3
 Infrastructure Management and Monitoring for Business-Critical Continuity™  The L ieber t SN p rodu ct li ne of fers a wid e ran ge of sens ors for temperature, humidity and other readings. Liebert SN sensors are designed to assist in monitoring conditions within a rack and can be placed in any area to read temperature and humidity levels, and digital inputs. Sensor wiring connects to the Liebert RPC card, which enables monitoring through Liebert MPX or MPH rack PDU models. Integrated sensors are attached to a single cable and are available in these versions: one temperature probe; three temperature probes; and three temperature probes plus one humidity probe. These sensors may be placed in any area, including within a rack, to monitor temperature and humidity levels. Modular sensors are separate probes, each shipped with a 6.6 ft. (2m) cable for connection to a Liebert monitoring product. There are specic congurations to monitor digital inputs or temperature (1 probe each), or both temperature and humidity (2 probes). These sensors may be placed in any area within a rack to monitor temperature and humidity levels, and digital inputs such as a door switch, or smoke or water detectors. Liebert ®  SN   Sensors Monitoring For Business-Critical Continuity Flexibility  Auto-congur ation — no set-up required  May be co nnected in a string, which may include a combination of modular and integrated sensors. May be tool-lessly mounted on a Knurr rack frame, or may be mounted on a rack door, rack rail, or on at surfaces within the rack.  Availab ilit y  Connection to Liebert RPC allows monitoring through RPC-BDM Local Display Module, Secure Web/SNMP interface, or through Liebert Nform or Liebert SiteScan centralized monitoring software. Lowest Total Cost of Ownership  Integration with existing monitoring systems, and auto-conguration features, save time and money in installation and operation. Compatible Liebert Products Liebert SN integrated sensors are compatible with Liebert MPX and Liebert MPH Rack PDUs:  Liebert MPX™ — an Adaptive Rack PDU (power distribution unit) built with modular and scalable components that can be installed and recongured on-site to meet varying input and output power connectivity needs. The Liebert RPC™ (Rack PDU Card) is an optional accessory for the Liebert MPX, but is required for connecting the Liebert SN.  Liebert MPH™ — a single unit with xed capacity, input and output. The Liebert RPC is factory installed in the Liebert MPH. There are two types of Liebert SN sensors: Network Web Monitoring Liebert SiteScan Web Liebert MPX or MPH Liebert Nform Rack PDU Array (up to four systems) Liebert SN Sensors RPC-BDM (Local Display Module) Liebert RPC (Rack PDU Card) Liebert RPC (Rack PDU Card) Liebert MPX or MPH
Transcript
Page 1: Liebert SN Sensor Brochure; (R11-10); (SL-52400)

8/12/2019 Liebert SN Sensor Brochure; (R11-10); (SL-52400)

http://slidepdf.com/reader/full/liebert-sn-sensor-brochure-r11-10-sl-52400 1/2

™ 

Infrastructure Management and Monitorinfor Business-Critical Continuity™

 The Lieber t SN p roduct li ne of fers a wide range of sensors fortemperature, humidity and other readings. Liebert SN sensors aredesigned to assist in monitoring conditions within a rack and canbe placed in any area to read temperature and humidity levels, anddigital inputs.

Sensor wiring connects to the Liebert RPC card, which enablesmonitoring through Liebert MPX or MPH rack PDU models.

Integrated sensors are attached to a single cable and are available in these

versions: one temperature probe; three temperature probes; and threetemperature probes plus one humidity probe. These sensors may be placedin any area, including within a rack, to monitor temperature and humiditylevels.

Modular sensors are separate probes, each shipped with a 6.6 ft. (2m)cable for connection to a Liebert monitoring product. There are speciccongurations to monitor digital inputs or temperature (1 probe each), orboth temperature and humidity (2 probes). These sensors may be placedin any area within a rack to monitor temperature and humidity levels, anddigital inputs such as a door switch, or smoke or water detectors.

Liebert ® SN™  SensorsMonitoring For Business-Critical Continuity 

Flexibility

  Auto-congur ation — no set-uprequired

  May be connected in a string, whichmay include a combination of modularand integrated sensors.

May be tool-lessly mounted on a Knurrrack frame, or may be mounted on arack door, rack rail, or on at surfaces

within the rack.

 Availabilit y

  Connection to Liebert RPC allowsmonitoring through RPC-BDM LocalDisplay Module, Secure Web/SNMPinterface, or through Liebert Nformor Liebert SiteScan centralizedmonitoring software.

Lowest Total Cost of Ownership

  Integration with existing monitoringsystems, and auto-congurationfeatures, save time and money in

installation and operation.

Compatible Liebert Products

Liebert SN integrated sensors are compatible with Liebert MPX and Liebert

MPH Rack PDUs:  Liebert MPX™ — an Adaptive Rack PDU (power distribution unit) built with

modular and scalable components that can be installed and reconguredon-site to meet varying input and output power connectivity needs. TheLiebert RPC™ (Rack PDU Card) is an optional accessory for the Liebert MPX,but is required for connecting the Liebert SN.

  Liebert MPH™ — a single unit with xed capacity, input and output. TheLiebert RPC is factory installed in the Liebert MPH.

There are two types of Liebert SN sensors:

Network

WebMonitoring

LiebertSiteScan Web

LiebertMPX or MPH

Liebert Nform

Rack PDU Array(up to four systems)

LiebertSN Sensors

RPC-BDM(Local Display Module)

Liebert RPC(Rack PDU Card)

Liebert RPC(Rack PDU Card)

LiebertMPX or MPH

Page 2: Liebert SN Sensor Brochure; (R11-10); (SL-52400)

8/12/2019 Liebert SN Sensor Brochure; (R11-10); (SL-52400)

http://slidepdf.com/reader/full/liebert-sn-sensor-brochure-r11-10-sl-52400 2/2

™ 

Emerson Network Power. 

The global leader in enabling Business-Critical Continuity ™ .

EmersonNetworkPower.com

AC Power

Connectivity

DC Power

Embedded Computing

Embedded Power

Infrastructure Management & Monitoring

Outside Plant

Power Switching & Controls

Racks & Integrated Cabinets

Services

Precision Cooling Surge Protection

Emerson Network PowerLiebert Corporation

World Headquarters

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

United States Of America

800 877 9222 Phone (U.S. & Canada Only)

614 888 0246 Phone (Outside U.S.)

614 841 6022 FAX

Emerson Network Power

European Headquarters

Via Leonardo Da Vinci 8

Zona Industriale Tognana

35028 Piove Di Sacco (PD)

Italy

39 049 9719 111 Phone

39 049 5841 257 FAX

Emerson Network Power Asia Pacific

29/F, The Orient Square Building

F. Ortigas Jr. Road, Ortigas Center

Pasig City 1605

Philippines

+63 2 687 6615

+63 2 730 9572 FAX

liebert.com24 x 7 Tech Support

800 222 5877 Phone

614 841 6755 (outside U.S.)

While every precaution has been taken to ensure accuracyand completeness in this literature, Liebert Corporationassumes no responsibility, and disclaims all liability fordamages resulting from use of this information or for any

errors or omissions.

© 2010 Liebert Corporation. All rights reserved throughoutthe world. Specifications subject to change without notice. All names referred to are trademarks or registeredtrademarksof their respective owners. ® Liebert is a registered trademark of the LiebertCorporation.SL-52400 (R11/10) Printed in USA

Dimensions - W x D x H, in. (mm) 2 x 3/4 x 1-5/8 (51 x 19 x 41)

Weight, lb. (kg)

Net Weight 0.25 (0.11)Shipping Weight 0.44 (0.2)

Temperature (SN-T and SN-TH models), °F (°C)

Ambient Operating Environment 41 to 131 (5 to 55)

Temperature Sensor Range 41 to 131 (5 to 55)

Accuracy ±1.1 (±0.5)

Humidity (SN-TH models)

Humidity 10 to 95% RH (non-condensing)

Accuracy ±3.5% RH

Altitude, ft. (m) Up to 6,500 (2000)

Dry Contact Supports (SN-3C models) Non-powered contact rated for minimum of 5V, 1mA

Specifications — Integrated Sensors

Integrated Sensors

Specifications — Modular Sensors

  Up to ten Liebert SN Sensor “probes” may be connectedto an RPC-1000 — Inte grated and Modular sensors may

be used in combination. The number of probes varies bysensor type. The maximum stri ng length is 65.6 ft. (20m).

Liebert RPC Rack PDU Card

Dimensions - W x D x H, in. (mm) 2 x 3/4 x 1-5/8 (51 x 19 x 41)

Weight, lb. (kg)

Net Weight 0.25 (0.11)

Shipping Weight 0.44 (0.2)

Temperature (all models), °F (°C)Ambient Operating Environment 41 to 131 (5 to 55)

Temperature Sensor Range 41 to 131 (5 to 55)

Accuracy ±1.1 (±0.5)

Humidity (SN-Z03 models)

Humidity 10 to 95% RH (non-condensing)

Accuracy ±3.5% RH

Altitude, ft. (m) Up to 6,500 (2000)

Modular Sensors


Recommended