14 10

Min. Data Center footprint (m2) 54 42

Redundancy for CRAC units (.) N+1 N+1

CRAC unit type (.) CRO35 RA CRO35 RA

Condenser (.) HCR051 HCR051

CRAC Qty (.) 4 4

Heatload per Rack (kW) 7.15 10

Annual energy consumption of the system (kWh) 239380 217868

Traditional Approach

Vertiv SmartAisle

VERTIV™ SMARTAISLE™ BENEFITS:

Page 15: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

15

Mid-Size Data Center

yy Footprint: 50-200m2

yy Total Heat load 150 - 500 kW

yy Between 20 to 50 Racks

yy Recommended solution

y if raised floor is available: Liebert® PCW

y if raised floor is not available: Liebert CRV CW.

Case Study: Chilled Water System With Row-Based CRAC Units

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

Liebert®

CRV

SMA

RT A

ISLE

yy Pay Back Period 0 months (immediate return of investment thanks to saving on investment to racks)

yy Reduced Racks Qty: 37,5% saving

yy Reduced footprint: 29.4% saving

yy Increased efficiency: 9% energy saving

yy Higher reliability increase in available cooling capacity.

TRADITIONAL APPROACH VERTIV SMARTAISLE

Data Center Heatload (kW) 200 200

Location Munich, Germany

Racks Qty (.) 32 20

Min. Data Center footprint (m2) 93.5 66

Redundancy for CRAC units (.) N+1 N+1

CRAC unit type (.) CR040 RC CR040 RC

CRAC Qty (.) 8 8

Freecooling Chiller (.) FG0023 FG0023

Fluid 35% Ethylene Glycol (°C) 10/!5 14/19

Heatload per Rack (kW) 6.25 10

Annual energy consumption of the system (kWh) 304438 242670

Power input of pumps is not considered

Traditional Approach

Vertiv SmartAisle

VERTIV™ SMARTAISLE™ BENEFITS:

Page 16: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

16

VERTIV™ SMARTAISLE™

Large Data Center

yy Footprint: >200m2

yy Total Heat load >500 kW

yy More than 50 Racks

yy Recommended solution

y Liebert® PCW

Case Study: Chilled Water System With Perimeter CRAC Units

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPMLiebert®

HPMLiebert®

HPMLiebert®

HPM

Liebert®

HPM

Liebert®

HPM

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

Liebert®

HPMLiebert®

HPMLiebert®

HPM

TRADITIONAL APPROACH

Data Center Heatload (kW) 640

Location Munich, Germany

Racks Qty (.) 150

Min. Data Center footprint (m2) 332.5

Redundancy for CRAC units (.) N+1

CRAC unit type (.) PH110DC

CRAC Qty (.) 8

Freecooling Chiller (.) FG4075

Fluid 35% Ethylene Glycol (°C) 10/!5

Heatload per Rack (kW) 4.27

Annual energy consumption of the system (kWh) 1156291

Power input of pumps is not considered

Traditional Approach

Page 17: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

17

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPM

Liebert®

HPMLiebert®

HPMLiebert®

HPMLiebert®

HPM

Liebert®

HPM

Liebert®

HPM

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

RACK

SMA

RT A

ISLE

Liebert®

HPMLiebert®

HPMLiebert®

HPM

yy Pay Back Period 0 months (immediate return of investment thanks to saving on investment to racks and CRAC units)yy Reduced Racks Qty: 56% savingyy Reduced footprint: 43.2%% savingyy Reduced CRAC Qty: 12,5% energyyy Increased efficiency: 42,6% energy savingyy Minimized hot spot risks for long rows of racksyy Higher reliability and redundancy increase in available cooling capacity.

VERTIV™ SMARTAISLE™ BENEFITS:

Vertiv SmartAisle

VERTIV SMARTAISLE

Data Center Heatload (kW) 640

Location

Racks Qty (.) 66

Min. Data Center footprint (m2) 189

Redundancy for CRAC units (.) N+2

CRAC unit type (.) PH110DC

CRAC Qty (.) 7

Freecooling Chiller (.) FG4075

Fluid 35% Ethylene Glycol (°C) 14/20

Heatload per Rack (kW) 9.3

Annual energy consumption of the system (kWh) 663793

Power input of pumps is not considered

Page 18: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

18

VERTIV™ SMARTAISLE™

Thermal Management Data Center Infrastructure for Small and Large Applications

Liebert EFC Indirect evaporative freecooling unit leveraging on data center know-how. Available from 100 to 350 kW

yy Unique control capabilities optimizing water and energy costs

yy Substantial reductions and savings in terms of electrical infrastructure.

Liebert PDX Liebert PCW Available from 5-220 kW

yy Premium energy efficiency

yy Eurovent certified performance

yy Unique control capabilities with the Vertiv ICOM Control

yy Liebert® EconoPhase™ available for the direct expansion system.

Liebert® HPC Wide range of high efficiency Freecooling Chillers from 40 kW to 1600 kW

yy Designed specifically for data center applications and to work with Vertiv™ SmartAisle™

yy Premium energy efficiency version

yy Unique control capabilities with the Vertiv ICOM™ Control.

Vertiv™ Trellis™ Platform

Vertiv’s TrellisTM platform is a real-time infrastructure optimization platform that enables the

unified management of data centre IT and facilities infrastructure. The Vertiv Trellis platform

software can manage capacity, track inventory, plan changes, visualize configurations, analyze

and calculate energy usage, and optimize cooling and power equipment. The Vertiv Trellis

platform monitors the data center, providing a thorough understanding of system dependencies

to help IT and facilities organizations keep the data center running at peak performance. This

unified and complete solution, delivers the power to see the real situation in your data center,

make the right decision and take action with confidence.

Page 19: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

19

Liebert AFC The Adiabatic Freecooling Chiller available from 500-1450 kW

yy Integrated adiabatic pad system

yy High freecooling capacity

yy 100% compressor back up.

Vertiv SmartAisle™

yy Aisle containment

yy Provides highest energy efficiency

yy Works with any Liebert Thermal Management unit.

Liebert DCL Closed loop rack cooling

yy Two different architectures: Closed Loop Hybrid Loop

yy Multiple combinations for up to 4 server racks

yy Dual CW coil version for redundancy.

SERVICES

VERTIV™ LIFE™ SERVICES

Vertiv supports entire critical infrastructures with the largest global service organization and an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7.

Our approach to servicing critical infrastructure covers all aspects of availability and performance: from single power and thermal management equipment to entire mission-critical systems.

The most comprehensive insurance for business protection can be obtained with a service program from Vertiv which includes access to Vertiv LIFE™ Services.

Vertiv LIFE Services provides Remote Diagnostics and Preventive Monitoring for UPS and thermal management equipment.

Vertiv LIFE Services delivers increased uptime and operational efficiency by enabling continuous monitoring of your equipment, expert data analysis and field engineering expertise.

Through the data transferred from your equipment via Vertiv LIFE Services, our Remote experts gain the real-time insight and information needed to quickly identify, diagnose, and resolve any irregularities that may arise in operation, ultimately taking responsibility for your critical assets 24/7.

Liebert CRV Row-based high efficiency cooling units available from 10-60 kW in DX and CW versions

yy Full airflow and cooling capacity modulation to match server load and to save energy

yy Best footprint capacity with the highest efficiency

yy Six different control modes to ensure greater flexibility.

Page 20: Liebert® - Dataromskjøling g' rowing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented

MKA4L0UKSMA Rev.2-11-2013

VertivCo.com | Emerson Network Power Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827

© 2016 Vertiv Co. All rights reserved. Vertiv™, the Vertiv logo, Liebert® HPC, Liebert PDX, Liebert PCW, Liebert HPA, Liebert EFC, Liebert CRV, Liebert XD, Vertiv ICOM™ , Vertiv SmartAisle™, Vertiv Trellis™, Vertiv LIFE™ Services, Knürr CoolFlex® and Knürr Racks are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.


Recommended