TG-F771-5E SEP., 2003
ORIFLO
GENERAL
O series ORIFLO METER is a By-pass Orifice type flowmeter.
Small sized variable flowmeter is installed onto measuring tube part
in which an orifice plate for by-pass flow is integrated.
Three different process connections,i.e., "SCREW", "FLANGE" and
"WAFER", are available for Selection.
An isolation valve is available between measuring tube and indica-
tor for indicator maintenance work even during process operation.
This eliminates the necessity of by-pass piping for maintenance pur-
pose and saves total piping cost.
In addition to standard material of STEEL version, Stainless steel
and PVC versions to cover corrosive fluids are available.
Alarm contacts are available as option. (O-780 series)
FEATURES
❏ LOW COST / HIGH PERFORMANCE
Thanks to unique orifice by-pass system, total instrumentation
cost can be saved especially for medium and large sized piping
measurement.
❏ COMPACT DESIGN
Small sized indicator saves space in plants.
❏ EASY INSTALLATION
"SCREW", "FLANGE" and "WAFER" are ready to meet field re-
quirements.
By-pass piping for maintenance purpose can be skipped by using
isolation valve.
❏ FOR ALL FLOW DIRECTIONS
BOTTOM TO TOP, TOP TO BOTTOM, LEFT TO RIGHT, RIGHT
TO LEFT.
ORIFLO is applicable for all possible flow directions. Change of
such flow direction is possible in field even after installation.
❏ ALARM CONTACT
Besides local flow rate indication, alarm contact (s) are available.
ORIFLO can be used as FLOWSWITCH.
❏ EASY MAINTENANCE
Simple design and limited number of parts saves maintenance
work.
❏ HIGH ANTI CORROSIVE CAPABILITY VERSION
Stainless steel and PVC versions are available for corrosive fluid
application.
COST EFECTIVE FLOW MEASUREMENT FORLIQUIDS AND GASES
INTEGRATED ORIFICE FLOWMETERS
MAIN APPLICATIONS
❏ Hot and cool water as well as air flow measurement at Air condi-
tioning
❏ Medium and large line measurement at General process
❏ Cooling water lines
❏ Water treatment process
❏ Pure and Ultra pure water production facilities process
❏ Testing of Fire fighting pumps
❏ Testing of blowers
❏ Others
CONTENTS
P1 GENERAL
FEATURES
MAIN APPLICATIONSP2 OPERATION PRINCIPLE
CONSTRUCTION
P3 MATERIAL CONSTRUCTIONMODEL CODE
P4 STANDARD SPECIFICATION
P5~6 SCALE RANGEP7 NO SERIES STANDARDIZED VERSION
P8~12 DIMENSIONS
P13 O-190 SERIES DIAL INDICATOR TYPEP14 SUGGESTIONS
INSTALLATION ACCESSORIES
P15 ORDERING INFORMATION
ORIFLO
2 TOKYO KEISO CO., LTD. TG-F771-5E
Main pipe
Processpiping
Orifice plate
Return tube
ValveHandle
By-pass return
By-pass piping
Isolation valve
Tapered tube(Graduated)
Float
Strainer
By-pass orifice
As shown in the figure, differential pressure is produced across the
Main orifice plate by flow velocity which corresponds to flow rate.
A small sized flowmeter (Variable area flowmeter) is mounted onto
this differential pressure production unit. By this arrangement, the
flow rate through the flowmeter corresponds to the flow rate through
the main piping.
Thus, scale range for main piping can be engraved onto the small
sized flowmeter and the flow rate through the main piping is indicated
by the position of float of the flowmeter.
Normally, an isolation valve is provided between the measuring tube
and the indicator for the purpose of indicator maintenance with no in-
terference of process operation. (This valve is for maintenance/ iso-
lation purpose and not for flow control purpose.)
A magnet piece is buried into the float for Alarm version which at-
tracts reed switch for alarm contact output. The setting point of alarm
is adjustable by shifting the location of reed switch.
a. Indicatorassembly
c. Main pipeb. Isolationvalve
OPERATION PRINCIPLE
CONSTRUCTION
ORIFLO consists of : a. lndicator
b. lsolation valve
c. Main pipe
The figure is an extended view of metallic material version.
(It would differ in case of PVC version.)
ORIFLO
TOKYO KEISO CO., LTD. 3TG-F771-5E
MATERIAL CONSTRUCTION
Different materials are available for measuring tube, isolation valve, indicator and sealings to cover various fluids
as per the following table ;
MODEL CODE
0 –
1678
– – –
SFW
NCB
– – – – –
– –
00000
45
11223
50
05052
00
– – – – – –
123456
MODE CODE
FUNCTION *1
FLOW DIRECTION
PROCESS CONNECTION
ISOLATION VALVE *2
LINE SIZE
MATERIAL CODE
DESCRIPTION
LOCAL INDICATION ONLYLOCAL INDICATION + ALARM CONTACTLOCAL INDICATION + OPITICAL ALARM UNIT (OLD MODEL O-76 )BOTTOM➝TOPLEFT➝RIGHTRIGHT➝LEFTTOP➝BOTTOMSCREW CONNECTION (10 mm~100mm)FLANGE CONNECTION (10 mm~)WAFER CONNECTION (10 mm~)NOT PROVIDEDPROVIDEDINDICATOR SEPARATION VERSION10mm15mm20mm25mm32mm
450mm500mmMATERIAL CLASS 1 (Steel)MATERIAL CLASS 2 (304SS)MATERIAL CLASS 3 (316SS)MATERIAL CLASS 4 (PVC)MATERIAL CLASS 5 (HT.PVC)SPECIAL
– – –187868
~ ~
*1: O-190 Dial indication version available. Refer to page 13 for details.*2: Ball valves are provided for indicator separation version (O- 8 - B). Refet to page 11 for details.
Main pipe
Screw connection
Flange connection
Wafer connection
Orifice plate
Isolation valve body / shaft
Indicator body
Tapered tube
FloatFor Iiquids
For Gases
Cover
Sealing
Material Class 1
SCS14/FCD400 *1
SGP/SS400
SS400/SCS14 *6
SUS304
SCS14/SUS304
SCS14
Pyrex glass
SUS316
Glass
SUS304/ABS
NBR
FPM
Material Class 2
SCS14/SUS304 *2
SUS304
SUS304/SCS14 *6
SUS304
SCS14/SUS304
SCS14
Pyrex glass
SUS316
Glass
SUS304/ABS
NBR
FPM
Material Class 3
SCS14/SUS316 *3
SUS316
SUS316/SCS14 *6
SUS316
SCS14/SUS316
SCS14
Pyrex glass
SUS316
Glass
SUS304/ABS
NBR
FPM
Material Class 4
PVC
PVC
PVC
PVC
HT.PVC/PP
HT.PVC
Pyrex glass *5
PVC *7
Glass
–*4
NBR
FPM
Material Class 5
HT.PVC
HT.PVC
HT.PVC
HT.PVC
HT.PVC/PP
HT.PVC
Pyrex glass
HT.PVC
Glass
–*4
NBR
FPM
Part description
*1: SCS14 for 10mm~25mm*2: SUS304 for 65mm~100mm*3: SUS316 for 65mm~100mm*4: Clear PVC cover available on request.*5: PVC (Max. Press. 0.6MPa) and Acryl (Max. Press. 0.4MPa, Max. Temp. 40°C) tapered tubes are also available.*6: SCS14 for 25mm, 40mm~150mm (JIS10K)
Abbriviation of material PP : Polypropylene NBR : Nitrile Butadiene Rubber FPM : Fluoro rubber HT.PVC : High temp. PVC
ORIFLO
4 TOKYO KEISO CO., LTD. TG-F771-5E
STANDARD SPECIFICATION
Measuring fluid :
Liquids (upto 3 mPa.s viscosity)
Gases (Not suitable for opaque liquids, slurries and steam)
Available sizes :
Std. 10mm(3/8")~300mm(12") Option 350mm(14")~500mm(20")
Special Larger than above on request
Process connection : Screw connection
Std. JIS RC thread
Opt. NPT threadSize availability
10mm(3/8")~100mm(4")
(10mm~50mm for PVC, HT.PVC versions) Flange connection
Std. JIS10KFF, JIS10KRF
Opt. ANSI 150#, JPI 150#, OthersSize availability 10mm(3/8")~
Wafer connection
Std. For JIS10K flangesOpt. For other flanges
Size availability 10mm(3/8")~
Max. fluid temp.
Material
Metallic indicators
PVC indicators
HT.PVC indicators
NBR seal
FPM seal
Stl. valve shaf
Max. fluid temp.
120°C*
60°C
80°C
80°C
120°C
120°C*
Max. Press : 1.0MPa (10kg/cm2G)
0.6MPa (6kg/cm2G) for PVC, HT.PVCversions
Range ability : Std. 10: 2
Different range ability applicable forspecial design products.
Indication accuracy : ±3% F.S.
(High accuracy special calibration onrequest)
Standard Differential pressure :
Other special Differential pressure design available onrequest. Consult factory for details.
Standard painting : Munsell 7.5BG4/1.5PVC part will not be painted.
Alarm function : 1 or 2 point alarm can be additionallyprovided.
Type of contact : Reed switch (SPST)Termination : M3.5 screw terminalTerminal connection :
1 point alarm : 1–32 point alarm : 1–3, 2–3
Contact capacity :AC10VA(Max. voltage 125V, Max. current 0.25A)DC10W(Max. voltage 100V, Max. current 0.25A)Use RD-1000 type Relay Driver if larger contactcapacity is required.(Separete TECHNICAL GUIDANCE available onrequest)
Reset Span : Max. 20% F.S.
Function
Local indication
Local indication
Alarm
+
Indicator materialDP (kPa)
For liquids For gases
Matellic material
Matellic material
PVC, HT.PVC
PVC, HT.PVC
15
15
15
20 20
20
5
5
REED SW TERMINAL(SELF RETENTIONING TYPE)
In case of lamp load, inductive load andelectric motor load, the surge current maybe induced. Provide the suitable protectionsuch as CR, surge suppression, relays etc.
ORIFLO
TOKYO KEISO CO., LTD. 5TG-F771-5E
Consult factory for other scale ranges, if required.
Above table is indicated based on water flow measurement.(Density 1.0g/cm3 Viscosity 1.0mPa.s) When the fluidSpecific gravity is other than 1.0, conduct conversioncalculation by the following formula, and refer to the table :
The calculation of figures in the above flow range table hasbeen made on the premises that SGP, a JIS code name fora carbon steel pipe for ordinary piping, had been used formain pipes. ln case of pipes other than SGP, multiply theabove liquid quantity by (the inner diameter of a pipe used ÷the inner diameter of a SGP pipe)2.
SCALE RANGE
●FOR LIQUID MEASUREMENT
Float material
Stainless steel (Local indicator)
Stainless steel (With alarm)
PVC (All types)
Density of float
7.9g/cm3
7.3g/cm3
3.0g/cm3
QW = Q ×
QW : Water converted range
Q : Flow range for actual liquid
: Density of actual Liquid
: Density of float
γo
γo (γ f – 1)
(γ f – γo)
γ f
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
0.14 ~ 0.5
0.18 ~ 1.1
0.30 ~ 2.4
0.45 ~ 4.0
0.70 ~ 6.5
1.0 ~ 9.0
1.8 ~ 15
3.5 ~ 24
4.2 ~ 32
7 ~ 55
12 ~ 80
16 ~ 120
35 ~ 200
50 ~ 300
65 ~ 450
85 ~ 550
120 ~ 700
160 ~ 1000
350 ~ 1200
0.15 ~ 0.6
0.20 ~ 1.4
0.35 ~ 3.0
0.50 ~ 5.0
0.80 ~ 8.0
1.2 ~ 11
2 ~ 18
4 ~ 30
5 ~ 40
8 ~ 70
15 ~ 100
20 ~ 150
40 ~ 250
60 ~ 400
80 ~ 550
100 ~ 700
150 ~ 900
200 ~ 1200
400 ~ 1500
0.30 ~ 1.0
0.40 ~ 2.4
0.65 ~ 5.0
0.90 ~ 8.5
1.5 ~ 14
2.5 ~ 19
4 ~ 30
8 ~ 50
10 ~ 70
15 ~ 120
30 ~ 180
40 ~ 250
80 ~ 450
100 ~ 700
140 ~ 1000
180 ~ 1300
250 ~ 1600
350 ~ 2200
700 ~ 2600
SIZEFULL SCALE RANGE m3/h (Water, Density 1.0g/cm3, 1.0mPa.s viscosity)
DP 10kPa *1 DP 15kPa *2 DP 50kPa *3
*1: Range ability 10 : 2.5*2: Range ability 10 : 2*3: Range ability 10 : 2 (10 : 1.5 on request)
ORIFLO
6 TOKYO KEISO CO., LTD. TG-F771-5E
-10 -12 -15 -20 -25 -30 -35 -40 -45 -50 -55 -60 -65 -70 -75 -80 -85 -90 -95
(0.5) (0.5) (0.5) (0.5) (1.0) (1.0) (1.0) (1.0) (1.0) (2.0) (2.0) (2.0) (2.0) (2.0) (5.0) (5.0) (5.0) (5.0) (5.0)
10
8
6
4
2
12
9
6
32.4
15
10
5
3
20
15
10
54
40
30
20
108
45
40
30
20
109
25
20
15
10
5
50
40
30
20
10
30
20
10
6
35
30
20
10
7
55
50
40
30
20
11
60
50
40
30
20
12
65
60
50
40
30
20
13
70
50
30
14
90
70
50
30
18
9590
70
50
30
19
7570
50
30
15
80
60
40
1017
8580
60
40
2017
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
2.3 ~ 9.0
3.2 ~ 20
5 ~ 45
8 ~ 80
12 ~ 130
16 ~ 180
25 ~ 290
45 ~ 460
60 ~ 650
100 ~ 1100
150 ~ 1700
210 ~ 2400
380 ~ 4200
550 ~ 6500
900 ~ 9000
1100 ~ 11000
1500 ~ 15000
1800 ~ 19000
2200 ~ 24000
3.5 ~ 12
4.5 ~ 28
7.5 ~ 65
11 ~ 110
18 ~ 180
22 ~ 250
35 ~ 400
65 ~ 650
85 ~ 900
140 ~ 1500
220 ~ 2400
300 ~ 3400
500 ~ 5500
800 ~ 9000
1200 ~ 12000
1600 ~ 16000
2100 ~ 21000
2600 ~ 27000
3200 ~ 33000
4.5 ~ 16
6 ~ 39
10 ~ 90
15 ~ 150
25 ~ 250
32 ~ 340
50 ~ 550
90 ~ 900
120 ~ 1200
200 ~ 2100
300 ~ 3300
400 ~ 4500
750 ~ 8000
1100 ~ 12000
1700 ~ 17000
2200 ~ 22000
2800 ~ 28000
3500 ~ 36000
4200 ~ 45000
SIZEFULL SCALE RANGE m3/h (nor) (Air, 0°C, 1 atm)
DP 5kPa *1 DP 10kPa *2 DP 20kPa *2
*1: Range ability 10 : 2*2: Range ability 10 : 2 (10 : 1.5 on request)
Consult factory for other scale ranges, if required.
Gas measurement versions are all custom made. Thefollowing table is shown by the flow rate of AIR, at 0°C, 1atm. Conduct conversion calculation and refer to the table.
Conversion calculation
The calculation of figures in the above flow range table hasbeen made on the premises that SGP, a JIS code name fora carbon steel pipe for ordinary piping, had been used formain pipes. ln case of pipes other than SGP, multiply theabove liquid quantity by (the inner diameter of a pipe used ÷the inner diameter of a SGP pipe)2.
●FOR GAS MEASUREMENTORIFLO for gas flow measurment will be calibrated and graduated according to customers' individual operating conditionsuch as density, pressure and temperature.Refer to ORDERING INFORMATION on page 15 and specify operating condition.The following table is shown by the air flowrate at 0°C,1 atm. Conversion calculation is required in case actual operating condition differs from this.
Q = Q × Cγ × Ct × CpQ : Converted Air flowQ : Flow rate of Actual GasCγ : Cγ = γ /1.293 (γ=Sp, Wt of the Gas, kg/Nm3)Ct : Ct = (273+t)/273 (t=operating temp., °C)Cp: Cp = 0.1013/(0.1013+p) (p=operating press. MPa)
A
A
●Standard scale graduation
ORIFLO
TOKYO KEISO CO., LTD. 7TG-F771-5E
NO–L
SNSCFNFC
Size
Scale range code
Rc thread, No isolation valveRc thread, Isolation valve providedFlange ended, No isolation valveFlange ended, Isolation valve provided
●MODEL CODE FOR LIQUID MEASUREMENT, Material is same as Class 1 in page 3.
NO–G
SNSCFNFC
Size
Rc thread, No isolation valveRc thread, Isolation valve providedFlange ended, No isolation valveFlange ended, Isolation valve provided
●MODEL CODE FOR GAS MEASUREMENT, Material is same as Class 1 in page 3.
Scale range 2 ~ 10 m3/h (std) 5 ~ 25 m3/h (std) 10 ~ 50 m3/h (std) 20 ~ 100 m3/h (std) 30 ~ 150 m3/h (std)
Size10mm15mm20mm25mm32mm
Model codeNO–G10–NO–G15–NO–G20–NO–G25–NO–G32–
Scale range 40 ~ 200 m3/h (std) 80 ~ 400 m3/h (std)120 ~ 600 m3/h (std) 200 ~ 1000 m3/h (std) 300 ~ 1500 m3/h (std)
Model codeNO–G40–NO–G50–NO–G65–NO–G80–NO–G100–
Size40mm50mm65mm80mm100mm
Scale range table
Calibration condition : Air, 20°C 1 atm
NO SERIES STANDARDIZED VERSION
NO SERIES is the fixed scale range version of O-180 ORIFLO. Available size is 10 mm(3/8")~100mm(4").
Size
10mm
15mm
20mm
25mm
32mm
Model codeNO–L10–02–
04–06–08–
NO–L15–03–05–08–10–15–
NO–L20–15–20–25–30–
NO–L25–20–30–40–50–60–
NO–L32–04–06–08–10–
Scale range 40 ~ 200 L/h 80 ~ 400 120 ~ 600 160 ~ 800 60 ~ 300 L/h 100 ~ 500 160 ~ 800 0.2 ~ 1 m3/h 0.3 ~ 1.5 0.3 ~ 1.5 m3/h 0.4 ~ 2 0.5 ~ 2.5 0.6 ~ 3 0.4 ~ 2 m3/h 0.6 ~ 3 0.8 ~ 4 1 ~ 5 1.2 ~ 6 0.8 ~ 4 m3/h 1.2 ~ 6 1.6 ~ 8 2 ~ 10
Scale range 1 ~ 5 m3/h 1.6 ~ 8 2 ~ 10 3 ~ 15 2 ~ 10 m3/h 3 ~ 15 4 ~ 20 5 ~ 25 3 ~ 15 m3/h 4 ~ 20 6 ~ 30 8 ~ 40 6 ~ 30 m3/h 8 ~ 40 10 ~ 50 8 ~ 40 m3/h 10 ~ 50 12 ~ 60 16 ~ 80 20 ~ 100
Size
40mm
50mm
65mm
80mm
100mm
Model codeNO–L40–05–
08–10–15–
NO–L50–10–15–20–25–
NO–L65–15–20–30–40–
NO–L80–30–40–50–
NO–L100–40–50–60–80–
100–
Scale range table
Calibration condition : Water, Sp. Gr. 1.0, 1.0 mPa.s viscosity
ORIFLO
8 TOKYO KEISO CO., LTD. TG-F771-5E
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
74
85
90
100
110
120
70
70
70
70
74
85
90
–
–
–
105
105
110
110
120
120
130
–
–
–
1.5
1.6
1.7
1.8
2.0
2.1
2.6
–
–
–
2.0
2.2
2.3
3.0
3.5
5.0
SIZEMain pipe FCD400 Main pipe SCS14
120
120
130
140
145
160
L *A Weight(kg) L *A Weight(kg)
* A is reduced by 40mm in case lsolation valve is NOT provided. Weight of isolation valve is 0.4kg
65mm
80mm
100mm
120
120
160
175
185
200
4.0
4.3
7.5
SIZE L Weight (kg)*A
* A is reduced by 40mm in case lsolation valve is NOT provided. Weight of isolation valve is 0.4kg
10mm
15mm
20mm
25mm
32mm
40mm
50mm
75
75
75
75
85
85
90
145
145
145
145
150
155
160
1.1
1.1
1.1
1.1
1.2
1.2
1.2
SIZE L *A Weight (kg)
* A is reduced by 45mm in case lsolation valve is NOT provided. Weight of isolation valve is 0.2kg
(1) MATERIAL CLASS
●SCREW CONNECTION TYPE O-18 -SC- -
1 (FCD400) 32mm~100mm,
2 3 (SCS14) 10mm~50mm
(2) MATERIAL CLASS 2 3 (SUS304, SUS316) 65mm~100mm
EXTERNAL DIMENSION
(3) MATERIAL CLASS (PVC, HT.PVC) 10mm~50mm4 5
ORIFLO
TOKYO KEISO CO., LTD. 9TG-F771-5E
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
600mm
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
3.2
3.6
4.2
5.4
6.7
7.1
8.5
11.4
12
15.5
20
27
35
50
61
74
93
115
130
170
140
145
145
150
155
155
165
170
175
190
200
215
240
265
290
310
335
360
390
440
SIZEL *1A *2Weigh (kg)
Main pipe(SGP,SUS304,SUS316)
1 2 3
*1: A is reduced 40mm in case isolation valve is NOT provided.*2: In case flange rating JIS10K Weight of isolation valve is 0.4kg
MATERIAL CLASS
●FLANGE CONNECTION TYPE
O-18 -FC- -
MATERIAL CLASS
Special design with L dimension of 200mm (10A~80A) and 300mm (100A~600A)available on request, Contact Tokyo Keiso for details.
1 2 3
4 5 540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
540
–
–
–
–
1.1
1.2
1.3
1.5
1.9
1.9
2.3
2.7
3.1
4.1
5.5
8.0
9.5
14.5
20
20
–
–
–
–
125
125
130
130
135
140
145
155
160
175
185
200
225
250
275
300
–
–
–
–
Main pipe(PVC,HT.PVC)
4 5
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
600mm
SIZEL *1A *2Weigh (kg)
*1: A is reduced 45mm in case isolation valve is NOT provided.*2: In case flange rating JIS10K Weight of isolation valve is 0.2kg
ORIFLO
10 TOKYO KEISO CO., LTD. TG-F771-5E
(2) MATERIAL CLASS (PVC, HT.PVC)4 5
(1) MATERIAL CLASS (SS400, SUS304, SUS316, SCS14)
●WAFER CONNECTION TYPE
O- 8 -W - -
1 2 3
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
600mm
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
65
65
65
65
65
2.5
2.7
2.8
2.0
3.6
2.5
2.8
3.1
3.3
3.8
8.2
10
13
18
20
25
34
40
47
58
160
160
165
175
175
180
190
200
205
215
230
245
270
300
320
345
375
405
430
485
SIZE L *A
* A and weight are for JIS10K flange installation and is reduced by 40mm in case isolation valve is NOT provided. Weight of isolation valve is 0.4kg
Weight (kg)
10mm
15mm
20mm
25mm
32mm
40mm
50mm
65mm
80mm
100mm
125mm
150mm
200mm
250mm
300mm
350mm
400mm
450mm
500mm
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
1.3
1.3
1.4
1.7
1.9
1.9
2.2
2.4
2.6
3.0
3.8
4.5
5.5
7.5
8.5
9
12
14
16
140
140
145
155
160
165
170
180
185
200
220
235
260
295
320
340
375
405
430
SIZE L *A Weight (kg)
* A and weight are for JIS10K flange installation and is reduced by 45mm in case isolation valve is NOT provided. Weight of isolation valve is 0.2kg
ORIFLO
TOKYO KEISO CO., LTD. 11TG-F771-5E
Main pipe
Flange connection type (10mm~500mm)
Other connection
L
540
As per descriptionpages 8 and 10.
Main pipe
* By-pass piping size will be 1/2" for PVC.
Screw connection
Flange connection
Wafer connection
Orifice plate
FittingA,B
Bypass piping
Ball valve
Indicator
*
FCD400,SCS14,SUS304,SUS316,PVC
SGP/SS400,SUS304,SUS316,PVC
SS400,SUS304,SUS316,SCS14,PVC
SUS304,SUS316,PVC
SCS14,HT.PVC
SGP(W),SUS304,SUS316,PVC
C3771BE,SCS14A,PVC
SCS14,HT ● PVC
Indicator can be located separately from process by using by-pass piping for easy observation of indication. Ball valves are provided for indicator maintenance purpose. Different materials are available as shown in below table.Special design for bypass piping is available on request.
●INDICATOR SEPARATION VERSION O- 8 - B - -
TOKYO KEISOJAPAN
102 65
2-Rc3/8
2-Rc3/8
80
(200
)
L
Std
. (10
00)
ORIFLO
12 TOKYO KEISO CO., LTD. TG-F771-5E
(2) LOCAL INDICATION WITH ALARM CONTACT O-78
(1) LOCAL INDICATION ONLY O-18
●ISOLATION VALVE
●INDICATOR
MATERIAL (SCS14) MATERIAL (HT.PVC)
MATERIAL (SCS14) MATERIAL (PVC, HT.PVC)
MATERIAL (SCS14) MATERIAL CLASS (HT.PVC)
85 44
5
5
OP
EN
OP
EN
ORIFLO
TOKYO KEISO CO., LTD. 13TG-F771-5E
In addition to standard O-180 with Glass tube flowmeter indication, O-190 series Dial indication type is available. Consult
factory for details.
A. Integrated Dial Indication type O-190-DG
O-190-DG indicaters flowrate by pressure gauges. 3 waymanifold valve is provided.
B. 0-190-B ■ separate indication seriesDifferent types of pressure indicators can be used for indication of flow rate. They can be installed separately away fromorifice piping for better observation.
O-190 SERIES DIAL INDICATOR TYPE
LRc1/4
Rc1/4
H
50
A'A
WINDOW
200
400
WINDOW
(160
0)
Air Vent Air VentZERO ADJ.(H)
(H)
(L)
(L)54Rc1/2 Rc1/2
MAX.240
MAX.87
(235
)
øD
t
2" pipe
(79)
LRc1/4
HRc1/4
270
Max
.120
500
Max.190 Max.95
(A(±
) 2)
(90(±))
Rc1/4
a. Manometer indication O-190-BDO-190-BD
c. Dial indication O-190-BMO-190-BM d. Indication in protection housing O-190-BSO-190-BS
b. U shaped Manometer indication O-190-BUO-190-BU
ORIFLO
14 TOKYO KEISO CO., LTD. TG-F771-5E
SUGGESTIONS
Upsttream
Downstream
90° elbow
10D
4D
Fully opened valve
12D
4D
Description
Flange
Bolt and nuts
Gaskets
Material
SS400, SUS304,SUS316
SS400, SUS304
Non-asbestos, NBR, FPM, Others
Q'ty
2
As required
2
Gas application Liquid application for local indicator
Alarm versions (Metallic material) Alarm versions (PVC material)
center
top top
top
Description
TS Socket welding flange
Bolt and nuts
Gaskets
Material
PVC, HT.PVC
SS400, SUS304
NBR, EPDM, Others
Q'ty
2
As required
2
Air elimination plug
Rc1/4 Rc1/4
R1/4 R1/4
Airelimination
Drainelimination
MATERIALCLASS 1 2 3
Nipple Nipple
Ball valve
(SCS13) (SCS14)
Ball valve
(C3771BE)
(1) Required straight run upstream and downstream
The following straight run is recommended for accuratemeasurement :
(3) Reading of flow rate
The flow rate is to be read by the position of floatand engraved graduation. Refer to the following :
(2) Air bubble elimination and draining
Air bubble in the indicator may cause measurement error.
Eliminate the air in the indicator through Air elimination
plug at the top of indicator for the start-up.
For liquid application, it is recommended to close the
isolation valve and drain out the liquid in the indicatorthrough drain plug in case the operation of process is
stopped for some reason.
Freezing of the liquid in the tapered tube may causebreakage of tube. Indicator with drain valve is available
on request.
(4) Flow direction
By changing the direction of indicator, ORIFLO may beused for any flow direction of bottom to top, left to right,right to left and top to bottom. This change can beconducted in the field as well.
Ball valves are available for air eliminator and drain outas option as follows ;
MATERIAL CONSTRUCTION
(2) TS FLANGES
TS socket welding flanges are also available on request :ACCESSORIES
(1) COUNTER FLANGESCounter flanges are available on request.Supply scope is as follows :
ORIFLO
TOKYO KEISO CO., LTD. 15TG-F771-5E
Specify the following for order or inquiry ;
MODEL O – ■ 8 ■ – ■ ■ – ■■■ – ■
Fluid name ______________________________________________________________Density _____________■ g/cm3 ■ kg/m3(nor) ■_____________
Viscosity _____________■ mPa.s
Pressure Nor._____________Max._____________ ■ MPa ■_____________Temperature Nor._____________Max._____________ ■ °C ■_____________
Connection ■ Rc ■ Other thread (_____________)■ JIS10KFF ■ JIS10KRF ■ Other flange (_____________)
■ Wafer for JIS10K flange ■ Wafer for other flange (_____________)
Inner diameter of process piping ■ SGP ■_____________mm_____________
Full scale _____________■ m3/h ■ m3/h(nor) ■_____________
Seal material ■ NBR ■ FPM ■ Others (_____________)
In case of alarm version Number of point ■ 1 ■ 2
Setting 1 ( ■ H ■ L at________■ m3/h ■ m3/h(nor) )
Setting 2 ( ■ H ■ L at________■ m3/h ■ m3/h(nor) )
Installation accessories ■ Counter flanges Material ( )■ TS flanges Material ( )
Other special instructions, if any ; ___________________________________________________________
_____________________________________________________________________________________ __
ORDERING INFORMATION
ORIFLO
16 TG-F771-5E
* Specification subject to change without notice
Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558
Tel : 03 – 3431 – 1625 (KEY) ; Fax : 03 – 3433 – 4922
e-mail : [email protected] ; URL : http://www.tokyokeiso.co.jp
● O-181-SN ● O-181-WC ● O-186-SN
● O-181-WC ● O-786-SN● O-188-FC