+ All Categories
Home > Documents > Liebert HIROSS Headquarters Via Leonardo da Vinci, 8 35028

Liebert HIROSS Headquarters Via Leonardo da Vinci, 8 35028

Date post: 03-Feb-2022
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
20
Transcript

Liebert HIROSS HeadquartersVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)- Italytel. +39 049 9719111 fax +39 049 5841257

www.liebert-hiross.com - [email protected]

High Performance Air ConditioningVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)tel. +39 049 9719111 fax +39 049 5841257

[email protected]

Uninterruptible Power Supply (UPS)Via Gioacchino Rossini, 6

20098 - San Giuliano Milanese (MI)tel. +39 02 98250 1 fax +39 02 98250337

[email protected]

Liebert HIROSS ServicesVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)- Italytel. +39 049 9719111 fax +39 049 9719045

[email protected]

www.liebert-hiross.com

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

Liebert HIROSS in Europe

Emerson Network Power GesmbH - AustriaHandelskai 102-112 - 1200 Wientel. +43 1 331890 fax +43 1 331892450

Emerson Network Power NV - BelgiumInterleuvenlaan 50B-3001 LEUVENtel. +32 16 380222 fax. +31 16 380227

Liebert HIROSS - Czech RepublicNa Pricce 72/6 – 14200 Praha 4tel. +42 02 41727954 fax +42 02 41718717

Emerson Network Power S.A. - France124 Avenue Gallieni - 93170 Bagnolettel. +33 1 43600177 fax +33 1 43607007

Emerson Network Power GmbH- GermanyLiebigstrasse 9 - 85551 Kirchheimtel. +49 89 9050070 fax +49 89 90500710

Emerson Network Power Kft. - Hungary1146 BudapestErzsébet királyné útja 1/ctel. + 36 1 273 3890 fax. +36 1 422 0621, +36 1 273 3897

Liebert HIROSS Italia S.r.L. - ItalyVia Gioacchino Rossini, 620098 - San Giuliano Milanese - Milanotel. +39 02 982501 fax +39 02 98250273

Emerson Network Power B.V. - NetherlandsRooseindsestraat 295705 BP HELMONDtel. +31 492 508520 fax. +31 492 508525

Emerson Network Power Sp z.o.o.- PolandUl. Konstruktorska, 11A - PL - 02-673 Warszawatel. +48 22 5485260 fax +48. 22 5485261

Emerson Network Power and Liebert HIROSS – RUSSIA, CISMalaya Trubetskaya Str. 8Korp. B, 11th floor - 119881 Moscowtel. +7 095 2329473 fax +7 095 2320358

Emerson Network Power SA- SpainEduardo Torroja, 23Poligono Ind. Leganes - 28914 Leganes - Madridtel. + 34 91 4957700 fax + 34 902 181936

Emerson Network Power AG - SwitzerlandRaeffelstrasse 29 - 8045 Zürichtel. +41 1 456 50 60 fax +41 1 456 50 70

Emerson Network Power Ltd – United KingdomFourth Avenue, Globe Park - MarlowBuckinghamshire - SL71YGtel. +44 1628 403200 fax +44 1628 403203

Addresses updates and further informationavailable in www.liebert-hiross.com - Contacts

Mob

ile P

rodu

ct G

uide

/103

692/

09-

004/

Cop

ista

mpa

/Prin

ted

in I

taly

Liebert HIROSS: Your Partner For An Easier Network Roll-Out

Thermal Consulting

���������������� ����������������������������������������� ���������������������������������������

Quality

����� !"�# ���������������������������������������������������������$������������%�����������������

Training

&����������������������� ���������������������������������������������������������������$������������������������������������������������������'�������������������������������������������

Dedicated Key-account

% ���������������������������$����������������'�����������������������������

Flexible Production

����$�����������������������������������������������������������������������������������������������������������������������������������

Competitive Solution

(����)��������������'����������������������������������������������

Project Co-ordination

*���������������������������������������������������������������������

Worldwide Service

*���� ���������� ������������+��������������$����������,'�����������������������������$���������$�����������������������������������������'���

Liebert HIROSS SolutionsSeries Type Airflow Cooling Typical Application

Cooling Freecooling Emergency Heating Filtration

Operations

HilineDisplacement

&������������-���+.&��������.,

/���������+0�'�*���������0����,

5-151�2����������������������

Hisp ���������-���+.&��������������������������,

(���3�����4������

5-14�������������������

Hiwall TT �������+.&��������.,

5����' 5-211�2�����������������������

Hiwall TD �������+.&��������.,

/�'����' 6-141�2�����������������������

Hiline U/O &������������-���+.&��������.,

5���������

5-151�2����������������������

CabinetCooler

6���������������-����+.&��������������������������,

/�'����'�*������0����

3-61�2����������������������

MiniCooler

%���������6�����+.&��������������������������,

/�'����' 4.81�2����������������������

Hicab %�����������������������������������������������+.�������1�'����.&�,

*����� 1.26�������������������

Hitherm *����� 0.55*7������������� ������

Freecoling

%�����������������������������������������������+.�������1�'����.&�,

Supply Capacity (kW)

��������������������� �*�����������������������������������������������������������������������������

Your Partner For An Easier Network Roll-Out

Hiwall-TT

HIGH PERFORMANCE AIR CONDITIONING

Hiwall TT is the newest package, direct expansion typeair conditioner range, with built-in air cooled condenser,for outdoor installation. Optimised for UMTS networksas far as unique features, cooling capacity and userfriendliness are concerned.

Faster Start-Up

The cooling circuit is pre-charged, fine tuned and fully testedbefore delivery. No pressure test is required on site. Installationis speeded up by using the fast-plug electrical connections (onrequest) and the automatic commissioning software: installa-tion and commissioning are completed in less than 25 minswithout need of specialized personnel on site.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Hiwall TT can be powered by either 48VDC or 230/1/50 incase of mains failure, ventilating and maximising freecoo-ling to keep the indoor temperature below the shut-downlimit and guarantee continued operation of the telecommu-nication equipment.

Low Noise

Hiwall TT is designed to perfectly suit installation in urbansites, where low noise level is of the highest value.That is assured by the careful selection of low noise compo-nents and by the enhancement of cabinet rigidity whicheliminates spurious vibrations.

Invest-As-You-Grow

Wall cut-outs among Hiwall TT models are compatible: theunit can be replaced by a more powerful one when theheat load increases significantly: the right solutions for fle-xibility and reduced investment costs when rolling out 2Gand 3G networks.

Vandal Proof

Heavy gauge steel cabinet with special openings andscrews protect sensitive components.

General Features

Model Hiwall TT 05 06 08 10 13 15 18 21Air supply - upflowMain power supply 230 / 1N / 50 | 400 / 3N / 50Emergency power supply (opt) 48V DC or 230 / 1N / 50PerformancesTotal cooling capacity (1) kW 5,0 5,7 8,1 10,4 12,7 15,5 18,3 20,6Sensible cooling capacity (1) kW 5,0 5,4 8,1 10,0 12,3 15,5 17,6 19,6Compressor AC power input (1) kW 1,62 2,20 1,87 2,83 3,75 4,25 5,19 5,62Condenser fan AC power input (1) kW 0,20 0,20 0,24 0,24 0,24 0,23 0,23 0,73Evaporator fan AC power input (1) kW 0,14 0,14 0,37 0,37 0,48 0,72 0,72 0,88Evaporator fan DC power input (1) kW 0,11 0,11 0,31 0,31 0,39 0,62 0,62 0,78Evaporator airflow m3/h 1520 1520 2.900 2.900 3.100 4.900 4.900 5.200Condenser max. airflow m3/h 2400 2400 4.000 4.000 4.000 4.900 4.900 6.900Freecooling max. airflow m3/h 1300 1300 2.600 2.600 2.800 3.600 3.600 3.850Outdoor sound pressure level (2) dB(A) 52 54 52 53 54 56 57 62Indoor sound pressure level (2) dB(A) 51 51 56 56 57 58 59 60Max. ambient temperature (3) °C 50 47 48 46 45 47 46 45Refrigeration CircuitCompressor type / quantity - scroll/1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity / type / poles AC version - 1/plug/4 | 2/plug/4Quantity / type / poles DC version 1/plug/- | 2/plug/-Driven / motor protection - direct/IP44 | direct/IP54Condenser FanQuantity / type / poles 1/axial/6 | 1/axial/4Driven / motor protection - direct/IP54Control system variable speedFilter type / efficiency (CEN-EU) pleated/G3Electric heating (opt) kW 3,0 | 4,5 | 6,0CabinetFrame - galvanized steelPainting polyester - RAL 7035Insulation type / Thickness -/mm polyurethane class A1/10Width mm 855 | 936 | 1010Depth mm 490 | 630 | 760Height mm 1800 | 2.125 | 2.250Weight kg 165 170 242 245 247 328 331 332

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply.(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions.(3) Maximum outdoor temperature referred to indoor air temperature =24°C.

Hiwall-TD

HIGH PERFORMANCE AIR CONDITIONING

Hiwall TD is the newest package outdoor and downflowair conditioner with built-in air cooled condenser anddirect expansion cooling mode. Downflow air deliveryoptimises the air distribution among the telecommunica-tions equipment and reduces the rack core temperature.

Faster Start-Up

The cooling circuit is pre-charged, fine tuned and fully testedbefore delivery. No pressure test is required on site. Installationis speeded up by using the fast-plug electrical connections (onrequest) and the automatic commissioning software: installa-tion and commissioning are completed in less than 25 minswithout need of specialized personnel on site.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Hiwall TD can be powered by 48VDC emergency power sour-ce in case of mains failure. Continued ventilation and theoptional maximised freecooling assure constant operation ofthe telecommunications equipment and continued revenuefrom the site. 230/1/50 emergency supply is also available asan option.

Vandal Proof

Heavy gauge steel cabinet with special openings andscrews protect sensitive components.

Low Noise

Hiwall TD is especially suitable for urban sites. The conden-ser fan has vertical discharge and fan speed regulator thatresult in extremely low noise level.

High Energy Efficency

Hiwall TD supplies cooled air into the room at ground leveland extracts the air from the top where the temperature ishigher. This increases energy efficiency of the unit in directexpansion and freecooling working modes, allowing emer-gency cooling at higher outdoor temperatures; the result iscontinued availability of the electronic equipment.

General Features

Model Hiwall TD 06 08 10 14Air supply DownflowMain power supply 400 / 3N / 50Emergency power supply (opt) 48V DC or 230 / 1N / 50PerformancesTotal cooling capacity (1) kW 6,3 8,0 10,8 13,3Sensible cooling capacity (1) 6,0 7,8 10,5 12,4Compressor AC power input (1) kW 1,71 1,97 2,97 3,65Condenser fan AC power input (1) kW 0,14 0,26 0,27 0,27Evaporator fan AC power input (1) kW 0,14 0,39 0,48 *Evaporator fan DC power input (1) kW 0,11 0,27 0,40 0,60Evaporator airflow m3/h 1.480 2.160 2.830 3.100Condenser max.airflow m3/h 2.120 3.800 3.700 3.700Freecooling max.airflow m3/h 1.050 1.550 2.030 2.550Outdoor sound pressure level (2) dB(A) 48 51 52 55Indoor sound pressure level (2) dB(A) 55 53 54 62Max.ambient temperature (3) °C 48 50 48 47Refrigeration CircuitCompressor type/quantity scroll/1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity/type/poles AC version 1/plug/4 *Quantity/type/poles DC version 1/plug/- 2/plug/-Driven/motor protection direct/IP44Condenser FanQuantity/type/poles 1/axial/8 1/axial/6Driven/motor protection direct/IP54Control system variable speedFilter type/efficiency (CEN-EU) pleated/G3Electric heating (opt) kW 3,0 4,5CabinetFrame galvanized steelPainting Polyester - RAL 7035Insulation type/thickness - / mm polyurethane class A1/10Width mm 933Depth mm 700Height mm 2.130Weight kg 294 297 300 310

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions(3) Maximum outdoor temperature referred to indoor air temperature =24°C* Please contact Technical Sales Support

Hiline

HIGH PERFORMANCE AIR CONDITIONING

Hiline PI is the package direct expansion type, air con-ditioner range, with built-in air cooled condenser, forindoor installation, available in upflow and downflow ver-sion. Where there is minimum space, the compactnessof the Slim version solves this problem (3 and 4Kwmodels available in a 295/600/2000 W/D/H frame).

Faster Start-Up

The cooling circuit is pre-charged, fine tuned and fully testedbefore delivery. No pressure test is required on site. Installationis speeded up by using the fast-plug electrical connections (onrequest) and the automatic commissioning software: installa-tion and commissioning are completed in less than 25 minswithout need of specialized personnel on site.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Hiline can be powered by 48VDC emergency power sourcein case of mains failure. Continued ventilation and theoptional maximised freecooling assure constant operationof the telecommunications equipment and continued reve-nue from the site. 230/1/50 emergency supply is also avai-lable as an option.

High Versatility

Upflow or downflow air supply version, combined with theback or side condenser connections make Hiline suitable forthe most different sites configuration. Use the available fullrange of connection kit, to make your own installation true.

High Connectivity

The standard on board control allows teamwork with otherunits and connectivity to innovative Liebert-HIROSS super-vision system or to third-party monitoring. Connections canmake use of existing Ethernet LAN and new interactive solu-tions via Web are available.

General Features

Model Hiline PI 05 07 10 12 15Air supply Under (U)/Over (O)Main power supply 230 / 1N / 50 400 / 3N / 50Emergency power supply (opt) 48V DC or 230 / 1N / 50PerformancesTotal cooling capacity (1) U/O kW 5,2/5,2 7,5/7,4 10,8/10,8 12,9/13,1 16,5/16,1Sensible cooling capacity (1) U/O kW 5,2/5,2 6,9/7,1 10,8/10,8 12,9/13,1 15,3/15,7Compressor AC power input (1) U/O kW 0,96/0,96 2,14/2,17 2,81/2,88 3,53/3,50 4,52/4,52Condenser fan AC power input (@50Pa) (1) U/O kW 0,72/0,72 0,72/0,72 1,26/1,27 1,26/1,27 1,26/1,27Evaporator fan AC power input (1) U/O kW 0,46/0,54 0,49/0,61 0,93/0,94 1,04/1,03 1,12/1,11Evaporator fan DC power input (1) U/O kW 0,27 0,34 0,43 0,55 0,68Evaporator airflow m3/h 1.950/2.100 2.050/2.200 3.405/3.560 3.780/3.890 4.000/4.200U (ESP 20 Pa)/O (ESP 50 Pa)Condenser airflow 50Pa / 200 Pa m3/h 2.740/2.380 4.830/4.280Freecooling max.airflow U/O m3/h 1.500/1.890 1.570/1920 3.180/3.180 3.480/3.480 3.740/3.740Outdoor sound pressure level (2) dB(A) 60 60 62 62 62Indoor sound pressure level (2) dB(A) 55 57 55 56 57Max.ambient temperature (3) °C 45 45 45 45 45Refrigeration CircuitCompressor type/quantity scroll/1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity/type/poles AC version 1/radial/4Quantity/type/poles DC version 1/plug/- 2/plug/-Driven/motor protection direct/IP54Condenser FanQuantity/type/poles 1/radial/4Driven/motor protection direct/IP54Control system variable speedFilter type/efficiency (EN 779) pleated/G3Electric heating (opt) kW 3,0 4,5 6,0CabinetFrame galvanized steelPainting epoxydic powderInsulation type/thickness -/mm synthetic foam class 1/10Width mm 650 900Depth mm 650 750Height mm 1.990 2.050Weight Under / Over kg 228/232 231/236 287/292 287/292 297/302

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply.(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions.(3) Maximum outdoor temperature referred to indoor air temperature =24°C.

Hiline Displacement

HIGH PERFORMANCE AIR CONDITIONING

Hiline Displacement is the package indoor air conditio-ner with combined front and side low-level air delivery,of the direct expansion type, with built-in air cooled con-denser. It is especially designed for telecommunicationssites like BTS, Fibre Optic Networks and other techno-logical environments.

High Energy Efficiency: Displacement Advantages

The cooled air introduced into the room at low-level and at lowspeed brings to air stratification with an upper hotter area anda lower cooler area. The unit takes the air in from the upper hot-ter area resulting in higher efficiency of the air conditioner.There is no formation of overheated or overcooled areas. Thisguarantees the elimination of hot spots in the electronic equi-ment.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Hiline Displacement can be powered by 48VDC emergencypower source in case of mains failure. Continued ventilationand the optional maximised freecooling assure constantoperation of the telecommunications equipment and conti-nued revenue from the site. 230/1/50 emergency supply isalso available as an option.

Ease Of Installation

Cooled air is supplied at low-level, no raised floor is requi-red. The condensing section can be ducted on the rear or onthe side of the unit for easiest and most flexible installation.

Model Hiline PI D 05 07 10 12 15Air supply DisplacementMain power supply 230 / 1N / 50 400 / 3N / 50Emergency power supply (opt) 48V DC or 230 / 1N / 50PerformancesTotal cooling capacity (1) kW 5,1 7,4 11,8 13.4 16,1Sensible cooling capacity (1) kW 5,1 6,5 11,2 11.9 14,4Compressor AC power input (1) kW 1,1 2,0 2,7 3,5 4,2Condenser fan AC power input (@50Pa)(1) kW 0,6 0,6 1,2 1,2 1,2Evaporator fan AC power input (1) kW 0,4 0,4 0,8 0,8 0,9Evaporator fan DC power input (1) kW 0,43 0,43 * * *Evaporator airflow m3/h 1.800 1.800 2.800 2.800 3.250Condenser max.airflow 50/200 Pa m3/h 2.740/2.380 4.830/4.280Freecooling max.airflow m3/h 1.450 1.450 2.500 2.500 2.900Outdoor sound pressure level (2) dB(A) 61 62 63 63 63Indoor sound pressure level (2) dB(A) 55 55 55 55 57Max.ambient temperature (3) °C 45 45 45 45 45Refrigeration CircuitCompressor type/quantity scroll/1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity/type/poles AC version 1/plug/4Quantity/type/poles DC version 1/plug/- 2/plug/-Driven/motor protection direct/IP54Condenser FanQuantity/type/poles 1/plug/4Driven/motor protection direct/IP54Control system variable speedFilter type/efficiency (CEN EU) pleated/G3Electric heating (opt) kW 3,0 4,5 * * *CabinetFrame galvanized steelPainting polyester - RAL7035Insulation type/thickness -/mm polyurethane class A1/10Width mm 650 900Depth mm 650 750Height mm 1.990 2.300Weight kg 245 250 300 300 320

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply.(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions.(3) Maximum outdoor temperature referred to indoor air temperature =24°C.* Please contact Technical Sales Support

General Features

HISP

HIGH PERFORMANCE AIR CONDITIONING

Hisp air conditioners are the split solution for technolo-gical rooms and telecommunication sites: they arecomposed of an internal evaporating unit (SE, SplitEvaporator) and an external condensing section (SC,Split Condenser).

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Hisp can be powered by either 48VDC or 230/1/50 in caseof mains failure, ventilating and maximising freecooling tokeep the indoor temperature below the shut-down limit andguarantee continued operation of the telecommunicationequipment.

Full Installation Accessories Range

The unit can be supplied complete with all main accesso-ries for installation such as plate and flexible or rigid ductsfor freecooling connections, overpressure gravity damper,external rain proof grill for freecooling intake or to protectthe overpressure damper.

High Flexibility

The air conditioners may be installed either on a ceiling oron a wall, allowing maximum flexibility of use in the avai-lable space. The remote display allows flexibility in posi-tioning the control interface.

High Connectivity

The standard on board control allows teamwork with other unitsand connectivity to innovative Liebert-HIROSS supervisionsystem or to third-party monitoring. Connections can make useof existing Ethernet LAN and new interactive solutions via Webare available.

General Features

Model Hisp SE+SC 05 06 08 10 13 14Evaporating side installation Horizontal or verticalMain power supply 230 / 1N / 50 400 / 3N / 50Emergency power supply (opt.) 48V DC or 230 / 1N / 50PerformancesTotal cooling capacity (1) kW 4,8 5,8 8,5 10,9 13,7 15,2Sensible cooling capacity (1) kW 4,6 5,3 8,5 10,2 13,3 13,8Compressor AC power input (1) kW 1,21 1,62 1,77 2,63 3,48 4,52Condenser fan AC power input (1) kW 0,18 0,18 0,26 0,26 0,26 0,77Evaporator fan AC power input (1) kW 0,26 0,26 0,7 0,7 1,12 1,12Evaporator fan DC power input (1) kW 0,14 0,14 0,34 0,34 0,6 0,6Evaporator airflow m3/h 1.510 1.510 2.670 2.270 3.950 3.950Condenser max.airflow m3/h 2.390 2.390 3.800 3.800 3.800 5.320Freecooling max.airflow m3/h 1.400 1.400 2.230 2.230 3.600 3.600Outdoor sound pressure level (2) dB(A) 47 48 52 54 56 58Indoor sound pressure level (2) dB(A) 55 55 60 60 62 62Max.ambient temperature (3) °C 48 45 48 48 45 46Refrigeration CircuitCompressor type/quantity - scroll/1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity/type/poles AC version - 2/centrifugal/4Quantity/type/poles DC version 2/plug/-Driven/motor protection - direct/IP44Condenser FanQuantity/type/poles 1/axial/6 1/axial/4Driven/motor protection - direct/IP54Control system variable speedFilter type/efficiency (CEN-EU) pleated/G3Electric heating (opt.) kW 3,0 6,0CabinetFrame - galvanized steelPainting polyester - RAL7035Insulation type/thickness -/mm polyurethane class A1/10Evaporator (SE) Width mm 800 1.100Evaporator (SE) Depth/with freecooling mm 800/1.050 1.095/1.395Evaporator (SE) Height 310 395Evaporator (SE) Weight/with freecooling 54/62 110/122 120/132Condenser (SC) Width 800 1.050Condenser (SC) Depth 285 500Condenser (SC) Height mm 537 690Condenser (SC) Weight kg 49 51 112 115 124 125

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply.(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions.(3) Maximum outdoor temperature referred to indoor air temperature =24°C.

Cabinet Cooler is the indoor package air conditioner,direct expansion with built-in air cooled condenser espe-cially designed for telecommunications sites like BTS,Fibre Optic Networks and other technological environ-ments.

High Power Density Rate

More and more applications in modern telecommunicationsnetworks are based on small enclosures with an increasing need for reduced dimensions but with high data process inten-sity. Cabinet Cooler is the answer to the need of providing highrefrigerating power in a small environment with up to 6 kWcooling capacity and a 600x300x1600 mm (WxDxH) frame.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Evaporator fan, damper and control are powered by 48VDCemergency power sources in case of mains failure. Continuedventilation and the maximised freecooling assure constantoperation of the telecommunications equipment and conti-nued revenue from the site. The 48VDC supply increases thelifetime and reliability of the microprocessor and unit.

Ease And Flexibility Of Installation

A full range of air delivery directions is available: downflow,frontal, combined frontal and lateral, which makes the unitsuitable for several applications and positioning incontainers and cabinets . It can be mounted on slides, in therack, on the door and along the side wall.

Cabinet Cooler

HIGH PERFORMANCE AIR CONDITIONING

Dedicated Accessories

Mount the especially designed grille to optimise condensingairflow in the direct expansion mode. This prevents short cir-cuit in the free-cooling mode and any water intrusion.

General Features

Model Cabinet Cooler CC 03 05 06Air supply Frontal Downflow / Underflow / SideMain power supply 230 / 1N / 50Emergency power supply (standard) 48V DCPerformancesTotal cooling capacity (1) kW 3,86 4,86 5,74Sensible cooling capacity (1) kW 3,32 4,86 5,29Compressor AC power input (1) kW 1,32 1,88 2,63Condenser fan AC power input (1) kW 0,25 0,25 0,25Evaporator fan DC power input (1) kW 0,053 0,185 0,185Evaporator airflow m3/h 820 1.450 1.450Condenser max.airflow m3/h 1.600 1.600 1.600Freecooling max.airflow m3/h 700 1.270 1.270Outdoor sound pressure level (2) dB(A) 62 64 66Indoor sound pressure level (2) dB(A) 63,5 65,8 66,7Max.ambient temperature (3) °C 45 45 41Refrigeration CircuitCompressor type / Quantity scroll / 1Refrigerant R407CExpansion device thermostatic valveEvaporator FanQuantity / type / poles DC version 2/plug/-Driven direct Condenser FanQuantity / type / pole 2/plug/4 Driven / motor protection direct / IP44 Control system variable speedFilter type / efficiency (CEN-EU) G3Electric heating (opt) kW 1,5CabinetFrame galvanized steelPainting polyester - RAL7035Insulation type / thickness -/mm polyurethane class A1 / 10Width mm 600Depth mm 300Height mm 1.600Weight kg 122 124 125

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions(3) Maximum outdoor temperature referred to indoor air temperature =24°C

Mini Cooler

HIGH PERFORMANCE AIR CONDITIONING

Mini Cooler is the indoor package air conditioner,direct expansion with built-in air cooled condenserespecially designed for telecommunications sites incabinet and enclosure (e.g. BTS and other technologi-cal environments).

High Power Density Rate

More and more applications in modern telecommunicationsnetworks are based on small enclosures with an increasingneed for reduced dimensions but with high data process inten-sity. Mini Cooler is the answer to the need of providing highrefrigerating power in a small environment with up to 5 kWcooling capacity and a 310x620x1595 mm (WxDxH) frame.

Faster Start-Up

The cooling circuit is pre-charged, fine tuned and fully testedbefore delivery. No pressure test is required on site.Installation is speeded up by using the fast-plug electrical con-nections (on request) and the automatic commissioning soft-ware: installation and commissioning are completed in lessthan 25 mins without need of specialized personnel on site.

Energy Saving And Cost Effective Cooling

The most modern design and components such as scroll com-pressor, plug-type fans and the freecooling mode assure highenergy saving and greatly reduce running and lifetime cost.

High Reliability

Evaporator fan, damper and control are powered by 48VDCemergency power sources in case of mains failure. Continuedventilation and the maximised freecooling assure constantoperation of the telecommunications equipment and conti-nued revenue from the site. The 48VDC supply increases thelifetime and reliability of the microprocessor and unit.

Dedicated Accessories

Mount the especially designed plenum to optimise conden-sing airflow in the direct expansion mode and reduce thenoise level. It prevents any airflow short circuit in the free-cooling mode and any water intrusion.

General Features

Model Mini Cooler HCS4U HCS4UAir supply - downflowMain power supply 230 / 1N / 50Emergency power supply (standard) 48V DC PerformancesTotal cooling capacity (1) kW 4,8Sensible cooling capacity (1) kW 4,8Compressor AC power input (1) kW 1,6Condenser fan AC power input (1) kW 0,52 Evaporator fan DC power input (1) kW 0,136Evaporator airflow m3/h 1.100Condenser max. airflow m3/h 1.400Freecooling max. airflow m3/h 900Outdoor sound pressure level (2) dB(A) 57Max. ambient temperature (3) °C 40Refrigeration CircuitCompressor type / quantity Scroll/1Refrigerant R407/CExpansion device Thermostatic valveEvaporator FanQuantity / type / poles DC version 1/plug/-Driven / motor protection Direct/IP44Condenser FanQuantity / type / poles 2/plug/4Driven / motor protection Direct/IP44Control system Variable speedFilter type / efficiency (CEN-EU) Pleated/G3Electric heating (opt) kW 1,5CabinetFrame Galvanized steelPainting polyester - RAL7035Insulation type / Thickness -/mm polyurethane class A1/10Width mm 310Depth mm 620Height mm 1.595Weight kg 130

(1) Reference conditions are 27°C, &47% R.H indoor, 35°C outdoor; nominal power supply(2) Measured with outdoor temperature 35°C, 2 meters from the unit, free field conditions.(3) Maximum outdoor temperature referred to indoor air temperature =24°C

Hicab

HIGH PERFORMANCE AIR CONDITIONING

Hicab is the “active” cooling solutions for low heat loadsapplications in battery and power enclosures or smallBTS. It is suitable for door, or slide-in installation in outand indoor electronic enclosures & cabinets.

High Efficiency And Compact Design General Features

Cross Flow Internal Fan

Hermetic Compressor

Aluminium Alloy Structure

Backward Curved Blades External Fan

Model Hicab 120Total / sensible cooling capacity (1) W 1.200Power consumption (1) W 905Voltage supply V/Ph/Hz 230 / 1N / 50

Refrigerant R134aOutdoor temperature range °C -30/+50Outdoor noise @2m(Free Field) (1) dB(A) 65Dimensions (WxDxH) mm 466x160x1.030

(1) External temperature 35°C; return conditions 27°C/47% R.H.

Compact Air Conditioner

Hitherm

HIGH PERFORMANCE AIR CONDITIONING

Hitherm is the “passive” cooling solution for low heatloads applications in battery, power enclosures andsmall BTS. It is suitable for door, wall or slide-in installa-tion in out and indoor electronic enclosures & cabinets.

High Efficiency And Compact Design General Features

48 VDC Optional Power Supply

Aluminium Cross-Flow Core

Backward Curved Blades Fan

Modulating Speed Control “Outdoor” fan

Model Hitherm 100Cooling capacity (1) W 550Power consumption W 280Voltage supply V/Ph/Hz 230 / 1N / 50

Outdoor temperature range °C -30/+50Outdoor noise @2m(Free Field) dB(A) 65Dimensions (WxDxH) mm 465x149x1.033

(1) T indoor -T outdoor ambient = 5K

Air To Air Heat Exchanger

Liebert HIROSS: Your Partner For An Easier Network Roll-Out

Thermal Consulting

���������������� ����������������������������������������� ���������������������������������������

Quality

����� !"�# ���������������������������������������������������������$������������%�����������������

Training

&����������������������� ���������������������������������������������������������������$������������������������������������������������������'�������������������������������������������

Dedicated Key-account

% ���������������������������$����������������'�����������������������������

Flexible Production

����$�����������������������������������������������������������������������������������������������������������������������������������

Competitive Solution

(����)��������������'����������������������������������������������

Project Co-ordination

*���������������������������������������������������������������������

Worldwide Service

*���� ���������� ������������+��������������$����������,'�����������������������������$���������$�����������������������������������������'���

Liebert HIROSS SolutionsSeries Type Airflow Cooling Typical Application

Cooling Freecooling Emergency Heating Filtration

Operations

HilineDisplacement

&������������-���+.&��������.,

/���������+0�'�*���������0����,

5-151�2����������������������

Hisp ���������-���+.&��������������������������,

(���3�����4������

5-14�������������������

Hiwall TT �������+.&��������.,

5����' 5-211�2�����������������������

Hiwall TD �������+.&��������.,

/�'����' 6-141�2�����������������������

Hiline U/O &������������-���+.&��������.,

5���������

5-151�2����������������������

CabinetCooler

6���������������-����+.&��������������������������,

/�'����'�*������0����

3-61�2����������������������

MiniCooler

%���������6�����+.&��������������������������,

/�'����' 4.81�2����������������������

Hicab %�����������������������������������������������+.�������1�'����.&�,

*����� 1.26�������������������

Hitherm *����� 0.55*7������������� ������

Freecoling

%�����������������������������������������������+.�������1�'����.&�,

Supply Capacity (kW)

��������������������� �*�����������������������������������������������������������������������������

Your Partner For An Easier Network Roll-Out

Liebert HIROSS HeadquartersVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)- Italytel. +39 049 9719111 fax +39 049 5841257

www.liebert-hiross.com - [email protected]

High Performance Air ConditioningVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)tel. +39 049 9719111 fax +39 049 5841257

[email protected]

Uninterruptible Power Supply (UPS)Via Gioacchino Rossini, 6

20098 - San Giuliano Milanese (MI)tel. +39 02 98250 1 fax +39 02 98250337

[email protected]

Liebert HIROSS ServicesVia Leonardo da Vinci, 8

35028 - Piove di Sacco (PD)- Italytel. +39 049 9719111 fax +39 049 9719045

[email protected]

www.liebert-hiross.com

The Emerson logo is a trademark and a service mark of Emerson Electric Co.

Liebert HIROSS in Europe

Emerson Network Power GesmbH - AustriaHandelskai 102-112 - 1200 Wientel. +43 1 331890 fax +43 1 331892450

Emerson Network Power NV - BelgiumInterleuvenlaan 50B-3001 LEUVENtel. +32 16 380222 fax. +31 16 380227

Liebert HIROSS - Czech RepublicNa Pricce 72/6 – 14200 Praha 4tel. +42 02 41727954 fax +42 02 41718717

Emerson Network Power S.A. - France124 Avenue Gallieni - 93170 Bagnolettel. +33 1 43600177 fax +33 1 43607007

Emerson Network Power GmbH- GermanyLiebigstrasse 9 - 85551 Kirchheimtel. +49 89 9050070 fax +49 89 90500710

Emerson Network Power Kft. - Hungary1146 BudapestErzsébet királyné útja 1/ctel. + 36 1 273 3890 fax. +36 1 422 0621, +36 1 273 3897

Liebert HIROSS Italia S.r.L. - ItalyVia Gioacchino Rossini, 620098 - San Giuliano Milanese - Milanotel. +39 02 982501 fax +39 02 98250273

Emerson Network Power B.V. - NetherlandsRooseindsestraat 295705 BP HELMONDtel. +31 492 508520 fax. +31 492 508525

Emerson Network Power Sp z.o.o.- PolandUl. Konstruktorska, 11A - PL - 02-673 Warszawatel. +48 22 5485260 fax +48. 22 5485261

Emerson Network Power and Liebert HIROSS – RUSSIA, CISMalaya Trubetskaya Str. 8Korp. B, 11th floor - 119881 Moscowtel. +7 095 2329473 fax +7 095 2320358

Emerson Network Power SA- SpainEduardo Torroja, 23Poligono Ind. Leganes - 28914 Leganes - Madridtel. + 34 91 4957700 fax + 34 902 181936

Emerson Network Power AG - SwitzerlandRaeffelstrasse 29 - 8045 Zürichtel. +41 1 456 50 60 fax +41 1 456 50 70

Emerson Network Power Ltd – United KingdomFourth Avenue, Globe Park - MarlowBuckinghamshire - SL71YGtel. +44 1628 403200 fax +44 1628 403203

Addresses updates and further informationavailable in www.liebert-hiross.com - Contacts

Mob

ile P

rodu

ct G

uide

/103

692/

09-

004/

Cop

ista

mpa

/Prin

ted

in I

taly


Recommended