LIQUID LEAK SENSORS LIQUID LEAK SENSORS
Transcript
Page 1: LIQUID LEAK SENSORS · LIQUID LEAK SENSORS Semiconductor production line Applications Medical equipment Printing press e.g. MRI Chemical plant Industrial robot Series General specifications

L I Q U I D L E A K S E N S O R SL I Q U I D L E A K S E N S O R S

Page 2: LIQUID LEAK SENSORS · LIQUID LEAK SENSORS Semiconductor production line Applications Medical equipment Printing press e.g. MRI Chemical plant Industrial robot Series General specifications

LeakNormal condition (No leak)

Detection principle

Problem Solution

Optical liquid leak sensors are equipped with a photoreflector. The light from the LED reflects off of the prism into the light detector. When the leakage makes contact with the prism, some portion of the light is transmitted toward the leakage. The light detector recognizes the reduced brightness of the light and sends a signal from the sensor that there is a leak.

When used in a high ambient light environment (especially when the floor is a mirror-like surface), the amount of light received by the light detector will increase, leading to false detection. A typical leak sensor requires a plate below the photoreflector to control excessive light disturbance. However, if the amount of leakage is small, leakage may not be able to get over the plate due to surface tension. Our unique optical design enables the WL10 to detect leakage quickly and accurately without using a plate to control light disturbance.

[ Features ]●Unique optical design for quick and accurate leak detection. ● Easy installation. No reflection control plate or additional amplifying circuits are required. ● Compact (25mm dia., 10.6mm height) ● Compatible with water (PP housing) and corrosive liquids (PFA housing)

In normal condition (no leak), the switch output is ON and the LED l ight is GREEN. When leak is detected, the switch output turns OFF and the LED light turns RED.

LED PD

Air

PHOTOREFLECTOR

prism

Leakage

Typical leak sensor

prism

Shade plateShade plate

LED PDPHOTOREFLECTOR

Air

Leakage

BadBadWL10

prism

LED PD

Air

Leakage

GoodGoodPHOTOREFLECTOR

Darkening maskDarkening mask

Air

LED PDPHOTOREFLECTOR

prism

Leakage

prismAir

LED PDPHOTOREFLECTOR

L I Q U I D L E A K S E N S O R SL I Q U I D L E A K S E N S O R S

Page 3: LIQUID LEAK SENSORS · LIQUID LEAK SENSORS Semiconductor production line Applications Medical equipment Printing press e.g. MRI Chemical plant Industrial robot Series General specifications

●Semiconductor production line

Applications

●Printing press●Medical equipmente.g. MRI

●Chemical plant ●Industrial robot

SeriesGeneral specificationsOperating temp. rangeOperating humidityStorage temp.Pressure mediumMaterial of housingNet weightPowerSupply voltageConsumption currentOutputSwitch output interface

Switching capacity

Residual voltage

Leak indication

PNPVoltage endurance: 24 VDC

Sourced current: 50 mA maximum(Over current protection)

2.0 V maximum

NPNVoltage endurance: 30 VDCSink current: 50 mA maximum(Over current protection)

1.0 V maximum

WL10

-10 ~ 60℃35 ~ 85%RH(No condensation)

-20 ~ 70℃(Atmospheric pressure, humidity 65%RH maximum)Water (PP) / Corrosive fluids compatible with PFA

PP / PFAApprox. 30 g (WL10- *P-2), Approx. 50 g (WL10- *P-4, WL10- * F-2), Approx. 80 g (WL10- *F-4)

12 ~ 24 VDC ±10 %10 mA maximum (Except open collector output)

Normal condition: Switch ON, Green LED ON Leak detection: Switch OFF, Red LED ON

Specifications

Test itemVibrationShockProtection gradeEMC

Specification Test conditions

Environmental Characteristics

10 ~ 500 Hz, 1.5 mm maximum / 98.1 m / S2, 3 directions for 2 hours each490 m/s2, 3 directions for 3 times each IP67CE marking

Meets standard specifications

SeriesSwitch output interfaceMaterial of housing

Cable length

PNP NPN

WL10

List of Model Numbers

PPWL10-NP-2 WL10-NP-4*

PFAWL10-NF-2 WL10-NF-4*

PPWL10-PP-2 WL10-PP-4*

PFAWL10-PF-2 WL10-PF-4*

Page 4: LIQUID LEAK SENSORS · LIQUID LEAK SENSORS Semiconductor production line Applications Medical equipment Printing press e.g. MRI Chemical plant Industrial robot Series General specifications

WV201906E1500WV201906E1500

Internal Electrical Schematics

2618

16.5

7.6

9.9

5 8.1 10.6

L

25

φ

2 ‒ 4.5

φ

Indicator

Detecting element

PFA heat shrink tubing

4.4φPFA tube

L

2 ‒ 4.5

5 8.1 10.6

9.9

10.2 50.5

7.616.5

18 26

3-core cable( 2.9)φ

25

φ

φ

AWG28ULNo.20276

Indicator

Detecting element

Outline Dimensions (Unit: mm)

10.250.5

3-core cable( 2.9)φAWG28ULNo.20276

GreenRed

Common

Power⊕

S.Output

IndicatorGreenRed

Common

Power⊕

S.Output

Indicator

●NPN ●PNP

●WL10- *P-* (Material of housing - PP)

●WL10- *F-* (Material of housing - PFA)


Recommended