NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
1 / 14
LM-79-08 Test Report
For
E-Lite Semiconductor Inc.
NO.507, 4th Gang Bei Road,
Modern Industrial Park North,
Pixian, Chengdu
LED Luminaire
Model name(s): EL-CP-100
Representative (Tested) Model: EL-CP-100
Model differences: N/A
Test & Report By: Review By:
Sean Zhuo
Engineer: Sean Zhuo Manager: Tommy Liang
Date: 2014-02-19
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or
any agency of the Federal Government.
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
2 / 14
U.S. Department of Energy
Lighting FactsTM
Uniform LM-79 Reporting Template
Laboratory Information:
Name of Test Laboratory Standard-Tech Co. Ltd
Date of Test Report Feb. 19, 2014
Test Report No. STD1401013-I
Laboratory Contact Name Tommy Liang
Product Information:
Organization Name E-Lite Semiconductor Inc.
Brand Name N/A
Model Number EL-CP-100
SKU (if available) N/A
Type of Luminaire
(for integral lamps, list base type and lamp type) LED Luminaire
Luminaire Aperture (for downlights) -- in.
Luminaire Length 410 mm
Luminaires Width 400 mm
Number of Units (modular products) N/A s
Electrical Measurements:
Integrating Sphere
Output
Goniophotometer
Output
Input Wattage -- 97.87 W
Input Current -- 0.8205 A
Input Voltage (ac) -- 120.1 V
Power Factor -- 0.9931
Off-State Power -- 0 W
Photometric Characteristics
Total Initial Lumen Output -- 9591.5 lm
Initial Lumen Efficacy -- 98.00 lm/w
Correlated color temperature / CCT 4999 -- K
Color rendering index / CRI 72.3 --
R9 Value 0 --
Duv 0.0006 --
Luminous Intensity Distribution
Center beam candlepower (if applicable)
-----
3164 cd
Beam angle (if applicable) 110.8 °
Zonal lumens in the 0°-60° zone 73.60 %
Zonal lumens in the 60°-90° zone 15.76 %
Zonal lumens in the 90°-120° zone 0.07 %
Zonal lumens in the 120°-180° zone 0.14 %
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
3 / 14
Test Specifications:
Date of Receipt : Feb.18, 2014
Date of Test : Feb.19, 2014
Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous
Efficacy, Correlated Color Temperature, Color Rendering Index,
Chromaticity Coordinate, Electrical parameters
Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI C78.377-2008 Specifications for the Chromaticity of Solid State
Lighting Products
CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering
Properties of Light Sources
CIE 15-2004 Technical Report Colorimetry
IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems
Reference Work
Instruction
QD25
Test Methods
1. Photometric and Electrical measurements – Light Distribution Method:
Photometric parameters were measured using the goniophotometer and software. The ambient
temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the
sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was
stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were
calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.
2. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.
The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample
measurements were made using a spectroradiometer connected by a fiber optic cable and detector
through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It
was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature
and color rendering index were calculated from the spectral radiant flux measurements taken at least 5
nm intervals over the range of 380 to 780 nm.
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
4 / 14
1. Product Information:
Brand Name N/A
Model Number EL-CP-100
Luminaire Type LED Luminaire
Rated Voltage / Frequency 100 ~ 277 Vac, 50/60 Hz
Nominal Power 100W
Rated Initial Lamp Lumen --
Declared CCT 5000K
LED Manufacturer CREE
LED Model XTE
Sample Receipt Date Feb.18, 2014
Sample Number 1401013-9
Photo
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
5 / 14
2.1 Electrical, Photometric and Chromaticity Measurements
(Refer to Work Instruction QD25)
IES LM-79 2008
Test date 2014-02-19 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number EL-CP-100
Electrical Measurement:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
1401013-9 120.1 60 0.8205 97.87 0.9931 7.56
277.0 60 0.3824 98.85 0.9332 13.66
Sphere-Spectroradiometer Method:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 72 R9 0
Frequency (Hz) 60 R2 75 R10 40
Color Rendering Index (CRI) 72.3 R3 76 R11 74
R9 0 R4 74 R12 45
CCT (K) 4999 R5 73 R13 71
Chromaticity (x, y) x=0.3453 y=0.3530 R6 66 R14 86
Chromaticity (u’, v’) u'=0.2110 v'=0.4854 R7 79 R15 68
Duv 0.0006 R8 63 -- --
Goniophotometer Method:
Parameter Result
Test Voltage (V) 120.1
Frequency (Hz) 60
Test Current (A) 0.8205
Power Factor 0.9931
Test Power (W) 97.87
Total Luminous (lm) 9591.5
Luminous Efficacy (lm/W) 98.00
Beam Angle° 110.8
Center Beam Candle Power (cd) 3164
S/MH(C0/180) 1.25
S/MH(C90/270) 1.24
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
6 / 14
Spectral Power Distribution
Spectral Power Distribution:
Spectral Distribution over Visible Wavelength:
WL(nm) Radiant(W) WL(nm) Radiant(W) WL(nm) Radiant(W) WL(nm) Radiant(W)
380 3.006 490 23.69 600 107.9 710 10.91
390 0.9334 500 45.72 610 99.59 720 8.284
400 1.605 510 74.45 620 88.9 730 6.275
410 6.589 520 97.99 630 76.41 740 4.755
420 30.97 530 110.4 640 63.89 750 3.585
430 95.75 540 117 650 51.82 760 2.716
440 211.8 550 119.7 660 40.99 770 2.128
450 129.5 560 120.6 670 31.61 780 1.695
460 48.87 570 120.2 680 24.67 -- --
470 21.96 580 118.5 690 19.04 -- --
480 16.66 590 114.1 700 14.5 -- --
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
7 / 14
Chromaticity Diagram
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
8 / 14
Zonal Lumen Tabulation
Zone Lumens % Lamp / Luminaire
0~ 10° 299.1 3.12%
10 ~ 20° 853.9 8.90%
20 ~ 30° 1289 13.44%
30~ 40° 1549 16.15%
40 ~ 50° 1615 16.84%
50~ 60° 1454 15.16%
60 ~ 70° 1181 12.31%
70 ~ 80 ° 831.7 8.67%
80 ~ 90 ° 496.8 5.18%
90 ~ 100 ° 2.216 0.02%
100 ~ 110 ° 3.774 0.04%
110 ~ 120 ° 2.654 0.03%
120 ~ 130 ° 3.017 0.03%
130 ~ 140 ° 3.143 0.03%
140 ~ 150 ° 2.944 0.03%
150 ~ 160 ° 2.486 0.03%
160 ~ 170 ° 1.674 0.02%
170 ~ 180 ° 0.6579 0.01%
Zone Lumens % Lamp / Luminaire
0~60 ° 7059 73.60%
60 ~90° 2512 26.19%
0 ~90° 9571 99.79%
90~180° 20 0.21%
0~180° 9591 100.00%
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
9 / 14
Photometric Data
Illuminance Plots
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
10 / 14
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
11 / 14
Candela Table - Type C
0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162 3162
1 3161 3162 3161 3162 3162 3160 3161 3160 3159 3160 3160 3162 3160 3161 3161 3163 3161
2 3158 3158 3157 3160 3161 3157 3159 3157 3154 3156 3157 3164 3156 3160 3160 3163 3158
3 3155 3156 3154 3158 3160 3155 3157 3153 3150 3150 3153 3161 3148 3157 3157 3160 3155
4 3152 3153 3149 3154 3153 3151 3152 3148 3146 3146 3147 3157 3141 3156 3154 3155 3152
5 3147 3147 3147 3151 3144 3148 3146 3143 3142 3141 3140 3148 3136 3154 3150 3149 3147
6 3144 3141 3142 3148 3133 3144 3141 3136 3137 3135 3134 3142 3127 3150 3146 3145 3144
7 3139 3136 3137 3144 3122 3138 3135 3130 3129 3129 3124 3136 3117 3144 3141 3142 3139
8 3129 3130 3129 3139 3112 3128 3129 3121 3120 3122 3117 3132 3102 3136 3137 3138 3129
9 3120 3124 3116 3134 3100 3117 3120 3112 3111 3110 3104 3120 3085 3126 3128 3127 3120
10 3109 3117 3104 3126 3081 3108 3111 3098 3100 3099 3090 3107 3068 3110 3123 3116 3109
11 3099 3109 3091 3112 3062 3093 3096 3083 3084 3087 3076 3094 3047 3097 3109 3101 3099
12 3086 3098 3077 3097 3043 3079 3080 3069 3069 3073 3060 3076 3027 3083 3093 3088 3086
13 3071 3084 3065 3081 3025 3064 3065 3054 3054 3059 3047 3056 3008 3067 3077 3073 3071
14 3053 3069 3053 3067 3009 3048 3048 3038 3038 3044 3031 3037 2990 3044 3063 3056 3053
15 3036 3052 3041 3050 2991 3031 3029 3023 3022 3028 3012 3020 2969 3025 3049 3038 3036
16 3019 3032 3026 3031 2974 3015 3012 3006 3004 3011 2991 3005 2947 3005 3030 3020 3019
17 3002 3012 3011 3006 2955 2999 2996 2988 2984 2992 2969 2988 2927 2986 3008 3003 3002
18 2980 2993 2994 2983 2936 2980 2978 2967 2962 2972 2948 2965 2907 2965 2987 2985 2980
19 2959 2971 2972 2966 2916 2960 2957 2945 2939 2951 2927 2937 2887 2940 2962 2964 2959
20 2935 2949 2949 2949 2899 2938 2935 2922 2916 2927 2904 2910 2868 2913 2939 2940 2935
21 2911 2926 2923 2932 2885 2912 2910 2898 2892 2900 2879 2884 2847 2887 2917 2917 2911
22 2887 2901 2899 2908 2868 2880 2883 2876 2867 2871 2855 2857 2825 2866 2893 2894 2887
23 2860 2878 2875 2880 2846 2847 2854 2851 2840 2841 2833 2832 2807 2844 2867 2869 2860
24 2834 2853 2851 2853 2820 2821 2824 2826 2810 2811 2808 2811 2789 2818 2838 2843 2834
25 2806 2826 2822 2822 2794 2800 2796 2798 2780 2777 2776 2786 2760 2789 2807 2815 2806
26 2779 2800 2790 2790 2762 2775 2768 2770 2749 2745 2744 2759 2728 2758 2772 2786 2779
27 2753 2772 2761 2762 2733 2747 2738 2743 2719 2715 2708 2731 2699 2729 2738 2756 2753
28 2727 2741 2733 2737 2706 2716 2706 2716 2688 2686 2672 2702 2673 2699 2710 2729 2727
29 2697 2708 2701 2711 2681 2680 2672 2688 2654 2655 2641 2665 2639 2665 2686 2701 2697
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
12 / 14
30 2665 2675 2667 2676 2654 2644 2638 2657 2619 2620 2609 2630 2599 2630 2658 2672 2665
31 2636 2642 2635 2641 2620 2610 2598 2626 2586 2586 2575 2595 2569 2599 2623 2642 2636
32 2604 2610 2600 2608 2587 2575 2558 2590 2553 2556 2542 2558 2551 2565 2586 2608 2604
33 2572 2581 2571 2572 2549 2541 2526 2555 2521 2524 2513 2522 2527 2527 2552 2574 2572
34 2538 2550 2539 2543 2511 2505 2498 2519 2490 2492 2478 2488 2487 2493 2519 2540 2538
35 2506 2520 2501 2509 2474 2474 2467 2483 2455 2457 2438 2453 2438 2463 2481 2508 2506
36 2474 2488 2461 2473 2445 2443 2434 2448 2417 2422 2397 2413 2396 2425 2440 2482 2474
37 2441 2453 2418 2434 2413 2403 2399 2410 2379 2386 2362 2376 2358 2386 2399 2450 2441
38 2404 2415 2384 2396 2376 2362 2361 2374 2334 2346 2324 2339 2314 2352 2359 2411 2404
39 2363 2376 2347 2361 2335 2326 2325 2340 2288 2306 2282 2306 2279 2318 2321 2374 2363
40 2327 2338 2311 2326 2290 2290 2283 2303 2243 2260 2236 2268 2244 2273 2284 2337 2327
41 2285 2301 2279 2289 2251 2256 2239 2256 2198 2216 2193 2227 2208 2240 2249 2300 2285
42 2232 2262 2243 2243 2203 2219 2201 2208 2150 2173 2153 2192 2182 2204 2207 2253 2232
43 2179 2212 2201 2210 2161 2182 2165 2164 2100 2138 2125 2163 2155 2179 2168 2199 2179
44 2172 2156 2158 2182 2138 2145 2125 2117 2083 2088 2090 2133 2181 2152 2133 2142 2172
45 2113 2111 2130 2152 2113 2117 2089 2068 2043 2037 2040 2109 2160 2113 2086 2095 2113
46 2040 2099 2092 2129 2102 2099 2048 2038 1987 1997 2006 2079 2098 2112 2048 2098 2040
47 1977 2049 2037 2094 2144 2057 1995 1988 1917 1940 1968 2055 2006 2083 2005 2026 1977
48 1926 1979 1988 2086 2096 2041 1955 1927 1885 1882 1903 1985 1935 2008 1952 1936 1926
49 1913 1913 1951 2053 1985 2030 1917 1866 1876 1814 1860 1915 1832 1939 1904 1876 1913
50 1899 1861 1901 1965 1919 1931 1877 1838 1840 1782 1820 1854 1747 1862 1862 1834 1899
51 1837 1834 1860 1880 1842 1852 1823 1816 1822 1755 1790 1776 1678 1787 1828 1806 1837
52 1813 1798 1817 1826 1756 1793 1780 1781 1778 1718 1767 1695 1629 1702 1821 1762 1813
53 1775 1771 1798 1761 1670 1725 1739 1748 1731 1672 1710 1624 1581 1639 1764 1726 1775
54 1737 1728 1780 1688 1597 1640 1722 1714 1695 1636 1648 1559 1533 1576 1685 1691 1737
55 1696 1692 1696 1638 1560 1582 1660 1668 1655 1593 1595 1515 1507 1514 1624 1659 1696
56 1657 1664 1636 1589 1540 1526 1595 1621 1611 1549 1535 1489 1499 1490 1564 1619 1657
57 1612 1621 1576 1540 1519 1491 1557 1573 1562 1506 1470 1474 1486 1480 1504 1579 1612
58 1567 1579 1516 1520 1498 1463 1494 1528 1513 1468 1401 1462 1471 1467 1426 1532 1567
59 1513 1536 1438 1491 1468 1439 1422 1479 1456 1419 1334 1444 1440 1451 1353 1479 1513
60 1452 1484 1378 1462 1454 1411 1362 1431 1401 1365 1278 1427 1408 1434 1297 1432 1452
61 1397 1438 1328 1434 1437 1387 1303 1387 1348 1316 1225 1409 1370 1415 1262 1385 1397
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
13 / 14
62 1357 1386 1299 1415 1405 1368 1258 1341 1306 1263 1192 1380 1324 1379 1235 1327 1357
63 1341 1336 1274 1385 1353 1340 1225 1301 1281 1216 1176 1335 1272 1347 1220 1272 1341
64 1266 1286 1258 1351 1295 1301 1203 1251 1200 1187 1169 1281 1210 1298 1210 1238 1266
65 1131 1256 1232 1309 1231 1250 1184 1213 1096 1150 1155 1216 1153 1237 1198 1215 1131
66 1060 1178 1209 1248 1177 1192 1160 1147 1032 1065 1144 1144 1095 1158 1179 1112 1060
67 1016 1064 1175 1181 1133 1124 1133 1057 979 978 1121 1075 1065 1080 1159 1019 1016
68 964 1020 1146 1100 1164 1058 1109 1009 937 938 1100 1014 1111 1013 1129 987 964
69 934 995 1119 1058 1113 1031 1082 981 918 909 1089 1016 953 1018 1106 959 934
70 920 973 1106 1055 992 1040 1058 963 903 883 1051 997 818 980 1092 928 920
71 889 945 1034 961 822 954 1009 927 868 844 965 814 751 802 990 883 889
72 918 890 945 847 794 814 918 866 882 799 868 771 723 754 890 832 918
73 888 851 879 800 799 782 857 821 823 771 829 759 727 755 847 824 888
74 758 865 880 837 792 810 873 838 733 767 853 758 733 766 865 786 758
75 726 763 823 859 776 822 803 731 710 692 745 767 729 793 746 713 726
76 696 739 759 860 771 817 733 744 695 706 709 766 720 808 710 726 696
77 668 735 738 858 768 826 723 754 665 744 705 771 703 791 724 727 668
78 624 749 756 832 735 817 743 746 597 750 698 766 627 790 713 747 624
79 609 738 734 801 646 784 730 721 588 713 698 696 541 696 732 714 609
80 578 708 722 727 586 726 736 692 563 663 736 629 501 629 730 667 578
81 560 672 732 704 594 700 741 669 563 644 699 623 503 620 701 640 560
82 553 665 718 718 606 726 718 675 551 646 675 656 492 638 674 634 553
83 523 688 701 754 586 746 695 699 513 657 664 727 477 707 642 663 523
84 410 741 698 755 505 742 700 710 355 663 661 657 435 670 641 704 410
85 218 729 671 696 402 670 673 693 195 638 625 598 268 606 634 679 218
86 166 619 623 598 213 576 614 623 158 587 549 504 161 507 547 598 166
87 64 497 523 578 157 511 535 550 126 525 457 458 139 471 464 401 64
88 20 101 318 297 86 312 422 232 35 180 327 204 50 185 115 63 20
89 11 17 25 61 19 95 30 24 14 19 20 28 14 20 14 14 11
90 2 5 7 12 11 14 10 10 9 9 8 8 7 5 3 2 2
NVLAP LAB CODE 201011-0
Report No.: STD1401013-I
Laboratory: Standard-Tech Co. Ltd Testing Center
NVLAP CODE: 201011-0
Report Format Number STD/QR4909-A/2
Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
14 / 14
3. Test Equipment
Equipment ID Equipment Name Last Calibration Date Next Calibration Date
ST-R-336 2 meter Integrating Sphere 2013-07-08 2014-07-07
ST-R-331 Spectral analysis system HAAS-2000 2013-06-21 2014-06-20
D204 Standard Lamp 2013-06-28 2014-06-27
PF2010 Power Meter for Integrating Sphere 2013-06-20 2014-06-19
EE-09 Goniophotometer system 2013-06-21 2014-06-20
D908S Standard Lamp 2013-07-05 2014-07-04
PF210 Power Meter for Goniophotometer 2013-06-20 2014-06-19
ST-R-181A Temperature Tester 2013-08-14 2014-08-13
****** END OF DATASHEET PACKAGE ******