+ All Categories
Home > Documents > Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”....

Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”....

Date post: 12-Aug-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
20
lindab rainline | technical information roof drainage system Lindab Roof Drainage System Technical Information Lindab Rainline TM
Transcript
Page 1: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

l indab rainl ine | technical information roof drainage system

Lindab Roof Drainage SystemTechnical Information

Lindab Rainline TM

Page 2: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

l indab rainl ine | roof drainage system

SRÖR 120

SRÖR 111

SRÖR 100

SRÖR 87

SRÖR 75

0.5 0.6 0.7 0.8 0.9 1.0

0.5 0.6 0.7 0.8 0.9 1.0

L1L2+L1

=

R 1

50R

125

R 1

00R

ER

136

RoofareaAv m2

0.5 0.6 0.7 0.8 0.9 1.0

0.5 0.6 0.7 0.8 0.9 1.0

L1L2+L1

=

580 Av

560

540

520

500

480

460

440

420

400

380

360

340

320

300

280

260

240

220

200

180

160

140

120

100

80

60

Av 820

800

780

760

740

720

700

680

660

640

620

600

580

560

540

520

500

480

460

440

420

400

380

360

340

320

300

280

260

240

220

200

180

160

140

120

100

34032030028026024022020018016014012010080604020

240

220

200

180

160

140

120

100

80

60

40

20

360380

260

280

300

320

400420440460480500

R 1

90

2

Dimensioning

Roof drainage

Dimensioning can be done according to Swedish Standard SS or the Advice and instructions for the code of practice, “Hus AMA, RA 08 Hus”.

Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This

is because RA 08 Hus has given some consideration to the tendency of gutters to fill up with sludge from leaves and loose material on roof cladding etc. SS compensates this by specifying a small-est fall for self-clearance of 5-7 mm/m,

depending on dimensions. Diagrams and tables based on the dimensioning instructions in SS and Hus AMA are in-cluded below.

SS diagrams contain curves for various rain intensities. It approves the assumption that the probable rain intensity can be specified as 0.013 l/(sm2) on areas less than 10,000 m2 for the whole country, which is what our di-agram is based on. SS assumes that the gutter is laid with a smallest fall of 2.5 mm/m. Since SS does not cover our en-tire product range, the curves in SS have been extrapolated. It should be noted that the dimen sioning instructions in SS can give a relationship between gutters and down pipes which does not corre-spond with the product standard for nozzles. This is because of traditional and appearance demands for size matching between gutters and down pipes.

Dimensioning to SS

Av = True roof areaL1 and L2 = Distance from building corner

ExampleRoof area L = 20 m, B = 9 m → Av = 180 m2

A down pipe located 11.6 m from one end

ResultYou can choose a half round gutter of R125or larger.The down pipe from the second diagramshould then be SRÖR75.

L1 =

11.6 = 0.58

L1 + L2 20

SRÖR 120

SRÖR 111

SRÖR 100

SRÖR 87

SRÖR 75

0.5 0.6 0.7 0.8 0.9 1.0

0.5 0.6 0.7 0.8 0.9 1.0

L1L2+L1

=

R 15

0R

125

R 10

0RE

R 13

6

TakareaAv m

2

0.5 0.6 0.7 0.8 0.9 1.0

0.5 0.6 0.7 0.8 0.9 1.0

L1L2+L1

=

580 Av

560

540

520

500

480

460

440

420

400

380

360

340

320

300

280

260

240

220

200

180

160

140

120

100

80

60

Av 820

800

780

760

740

720

700

680

660

640

620

600

580

560

540

520

500

480

460

440

420

400

380

360

340

320

300

280

260240

220

200

180

160

140

120

100

34032030028026024022020018016014012010080604020

240

220

200

180

160

140

120

100

80

60

40

20

360380

260

280

300

320

400420440460480500

R 19

0

L1 + L2 20

Page 3: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

3

l indab rainl ine | roof drainage system

Number Name Nearest NCS Nearest RAL

001 Antique white S 1002-G50Y 9002

015 Black S 9000-N 9005

044 Antracite metallic S 6000-N 9007

045 Silver metallic - 9006

087 Dark grey S 7005-B20G 7011

434 Brown S 8005-Y80R 8017

742 Tile red S 4040-Y80R 8004

758 Dark red S 5040-Y80R 3009

778 Copper metallic S 4030-Y60R 8003

830 Pine green S 7010-G30Y 6020

Technical Facts

Rainline

Colour chart

Other material

– Aluminium-zinc – –

Page 4: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

4

l indab rainl ine | roof drainage system

Technical Facts

Gutter with accessories

RSK Gutter joint

Dim

100

125

150

R Gutter

Dim D d Area* Area** mm mm mm2 mm2

100 107 17 4500 4100

125 123 17 5900 5500

150 155 17 9400 8900

190 192 22 17300 16200

*Sectional area **Water carrying area (6 mm lower front edge,190 gutter 11mm)

D

d

SSK Adjustable snap bracket

Dim

100

125

150

To SS-EN 1462 Class A-H

26

Ø5,5

STAG Stay strap

292

201.25

Ø4

Ø4

Page 5: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

5

l indab rainl ine | roof drainage system

Technical Facts

Gutter with accessories

5/6

Ø5,5

25/30

L

K33/K24/K21/K16/K07 Bracket

Dim L mm K33 K24 K21 K16 K07

100 160 70

125 210 160 70

150 210 160 70

190 334 244

To SS-EN 1462 Class A-H

5 25

L

Ø5,5

KFL35/KFL/KFM Bracket

Dim L mm KFL35 KFL KFM

100 196

125 336 196 146

150 336 196 146

To SS-EN 1462 Class A-H

K11 Bracket for 27° roof pitch

Dim

100

125

150

To SS-EN 1462 Class A-H

5

25

Ø5,5

60

40

27

KFK Fascia Bracket

Dim

100

125

150

To SS-EN 1462 Class A-H

5

25

Ø5,5

Page 6: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

6

l indab rainl ine | roof drainage system

Technical Facts

Gutter with accessories

KBO Bracket bender

TB Cover brace

Dim

100

125

150

A

A 29

Ø4 5

A-A

OMV Gutter outlet

Dim A HD/d mm mm

100/75 156 56

100/87 156 48

125/75 174 67

125/87 174 59

125/100 174 50

150/87 212 82

150/100 212 73

150/111 212 66

150/120 212 60

190/100 180 62

190/120 206 62

Page 7: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

7

l indab rainl ine | roof drainage system

Technical Facts

Gutter with accessories

RVY Gutter angle, outer

L

L

Dim L mm

100 295

125 175

150 245

190 285

RVI Gutter angle, inner L

L

Dim L mm

100 400

125 300

150 300

190 500

RGV/RGH Stop end

Dim

100

125

150

190

37

RG Stop end

Dim

125

150

Page 8: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

8

l indab rainl ine | roof drainage system

Technical Facts

Gutter with accessories

ÖSK Overflow protection

A

170

170

A

85

A-A

ÖSKR Overflow protection, straight

Dim

125

150

A A

340

85

A-A

RVI135 Gutter angle 135°, inner

Dim L mm

100 300

125 300

150 300

L

L

135°

RVY135 Gutter angle 135°, outer

Dim L mm

100 250

125 240

150 230 L

L

135°

Page 9: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

9

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

BUTKF Reinforced drain shoe

Material: Extruded aluminium.

Ø1253035

Ø90

2000

2,2

UTKF Reinforced shoe

Material: Extruded aluminium.

Ø1252,2

2000

SVHÅF Reinforced pipe holder

The holder is reversible for different wall spacings.

48

100

28

SRÖR Down pipe

Dim AreaDi/d mm2

75 4400

87 5900

100 7800

111 9700

120 11300

To SS-EN 612 Class A–X

A-A50

Di

A A

d

Page 10: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

10

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

BK70 Bends 70°

Dim Di/d

75

87

100

111

120

* Not BM. Will be replaced by 70 degrees bends, radius 110 mm.

Di

50

50

R110

70°

d

SOKN One piece bend

Dim D/d

75

87

100

185

5050

100 d

D

BM70 Bends 70°

Dim D/d

75

87

100

111

120

* Not BM. Will be replaced by 70 degrees bends, radius 110 mm.

d

50

R 110

70°

50

D

MST Intermediate pipe

Cuts into suitable pieces.

Dim

75

87

100

111

12050

1000

50d

Di

Page 11: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

11

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

SRORM Pipe connector

DimD/d

75

87

100

D

4060

dSRORM fits both inside and outside the downpipe.

SSVH Pipe holder

DimD

75

87

100

111

120

With wedge locking in aluminium-zinc design.

30

D9080

SSV Pipe holder for spike

DimD

75

87

100

111

120

With wedge locking in aluminium-zinc design and fixed spine.

80

D

SST Spike

Lmm

125

175

250

300

93

L 24

Page 12: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

12

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

GRÖR Adjustable branch

Dim

75

87

100

D

D

54

230

5050

d

VATK Hopper

Dim h

87 270

100 253

111 239

120 227

285

h50

Ø4

d

FRK Gutter hook1

124

65,5195,5

4

80°

Ø5,5

25

SLAS

Connector for 80 mm hose.

Dim

87

100

95

40

79

Page 13: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

13

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

UTK Shoe

Dim L mm

75 151

87 157

100 113

111 169

120 173

L

D

50

R 110

BUTK Drain shoe

Dim D1 D2 mm mm

75 81 115

87 93 115

100 93 115

111 93 119

D D

255 22

5

45

D1D2

D1D2

4035

DVSIL Leaf filter

Stainless steel.

3519

0

Ø95

PRT Sliding pipe

Dim

75

87

100

111

The sliding pipe fits outside the down pipe.

260

D

L

Page 14: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

14

l indab rainl ine | roof drainage system

Technical Facts

Down Pipe with accessories

RT Drain trap (HD polythene)

Leaf filter in HD polythene for down pipes. The lower section fits standard ground pipes/junction pipes.

101

Ø98-10335

110

SLS Self cleaning leaf trap

Self cleaning leaf filter in HD polythene for down pipes. The lower section fits standard ground pipes.

Ø98-103

293

35

MRT Drain connector

Connector for HD polythene filters. For connection to ground pipes with dimensions other than standard.

105

Ø101

Ø96

Ø79

FUTK Adjustable shoe

Dim

75

87

100

D

250

5050

d

Page 15: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

15

l indab rainl ine | roof drainage system

Technical Facts

Rectangular Gutter with accessories

RER Gutter

Dim Area* mm2

136 11000

* Water carrying area.

136

101

11090

RERGH/RERGV Stop end

Dim

136

A

A 45

A-A

RERSK Gutter joint

Dim

136

5 25

Ø5,5

L

REK07/REK21 Bracket

Dim L mm REK07 REK21

136 70 210

Page 16: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

16

l indab rainl ine | roof drainage system

Technical Facts

Rectangular Gutter with accessories

REOK Nozzle

Dim HD/d mm

136/87 95

136/100 85

136/111 75

D 165

d

H50

RERVI Gutter angle, inner

Dim L mm

136 300

L

L

RERVY Gutter angle, outer

Dim L mm

136 165

L

L

Page 17: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

17

l indab rainl ine | roof drainage system

Technical Facts

Accessories

STIFT Touch up paint with applicator brush

Page 18: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

Notes

Page 19: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

Notes

Page 20: Lindab Roof Drainage System Technical Information info.pdf · “Hus AMA, RA 08 Hus”. Dimensioning to SS gives smaller di-mensions than if RA 08 Hus is used. This is because RA

l indab rainl ine | technical information roof drainage system

Lindab Building Components is a business area within

the Lindab Group that develops, manufactures and

markets efficient, economical and aesthetic steel and

sheet metal solutions for the building industry.

We offer a wide range of components and systems

for all types of housing, as well as commercial and

industrial buildings.

Lindab Building Components is represented in over

30 countries throughout Europe. Our head office is in

Förslöv, in the south of Sweden.

SE-269 82 BåstadPhone +46 (0)431 850 00www.lindab.com

Lindab Profile

Art

no

. 153

103

2012

-01-

17


Recommended