www.stressline.ltd.uk
LINTEL GUIDE 2011
Click here to go straight
to the contents page…
bUiLD
On
OU
r sTrenG
TH
cOmPAnY HisTOrY
Stressline Limited manufactures a wide range of structural building products for domestic and commercial sectors. Stressline is the fi rst choice for builders, contractors & specifi ers across the UK because of its ability to deliver high quality products on time and at the right price, ensuring projects are not disrupted and work is completed on time.
Stressline also supply direct to site or through a supply chain of merchants across the country, making sure their products are always highly accessible. Stressline’s customers choose them over other structural product manufacturers because of the promise to always be competitive on price, the mixed order delivery capabilities and the high quality service.
Stressline’s in-house technical and manufacturing departments have worked hard over the last 12 months to deliver an extended range of steel lintels. The new lintel guide clearly lays out the extended standard range of steel lintels, and for the fi rst time the prestressed concrete lintel range, allowing the customer the utmost fl exibility and choice to satisfy their lintel requirements.
This extended steel lintel range perfectly compliments our other structural building products.
We manufacture a complete range of prestressed concrete products in addition to the prestressed concrete lintels; including fl ooring beams (suitable for concrete or insulation infi ll), hollowcore fl ooring, and walling panels. Precast items available include padstones, stairfl ights and landing slabs, although our extensive design and manufacturing resource enables special projects to be produced cost effectively. Our non structural range of products includes fencing and landscape walling products.
bUiLD On OUr sTrenGTH
inTrODUcinG OUr eXTenDeD LinTeL rAnGe
sTrUcTUrAL bUiLDinG PrODUcTs
2
cO
nTen
Ts
cAviTY WALL: sTAnDArD LeAF LinTeLs 5 - 10
service DeLiverY 4
cAviTY WALL: WiDe inner LeAF LinTeLs 11 - 16
cAviTY WALL: WiDe OUTer LeAF LinTeLs 17 - 22
rOLLeD sTeeL secTiOns LinTeLs 23 - 25
cLOseD eAves LinTeLs 26 - 28
Timber FrAme LinTeLs 29 - 30
sinGLe LeAF eXTernAL sOLiD WALL LinTeLs 31 - 32
inTernAL sOLiD WALL LinTeLs 33 - 34
eXTernAL sOLiD WALL LinTeLs 35 - 36
PresTresseD cOncreTe LinTeLs 37 - 39
ArcH FOrmers 40
sPeciALs 41 - 43
PADsTOnes 44
OTHer sTressLine PrODUcTs 45
TecHnicAL 46 - 47
240
213
50 44 98
150
98 47
‘h’ n
omin
al
95
‘h’ n
omin
al
200
‘h’ n
omin
al
200
‘h’ n
omin
al
220
100
cOnTenTs
%
98 94 98
‘h’ n
omin
al
1359498
‘h’ n
omin
al
135 94 98
‘h’ n
omin
al
33
Click on the tabs on this
page to be taken through to the relevant
sections
servic
e DeLiv
erY
service DeLiverY OUR COMMITMENT TO YOUsALes & sUPPOrTOur area sales managers and sales technicians are able to assist you with your specification needs. Whether advice is needed for a single lintel, or a comprehensive take off and pricing schedule for a multi dwelling development, our team is here to help.
The brochure and website outline our ranges and offer tools to assist your selection.
In addition, our unique ability to manufacture a range of structural building components offers the specifier and the buyer a complete solution for structural flooring (both beam and hollowcore), steel and concrete lintels and structural precast products, including padstones, staircases and landings.
Our flexible design and manufacturing facilities enable your “special” lintel requirements to be produced quickly and efficiently.
OUr PrODUcTsOur comprehensive range of standard steel and concrete lintels offers design capability for all circumstances, designed to the relevant BS EN standards and with the reassurance of BS EN ISO: 9001 (2008) management standard.
The cavity lintel range is supplied with captive insulation to ensure that it is not displaced. The fabricated range is manufactured with a proven non-welded method creating a secure connection that has not compromised the galvanised protection.
Our range of prestressed concrete lintels is manufactured using machinery and processes designed by our own engineers. This has enabled the maximum strength to section available, whilst producing high volumes of consistent quality products.
DeLiverYAll our products are delivered on flat bed articulated or rigid lorries, with the option of either self offload or crane offload. Depending on the customer’s requirements both steel and concrete lintels are packaged in stock packs or in consignment loads (with the option of house plots and locations marked on the product).
As we are located centrally we are able to supply all our standard products nationally, with delivery typically three to eight working days.
OUr PrOmiseStressline understand the day-to-day challenges you face on a building site and the importance of working with a supplier you can trust. Our promise is simple – to deliver competitively priced products, on time, to the required specification.
AccreDiTATiOnsStressline has an on-going commitment to improving both product and management systems; • 1989: BSI Quality Assurance Accreditation
to ISO 9001• 2003: BS EN ISO 9001:2000 • 2009: ISO 9001:2008
envirOnmenTAL AnD sUsTAinAbiLiTY We recognise our responsibilities to the environment. We are committed to developing, implementing and reviewing our management and operational policies and procedures to minimise our environmental impact. Our IMS includes all our compliance policies and achievement targets.
From our ongoing environmental and sustainability commitments we have continued to achieve significant reductions in our impact as manufacturers and distributors. One major environmental benefit shared with our existing customers is the ability to source our complete range of products and for them to be delivered as a mixed load on one vehicle, instead of separate deliveries which creates wasteful and unnecessary movements.
4bAcK… to ‘Contents’ page
sTAn
DA
rD LeA
F
APPLicATiOnstandard and Heavy Duty (HD)Designed to support:• Masonry loads• Masonry loads and uniformly distributed timber
fl oor loads• Uniformly distributed roof loads (in most cases
HD lintel type is required)
extra Heavy Duty (XHD) and composite extra Heavy Duty (cXHD) Designed to support:• Concrete fl oor loads• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTes See page 46 for general installation notes.
Additional requirements for composite extra Heavy Duty (cXHD) lintels• Ensure that the inner leaf channel is fi lled with
well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner fl ange of the lintel.
• Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured.
ADvAnTAGes• Easy to install and suitable for a variety of
applications• Galvanised coating ensures durability/longevity• Built-in plaster key: perforated base plate to
inner fl ange• Excellent thermal effi ciency of up to 0.32 W/mK • Built-in continuous insulation
% if in doubt please contact our technical department on
0870 7503167
cAviTY WALL STANDARD LEAF
5bAcK… to ‘Contents’ page
cA
viTY
50
sL50
sL50 HD
sL50 cXHD 150
sL50 cXHD 225
98
‘h’ n
omin
al
44 98
98 44 98
‘h’ n
omin
al
98 44 98
150
98 44 98
230
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
sL50 XHD 150
sL50 XHD 225
150
984498
225
98 44 98
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
6001200
95 113 134 140 153 185 190 190 215
5.0 5.4 7.4 7.6 8.0 9.0 9.2 13.6 17.8
16 17 22 23 24 28 28 28 28
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
12 13 17 18 19 22 22 22 22
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
2.2
6001800
236
19.6
89
75
21.5
2.9 4.5 5.6 6.8 9.0 10.0 13.3 16.2
13501500
236
19.6
71
60
21.5
19503000
16501800
6001800
156
16.3
72
61
12.6
156
16.3
62
52
12.6
19502100
156
16.3
53
45
12.6
22502400
236
19.6
55
46
21.5
31503900
19502100
236
19.6
37
35
20.5
4050 4800
22502400
6001200
140 153 190 190 215 215
7.6 8.0 9.2 13.6 14.9 17.8
42 40 41 41 33 33
33 31 32 32 26 26
5.6 6.8 10.0 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
25502700
28503000
31503900
4050 4800
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
6002100
225
26.7
79
66
20.6
225
26.7
60
51
20.6
22502700
6001650
150
21.5
55
46
11.1
150
21.5
43
36
11.1
18002100
150
21.5
32
27
11.1
22502700
225
26.7
49
41
20.6
28503300
225
26.7
41
34
20.6
34503900
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
See installation notes page 5
See installation notes page 5
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
bAcK… to ‘Contents’ page6
bAcK… to ‘Contents’ page
cA
viTY
70sL70
98 64 98
‘h’ n
omin
al
98 64 98
‘h’ n
omin
al
98 64 98
150
98 64 98
230
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
sL70 HD
sL70 cXHD 225
sL70 cXHD 150
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98
150
6498
98 64 98
225
sL70 XHD 225
sL70 XHD 150
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
6001200
95 113 134 140 153 185 190 190 207
5.2 5.6 7.7 7.9 8.3 9.3 9.5 14.1 17.9
16 17 22 23 24 28 28 28 28
12 13 17 18 19 22 22 22 22
2.2 2.9 4.5 5.6 6.8 9.0 10.0 13.3 16.2
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4800
236 236 236 236
19.6 19.6 19.6 19.6
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
6001800
19503000
31503900
4050 4800
156 156 156
16.3 16.3 16.3
72 62 53
61
12.6
52
12.6
45
12.6
6001800
19502100
22502400
225 225 225 225
26.7
66
26.7
51
26.7
41
26.7
34
79
20.6
60
20.6
49
20.6
41
20.6
6002100
22502700
28503300
34503900
150 150 150
21.5 21.5 21.5
55 43 32
46
11.1
36
11.1
27
11.1
6001650
18002100
22502700
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 19:1 (kN)
SWL 5:1 (kN)
RM (kNm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)See installation notes page 5
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
See installation notes page 5
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
140 153 190 190 207 207
7.9 8.3 9.5 14.1 14.9 17.9
42 40 41 41 33 33
33 31 32 32 26 26
5.6 6.8 10.0 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
7bAcK… to ‘Contents’ page
cA
viTY
100
6001200
95 113 134 140 153 185 190 190 225
5.3 5.7 7.9 8.10 8.5 9.5 9.6 14.3 19.6
16 17 22 23 24 28 28 28 28
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
12 13 17 18 19 22 22 22 22
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
RM (kNm)
SWL 19:1 (kN)
2.2 2.9 4.5 5.6 6.8 9.0 10.0 13.3 16.2
13501500
16501800
6001800
156 156 156
17.0 17.0 17.0
72 62 53
61
12.6
52
12.6
45
12.6
19502100
22502400
19502100
6001800
236 236 236 236
20.5 20.5 20.5 20.5
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
19503000
31503900
4050 4800
22502400
6001200
140 153 190 190 225 225
8.1 8.5 9.6 14.3 16.1 19.6
42 40 41 41 33 33
33 31 32 32 26 26
5.6 6.8 10.0 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
25502700
28503000
31503900
4050 4800sL100
sL100 HD
sL100 cXHD 150
sL100 cXHD 225
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
Not suitable to support precast concretefl oors, attic trusses, heavy point loads.
Not suitable to support precast concretefl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98 94 98
‘h’ n
omin
al
98 94 98
‘h’ n
omin
al
98 94 98
150
98 94 98
230
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
6001650
150 150 150
22.3 22.3 22.3
55 43 32
46 36 27
11.1 11.1 11.1
18002100
22502700
6002100
225 225 225 225
27.6 27.6 27.6 27.6
79 60 49 41
66 51 41 34
20.6 20.6 20.6 20.6
22502700
28503300
34503900
sL100 XHD 150
sL100 XHD 225
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98
150
9498
98 94 98
225
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
See installation notes page 5
See installation notes page 5
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
8bAcK… to ‘Contents’ page
98 114 98
‘h’ n
omin
al
98 114 98
‘h’ n
omin
al
98 114 98
150
98 114
230
98
cA
viTY
120100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
sL120 HD
sL120 cXHD 225
sL120 cXHD 150
98114
150
98
98 114
225
98
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
sL120 XHD 225
sL120 XHD 150
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
sL120sTAnDArD LenGTHs (mm) 6001200
Nominal Height “h” (mm) 95 113 134 153 185 185 190 190 205
Weights (kg/m) 5.6 6.0 8.2 8.8 9.8 9.8 10.0 14.8 19.7
SWL 1:1/3:1 (kN) 16 17 22 27 31 28 28 28 28
SWL 19:1 (kN) 12 13 17 21 25 22 22 22 22
RM (kNm) 2.2 2.9 4.5 6.8 9.0 9.0 10.0 13.3 16.2
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4800
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
SWL 19:1 (kN)
RM (kNm)
236 236 236 236
21.5 21.5 21.5 21.5
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
6001800
19503000
31503900
4050 4800
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
156 156 156
18.1 18.1 18.1
72 62 53
61
12.6
52
12.6
45
12.6
6001800
19502100
22502400
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 19:1 (kN)
SWL 5:1 (kN)
RM (kNm)
225 225 225 225
28.6
66
28.6
51
28.6
41
28.6
34
79
20.6
60
20.6
49
20.6
41
20.6
6002100
22502700
28503300
34503900
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
150 150 150
23.3 23.3 23.3
55 43 32
46
11.1
36
11.1
27
11.1
6001650
18002100
22502700
See installation notes page 5
See installation notes page 5
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
140 153 190 190 205 205
8.4 8.8 10.0 14.8 15.5 19.7
42 40 41 41 33 33
33 31 32 32 26 26
5.6 6.8 10.0 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
9bAcK… to ‘Contents’ page
cA
viTY
150
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95 113 134 153 185 185 190 190 215
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
5.8 6.3 8.5 9.0 10.0 10.0 10.2 15.2 21.2
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
16 17 22 27 31 28 28 28 28
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
12 13 17 21 25 22 22 22 22
RM (kNm)
RM (kNm)
RM (kNm)
2.2 2.9 4.5 6.8 9.0 9.0 10.0 13.3 16.2
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4800
sL150 HD
sL150
sL150 cXHD 150
sL150 cXHD 225
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98 144 98
‘h’ n
omin
al
98 144 98
‘h’ n
omin
al
98 144 98
150
98 144
230
98
SWL 5:1 (kN)
SWL 5:1 (kN)
6001800
156 156 156
19.6 19.6 19.6
61 52 45
12.6 12.6 12.6
19502100
22502400
72 62 53
6001800
236 236 236 236
23.3 23.3 23.3 23.3
75 60 46 35
19503000
31503900
4050 4800
89
21.5
71
21.5
55
21.5
37
20.5
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 5:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
RM (kNm)
6001650
150 150 150
24.9 24.9 24.9
55 43 32
46 36 27
11.1 11.1 11.1
18002100
22502700
6002100
225 225 225 225
30.5 30.5 30.5 30.5
79 60 49 41
66 51 41 34
20.6 20.6 20.6 20.6
22502700
28503300
34503900
sL150 XHD 150
sL150 XHD 225
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98144
150
98
98 144
225
98
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
See installation notes page 5
See installation notes page 5
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
140 153 190 190 215 215
8.6 9.0 10.2 15.2 16.4 21.2
42 40 41 41 33 33
33 31 32 32 26 26
5.6 6.8 10.0 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
10bAcK… to ‘Contents’ page
WiD
e inn
er LeAF (W
iL)
APPLicATiOnThese lintels are suitable to support a 125-150mm inner leaf of blockwork.
standard (WiL) and Heavy Duty (HD WiL)Designed to support:• Masonry loads• Masonry loads and uniformly distributed timber
fl oor loads• Uniformly distributed roof loads (in most cases
HD lintel type is required)
extra Heavy Duty (XHD WiL) and composite extra Heavy Duty (cXHD WiL)Designed to support:• Concrete fl oor loads• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
Additional requirements for composite extra Heavy Duty (cXHD WiL) • Ensure that the inner leaf channel is fi lled with
well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner fl ange of the lintel.
• Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured.
ADvAnTAGes:• Easy to install and suitable for a variety of
applications• Galvanised coating ensures durability/longevity• Built-in plaster key – perforated base plate to
inner fl ange• Excellent thermal effi ciency of up to 0.32 W/mK• Built-in continuous insulation
% if in doubt please contact our technical department on
0870 7503167
cAviTY WALL WIDE INNER LEAF (WIL)
11bAcK… to ‘Contents’ page
sL150
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
cA
viTY
50 WiL
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95 113 134 140 153 185 190 190 215
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
10.2 11.0 12.0 12.3 12.9 14.4 14.5 14.5 18.7
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
26 26 31 31 31 31 37 28 28
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
20 20 24 24 24 24 29 22 22
RM (kNm)
RM (kNm)
3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3 16.2
13501500
16501800
6001800
156 156 156
17.1 17.1 17.1
72
61
62
52
53
45
12.6 12.6 12.6
19502100
22502400
19502100
6001800
236 236 236 236
20.5 20.5 20.5 20.5
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
19503000
31503900
4050 4800
22502400
25502700
28503000
31503900
4050 4200sL50 WiL
sL50 HD WiL
sL50 cXHD 150 WiL
sL50 cXHD 225 WiL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
98 44 135
‘h’ n
omin
al
98 44 135
150
140
150
4498
98 44 140
225
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
100mm outer leaf50 - 65mm cavity125 -150mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 5:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
RM (kNm)
6001650
150 150 150
23.7 23.7 23.7
55 43 32
46 36 27
11.1 11.1 11.1
18002100
22502700
6002100
225 225 225 225
28.7 28.7 28.7 28.7
79 60 49 41
66 51 41 34
20.6 20.6 20.6 20.6
22502700
28503300
34503900
sL50 XHD 150 WiL
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sL50 XHD 225 WiL
See installation notes page 11
See installation notes page 11
98
‘h’ n
omin
al
44 135
135
230
6498
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
134 140 153 190 215 215
12.0 12.3 12.9 14.5 15.8 18.7
48 45 36 41 33 33
38 35 28 32 26 26
6.4 7.7 8.8 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
12bAcK… to ‘Contents’ page
100mm outer leaf70 - 85mm cavity100 -150mm inner leaf
100mm outer leaf70 - 85mm cavity100 -150mm inner leaf
100mm outer leaf70 - 85mm cavity100 - 150mm inner leaf
100mm outer leaf70 - 85mm cavity100 -150mm inner leaf
cA
viTY
70 WiL
sL70 WiLsTAnDArD LenGTHs (mm) 6001200
Nominal Height “h” (mm) 95 113 134 140 153 185 190 190 207
Weights (kg/m) 10.6 11.5 12.4 12.7 13.3 14.8 14.9 14.9 18.7
SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 28
SWL 19:1 (kN) 20 20 24 24 24 24 29 22 22
RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3 16.2
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4200
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
SWL 19:1 (kN)
RM (kNm)
236 236 236 236
20.5 20.5 20.5 20.5
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
6001800
19503000
31503900
4050 4800
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
156 156 156
17.1 17.1 17.1
72 62 53
61
12.6
52
12.6
45
12.6
6001800
19502100
22502400
sL70 HD WiL
sL70 cXHD 225 WiL
sL70 cXHD 150 WiL
1356498
‘h’ n
omin
al
98 64 135
‘h’ n
omin
al
98 64 135
150
135
230
6498
100mm outer leaf70 - 85mm cavity100 -150mm inner leaf
100mm outer leaf70 - 85mm cavity100 -150mm inner leaf
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 19:1 (kN)
SWL 5:1 (kN)
RM (kNm)
225 225 225 225
28.7
66
28.7
51
28.7
41
28.7
34
79
20.6
60
20.6
49
20.6
41
20.6
6002100
22502700
28503300
34503900
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
150 150 150
23.7 23.7 23.7
55 43 32
46
11.1
36
11.1
27
11.1
6001650
18002100
22502700
sL70 XHD 225 WiL
sL70 XHD 150 WiL
140
150
6498
98 64 140
225
Suitable to support precast concrete fl oors,attic trusses, and point loads.
See installation notes page 11
See installation notes page 11
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
134 140 153 190 207 207
12.4 12.7 13.3 14.9 15.8 18.7
48 45 36 41 33 33
38 35 28 32 26 26
6.4 7.7 8.8 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
13bAcK… to ‘Contents’ page
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
1359498
‘h’ n
omin
al
98 94 135
‘h’ n
omin
al
98 94 135
150
1359498
230
cA
viTY
100 WiL
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95 113 134 140 153 185 190 190 225
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
10.8 11.6 12.7 13.0 13.6 15.1 15.2 15.2 20.5
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
SWL 5:1 (kN)
26 26 31 31 31 31 37 28 28
SWL 19:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
20 20 24 24 24 24 29 22 22
RM (kNm)
RM (kNm)
SWL 19:1 (kN)
RM (kNm)
3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3 16.2
13501500
16501800
6001800
156 156 156
17.9 17.9 17.9
72 62 53
61
12.6
52
12.6
45
12.6
19502100
22502400
19502100
6001800
236 236 236 236
21.4 21.4 21.4 21.4
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
19503000
31503900
4050 4800
22502400
25502700
28503000
31503900
4050 4200sL100 WiL
sL100 HD WiL
sL100 cXHD 150 WiL
sL100 cXHD 225 WiL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
100mm outer leaf100 - 110mm cavity125 -150mm inner leaf
1409498
150
98 94 140
225
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 5:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
RM (kNm)
6001650
150 150 150
24.4 24.4 24.4
55 43 32
46 36 27
11.1 11.1 11.1
18002100
22502700
6002100
225 225 225 225
29.6 29.6 29.6 29.6
79 60 49 41
66 51 41 34
20.6 20.6 20.6 20.6
22502700
28503300
34503900
sL100 XHD 150 WiL
sL100 XHD 225 WiL
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
See installation notes page 11
See installation notes page 11
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
134 140 153 190 225 225
12.7 13.0 13.6 15.2 17.0 20.5
48 45 36 41 33 33
38 35 28 32 26 26
6.4 7.7 8.8 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
14bAcK… to ‘Contents’ page
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
cA
viTY
120 WiL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sL120 HD WiL
sL120 cXHD 225 WiL
sL120 cXHD 150 WiL
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
sL120 WiL
13511498
‘h’ n
omin
al
98 114 135
‘h’ n
omin
al
98 114 135
150
13511498
230
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
100mm outer leaf120 - 135mm cavity125 -150mm inner leaf
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sL120 XHD 225 WiL
sL120 XHD 150 WiL
14011498
150
98 114 140
225
sTAnDArD LenGTHs (mm) 6001200
Nominal Height “h” (mm) 95 113 134 140 153 185 190 190 205
Weights (kg/m) 11.4 12.2 13.2 13.4 14.0 15.6 15.7 15.7 20.5
SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28 28
SWL 19:1 (kN) 20 20 24 24 24 24 29 22 22
RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3 16.2
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4200
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 1:1/3:1 (kN)
SWL 19:1 (kN)
RM (kNm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 19:1 (kN)
SWL 5:1 (kN)
RM (kNm)
225 225 225 225
30.6
66
30.6
51
30.6
41
30.6
34
79
20.6
60
20.6
49
20.6
41
20.6
6002100
22502700
28503300
34503900
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Weights (kg/m)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
150 150 150
25.5 25.5 25.5
55 43 32
46
11.1
36
11.1
27
11.1
6001650
18002100
22502700
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
236 236 236 236
22.5 22.5 22.5 22.5
6001800
19503000
31503900
4050 4800
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
156 156 156
18.9 18.9 18.9
6001800
19502100
22502400
72 62 53
61
12.6
52
12.6
45
12.6See installation notes page 11
See installation notes page 11
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
134 140 153 190 205 205
13.2 13.4 14.0 15.7 16.4 20.5
48 45 36 41 33 33
38 35 28 32 26 26
6.4 7.7 8.8 13.3 15.5 16.2
13501500
16502100
22502700
28503900
4050 4200
15bAcK… to ‘Contents’ page
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
cA
viTY
150 WiL
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95 113 134 140 153 185 190
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
11.7 12.6 13.6 13.8 14.4 15.9 16.0
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
26 26 31 31 31 31 37
SWL 19:1 (kN)
SWL 19:1 (kN)
20 20 24 24 24 24 29
RM (kNm)
RM (kNm)
3.5 4.5 6.4 7.7 8.8 9.9 13.3
13501500
16501800
19502100
22502400
25502700
28503000
31503900
4050 4200sL150 WiL
sL150 HD WiL
sL150 cXHD 150 WiL
sL150 cXHD 225 WiL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
13514498
‘h’ n
omin
al
98 144 135
‘h’ n
omin
al
98 144 135
150
13514498
230
SWL 5:1 (kN)
SWL 5:1 (kN)
6001800
236 236 236
24.3 24.3 24.3
19503000
31503900
4050 4800
89
75
21.5
71
60
21.5
55
46
21.5
37
24.3
236
35
20.5
SWL 19:1 (kN)
RM (kNm)
6001800
156 156 156
20.4 20.4 20.4
19502100
22502400
72 62 53
61
12.6
52
12.6
45
12.6
SWL 19:1 (kN)
RM (kNm)
190 215
16.0 22.0
28 28
22 22
13.3 16.2
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
100mm outer leaf150 - 165mm cavity125 -150mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Weights (kg/m)
Weights (kg/m)
SWL 5:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
SWL 19:1 (kN)
RM (kNm)
RM (kNm)
6001650
150 150 150
27.0 27.0 27.0
55 43 32
46 36 27
11.1 11.1 11.1
18002100
22502700sL150 XHD 150 WiL
sL150 XHD 225 WiL
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
14014498
150
98 144 140
225
6002100
225 225 225
32.5 32.5 32.5
79 60 49
66 51 41
20.6 20.6 20.6
22502700
28503300
34503900
225
32.5
41
34
20.6
See installation notes page 11
See installation notes page 11
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
6001200
134 140 153 190
13.6 13.8 14.4 16.0
48 45 36 41
38 35 28 32
6.4 7.7 8.8 13.3
13501500
16502100
22502700
28503900
4050 4200
215 215
17.3 22.0
33 33
26 26
15.5 16.2
16bAcK… to ‘Contents’ page
WiD
e OU
Ter LeAF (W
OL)
APPLicATiOnThese lintels are suitable to support a 125-150mm outer leaf of blockwork or stonework.
standard and Heavy Duty (HD WOL)Designed to support:• Masonry loads• Masonry loads and uniformly distributed timber
fl oor loads• Uniformly distributed roof loads (in most cases
HD lintel type is required)
extra Heavy Duty (XHD WOL) and composite extra Heavy Duty (cXHD WOL)Designed to support:• Concrete fl oor loads• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
Additional requirements for composite extra Heavy Duty (cXHD WOL) • Ensure that the inner leaf channel is fi lled with
well cured masonry before work proceeds over. Masonry needs to be built tightly against the vertical section of the channel and a mortar joint added to the top of masonry, so that the loads from units above are spread evenly over the inner fl ange of the lintel.
• Composite lintels should be adequately propped during construction, at maximum 1.2 metre centres. Props should not be removed until the mortar has cured.
ADvAnTAGes• Easy to install and suitable for a variety of
applications• Galvanised coating ensures durability/longevity• Built-in plaster key – perforated base plate to
inner fl ange• Excellent thermal effi ciency of up to 0.32 W/mK• Built-in continuous insulation
% if in doubt please contact our technical department on
0870 7503167
cAviTY WALLWIDE OUTER LEAF (WOL)
17bAcK… to ‘Contents’ page
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
cA
viTY
50 WO
L
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
6001200
6001800
6001800
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95
134
156
236
113
140
156
236
134
153
156
236
140
190
236
153
215
185 190 190
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
10.2
12.0
17.1
20.5
11.0
12.3
17.1
20.5
12.0
12.9
17.1
20.5
12.3
14.5
20.5
12.9
15.8
14.4 14.5 14.5
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
26
48
26
45
31
36
31
41
31
33
31 37 28
SWL 19:1 (kN)
SWL 19:1 (kN)
20
38
20
35
24
28
24
32
24
26
24 29 22
RM (kNm)
RM (kNm)
3.5
6.4
4.5
7.7
6.4
8.8
7.7
13.3
8.8
15.5
9.9 13.3 13.3
13501500
13501500
19502100
19503000
16501800
16502100
22502400
31503900
19502100
22502700
4050 4800
22502400
28503900
25502700
28503000
31503900sL50 WOL
sL50 HD WOL
sL50 cXHD 150 WOL
sL50 cXHD 225 WOL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
SWL 5:1 (kN)
SWL 5:1 (kN)
72
89
75
21.5
62
71
60
21.5
53
55
46
21.5
37
35
20.5
SWL 19:1 (kN)
RM (kNm)
61
12.6
52
12.6
45
12.6
SWL 19:1 (kN)
RM (kNm)
135 44 98
‘h’ n
omin
al
9844135
‘h’ n
omin
al
9844135
150
9844135
230
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
125 -150mm outer leaf50 - 65mm cavity100mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001650
6002100
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
225
150
225
150
225 225
Weights (kg/m)
Weights (kg/m)
22.4
27.6
22.4
27.6
22.4
27.6 27.6
SWL 5:1 (kN)
SWL 5:1 (kN)
55
79
43
60
32
49 41
SWL 19:1 (kN)
SWL 19:1 (kN)
46
66
36
51
27
41 34
RM (kNm)
RM (kNm)
11.1
20.6
11.1
20.6
11.1
20.6 20.6
18002100
22502700
22502700
28503300
34503900
sL50 XHD 150 WOL
sL50 XHD 225 WOL
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
9844135
150
135 44 98
225
See installation notes page 17
See installation notes page 17
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
18bAcK… to ‘Contents’ page
cA
viTY
70 WO
L125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
sL70 WOLsTAnDArD LenGTHs (mm) 6001200
Nominal Height “h” (mm) 95 113 134 140 153 185 190 190
Weights (kg/m) 10.6 11.5 12.4 12.7 13.3 14.8 14.9 14.9
SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28
SWL 19:1 (kN) 20 20 24 24 24 24 29 22
RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3
13501500
16501800
19502100
22502400
25502700
28503000
31503900
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
134 140
236
153
236
190
236
207
236
Weights (kg/m)
Weights (kg/m)
12.4 12.7
20.5
13.3
20.5
14.9
20.5
15.8
20.5
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
48 45
89
75
21.5
36
71
60
21.5
41
55
46
21.5
33
37
35
20.5
SWL 19:1 (kN) 38 35 28 32 26
RM (kNm) 6.4 7.7 8.8 13.3 15.5
13501500
6001800
16502100
19503000
22502700
31503900
28503900
4050 4800
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm) 156 156 156
Weights (kg/m) 17.1 17.1 17.1
SWL 5:1 (kN) 72 62 53
SWL 19:1 (kN)
RM (kNm)
61
12.6
52
12.6
45
12.6
6001800
19502100
22502400
sL70 HD WOL
sL70 cXHD 225 WOL
sL70 cXHD 150 WOL
135 64 98
‘h’ n
omin
al
9864135
‘h’ n
omin
al
9864135
150
9864135
230
Suitable to support precast concrete fl oors,attic trusses, and point loads.
125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
125 - 150mm outer leaf70 - 85mm cavity100mm inner leaf
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm) 225 225 225 225
Weights (kg/m)
SWL 19:1 (kN)
27.6
66
27.6
51
27.6
41
27.6
34
SWL 5:1 (kN)
RM (kNm)
79
20.6
60
20.6
49
20.6
41
20.6
6002100
22502700
28503300
34503900
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm) 150 150 150
Weights (kg/m) 22.4 22.4 22.4
SWL 5:1 (kN) 55 43 32
SWL 19:1 (kN)
RM (kNm)
46
11.1
36
11.1
27
11.1
6001650
18002100
22502700
sL70 XHD 225 WOL
sL70 XHD 150 WOL
9864135
150
135 64 98
225
Suitable to support precast concrete fl oors,attic trusses, and point loads.
See installation notes page 17
See installation notes page 17
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
19bAcK… to ‘Contents’ page
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
cA
viTY
100 WO
L
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
6001200
6001800
6001800
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95
134
156
236
113
140
156
236
134
153
156
236
140
190
236
153
225
185 190 190
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
10.8
12.7
17.9
21.2
11.6
13.0
17.9
21.2
12.7
13.6
17.9
21.2
13.0
15.2
21.2
13.6
17.0
15.1 15.2 15.2
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
26
48
26
45
31
36
31
41
31
33
31 37 28
SWL 19:1 (kN)
SWL 19:1 (kN)
20
38
20
35
24
28
24
32
24
26
24 29 22
RM (kNm)
RM (kNm)
3.5
6.4
4.5
7.7
6.4
8.8
7.7
13.3
8.8
15.5
9.9 13.3 13.3
13501500
13501500
19502100
19503000
16501800
16502100
22502400
31503900
19502100
22502700
4050 4800
22502400
28503900
25502700
28503000
31503900sL100 WOL
sL100 HD WOL
sL100 cXHD 150 WOL
sL100 cXHD 225 WOL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
135 94 98
‘h’ n
omin
al
9894135
‘h’ n
omin
al
9894135
150
9894135
230
SWL 5:1 (kN)
SWL 5:1 (kN)
72
89
75
21.5
62
71
60
21.5
53
55
46
21.5
37
35
20.5
SWL 19:1 (kN)
RM (kNm)
61
12.6
52
12.6
45
12.6
SWL 19:1 (kN)
RM (kNm)
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
125 - 150mm outer leaf100 - 110mm cavity100mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001650
6002100
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
225
150
225
150
225 225
Weights (kg/m)
Weights (kg/m)
23.2
28.4
23.2
28.4
23.2
28.4 28.4
SWL 5:1 (kN)
SWL 5:1 (kN)
55
79
43
60
32
49 41
SWL 19:1 (kN)
SWL 19:1 (kN)
46
66
36
51
27
41 34
20.6
RM (kNm) 11.1 11.1 11.1
18002100
22502700
22502700
28503300
34503900
sL100 XHD 150 WOL
sL100 XHD 225 WOL
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
9894135
150
135 94 98
225
RM (kNm) 20.6 20.6 20.6
See installation notes page 17
See installation notes page 17
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
20bAcK… to ‘Contents’ page
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
125 - 150mm outer leaf120 - 135mm cavity100mm inner leaf
cA
viTY
120 WO
LsL120 WOLsTAnDArD LenGTHs (mm) 600
1200
Nominal Height “h” (mm) 95 113 134 140 153 185 190 190
Weights (kg/m) 11.4 12.2 13.2 13.4 14.0 15.6 15.7 15.7
SWL 1:1/3:1 (kN) 26 26 31 31 31 31 37 28
SWL 19:1 (kN) 20 20 24 24 24 24 29 22
RM (kNm) 3.5 4.5 6.4 7.7 8.8 9.9 13.3 13.3
13501500
16501800
19502100
22502400
25502700
28503000
31503900
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
134 140
236
225
153
236
225
190
236
225
205
236
225
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
SWL 19:1 (kN)
13.2 13.4
22.4
29.6
66
14.0
22.4
29.6
51
15.7
22.4
29.6
41
16.4
22.4
29.6
34
SWL 1:1/3:1 (kN)
SWL 5:1 (kN)
RM (kNm)
48 45
79
20.6
36
60
20.6
41
49
20.6
33
41
20.6
SWL 19:1 (kN) 38 35 28 32 26
RM (kNm) 6.4 7.7 8.8 13.3 15.5
13501500
6001800
6002100
16502100
19503000
22502700
22502700
31503900
28503300
28503900
4050 4800
34503900
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
156
150
156
150
156
150
Weights (kg/m)
Weights (kg/m)
19.3
24.6
19.3
24.6
19.3
24.6
SWL 5:1 (kN) 55 43 32
SWL 19:1 (kN)
RM (kNm)
46
11.1
36
11.1
27
11.1
6001800
6001650
19502100
18002100
22502400
22502700
sL120 HD WOL
sL120 cXHD 225 WOL
sL120 XHD 225 WOL
sL120 cXHD 150 WOL
sL120 XHD 150 WOL
SWL 5:1 (kN)
SWL 19:1 (kN)
RM (kNm)
89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
SWL 5:1 (kN) 72 62 53
SWL 19:1 (kN)
RM (kNm)
61
12.6
52
12.6
45
12.6
135 114 98
‘h’ n
omin
al
98114135
‘h’ n
omin
al
98114135
150
98114135
230
98114135
150
135 114 98
225
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
See installation notes page 17
See installation notes page 17
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
21bAcK… to ‘Contents’ page
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
cA
viTY
150 WO
L
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
95
134
113
140
134
153
140
190
153
215
185 190 190
Weights (kg/m)
Weights (kg/m)
11.7
13.6
12.6
13.8
13.6
14.4
13.8
16.0
14.4
17.3
15.9 16.0 16.0
SWL 1:1/3:1 (kN)
SWL 1:1/3:1 (kN)
26
48
26
45
31
36
31
41
31
33
31 37 28
SWL 19:1 (kN)
SWL 19:1 (kN)
20
38
20
35
24
28
24
32
24
26
24 29 22
RM (kNm)
RM (kNm)
3.5
6.4
4.5
7.7
6.4
8.8
7.7
13.3
8.8
15.5
9.9 13.3 13.3
13501500
13501500
16501800
16502100
19502100
22502700
22502400
28503900
25502700
28503000
31503900sL150 WOL
sL150 HD WOL
sL150 cXHD 150 WOL
sL150 cXHD 225 WOL
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Not suitable to support precast concrete fl oors, attic trusses, heavy point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
135 144 98
‘h’ n
omin
al
98144135
‘h’ n
omin
al
98144135
150
98144135
230
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
125 - 150mm outer leaf150 - 165mm cavity100mm inner leaf
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001650
6002100
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
225
150
225
150
225 225
Weights (kg/m)
Weights (kg/m)
25.7
31.3
25.7
31.3
25.7
31.3 31.3
SWL 5:1 (kN)
55
79
43
60
32
49 41
SWL 19:1 (kN)
46
66
36
51
27
41 34
RM (kNm)
11.1
20.6
11.1
20.6
11.1
20.6 20.6
18002100
22502700
22502700
28503300
34503900
sL150 XHD 150 WOL
sL150 XHD 225 WOL
98144135
150
135 144 98
225
SWL 5:1 (kN) 55 43 32
SWL 19:1 (kN) 46 36 27
RM (kNm) 11.1 11.1 11.1
sTAnDArD LenGTHs (mm) 6001800
Nominal Height “h” (mm) 156 156 156
Weights (kg/m) 20.5 20.5 20.5
19502100
22502400
SWL 19:1 (kN)
RM (kNm)
61
12.6
52
12.6
45
12.6
SWL 5:1 (kN) 72 62 53
sTAnDArD LenGTHs (mm) 6001800
Nominal Height “h” (mm) 236 236 236 236
Weights (kg/m) 24.1 24.1 24.1 24.1
19503000
31503900
4050 4800
SWL 5:1 (kN) 89
75
21.5
71
60
21.5
55
46
21.5
37
35
20.5
SWL 19:1 (kN)
RM (kNm)
Suitable to support precast concrete fl oors,attic trusses, and point loads.
Suitable to support precast concrete fl oors,attic trusses, and point loads.
See installation notes page 17
See installation notes page 17
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
22bAcK… to ‘Contents’ page
rOLLeD
sTeeL secTiO
ns
APPLicATiOn Rolled Steel (RS) and Rolled Steel Channel (RSC) fabricated lintels are designed for extreme loading conditions:• Masonry loads• Concrete fl oor loads• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTes See page 46 for general installation notes.
Additional requirements for rs and rsc type lintels • Lintels must be laterally restrained and
adequately propped during construction at maximum 1.2 metre centres. Props should not be removed until the mortar has cured.
• Minimum of 200mm bearing is required• RSC type lintels - channel MUST be fi lled with
masonry before the work proceeds over and needs to be built tightly against the vertical section of the channel using good quality, well bonded mortar joints.
mATeriAL Lintels are manufactured using 203x133x30kg/m UB or 230x90x32.2kg/m RSC with a 6mm welded bottom plate to BS EN 10025 – 2: 2004 of steel grade S275.
FinisHinGLintels are coated as standard in a red-oxide paint. However, they can be supplied, at extra cost, with a galvanised fi nish.
ADvAnTAGes• Available in 50mm increments with a maximum
length of 6600mm• Can suit a variety of cavity wall constructions• Availability 7-8 working days (red oxide fi nish)
rOLLeD sTeeL secTiOns
% if in doubt please contact our technical department on
0870 7503167
23bAcK… to ‘Contents’ page
See installation notes page 23
See installation notes page 23
See installation notes page 23
See installation notes page 23
See installation notes page 23
rOLLeD
sTeeL secTiO
ns
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
9004800
9004800
9004800
9004800
9004800
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
213
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
41.6
42.9
44.6
45.6
47.1
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
82
82
82
82
82
77
77
77
77
77
72
72
72
72
72
67
67
67
67
67
64
64
64
64
64
60
60
60
60
60
58
58
58
58
58
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
5100
5100
5100
5100
5100
5400
5400
5400
5400
5400
5700
5700
5700
5700
5700
6000
6000
6000
6000
6000
6300
6300
6300
6300
6300
6600
6600
6600
6600
6600
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
sL50/rs
sL70/rs
sL100/rs
sL120/rs
sL150/rs
240
213
265
213
300
213
320
213
350
213
.
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
24bAcK… to ‘Contents’ page
rOLLeD
sTeeL secTiO
ns
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
9004800
9004800
9004800
9004800
9004800
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
236
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
44.1
45.4
46.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
44.1
45.4
44.6
47.6
49.1
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
SWL 5:1/19:1 (kN)
95
95
95
95
95
90
90
90
90
90
85
85
85
85
85
80
80
80
80
80
76
76
76
76
76
72
72
72
72
72
69
69
69
69
69
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
55.7
5100
5100
5100
5100
5100
5400
5400
5400
5400
5400
5700
5700
5700
5700
5700
6000
6000
6000
6000
6000
6300
6300
6300
6300
6300
6600
6600
6600
6600
6600
sL50/rsc
sL70/rsc
sL100/rsc
sL120/rsc
sL150/rsc
240
230
265
230
295
230
315
230
345
230
See installation notes page 23
See installation notes page 23
See installation notes page 23
See installation notes page 23
See installation notes page 23
100mm outer leaf70 - 85mm cavity100 -115mm inner leaf
100mm outer leaf100 - 110mm cavity100 -115mm inner leaf
100mm outer leaf120 - 135mm cavity100 -115mm inner leaf
100mm outer leaf150 - 165mm cavity100 -115mm inner leaf
100mm outer leaf50 - 65mm cavity100 -115mm inner leaf
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
Lintels are available in increments of 50mm
25bAcK… to ‘Contents’ page
cLO
seD eA
ves
APPLicATiOn Open back Lintel (e)Designed to support:• Standard truss roof loads
Heavy Duty box section Lintel (e HD and e XHD)Designed to support:• Attic trusses• Compound trusses
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
Open Back Eaves Lintels must be built in with a course of blockwork positioned tightly against the up-stand of the lintel and a continuous timber wall plate as shown in the illustration.
ADvAnTAGes• Available in 150mm increments• The curtain brackets on Open Back Eaves
Lintels can be easily fi xed without the need of timber battens
• Loads on Eaves HD type lintels can be applied directly to the box section, without the aid of another course of blockwork
• Can suit a variety of cavity wall constructions• Built-in plaster key – perforated base plate to
inner fl ange• Excellent thermal effi ciency provided by the
continuous insulation• Lintels suitable for wider cavities are available
on request
cLOseD eAves
% if in doubt please contact our technical department on
0870 7503167
26bAcK… to ‘Contents’ page
cLO
seD eA
ves 50
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001500
6001500
6001500
6001500
6001500
6001500
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150 150
150 150
150
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
9.9
7.8
10.7
16.2
14.8
7.2
9.9
7.8
10.7
16.2
14.8
7.2
9.9
11.6
10.7
16.2
14.8
10.7
9.9
11.6
10.7
16.2
14.8
10.7
9.9
11.6
10.7
16.2 16.2
14.8 14.8
10.7
SWL (kN)
SWL (kN)
SWL (kN)
SWL (kN)
SWL (kN)
SWL (kN)
46
21
46
54
54
21
38
18
38
45
45
18
32
20
32
38
38
20
28
17
28
33
33
17
24
15
24
29 26
29 26
15
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
7.8
3.6
7.8
9.2
9.2
3.6
7.8
3.6
7.8
9.2
9.2
3.6
7.8
4.8
7.8
9.2
9.2
4.8
7.8
4.8
7.8
9.2
9.2
4.8
7.8
4.8
7.8
9.2 9.2
9.2 9.2
4.8
16501800
16501800
16501800
16501800
16501800
16501800
19502100
19502100
19502100
19502100
19502100
19502100
22502400
22502400
22502400
22502400
22502400
22502400
25502700
25502700
25502700
25502700
28503000
25502700
28503000
25502700
sL50/e HD
sL50/e WiL
sL50/e HD WiL
sL50/e XHD WiL
sL50/e XHD
sL50/e
50 44 98
150
104 96
150
104 96
150
50 44 13515
0
104 125
150
104 125
150
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
50 - 80mm cavity100 -115mm inner leaf
50 - 80mm cavity100 -115mm inner leaf
50 - 80mm cavity100 -115mm inner leaf
50 - 80mm cavity125 -150 inner leaf
50 - 80mm cavity125 -150 inner leaf
50 - 80mm cavity125 -150 inner leaf
27bAcK… to ‘Contents’ page
cLO
seD eA
ves 100
sTAnDArD LenGTHs (mm) 6001500
Nominal Height “h” (mm) 150 150 150 150 150 150
Weights (kg/m) 15.6 15.6 15.6 15.6 15.6 15.6
SWL (kN) 54 45 38 33 29 26
RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2
16501800
19502100
22502400
25502700
28503000
sTAnDArD LenGTHs (mm) 6001500
Nominal Height “h” (mm) 150 150 150 150 150 150
Weights (kg/m) 17.0 17.0 17.0 17.0 17.0 17.0
SWL (kN) 54 45 38 33 29 26
RM (kNm) 9.2 9.2 9.2 9.2 9.2 9.2
16501800
19502100
22502400
25502700
28503000
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001500
6001500
6001500
6001500
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
7.5
10.5
8.1
11.3
7.5
10.5
8.1
11.3
11.1
10.5
12.0
11.3
11.1
10.5
12.0
11.3
11.1
10.5
12.0
11.3
SWL (kN)
SWL (kN)
SWL (kN)
SWL (kN)
21
46
21
46
18
38
18
38
20
32
20
32
17
28
17
28
15
24
15
24
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
3.6
7.8
3.6
7.8
3.6
7.8
3.6
7.8
4.8
7.8
4.8
7.8
4.8
7.8
4.8
7.8
4.8
7.8
4.8
7.8
16501800
16501800
16501800
16501800
19502100
19502100
19502100
19502100
22502400
22502400
22502400
22502400
25502700
25502700
25502700
25502700
sL100/e
sL100/e HD
sL100/e WiL
sL100/e HD WiL
sL100/e XHD
sL100/e XHD WiL
50 84 98
150
138 96
150
50 84 135
150
138 125
150
138 96
150
138 125
150
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
90 - 120mm cavity100 -115mm inner leaf
90 - 120mm cavity100 -115mm inner leaf
90 - 120mm cavity100 -115mm inner leaf
90 - 120mm cavity125 -150 inner leaf
90 - 120mm cavity125 -150 inner leaf
90 - 120mm cavity125 -150 inner leaf
28bAcK… to ‘Contents’ page
Timber FrA
me
APPLicATiOnTimber Frame Lintels (TF) are designed for use in timber frame construction and are intended to support the outer leaf of masonry only, generally brickwork.
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
Additional requirements for (TF) type lintels• To avoid excessive defl ection and possible
twisting, lintels should be secured laterally with restraining clips and should be adequately propped during construction at maximum 1.2 meter centres. Props can be removed after the mortar has cured.
• A tight fi tting timber batten (supplied by others) should be placed at mid span to help prevent any lateral defl ection.
• Restraining clips to be spaced at maximum 500mm centres, starting from mid span. Clips must be nailed to the timber frame.
ADvAnTAGes• Easy to install and suitable for a variety of cavity
walls• Galvanised coating ensures durability/longevity• Supplied with appropriate number of restraining
clips
% if in doubt please contact our technical department on
0870 7503167
Timber FrAme
29bAcK… to ‘Contents’ page
Timber FrA
me
98 47
‘h’ n
omin
al
98 67
‘h’ n
omin
al
98 97
‘h’ n
omin
al
sL50 TF
sL70 TF
sL100 TF
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001200
6001200
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
125
130
146
122
141
157
135
161
174
185
185
220
190
200
245
215
215
280
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
3.8
4.1
4.8
5.6
4.3
7.5
6.0
7.1
7.9
7.2
7.6
9.0
7.3
7.8
9.7
7.9
8.1
10.5
SWL (kN)
SWL (kN)
SWL (kN)
9
1.2
9
9
1.2
1.2
9
1.9
9
9
1.6
1.9
9
2.6
9
9
2.6
2.6
11
4.0
11
11
4.0
4.0
11
4.8
11
11
4.8
4.8
13
6.2
13
13
6.2
6.2
RM (kNm)
RM (kNm)
RM (kNm)
13501800
13501500
13501800
19502400
16502400
19502400
25503000
25503000
25503000
31503600
31503600
31503600
37503900
37503900
37503900
See installation notes page 29
See installation notes page 29
See installation notes page 29
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
50 - 65mm cavity102mm outer leaf
70 - 80mm cavity102mm outer leaf
90 - 100mm cavity102mm outer leaf
30bAcK… to ‘Contents’ page
sinG
Le LeAF eX
TernA
L sOLiD
WA
LL
APPLicATiOnTray (Tr) and channel (cH)Designed to support:• 100mm external leaf solid blockwork• 102mm external leaf brickwork • 140mm external leaf solid blockwork
(TR WL and/or CH WL)
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTes See page 46 for general installation notes.
Additional requirements for (Tr) and (cH) type lintels• To avoid excessive defl ection and possible
twisting, lintels should be adequately propped during construction at maximum 1.2 metre centres. Props can be removed after the mortar has cured.
• To achieve stated loading fi gures, Channel Lintels (CH) MUST be fi lled with well cured masonry before work proceeds over.
ADvAnTAGes• Easy to install• Suitable for faced brick/block walls• Suitable for use over meter boxes and garage
personnel doors• Galvanised coating ensures durability/longevity
% if in doubt please contact our technical department on
0870 7503167
sinGLe LeAF eXTernAL sOLiD WALL
31bAcK… to ‘Contents’ page
SING
LE LEAF EX
TERNA
L SOLID
WA
LL
SL100 CH 150
SL100 TR
SL100 CH 225
95
‘h’ n
omin
al
100
156
100
231
STANDARD LENGTHS (mm)
STANDARD LENGTHS (mm)
STANDARD LENGTHS (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
115
231
115
231
165
231
156
225
231
156
225
231
156
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
5.0
8.8
5.0
8.8
6.8
8.8
7.0
8.9
8.8
7.0
8.9
8.8
7.0
SWL (kN)
SWL (kN)
SWL (kN)
5
57
6
47
10
34
29
17
30
23
13
20
20
RM (kNm)
RM (kNm)
RM (kNm)
1.4
9.8
1.4
9.8
3.6
9.8
4.9
5.8
9.8
4.9
5.8
9.8
4.9
6001500
6001500
16501800
16501800
19502400
19502400
6001500
25503000
25503000
16501800
31503900
31503900
19502100
See installation notes page 31
See installation notes page 31
See installation notes page 31
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
32BACK… to ‘Contents’ page
inTern
AL sO
LiD W
ALL
APPLicATiOn Galvanised steel box lintels are designed for use in internal 100mm wide or 140-150mm wide, non-load bearing and load bearing walls.Designed to support:• Concrete fl oor loads• Masonry loads, timber fl oor joists and/or roof
trusses• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
ADvAnTAGes• Easy to install• Suitable for 100mm wide or 140-150mm wide
walls• Can be supplied insulated for use at eaves level• Galvanised coating ensures durability/longevity• Built-in plaster key – perforated plate to base
and two sides• Suitable for use under various loading
conditions
% if in doubt please contact our technical department on
0870 7503167
inTernAL sOLiD WALL
33bAcK… to ‘Contents’ page
inTern
AL sO
LiD W
ALL
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001500
6001200
6001500
6001200
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
108
150
150
150
108
225
150
225
150
225
150
225
150
150
225
225
225
225
225
225
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
6.9
8.3
9.7
9.7
6.9
15.9
9.7
18.0
8.3
15.9
9.7
18.0
8.3
9.7
15.9
18.0
15.9
18.0
15.9
18.0
SWL (kN)
SWL (kN)
SWL (kN)
SWL (kN)
24
51
50
60
4.1
7.8
8.6
8.6
20
75
35
80
4.1
15.5
8.6
17.2
28
49
30
54
7.8
15.5
8.6
17.2
24
26
7.8
8.6
35
40
15.5
17.2
30
34
27
29
15.5
17.2
15.5
17.2
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
16501800
13501800
16502100
13501800
19502400
19502700
22502400
19502700
25502700
25502700
28503600
28503600
37504200
37504200
43504800
43504800
sL100 bOX
sL100 bOX HD
sL140 bOX
sL140 bOX HD
Heavy Duty
Standard Duty
100 ‘h’ n
omin
al
100
‘h’ n
omin
al
140
‘h’ n
omin
al
140
‘h’ n
omin
al
140
‘h’ n
omin
al
140
‘h’ n
omin
al
Standard Duty
Heavy Duty
sL100 inT
sL75 inT
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
28
28
28
28
28
28
Weights (kg/m)
Weights (kg/m)
1.2
1.1
1.2
1.1
1.2
1.1
SWL (kN) with 150mm coursing
SWL (kN)
5
5
7
5
7
7
5
7
7SWL (kN) with 225mm coursing
900
900
1050
1050
1200
1200
NOTE: these loadings are achieved with the composite action of one course of blockwork built on top.The mortar MUST be allowed to harden for at least 24 hours before applying any additional loads.
NOTE: these loadings are achieved with the composite action of one course of blockwork built on top.The mortar MUST be allowed to harden for at least 24 hours before applying any additional loads.
Light Duty
Light Duty
100
28
75
28
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
34bAcK… to ‘Contents’ page
eXTern
AL sO
LiD W
ALL
APPLicATiOnGalvanised steel box lintels are designed for use in 200-215mm solid walls and are available in three different designs: box with a lip/toe (SL200 BOX), inverted ‘T’ section (SL200 T) or back to back channel (SL200 CH).Designed to support:• Concrete fl oor loads• Tile hanging• Masonry loads• Timber fl oor joists• Attic truss loads and/or roof trusses• Point loads for example compound trusses,
steel beams etc• SL200 BOX is designed to support 19:1 load ratio• SL200 CH and SL200 ‘T’ are designed to support
1:1 load ratio
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 46 for general installation notes.
Additional requirements for sL200 cH and sL200 ‘T’ type lintels:• To avoid excessive defl ection and possible
twisting, lintels should be adequately propped during construction at maximum 1.2 metre centres. Props should only be removed after the mortar has cured.
• To achieve stated loading fi gures, SL200 CH lintels MUST be fi lled with well cured masonry before work proceeds over.
ADvAnTAGes• Easy to install• Inverted ‘T’ and back to back channel sections
can be used to carry fair facing brick walls on both sides
• Can be used in tile-hanging external walls• Galvanised coating ensures durability/longevity• Suitable for use under various loading
conditions
% if in doubt please contact our technical department on
0870 7503167
eXTernAL sOLiD WALL
35bAcK… to ‘Contents’ page
eXTern
AL sO
LiD W
ALL
sL200 bOX
sL200 bOX HD
sL200 ‘T’
sL200 cH
Standard Duty
Standard Duty
Heavy Duty
Heavy Duty
200
‘h’ n
omin
al
200
‘h’ n
omin
al
200
‘h’ n
omin
al
200
225
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
sTAnDArD LenGTHs (mm)
6001500
6001500
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
Nominal Height “h” (mm)
150
150
150
225
150
225
231
225
231
225
75
231
225
95
231
255
175
231
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
Weights (kg/m)
9.9
14.8
9.9
18.4
14.8
18.4
17.6
18.4
17.6
18.4
7.7
17.6
18.4
8.7
17.6
18.4
12.5
17.6
SWL 19:1 (kN)
SWL 19:1(kN)
SWL 1:1(kN)
SWL 1:1(kN)
37
50
6.4
8.6
26
65
6.4
18.5
27
58
90
8.6
18.5
19
52
80
18.5
19
43
12
67
18.5
1.9
19
34
10
53
32
24
40
18.5
2.5
19
18.5
4.2
19
RM (kNm)
RM (kNm)
RM (kNm)
RM (kNm)
16502100
16501800
22502700
19502700
6001500
28503000
16501800
3150 3600
6001350
19502400
3750 4500
15002100
25503000
4650 4800
22502700
31503900
See installation notes page 35
See installation notes page 35
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
Lintels are available in increments of 150mm
36bAcK… to ‘Contents’ page
PresTresseD c
On
creTe
APPLicATiOnDesigned to support:• Masonry loads• Uniformly distributed timber fl oor loads• Uniformly distributed roof loads • Concrete fl oor loads• Attic truss loads• Point loads for example compound trusses,
steel beams etc
ALWAYS CHECK LOADINGS AGAINST OUR LOAD-SPAN TABLE
insTALLATiOn nOTesSee page 47 for general installation notes.
Additional requirements for lintels supporting concrete fl oor units• Check that the correct lintel has been installed.• Minimum recommended lintel depth is
140mm in order to absorb the shock loading of concrete fl oor. Precast fl ooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports.
ADvAnTAGes• Easy to install and suitable for a variety of
applications: internal partitions, external cavity walls, garages, over services.
• We offer a wide range of lintels from 100 x 65 through to 220 x 140 catering for every circumstance, with both ‘Universal’ and ‘Hi-Strength’ derivatives where required.
• If required, Stressline can schedule and deliver in house plots.
imPOrTAnT nOTes• The loading fi gures published in the load-
span tables represent the Uniform Distributed Serviceable Load (UDL) in kN/m which can be supported by the lintel without the provision of structural brickwork/blockwork over. This is known as Independent Design.
• Lintel lengths shown greyed out within the load-span table are available in longer lengths than the maximum clear span would normally allow. These longer lengths lintels should be used over a series of openings (with intermediate supports) NOT exceeding the maximum clear span and NOT simply supported at each end (i.e. all 65mm/70mm deep lintels must not clear span more than 1800mm).
% if in doubt please contact our technical department on
0870 7503167
PresTresseD cOncreTe
37bAcK… to ‘Contents’ page
prestressed C
ON
Crete
*UDL is restricted by shearMinimum manufactured length is 450mm Maximum manufactured length is 3000mm
100 x 65 stANdArd 600 750 900 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 LeNGtHs (mm)
Clear Span (mm) 300 450 600 750 900 1050 1200 1350 1500 1800 2100 2400 2700
Weight (kg/m) 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3 15.3
UDL (kN/m) 23.9* 23.9* 13.8* 8.9 6.5 5.3 4.1 3.2 2.6 1.8
RM (kNm) 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 6
5
100
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 2400mm
100 x 70 Hi-strength stANdArd 900 1200 1500 1800 2100 2400 LeNGtHs (mm)
Clear Span (mm) 600 900 1200 1500 1800 2100
Weight (kg/m) 16.5 16.5 16.5 16.5 16.5 16.5
UDL (kN/m) 23.9* 11.0 6.3 4.0 2.8
RM (kNm) 1.2 1.2 1.2 1.2 1.2
100
70
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
100 x 140 Hi-strength stANdArd 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200LeNGtHs (mm) 900
Clear Span (mm) 750 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900
Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0
UDL (kN/m) 68.7* 49.9* 40.2 35.0 27.0 21.9 17.7 12.5 9.2 7.1 5.6 4.5 3.7 2.6
RM (kNm) 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8
300600
100
140
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
r15A 100 x 140 stANdArd 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200LeNGtHs (mm) 900
Clear Span (mm) 750 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900
Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0
UDL (kN/m) 56.0* 40.2* 28.2 21.8 17.3 13.6 11.4 8.1 6.1 4.6 3.6 2.9 2.4 1.5
RM (kNm) 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7
300600
100
140
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
r22A 100 x 220 stANdArd 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200LeNGtHs (mm)
Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900
Weight (kg/m) 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7
UDL (kN/m) 67.6* 67.6* 51.4 44.5 35.3 23.7 17.5 13.2 10.3 8.3 6.8 5.7 4.8 3.6
RM (kNm) 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7 8.7
100
220
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 3000mm
140 x 65 stANdArd 600 900 1050 1200 1350 1500 1800 2100 2400 2700 3000LeNGtHs (mm)
Clear Span (mm) 300 600 750 900 1050 1200 1500 1800 2100 2400 2700
Weight (kg/m) 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2 22.2
UDL (kN/m) 33.0* 18.8* 12.3 8.6 6.3 4.8 3.1 2.1
RM (kNm) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
140
65
38BACK… to ‘Contents’ page
prestressed C
ON
Crete
r15 140 x 100
140 x 140 Hi-strength
220 x 65
rW22A 140 x 220
r22 220 x 100
rW22 220 x 140
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
stANdArd 600 1050 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4200 LeNGtHs (mm) 900
Clear Span (mm) 750 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3900
Weight (kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0
UDL (kN/m) 48.8* 35.9* 26.3 19.3 15.2 11.8 9.9 6.9 5.1 3.9 3.1 2.5 2.1 1.2
RM (kNm) 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 3600mm
stANdArd 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 LeNGtHs (mm)
Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300
Weight (kg/m) 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9 47.9
UDL (kN/m) 67.5* 67.5* 57.9 52.1 39.2 26.5 18.6 13.8 10.6 8.4 6.7 5.5
RM (kNm) 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 3000mm
stANdArd 600 900 1050 1200 1500 1800 2100 2400 2700 3000LeNGtHs (mm)
Clear Span (mm) 300 600 750 900 1200 1500 1800 2100 2400 2700
Weight (kg/m) 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0
UDL (kN/m) 36.4* 36.4* 23.7 17.0 9.8 6.3 4.4
RM (kNm) 1.9 1.9 1.9 1.9 1.9 1.9 1.9
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
stANdArd 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200LeNGtHs (mm)
Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900
Weight (kg/m) 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4
UDL (kN/m) 83.1* 83.1* 68.2 63.3 58.4 47.0 33.9 25.6 20.0 16.1 13.2 11.0 9.3 7.3
RM (kNm) 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
stANdArd 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200LeNGtHs (mm)
Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900
Weight (kg/m) 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7 51.7
UDL (kN/m) 49.0* 49.0* 26.0 19.3 14.8 9.4 6.5 4.7 3.5 2.7 2.1 1.6 1.3 1.0
RM (kNm) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
*UDL is restricted by shearMinimum manufactured length is 600mm Maximum manufactured length is 4200mm
stANdArd 600 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200LeNGtHs (mm)
Clear Span (mm) 300 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900
Weight (kg/m) 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4
UDL (kN/m) 76.0* 76.0* 54.9 50.8 46.7 30.9 22.0 16.4 12.7 10.2 8.3 6.9 5.8 4.2
RM (kNm) 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
100
140
220
100
140
140
140
220
220
65
220
140
300600
39BACK… to ‘Contents’ page
Arc
H FO
rmers
Arch Length rise (mm) (mm) Arch reference
475 75 475 x SL75 Arch Former
625 75 625 x SL75 Arch Former
685 75 685 x SL75 Arch Former
750 75 750 x SL75 Arch Former
825 75 825 x SL75 Arch Former
860 75 860 x SL75 Arch Former
925 75 925 x SL75 Arch Former
1025 75 1025 x SL75 Arch Former
1050 75 1050 x SL75 Arch Former
1085 75 1085 x SL75 Arch Former
1135 75 1135 x SL75 Arch Former
1225 75 1225 x SL75 Arch Former
1325 75 1325 x SL75 Arch Former
1350 75 1350 x SL75 Arch Former
1375 75 1375 x SL75 Arch Former
1485 75 1485 x SL75 Arch Former
1525 75 1525 x SL75 Arch Former
1585 75 1585 x SL75 Arch Former
1625 75 1625 x SL75 Arch Former
1675 75 1675 x SL75 Arch Former
1700 75 1700 x SL75 Arch Former
1785 75 1785 x SL75 Arch Former
2035 75 2035 x SL75 Arch Former
2125 75 2125 x SL75 Arch Former
2250 75 2250 x SL75 Arch Former
Arch Length rise (mm) (mm) Arch reference
1585 150 1585 x SL150 Arch Former
1916 150 1916 x SL150 Arch Former
1950 150 1950 x SL150 Arch Former
1975 150 1975 x SL150 Arch Former
2035 150 2035 x SL150 Arch Former
2125 150 2125 x SL150 Arch Former
2250 150 2250 x SL150 Arch Former
2325 150 2325 x SL150 Arch Former
2425 150 2425 x SL150 Arch Former
2530 150 2530 x SL150 Arch Former
2575 150 2575 x SL150 Arch Former
2596 150 2596 x SL150 Arch Former
2725 150 2725 x SL150 Arch Former
ArcH FOrmersAPPLicATiOnWhite uPVC Arch Formers are used over openings in external walls and provide a low cost solution to help form low rise (75mm and 150mm) brick arches. The facia is formed from uPVC which is bonded to high density EPS.
40bAcK… to ‘Contents’ page
sPeciA
LsAPPLicATiOnStressline Special Lintels are designed and manufactured to suit the most innovative of window designs and styles including: • Semi-circular arch• Segmental arch• Parabolic arch• Gothic arch• Venetian arch • Apex lintel• Corner lintel • Splayed bay lintel • Square bay lintels
insTALLATiOn nOTes See page 46 for general installation notes.
ADvAnTAGes• Easy to install and suitable for a variety of
applications• Galvanised coating ensures durability/longevity• Built-in plaster key – perforated base plate to
inner fl ange• Excellent thermal effi ciency of no more than
0.32 W/mK for cavity wall construction• Available for solid wall construction• Corner lintels and bay lintels can be supplied
with corner posts
inFOrmATiOn reQUiremenTsTo enable us to provide a quick and cost effective service, please provide our Technical Offi ce with all the relevant information regarding: wall construction (inner leaf, cavity width, outer leaf), structural opening (clear span), arch rise or radius, loadings supported by the lintel (i.e. masonry loads, fl oor/roof loads).
Please refer to forms overleaf.
% if in doubt please contact our technical department on
0870 7503167
sPeciALs
41bAcK… to ‘Contents’ page
sPeciA
Ls
semi-circULAr ArcH LinTeL
A
R
BB
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Clear span A Outer leaf Inside onlymm mm
Rise R Cavity width Both sidesmm mm
End bearing B Inner leaf Nonemm mm
GOTHic ArcH LinTeL LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Clear span A Outer leaf Inside onlymm mm
Rise R Cavity width Both sidesmm mm
End bearing B Inner leaf Nonemm mm
A
R
B B
PArAbOLic ArcH LinTeL LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Clear span A Outer leaf Inside onlymm mm
Rise R Cavity width Both sidesmm mm
End bearing B Inner leaf Nonemm mm
A
R
B B
seGmenTAL ArcH LinTeL LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Clear span A Outer leaf Inside onlymm mm
Rise R Cavity width Both sidesmm mm
End bearing B Inner leaf Nonemm mm
A
R
BB
42bAcK… to ‘Contents’ page
sPeciA
Ls
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Span A Outer leaf Inside onlymm mm
Span B Cavity width Both sidesmm mm
Span C
Angle X
Inner leaf Nonemm
º
mm
sPLAYeD bAY LinTeL
B
CA
X°
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Span A Outer leaf Inside onlymm mm
Span B Cavity width Both sidesmm mm
Span C Inner leaf Nonemm mm
sQUAre bAY LinTeL
B
CA
90 °Do not allow for bearing. This will be added at design stage
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Span A Outer leaf Inside onlymm mm
Span B Cavity width Both sidesmm mm
Inner leaf Nonemm
cOrner LinTeL
A
90°
B
Do not allow for bearing. This will be added at design stage
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Clear Span A Outer leaf Inside onlymm mm
Rise R Cavity width Both sidesmm mm
End bearing B
Angle X
Inner leaf Nonemm
º
mm
APeX LinTeL
A
R
B
x°
B
LinTeL DimensiOns WALL cOnsTrUcTiOn PLAsTer KeY reQUiremenTs(please tick)
Overall Clear Span A1 Outer leaf Inside onlymm mm
Arch Span A2 Cavity width Both sidesmm mm
Rise R
End bearing B
Inner leaf Nonemm
mm
mm
veneTiAn ArcH LinTeL
R
B Overall Clear Span A1
Arch Span A2
B
43bAcK… to ‘Contents’ page
APPLicATiOnPadstones are generally specified by engineers and architects to help spread heavy point loads across the block or brick walls.
cOmPressive sTrenGTHStressline padstones are manufactured in a variety of sections and lengths with a standard concrete strength of 40 N/mm². Other concrete strengths can be achieved on application. All padstones may be used in any orientation.
FinisHesStressline padstones are made from wet cast concrete in steel pan moulds providing a smooth finish.
For longer lengths we can provide a reinforced concrete unit with a concrete strength of 50N/mm².
% if in doubt please contact our technical department on
0870 7503167
Length (mm) Height (mm) Width (mm) Weight (kg) Part number
300 140 102 10 CPAD141030
215 140 215 16 CPAD142121
215 215 102 11 CPAD211021
440 140 102 14 CPAD141044
440 140 215 32 CPAD142144
440 215 102 23 CPAD211044
215 140 102 7 CPAD141021
300 215 102 16 CPAD211030
440 215 190 42 CPAD211944
PADsTOnes
PAD
sTOn
es
44bAcK… to ‘Contents’ page
beAm & bLOcK FLOOrinG• Prestressed Flooring• ‘I’ Beam Design• Various Sections• End Slips
225 deep beam and thermal flooring options available.
PrecAsT secTiOns• Stair Flights• Landings• Balconies• Wall Panels• Free Standing Retaining Walls
Design and installation service option available
HOLLOWcOre FLOOrinG• Prestressed Concrete• Spans in excess of 9m• 150mm & 200mm
Design and installation service option available
cOncreTe FencinG AnD WALLinG PrODUcTs• Slotted Posts• Gravel Boards• Support Posts• Morticed and Recessed Posts• Chain Link & Cranked Top Posts• Screed Rails and Bollards• Pier Caps• Copings
Wet cast and Light Weight variants Available
OTHer sTressLine PrODUcTsO
THer sTressLin
e PrOD
Uc
Ts
45bAcK… to ‘Contents’ page
TECH
NIC
AL – STEEL
MATERIAL SPECIFICATIONStressline standard galvanised steel lintels are manufactured from DX51D grade steel to BS EN 10327: 2004, with a zinc coating type Z600, giving a minimum zinc coating of 600g/m² including both sides. All cut edges are treated with corrosion resistant paint. RS and RSC lintels are manufactured from structural steel plate of grade S275 to BS EN 10025-2: 2004.
INSULATIONLintels used in external walls are fully insulated with expanded polystyrene.
QUALITYStressline products are manufactured to the highest quality, under strict control, and comply with all relevant British
Standards. We are continually assessed by the BSI to ensure our quality assurance systems comply with BS EN ISO 9001: 2008.
COSHHProducts are considered non-hazardous to health under normal use. Material data sheets are available from our technical department upon request.
STRUCTURAL PERFORMANCEThe loadings published in the load-span tables were achieved in accordance with BS EN 845-2: 2003 and tested in accordance with BS EN 846-9: 2000. Stated fi gures represent the Total Serviceable Uniform Distributed Load (UDL) in kN.
‘CXHD’ and ‘CH’ type lintels have been tested compositely in accordance with BS EN 846-9: 2000 with the surrounding masonry built in accordance with BS 5628. The structural performance of our lintels is supported by continuous in-house testing.
Load Ratios are always expressed as inner leaf to outer leaf: 1:1 – lintels supporting masonry only 3:1 – lintels supporting masonry and timber fl oors 5:1 – lintels supporting concrete fl oors 19:1 – lintels for eaves applications
RECOMMENDATIONS FOR INSTALLATION • Minimum recommended bearing length is
150mm. The lintel should be bedded on mortar and levelled both along the lintel and across its width. Full bricks, blocks or padstones should be used as bearing areas. Do not bear lintels onto cut blocks!
• Prior to installation, the lintel should be examined carefully for any defects or signs of damage.
• All external wall lintels MUST be installed with a fl exible damp proof course (DPC) or cavity tray.
In the case of cavity walls the cavity tray should extend not less than 50mm beyond the cavity return.
• Inner and outer leaves supported by the lintels should be raised together to avoid excessive eccentricity of loading.
• Masonry must not overhang any fl ange by more than 25mm.
• Masonry above the lintel should be allowed to cure before applying fl oor or roof loads.
• Composite lintels (i.e. ‘CXHD’, ‘CH’ and ‘RSC’) should be adequately propped during construction, at maximum centres of 1.2 metres. The props should not be removed until the mortar has cured. Ensure that the composite part of the lintel (channel) is fully fi lled with well-jointed masonry and allowed to cure.
Additional recommendations for lintels supporting concrete fl oor units• Check that the correct lintel has been installed.• Avoid shock loading of lintels during the
installation of concrete fl oor units and any sideways loading while being fi tted into position. Precast fl ooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports.
If you are in doubt as to the structural performance or suitability of a lintel then please contact our Technical department before ordering/installation.
☎ If in doubt please contact our technical department on
0870 7503167or [email protected]
The Stressline technical support desk offers free technical advice to stockists, engineers, architects, builders and private individuals from 8.00 a.m. to 5.00 p.m. Monday to Friday.
We offer a free scheduling service providing clear and concise schedules based on your working drawings (plans, elevations, sections, fl oor/roof layout, etc.). Structural calculations for local authority can be provided upon request to support our specifi cation.
We can design and manufacture ‘special’ lintels to suit a variety of innovative opening shapes and cavity wall constructions. State of the art production facilities and design expertise enable us to take an architectural idea and turn it into a functioning product.
TECHNICAL – STEEL LINTELS
46BACK… to ‘Contents’ page
sTrUcTUrAL PerFOrmAnceStressline prestressed concrete lintels are designed in accordance with BS 8110-1: 1997 with a concrete strength of 50 N/mm² or 60 N/mm² and utilizing strands to BS 5896. Lintels are manufactured to BS EN 845-2: 2003. Materials used in the manufacture of Stressline prestressed concrete lintels comply with BS EN 206-1: 2000 and BS 8500.
Lintels offer a minimum of ½ hour fi re resistance in accordance with Table 4.3 from BS 8110-2: 1985. This can be increased by additional protection as specifi ed in clause 4.2.4 from BS 8110-2: 1985.
The structural performance of our lintels is supported by continuous in-house testing.
imPOrTAnT nOTesThe 100 x 65, R15, R22 and RW22 lintels are ‘Universal’, which means that they can be turned either way round to suit the wall construction.
In accordance with good practice, 100 x 70 Hi-Strength, 140 x 65, 220 x 65 and 140 x 140 Hi-Strength lintels are stamped ‘TOP’ and this surface must be kept at uppermost at all times. Our 100 x 140 Hi-Strength lintels have a groove along the top to enable them to be differentiated from R15 ‘Universal’ lintels. In addition to this, the 100 x 70 Hi-Strength and 100 x 140 Hi-Strength lintels are sprayed with blue paint across the section at one end to avoid confusion with similar sections: 100 x 65 and R15 respectively.
QUALiTYStressline products are manufactured under strict quality control and comply with all relevant British Standards. We are
continually assessed by the BSI to ensure our quality assurance systems comply with BS EN ISO 9001: 2008.
cOsHHProducts are considered non-hazardous to health under normal use. Material data sheets are available from our technical department upon request.
recOmmenDATiOns FOr insTALLATiOn• The lintel should be bedded on mortar and
levelled both along the lintel and across its width. Full bricks, blocks or padstones should be used as bearing areas. Do NOT bear lintels onto cut blocks!
• recommended minimum bearings are:– 100mm both ends in structural openings up
to 1000mm– 150mm both ends in structural openings up
to 3000mm– 200mm both ends in structural openings greater
than 3000mm
This does not discharge the installer’s responsibility to ensure that the bearing pressures of the masonry are not exceeded.• Prior to installation, the lintel should be examined
carefully for any defects or signs of damage.• All external wall lintels MUST be installed with a
fl exible damp proof course (DPC).• Masonry must not overhang the lintel by more
than 25mm.
LiFTinG AnD sTAcKinG• When using mechanical plant, only 1 layer of units
should be lifted at a time and supported at or near ends.
• Units should be handled carefully as they will not withstand heavy blows, dropping or reverse bending.
• Lifting should be carried out with regard to weather conditions, particularly wind, adequate lifting capacity and lengths of chains.
• No lifting should be carried out over work areas.• Load weight should be checked prior to lifting.• Stacking should be the right way up on suitable
fi rm, level ground.• The bearers should be near to the ends and
vertically over each other.• Examine units (and infi ll blocks) for cracks and
damage and if present do not use.
Additional recommendations for lintels supporting concrete fl oor units• Check that the correct lintel has been installed.• Avoid shock loading of lintels during the
installation of concrete fl oor units and any sideways loading while being fi tted into position. Precast fl ooring units should be laid on a mortar bed across the whole wall width and should not be dragged over supports.
If you are in doubt as to the structural performance or suitability of a lintel then please contact our Technical department before ordering/installation.
% if in doubt please contact our technical department on
0870 7503167or [email protected]
Stressline Technical support desk offers free technical advice to stockist, engineers, architect, builders and private individuals from 8.00 a.m. to 5.00 p.m Monday to Friday.
We offer free, clear and concise scheduling service based on your working drawings (plans, elevations, sections, fl oor/roof layout, etc.). If required, we can schedule and deliver lintels in house plots with an easy referencing system to ensure that the correct lintel is used in the chosen location. Structural calculations for local authority can be provided upon request to support our specifi cation.