T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings h— B —H r^-HbU- ^F^^SNsv I Steel malleable iron, or aluminum tapered hub threads. With safe-edge ground thru 4" cone and double bevel seating ring (through 2"). Malleable iron, tapered hub threads. With safe- edge ground cone and double bevel sealing ring (through 2"). Straight Connectors* I Cat. No. Insulated Non-Insulated Steel Aluminum Steel 5229* 5330* 5331* 5231 AL 5231 f 5332 f 5232AL 5232 f 5333' 5233AL 5233' 5334' 5234AL 5234' 5335' 5235AL 5235' 5336 5236AL 5236 5337 5237AL 5237 5338 5238AL 5238 5339 5239AL 5239 5340 5240AL 5240 5385* - 5285 5386» nnnrt.iit Dimensions (in.) Size A B C </4 % 1% % 5 /16 63 /64 1 3 /8 15 /32 % 1%2 1</2 %i 1 /2 1% 1% 9 /16 3 /4 1% 1% % 1 1 7 /s 2!4 3 /i 1 1 /4 2%2 2V4 % 1 1 /2 2% 2 11 /16 % 2 3 1 /4 3 Me 7 /s 2M» 3% V/e 1 3 4'/2 4'/4 1 4 5 1 /2 4 1 /2 -P/8 5 8% 7 1 7 /s 6 6% 8 1 /2 2 © @ 45° Angle Connectors* CatN °- Conduit Insulated Non-Insulated Size 5341'** 5241' % 5342' 5242' '/2 5343' 5243* % 5344' 5244' 1 5345' 5245' 1'/4 5346 5246 Vh 5347 5247 2 5348 5248 2V? 5349 5249 3 5350 5250 4 Dimensions (in.) A B C 1%2 1% % 1% 1% 9 /6 1% 2% %; 1 7 /8 2 1 4 3 /4 2%2 2% % 2 23 /32 3% 13 /6 3 1 /4 3% 7 /8 3% 4'/4 1 4 1 /2 4 1 /4 1 5'/2 4 5 /s Wa © @ 190° Angle Connectors Cat. Ho. Insulated Non-Insulated Aluminum 5351 5251 5251 AL 5352 5252 5252AL 5353 5253 5253AL 5354 5254 5254AL 5355 5255 5255AL 5356 5256 5256AL 5357 5257 5257AL 5358 5258 5359 5259 5360 5260 Huh Conduit Dimensions (in.) Size Size A B C 1 /2" %" 1 5 ^2 1% % !/2" 1 /2" 1% 1 9 /16 % %" 3 /4" 1 2 ^2 1 3 /4 ^6 1" 1" r/8 2 3 /w % V/f V/f 2%2 2% % 1 1 /2" 1 1 /2" 2 2 %2 2% % 2" 2' 3 1 /* 35fe % 2 1 /2" 2 1 /2 (1 3% 8% 1 3" 3" 4% 10 1 /4 1 4" 4" 5 1 /2 12% V/a ' Suitable for hazardous locations use in Class I, Div. 2; Class II. Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per NEC Section 500-2(a). ** %" Conduit Fitting has Vf hub. ' U.L. Listed as grounding means under NEC 351-7. ' Not U.L. Listed. Note: U.L. Listed liquidtight; and CSA Certified watertight. Available with DURA-PLATE* Finish. U.L File No. E-23018 CSA File No. 2884 For Wiremesh Grips refer to pages 116,152. ThomasiBetts © 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COITI 115
Transcript

T&B Conduit FittingsLiquidtight Flexible Metal Conduit Fittings

h—B—Hr̂ -HbU-F̂̂ ^SNsv I

Steel malleable iron, or aluminum tapered hubthreads. With safe-edge ground thru 4" coneand double bevel seating ring (through 2").

Malleable iron, tapered hub threads. With safe-edge ground cone and double bevel sealingring (through 2").

<§Straight Connectors* I

Cat. No.Insulated Non-InsulatedSteel Aluminum Steel

5229*5330*5331* 5231 AL 5231 f

5332f 5232AL 5232f

5333' 5233AL 5233'5334' 5234AL 5234'5335' 5235AL 5235'5336 5236AL 52365337 5237AL 52375338 5238AL 52385339 5239AL 52395340 5240AL 52405385* - 52855386»

nnnrt.iit Dimensions (in.)Size A B C

</4 % 1% %

5/16 63/64 13/8 15/32

% 1%2 1</2 %i1/2 1% 1% 9/163/4 1% 1% %

1 17/s 2!4 3/i11/4 2%2 2V4 %

11/2 2% 211/16 %

2 31/4 3 Me 7/s2M» 3% V/e 13 4'/2 4'/4 14 51/2 41/2 -P/8

5 8% 7 17/s6 6% 81/2 2

© @

45° Angle Connectors*CatN°- Conduit

Insulated Non-Insulated Size

5341'** 5241' %5342' 5242' '/25343' 5243* %5344' 5244' 15345' 5245' 1'/45346 5246 Vh5347 5247 25348 5248 2V?5349 5249 35350 5250 4

Dimensions (in.)

A B C

1%2 1% %

1% 1% 9/6

1% 2% %;17/8 214 3/4

2%2 2% %223/32 3% 13/6

31/4 3% 7/8

3% 4'/4 141/2 41/4 1

5'/2 45/s Wa

© @

190° Angle ConnectorsCat. Ho.

Insulated Non-Insulated Aluminum

5351 5251 5251 AL5352 5252 5252AL5353 5253 5253AL5354 5254 5254AL5355 5255 5255AL5356 5256 5256AL5357 5257 5257AL5358 52585359 52595360 5260

Huh Conduit Dimensions (in.)Size Size A B C

1/2" %" 15^2 1% %

!/2" 1/2" 1% 19/16 %

%" 3/4" 12^2 13/4 ^6

1" 1" r/8 23/w %V/f V/f 2%2 2% %11/2" 11/2" 22%2 2% %

2" 2' 31/* 35fe %21/2" 21/2(1 3% 8% 13" 3" 4% 101/4 14" 4" 51/2 12% V/a

' Suitable for hazardous locations use in Class I, Div. 2; Class II. Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipmentis specifically permitted per NEC Section 500-2(a).** %" Conduit Fitting has Vf hub.' U.L. Listed as grounding means under NEC 351-7.' Not U.L. Listed.Note: U.L. Listed liquidtight; and CSA Certified watertight.Available with DURA-PLATE* Finish.U.L File No. E-23018CSA File No. 2884

For Wiremesh Grips refer to pages 116,152.

ThomasiBetts

© 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COITI 115

T&B Conduit FittingsLiquidtight Flexible Metal Conduit Fittings

Liquidtight Flexible Metal Conduit Connectors

5331 Series*5231 AL Series

5361 Series

5271 Series*5341 Series...same as 5331, except 45° Connectors5351 Series...same as 5331, except 90° Connectors

5361 SeriesChase® Style

Application• Used where flexible metal raceway is

installed in outdoor or indoor loca-tions where exposed to continuous orintermittent moisture.

• To positively bond conduit to box orenclosure.

Features• Ability to install quickly with low

torque effort.• Ground cone design offers following

advantages:(1) Compresses metallic convolu-

tions; provides high qualityground contact with low imped-ance and high raceway holdingpower (A).

(2) Single helical thread on groundcone is easy to install withoutcross thread; accepts variationsin raceway diameters and convo-lution pitch (B).

(3) Rolled over edge protects con-ductors (C).

Sealing ring design has followingexclusive features:

(1) Grips and seals at leading andtrailing edge - will not abraderaceway jacket (D).

(2) Provided with grooves on insidediameter for anti-sleeving (E).

(3) Shoulders on both ends for extrasealing (F).

(4) Symmetrical shape assures fool-proof assembly.

• Can be disconnected and reused.• Watertight/oil tight installation at box or

enclosure termination is assured by:(1) External taper thread hub on 5331

series and use of sealing gasket5262 series (G).

(2) Captivated sealing 'O' ring on5361 series (H).

(3) Taper tapped hole on 5271 series.• Suitable for use in Class I Division 2,

Class II Division 1 and 2 and Class IIIDivision 1 and 2 HazardousLocations per N.E.C. Section 500.

• Suitable as a grounding means perN.E.C. Section 351-9 (up to W tradesize on).

• 1/2" & 114" sizes Laboratory tested tocarry ground fault current of up to1000 amps RMS with duration of faultcurrent 3 cycles.

• Conforms with JIG requirements.• Available with imperial, I.S.O. & PG

threaded hub.

Standard Material5331-5361-5271 SeriesBody, Gland, Locknut & Ground

Cones: All steel or malleable iron.Sealing Ring and Insulator: All thermo-

plasticSealing Gasket: Stainless Steel and

Buna N5231 AL SeriesAll Copper-free Aluminum (non-

insulated)5332SST Series31L Stainless Steel insulated5332B SeriesMarine grade brass insulated avantStandard Finish5331-5361-5271 SeriesElectro Zinc Plated & Chromate Coated5231 AL SeriesCopper-free Aluminum

Range5331 Series.............M* thru 6"* conduit5341 Series................W thru 4" conduit5351 Series................%" thru 4" conduit5361 Series................W thru 4" conduit5271 Series..............%"thru VA° conduit5231 AL Series..........%" thru 4" conduit5332SST Series.............1/2" & W conduit5332B Series.................1/2" & %" conduitAll hubs provided with taper pipethreads (NPT)

Listed/Certified by:U.L...(U.L File No. E-23018)CSA...(LR-2884, LR-4484, LR-9555)

Conforms to:U.L. 514BCSAC22.2NO. 18NEMA FB-1NFPA 70-1999 (ANSI)JICEGP1JICEMP1Federal Specification W-F-406Federal Standard H-28 (Threads)