s i l v e r l i n e g r o u p . c o . z a
Light Steel Frame Construction &High Performance Alternative Building Solutions
Building for a better tomorrow!
Winner
FRANCHISOR of the
YEAR 2014
COMPANY PROFILEThe Silverline Group ensures customer satisfaction and invites you to contact
us for all your property, construction and architectural requirements. Our team consists of experienced professionals who will serve their clients through excellence.
2
Engineering
STEEL
DETAILING
• ANCHOR BOLT PLANS
ERECTION FRAMING PLANS•
FRAMING PLANS•
SHOP DRAWINGS•
STAIRCASES AND HANDRAILS•
BILLS OF MATERIAL•
• STRUCTURAL STEEL DESIGNS
• REINFORCED CONCRETE DESIGN
DESIGN CALCULATIONS•
REINFORCED CONCRETE DETAILING•
SLABS, COLUMNS, BEAMS•
PILE CAPS•
STAIRCASES•
FOUNDATIONS•
RETAINING WALLS•
REINFORCED
CONCRETE
• CFS DESIGNS
CFS STRUCTURAL DRAWINGS•
CFS MACHINE DRAWINGS •
(CNC DRAWINGS)
BILL OF MATERIALS•
3D MODELS•
SHEET METAL DEVELOPMENTS•
COLD FORMED
STEEL
Head OfficeCape TownSouth Africa
Light Steel Frame Construction Franchises
Operations Proprietary Services
Light Steel Frame
Franchises
National
Cross Border
International
Research & Development
Marketing Division
Distribution
Imports
Exports
Franchise Training Academy
Architecture Services
Engineering Services
Project Management
Costing Programs
Real Estate
Commercial
Residential
Industrial
Developments
Trusses
Engineering with ExcellenceEngineering with Excellence
Engineering for a better tomorrow!
Engineering
Supplier Base
AGRICULTURAL, COMMERCIAL, RESIDENTIAL, INDUSTRIAL & INSTITUTIONAL can be built in half the time
Stronger than Brick & Mortar •
Up to 50% faster than Brick & Mortar •
More than 100% better insulated than Brick & Mortar•
Factory precision•
50 year Material Warranty•
600 year Durability•
Approved by All Banks, Municipalities, SABS, Government •
2% Waste Material on site•
80% less Carbon Footprint•
COMMERCIAL BUILDING ADVANTAGES
Earlier occupation for your customers – thus earning additional income on rental •
4% more lettable rental area – due to internal space increase internal & external walls•
Reduces columns internal & external •
Saving on Ring beams•
Saving on Floors costs•
Reduces Foundation requirements due to 10 times lighter structure on the foundation- –
Roof structure weight savings •
Superior insulation properties saving on capital outlay of H.A.V up to 40% of electricity bill• –
Plumbing & Electrical installation easier and faster •
Reduces interest period on Bond accounts due to early occupation•
2 Hour Fire Walls Superior option with LSF vs traditional methods • –
Reduces Base plate sizes•
Reduces foundation footings•
Better sound properties than brick & mortar•
All structures signed off by a Structural Engineer
3
BENEFITS OF LIGHT STEEL FRAME
4
COMMERCIAL
5
COMMERCIAL
COMMERCIAL
6
RESIDENTIAL
7
RESIDENTIAL
8
RESIDENTIAL
9
RESIDENTIAL
10
Light Steel Frame panels Cladding fiber cement boards Plumbing
Cladding fiber cement boards Bracing Mobile solid wall machine
Filling in walls
Filling in walls Complete walls
Solid wall machine mixer Mixing light-weight concrete
Complete walls
Finished ProductCompleted interior Finished Product
SOLID WALL SYSTEM
11
12
SILVER FAÇADE
Eco Friendly Foundations• • • NO CRACKS OR STRUCTURAL FAILURES REDUCES STEEL STRESS GREEN PRODUCT THE LOAD IS DISTRIBUTED UNIFORMLY AND REMAINS UNDER BREAKING LIMIT• REDUCING CONSIDERABLY CONCRETE CONSUMPTION AND INSTALLATION TIME• VENTILATION ON MOISTURE RISING SINGLE POUR OF SLAB AND FOUNDATION BEAMS• • THERMAL INSULATION EASIER MAINTENANCE ON PLUMBING AND ELECTRICAL SYSTEMS • • R VALUE 0.5 STRONGER THAN CONVENTIONAL • •
TRUSSES
WAREHOUSES / INTERNAL WALLS
13
EXTERIOR
15
EXTERIOR
14
INTERIOR
16
COMMERCIAL EXTERIOR / SILVER PANEL
17
CONCEPTS
18
19
According to National Building Regulations 10400 XA efficiency Act,
implemented 11 Nov 2011 the minimum requirement R-Value for
construction walls is 0.35
Internal wall Details2 HOUR FIRE RATING
Standard Double Brick wall“R” Value: 0.26
Standard Single Brick wall“R” Value: 0.18
Internal wall Details1 HOUR FIRE RATINGOverall Thickness: 130mm‘R’ Value: 2.9Fire rating: 60 mins SABS ApprovedSound Insulation 51dB
Silver Facade LFS Wall DetailOverall Thickness: 160mm‘R’ Value: 5.3Fire rating: 60 mins SABS ApprovedSound Insulation 52dB
Handy Plank Wall Detail Overall Thickness: 130mm‘R’ Value: 2.8Fire rating: 60 mins SABS ApprovedSound Insulation 46 dB
Solid Wall DetailsOverall Thickness: 110mm‘R’ Value: 1.1Fire rating:120 mins SABS ApprovedSound Insulation 46 dB
Etics Wall DetailsOverall Thickness: 180mm‘R’ Value: 3.76Fire rating: 60 mins SABS ApprovedSound Insulation 52 dB
Standard LFS Wall DetailsOverall Thickness: 133mm‘R’ Value: 2.8Fire rating: 60 mins SABS ApprovedSound Insulation 52 dB
Silver FaÇade 3D
EXTERIOR WALLS
INTERIOR WALLS
Express Joint System - (Silver Panel)Overall Thickness: 133mm‘R’ Value: 2.8Fire rating: 60 mins SABS ApprovedSound Insulation 52 dB
With 2 boards on both sidesOverall Thickness: 160mm‘R’ Value: 3.07Fire rating: 120 mins SABS ApprovedSound Insulation 53dB
8
45 DECIBEL (dB)30 MINUTES FIRE RATING
49 DECIBEL (dB)60 MINUTES FIRE RATING
Franchise opportunities available: Country Wide, Cross Border
International Master Franchises
s i l v e r l i n e g r o u p . c o . z a