3
High End Commercial Lighting Lighting Strategies: Lower illumination levels for ambient lighting to enhance accent lighting. Track Lighting. LT1 - Line voltage Downlight Incadescent Ambient. LT2 - Low voltage Downlight Metal Halide Ambient. LT3 - Low Voltage Directional LED Accent. Lighting Levels: 15-40 fc ambient, 50-75 fc accent and task. LT1 LT3 LT2
Transcript
Page 1: Light evaluation

High End Commercial Lighting

Lighting Strategies: Lower illumination levels for ambient lighting to enhance accent lighting.

Track Lighting. LT1 - Line voltage Downlight Incadescent Ambient.LT2 - Low voltage Downlight Metal Halide Ambient.LT3 - Low Voltage Directional LED Accent.

Lighting Levels: 15-40 fc ambient, 50-75 fc accent and task.

LT1

LT3

LT2

Page 2: Light evaluation

Intermediate Retail Lighting

Lighting Strategies: Partially concealed accent light. Task light on displays, exposed and decora-tive ambient light.

Fixture Schedule:LT1 - Pendant LED AmbientLT2 - Directional LED TaskLT3 - Cove Fluorescent AccentLT4 - Wall Washers Metal Halide UplightLT5 - Recessed LED Ambient

Lighting Levels: 35-45 fc ambient, 75-100 fc accent and task.

LT1 LT2

LT3

LT4

LT5

Page 3: Light evaluation

Intermediate Hospitality Lighting

Lighting Strategies: Concealed ambient light. Decorative task lights. Directional accent light.Low Voltage Lighting Design.

Fixture Schedule:LT1 - Pendant LED TasksLT2 - Directional spots AccentLT3 - Linear Cold Cathod blue, yellow DecorativeLT4 - Surface mounted downlights.LT5 - Decorative blue LED ambientLT6 - Recessed uplights LED Ambient CoveLT7 - Wall Washer White Dowlights

Lighting Levels: 15-40 fc ambient, 35-50 fc accent and task.