NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
1 / 19
LM-79-08 Test Report For
SUZHOU WISTA LIGHTING TECHNOLOGY
CO.,LTD
(Brand Name:N/A)
Building 8,No.120, East Chen Feng Rd., Yushan Town, Kunshan City, Jiangsu,P.R.China.
Outdoor Pole/Arm-mounted Area and Roadway Luminaires
Model name(s): WST-SBL-2-150W
Representative (Tested) Model: WST-SBL-2-150W(4000K) WST-SBL-2-150W(5700K)
Model Difference: All construction and rating are the same, except CCT.
Test & Report By: Review By:
Johnson Sun
Engineer: Johnson Sun Manager: Tommy Liang
Date: Jun.06,2016
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or
any agency of the Federal Government.
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
2 / 19
U.S. Department of Energy
Lighting FactsTM Uniform LM-79 Reporting Template Laboratory Information:
Name of Test Laboratory Standard-Tech Co., Ltd.
Date of Test Report Jun.06,2016
Test Report No. STD160316NB-2-G
Laboratory Contact Name Tommy Liang
Product Information:
Organization Name SUZHOU WISTA LIGHTING TECHNOLOGY
CO.,LTD
Brand Name N/A
Model Number WST-SBL-2-150W(4000K)
SKU (if available) N/A
Type of Luminaire
(for integral lamps, list base type and lamp type)
Outdoor Pole/Arm-mounted Area and Roadway
Luminaires
Luminaire Aperture (for downlights) -- in.
Luminaire Length -- mm
Luminaires Width -- mm
Number of Units (modular products) N/A
Electrical Measurements:
Integrating Sphere
Output
Goniophotometer
Output
Input Wattage -- 149.1 W
Input Current -- 1.252 A
Input Voltage (ac) -- 120.0 V
Power Factor -- 0.9927
Off-State Power -- 0 W
Photometric Characteristics
Total Initial Lumen Output -- 15935 lm
Initial Lumen Efficacy -- 106.87 lm/w
Correlated color temperature / CCT 4048 -- K
Color rendering index / CRI 73.5 --
R9 Value 0 --
Duv -0.0031 --
Luminous Intensity Distribution
Center beam candlepower (if applicable)
---
4828 cd
Beam angle (if applicable) 98.4 °
Zonal lumens in the 0°-60° zone 87.8 %
Zonal lumens in the 60°-90° zone 12.1 %
Zonal lumens in the 90°-120° zone 0 %
Zonal lumens in the 120°-180° zone 0.1 %
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
3 / 19
U.S. Department of Energy
Lighting FactsTM Uniform LM-79 Reporting Template Laboratory Information:
Name of Test Laboratory Standard-Tech Co., Ltd.
Date of Test Report Jun.06,2016
Test Report No. STD160316NB-2-G
Laboratory Contact Name Tommy Liang
Product Information:
Organization Name SUZHOU WISTA LIGHTING TECHNOLOGY
CO.,LTD
Brand Name N/A
Model Number WST-SBL-2-150W(5700K)
SKU (if available) N/A
Type of Luminaire
(for integral lamps, list base type and lamp type)
Outdoor Pole/Arm-mounted Area and Roadway
Luminaires
Luminaire Aperture (for downlights) -- in.
Luminaire Length -- mm
Luminaires Width -- mm
Number of Units (modular products) N/A
Electrical Measurements:
Integrating Sphere
Output
Goniophotometer
Output
Input Wattage 152.2 -- W
Input Current 1.273 -- A
Input Voltage (ac) 120.0 -- V
Power Factor 0.9960 --
Off-State Power 0 -- W
Photometric Characteristics
Total Initial Lumen Output 16573 -- lm
Initial Lumen Efficacy 108.89 -- lm/w
Correlated color temperature / CCT 5693 -- K
Color rendering index / CRI 71.9 --
R9 Value 0 --
Duv -0.0012 --
Luminous Intensity Distribution
Center beam candlepower (if applicable)
-----
cd
Beam angle (if applicable) °
Zonal lumens in the 0°-60° zone %
Zonal lumens in the 60°-90° zone %
Zonal lumens in the 90°-120° zone %
Zonal lumens in the 120°-180° zone %
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
4 / 19
Date of Receipt :May.18,2016
Date of Test :May.19,2016
Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy,
Correlated Color Temperature, Color Rendering Index, Chromaticity
Coordinate, Electrical parameters
Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State
Lighting Products
ANSI C78.377-2008 Specifications for the Chromaticity of Solid State
Lighting Products
CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering
Properties of Light Sources
CIE 15-2004 Technical Report Colorimetry
IESNA LM-16-93 Practical Guide to Colorimetry of Light Source
IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)
Sources and Systems
Reference Work
Instruction
QD25
Test Methods
1. Photometric and Electrical measurements – Light Distribution Method:
Photometric parameters were measured using the goniophotometer and software. The ambient temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.
2. Photometric and Electrical Measurements – Integrating Sphere Method:
Photometric parameters were measured using an integrating sphere, a spectroradiometer and software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample measurements were made using a spectroradiometer connected by a fiber optic cable and detector through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature and color rendering index were calculated from the spectral radiant flux measurements taken at least 5 nm intervals over the range of 380 to 780 nm.
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
5 / 19
1. Product Information:
Brand Name N/A
Model Number WST-SBL-2-150W
Luminaire Type Outdoor Pole/Arm-mounted Area and Roadway Luminaires
Rated Voltage / Frequency 100 ~ 277 Vac, 50/60Hz
Nominal Power 150W
Rated Initial Lamp Lumen --
Declared CCT 4000K,4500K,5000K,5700K
LED Manufacturer CREE
LED Model XTEAWT-00-0000-00000LBE7
Sample Receipt Date May.18,2016
Sample Number STD160316NB-2-G1(4000K),G2(5700K)
Photo
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
6 / 19
2.1 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25)
IES LM-79 2008
Test date 2016-05-19 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number WST-SBL-2-150W(4000K)
Electrical Measurement:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
STD160316
NB-2-G1
120.0 60 1.252 149.1 0.9927 7.09
277.0 60 0.5855 147.5 0.9094 14.23
Color Data:
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 74 R9 0
Frequency (Hz) 60 R2 78 R10 46
Color Rendering Index (CRI) 73.5 R3 79 R11 73
R9 0 R4 75 R12 44
CCT (K) 4048 R5 73 R13 73
Chromaticity (x, y) x=0.3763 y=0.3677 R6 68 R14 88
Chromaticity (u’, v’) u'=0.2260 v'=0.4969 R7 80 R15 70
Duv -0.0031 R8 62 -- --
Goniophotometer Method :
Parameter Result
Test Voltage (V) 120.0
Frequency (Hz) 60
Total Luminous (lm) 15935
Luminous Efficacy (lm/W) 106.87
Beam Angle° 98.4
Center Beam Candle Power (cd) 4828
Goniophotometer Method for 277V:
Parameter Result
Test Voltage (V) 277.0
Frequency (Hz) 60
Total Luminous (lm) 15903
Luminous Efficacy (lm/W) 107.82
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
7 / 19
Spectral Power Distribution & Chromaticity Diagram
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
8 / 19
Zonal Lumen Tabulation
Zonal Lumen Summary
Zone Lumens % Luminaire
0-30 4,486.3 28.2%
0-40 7,772.7 48.8%
0-60 13,990.0 87.8%
60-90 1,926.4 12.1%
70-100 732.3 4.6%
90-120 2.6 0%
0-90 15,916.4 99.9%
90-180 15.0 0.1%
0-180 15,931.4 100%
Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
0-10 470.0 3.0% 90-100 0.4 0%
10-20 1,493.7 9.4% 100-110 0.7 0%
20-30 2,522.6 15.8% 110-120 1.5 0%
30-40 3,286.4 20.6% 120-130 2.2 0%
40-50 3,585.5 22.5% 130-140 2.9 0%
50-60 2,631.8 16.5% 140-150 2.9 0%
60-70 1,194.5 7.5% 150-160 2.3 0%
70-80 597.6 3.8% 160-170 1.6 0%
80-90 134.3 0.8% 170-180 0.6 0%
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
9 / 19
Photometric Data
Illuminance Plots
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
10 / 19
ISOCANDELA DIAGRAM
ISOLUX DIAGRAM
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
11 / 19
Candela Table - Type C
0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828 4828
1 4819 4823 4826 4834 4839 4844 4845 4844 4841 4838 4832 4826 4822 4816 4814 4817 4819
2 4812 4820 4828 4843 4852 4862 4863 4863 4858 4851 4840 4827 4819 4806 4804 4807 4812
3 4809 4821 4833 4856 4870 4884 4887 4887 4877 4869 4852 4831 4820 4800 4797 4800 4809
4 4809 4827 4842 4873 4891 4909 4916 4916 4903 4892 4869 4842 4823 4797 4792 4797 4809
5 4812 4837 4855 4896 4920 4943 4949 4951 4933 4921 4890 4858 4832 4796 4790 4796 4812
6 4815 4849 4873 4923 4952 4982 4989 4992 4970 4956 4918 4878 4843 4801 4790 4796 4815
7 4822 4864 4897 4950 4987 5025 5039 5038 5009 4994 4951 4902 4859 4810 4796 4800 4822
8 4833 4884 4925 4978 5021 5073 5092 5091 5053 5033 4989 4929 4879 4824 4805 4810 4833
9 4850 4909 4956 5007 5054 5121 5156 5148 5095 5075 5031 4958 4903 4843 4820 4826 4850
10 4871 4938 4989 5036 5088 5172 5227 5209 5140 5117 5077 4992 4930 4867 4838 4848 4871
11 4893 4973 5027 5068 5124 5229 5308 5273 5186 5163 5127 5034 4957 4896 4863 4874 4893
12 4917 5013 5068 5105 5164 5292 5392 5343 5232 5211 5182 5083 4981 4928 4889 4901 4917
13 4942 5056 5113 5146 5205 5362 5486 5408 5275 5260 5242 5133 5004 4956 4923 4931 4942
14 4967 5102 5165 5190 5244 5435 5584 5472 5313 5305 5312 5186 5028 4984 4963 4961 4967
15 4992 5151 5228 5232 5277 5504 5681 5531 5349 5350 5384 5241 5053 5010 5006 4993 4992
16 5018 5202 5291 5271 5305 5570 5776 5590 5374 5393 5459 5301 5078 5039 5051 5025 5018
17 5042 5254 5361 5304 5326 5632 5867 5640 5384 5429 5534 5362 5104 5071 5099 5059 5042
18 5062 5309 5435 5331 5339 5690 5952 5684 5377 5451 5607 5429 5127 5104 5152 5093 5062
19 5075 5360 5503 5347 5337 5740 6036 5716 5356 5459 5676 5496 5140 5139 5205 5127 5075
20 5086 5410 5570 5350 5327 5776 6106 5735 5326 5458 5735 5552 5145 5169 5260 5160 5086
21 5089 5456 5631 5353 5316 5801 6169 5741 5292 5450 5779 5588 5143 5196 5315 5193 5089
22 5083 5491 5682 5350 5296 5818 6214 5739 5255 5433 5818 5612 5131 5213 5369 5218 5083
23 5070 5518 5720 5335 5272 5821 6237 5724 5219 5409 5843 5622 5116 5221 5426 5236 5070
24 5052 5528 5747 5315 5242 5812 6246 5704 5187 5381 5859 5619 5096 5222 5480 5243 5052
25 5032 5526 5761 5294 5206 5792 6248 5682 5153 5356 5863 5600 5073 5218 5525 5240 5032
26 5005 5510 5769 5269 5163 5774 6240 5656 5124 5332 5865 5576 5048 5210 5557 5230 5005
27 4968 5490 5773 5238 5122 5751 6226 5626 5103 5308 5866 5555 5016 5200 5583 5216 4968
28 4931 5468 5775 5211 5098 5718 6205 5599 5072 5288 5857 5531 4982 5184 5604 5197 4931
29 4897 5443 5768 5189 5072 5688 6193 5579 5027 5276 5854 5507 4947 5168 5615 5172 4897
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
12 / 19
30 4850 5418 5760 5180 5036 5672 6190 5554 4972 5258 5860 5486 4901 5151 5628 5155 4850
31 4791 5402 5759 5177 4987 5661 6208 5521 4909 5230 5878 5459 4838 5131 5649 5140 4791
32 4723 5384 5775 5162 4941 5642 6236 5489 4839 5196 5907 5425 4761 5096 5671 5115 4723
33 4651 5351 5811 5141 4877 5619 6276 5457 4757 5158 5958 5384 4660 5050 5697 5075 4651
34 4553 5314 5856 5114 4790 5609 6345 5425 4661 5112 6030 5337 4545 4993 5726 5028 4553
35 4445 5272 5917 5070 4685 5595 6460 5376 4559 5052 6133 5279 4412 4923 5760 4973 4445
36 4321 5222 6013 5006 4577 5564 6637 5317 4438 4984 6247 5213 4268 4839 5835 4904 4321
37 4188 5158 6160 4929 4461 5514 6847 5255 4315 4908 6376 5142 4118 4736 5960 4820 4188
38 4037 5093 6344 4856 4326 5458 7063 5176 4185 4817 6517 5055 3956 4629 6101 4725 4037
39 3877 5014 6529 4771 4194 5400 7282 5090 4054 4723 6657 4958 3790 4506 6241 4629 3877
40 3722 4911 6706 4674 4067 5326 7501 4994 3917 4615 6797 4844 3627 4354 6377 4516 3722
41 3572 4792 6878 4573 3933 5239 7718 4880 3769 4502 6925 4713 3469 4189 6496 4376 3572
42 3422 4666 7055 4447 3794 5139 7908 4752 3623 4376 7054 4567 3327 4036 6597 4233 3422
43 3266 4540 7229 4308 3631 5020 8065 4606 3478 4238 7168 4423 3172 3884 6712 4092 3266
44 3117 4395 7382 4152 3464 4875 8211 4448 3326 4080 7288 4268 3018 3726 6839 3944 3117
45 2966 4239 7534 3980 3307 4701 8337 4270 3165 3926 7403 4104 2867 3570 6952 3783 2966
46 2811 4067 7667 3796 3147 4513 8438 4089 3007 3761 7504 3927 2721 3402 7026 3616 2811
47 2660 3883 7763 3601 2985 4312 8486 3899 2845 3588 7564 3739 2572 3233 7078 3446 2660
48 2504 3690 7820 3415 2818 4099 8471 3700 2688 3392 7563 3551 2437 3061 7112 3276 2504
49 2350 3490 7802 3226 2656 3892 8382 3489 2531 3193 7512 3345 2295 2888 7089 3098 2350
50 2203 3273 7695 3036 2484 3682 8201 3274 2374 3004 7363 3142 2157 2717 7020 2910 2203
51 2059 3054 7512 2835 2308 3455 7937 3059 2210 2806 7147 2938 2018 2540 6892 2720 2059
52 1921 2834 7264 2630 2139 3216 7635 2842 2046 2616 6864 2736 1876 2373 6692 2534 1921
53 1786 2614 6941 2418 1985 2970 7262 2623 1888 2414 6516 2531 1749 2195 6414 2346 1786
54 1653 2402 6562 2216 1840 2721 6839 2403 1761 2218 6139 2328 1628 2015 6086 2162 1653
55 1527 2201 6153 2033 1714 2481 6384 2192 1634 2036 5735 2129 1511 1857 5695 1989 1527
56 1405 2015 5711 1863 1589 2259 5910 1997 1507 1862 5320 1950 1406 1710 5262 1827 1405
57 1303 1831 5238 1701 1464 2056 5409 1825 1404 1724 4851 1798 1306 1577 4827 1675 1303
58 1212 1663 4750 1560 1363 1875 4881 1690 1311 1587 4371 1646 1219 1456 4410 1533 1212
59 1130 1502 4237 1434 1272 1722 4346 1555 1232 1450 3889 1494 1142 1341 3983 1408 1130
60 1052 1368 3734 1325 1201 1569 3809 1420 1159 1341 3423 1367 1078 1236 3547 1292 1052
61 983 1248 3242 1224 1139 1417 3310 1314 1099 1247 2991 1257 1023 1142 3121 1186 983
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
13 / 19
62 926 1144 2781 1140 1086 1301 2858 1221 1050 1160 2599 1163 974 1062 2710 1089 926
63 879 1055 2375 1073 1036 1205 2463 1142 1006 1088 2258 1087 934 999 2334 1007 879
64 840 987 2029 1017 992 1125 2128 1081 966 1027 1953 1022 899 947 2013 948 840
65 802 929 1739 969 957 1061 1883 1032 931 981 1737 972 869 903 1735 895 802
66 766 880 1491 928 922 1008 1638 990 897 943 1520 928 839 865 1496 853 766
67 728 837 1289 894 889 962 1395 951 863 907 1303 884 809 827 1305 810 728
68 690 795 1119 856 856 923 1233 912 830 872 1168 844 778 789 1140 768 690
69 649 753 999 818 823 883 1102 873 795 836 1055 804 744 752 1015 724 649
70 605 709 906 780 788 841 1004 834 758 799 962 765 711 715 915 682 605
71 559 663 847 742 753 800 927 795 720 762 887 726 675 677 849 637 559
72 516 613 789 703 716 760 868 757 680 725 827 687 639 638 784 588 516
73 473 563 730 662 677 718 814 718 638 685 774 647 600 598 718 540 473
74 430 519 678 621 637 676 765 677 592 646 725 606 561 558 664 497 430
75 383 477 622 578 595 633 717 635 544 605 674 564 520 516 605 456 383
76 334 435 559 534 551 589 667 593 491 563 623 522 479 475 544 416 334
77 284 393 492 491 504 545 617 549 435 519 569 481 437 435 473 374 284
78 234 349 432 445 454 501 564 504 377 476 516 439 391 392 410 331 234
79 190 294 379 396 400 454 510 458 319 431 463 393 345 348 357 280 190
80 158 243 328 349 347 403 456 408 268 382 411 350 293 307 309 229 158
81 128 198 276 304 285 356 403 356 233 332 360 307 236 266 258 186 128
82 97 144 212 258 221 310 348 311 206 289 308 264 188 225 199 135 97
83 64 99 158 208 174 264 286 267 180 247 253 221 154 181 146 93 64
84 31 54 102 161 141 218 229 222 154 204 200 179 126 138 95 51 31
85 8 16 55 118 112 173 181 175 129 159 152 137 99 97 53 16 8
86 1 2 21 68 83 125 133 127 102 114 107 93 71 57 20 2 1
87 1 1 3 26 46 63 87 84 67 76 67 53 38 23 3 1 1
88 0 1 1 4 9 17 33 18 12 19 31 17 5 3 1 1 0
89 0 0 1 1 1 1 4 5 4 4 3 1 1 1 1 0 0
90 0 0 0 0 0 1 1 0 0 0 1 0 0 0 0 0 0
91 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
92 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
93 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
14 / 19
94 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
95 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
96 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 0 0
97 0 0 0 0 0 0 1 0 0 0 1 1 0 0 0 0 0
98 0 0 0 0 1 1 1 0 0 0 1 1 0 0 0 0 0
99 0 0 0 0 1 1 1 0 0 0 1 1 0 0 0 0 0
100 0 0 0 0 1 1 1 0 0 1 1 1 0 0 0 0 0
101 0 0 0 0 1 1 1 0 0 1 1 1 0 0 0 0 0
102 0 0 0 0 1 1 1 1 0 1 1 1 0 0 0 0 0
103 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0
104 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0
105 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0
106 0 0 0 0 1 1 1 1 1 1 2 1 0 0 1 0 0
107 0 0 1 0 1 1 2 1 1 1 2 1 0 0 1 0 0
108 0 0 1 0 1 1 2 1 1 1 2 1 0 1 1 0 0
109 0 0 1 0 1 1 2 1 1 1 2 1 0 1 1 0 0
110 0 0 1 0 1 1 2 1 1 1 3 1 0 1 1 0 0
111 0 1 1 1 1 1 2 1 1 1 3 2 1 1 1 1 0
112 0 1 1 1 1 2 3 1 1 1 3 2 1 1 1 1 0
113 1 1 1 1 1 2 3 1 1 2 3 2 1 1 2 1 1
114 1 1 1 1 1 2 3 1 1 2 3 2 1 1 2 1 1
115 1 1 1 1 1 2 3 1 1 2 4 2 1 1 2 1 1
116 1 1 2 1 2 2 3 2 1 2 4 2 1 1 2 1 1
117 1 1 2 1 2 2 3 2 2 2 4 2 1 1 2 1 1
118 1 1 2 1 2 2 3 2 2 2 4 2 1 1 2 1 1
119 1 1 2 1 2 3 3 2 2 2 4 2 1 1 2 1 1
120 1 1 2 1 2 3 3 2 2 2 4 3 1 1 2 1 1
121 1 1 2 1 2 3 3 2 2 2 4 3 1 1 2 1 1
122 1 1 2 2 2 3 3 2 2 3 4 3 1 1 2 1 1
123 1 1 2 2 2 3 3 2 2 3 4 3 1 1 2 2 1
124 1 1 2 2 2 3 3 2 2 3 4 3 1 2 2 2 1
125 1 2 2 2 2 4 3 2 2 3 4 3 1 2 2 2 1
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
15 / 19
126 1 2 3 2 3 4 3 2 3 4 4 3 2 2 2 2 1
127 2 2 3 2 3 4 3 3 3 4 4 4 2 2 2 2 2
128 2 2 3 3 3 4 3 3 3 4 4 4 2 2 3 2 2
129 2 2 3 3 3 4 4 3 3 4 5 4 2 2 3 2 2
130 2 2 3 3 3 5 4 3 3 5 5 4 2 2 3 3 2
131 2 2 3 3 4 5 4 3 3 5 5 4 2 3 3 3 2
132 2 3 3 3 4 5 4 3 3 5 5 4 3 3 3 3 2
133 3 3 3 3 4 5 4 3 4 5 5 5 3 3 3 3 3
134 3 3 3 3 4 5 4 3 4 5 4 5 3 3 3 3 3
135 3 3 3 3 4 5 4 4 4 5 4 5 3 3 3 3 3
136 3 3 3 3 4 5 4 4 4 5 4 5 3 3 3 3 3
137 3 3 3 3 4 5 4 4 4 5 4 5 3 3 3 3 3
138 3 3 3 3 5 5 4 4 4 5 4 5 3 3 3 4 3
139 4 3 3 4 5 5 4 4 4 5 5 5 4 3 3 4 4
140 4 4 4 4 5 5 4 4 4 5 5 5 4 3 4 4 4
141 4 4 4 4 5 5 4 4 5 5 5 5 4 4 4 4 4
142 4 4 4 4 5 5 4 4 5 5 5 5 4 4 4 4 4
143 4 4 4 4 5 6 5 4 5 5 5 5 4 4 4 4 4
144 5 4 4 4 5 6 5 4 5 5 5 5 4 4 4 4 5
145 5 4 4 4 4 6 5 4 5 5 5 5 4 4 4 5 5
146 5 4 5 5 4 6 5 4 5 5 5 5 4 4 4 5 5
147 5 4 5 5 4 6 5 4 5 5 5 6 4 4 5 5 5
148 5 5 5 5 4 6 5 4 5 5 5 6 3 4 5 5 5
149 5 5 5 5 4 6 5 4 5 5 5 6 3 5 5 5 5
150 5 5 5 5 4 6 5 4 5 6 5 6 3 5 5 5 5
151 5 5 5 5 4 6 5 5 5 6 5 6 3 5 5 5 5
152 5 5 5 5 5 5 5 5 5 6 5 6 3 5 5 5 5
153 5 5 5 5 5 5 5 5 5 6 5 6 3 5 5 5 5
154 5 5 5 5 5 5 5 5 5 6 6 5 4 5 5 5 5
155 5 5 5 5 6 5 5 5 5 6 6 5 4 5 5 5 5
156 5 5 5 5 6 5 5 5 5 6 6 5 4 5 5 5 5
157 5 5 5 5 6 5 5 5 5 6 6 5 5 5 5 5 5
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
16 / 19
158 5 5 5 5 6 5 6 5 5 6 6 5 5 5 5 5 5
159 5 5 5 5 6 5 6 5 5 6 6 5 5 5 5 5 5
160 5 5 5 5 6 5 6 5 5 6 6 5 5 5 5 5 5
161 6 5 5 5 6 5 6 5 5 6 6 5 5 5 5 5 6
162 5 5 5 5 6 6 6 5 5 6 6 6 5 5 5 5 5
163 6 6 5 5 6 6 6 5 5 6 6 6 5 5 5 5 6
164 6 6 5 5 6 6 6 5 5 6 6 6 5 5 5 5 6
165 6 6 5 5 6 6 6 5 5 6 6 6 5 5 5 5 6
166 6 6 5 5 6 6 6 6 5 6 6 6 5 5 5 6 6
167 6 6 5 5 6 6 6 6 5 6 6 6 5 5 5 6 6
168 6 6 5 5 6 6 6 6 5 6 6 6 5 6 6 6 6
169 6 6 6 6 6 6 6 6 5 6 6 6 5 6 6 6 6
170 6 6 6 6 6 6 6 6 5 6 6 6 5 6 6 6 6
171 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
172 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
173 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
174 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
175 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
176 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
177 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
178 6 6 6 6 6 5 6 6 6 6 6 6 6 6 6 6 6
179 6 6 6 6 6 6 6 6 5 6 6 6 6 6 6 6 6
180 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
17 / 19
2.2 Electrical, Photometric and Chromaticity Measurements (Refer to Work Instruction QD25)
IES LM-79 2008
Test date 2016-05-19 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number WST-SBL-2-150W(5700K)
Electrical Measurement:
Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %
STD160316
NB-2-G2
120.0 60 1.273 152.2 0.9960 6.87
277.0 60 0.5959 150.6 0.9124 14.01
Sphere-Spectroradiometer Method :
Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 74 R9 0
Frequency (Hz) 60 R2 74 R10 37
Color Rendering Index (CRI) 71.9 R3 72 R11 77
R9 0 R4 74 R12 49
CCT (K) 5693 R5 75 R13 72
Chromaticity (x, y) x=0.3282 y=0.3350 R6 66 R14 84
Chromaticity (u’, v’) u'=0.2063 v'=0.4738 R7 76 R15 69
Duv -0.0012 R8 64 -- --
Total Initial Lumen Output(lm) 16573
Initial Lumen Efficacy(lm/w) 108.89
Sphere-Spectroradiometer Method for 277V:
Parameter Result
Test Voltage (V) 277.0
Frequency (Hz) 60
Total Initial Lumen Output(lm) 16539
Initial Lumen Efficacy(lm/w) 109.82
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
18 / 19
Spectral Power Distribution & Chromaticity Diagram
NVLAP LAB CODE 201011-0
Report No.: STD160316NB-2-G
Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0
Report Format Number STD/QR4909-H/2
Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com
19 / 19
3. Test Equipment
Equipment ID Equipment Name Last Calibration Date Next Calibration Date
ST-R-336 2 meter Integrating Sphere 2015-07-01 2016-06-30
ST-R-331 Spectral analysis system HAAS-2000 2015-07-01 2016-06-30
D204 Standard Lamp 2015-07-01 2016-06-30
PF2010 Power Meter for Integrating Sphere 2015-07-01 2016-06-30
EE-09 Goniophotometer system 2015-07-01 2016-06-30
D908S Standard Lamp 2015-07-01 2016-06-30
PF210 Power Meter for Goniophotometer 2015-07-01 2016-06-30
ST-R-181A Temperature Tester 2015-07-01 2016-06-30
Uncertainty:
Photometric Measurement (Sphere):1.74%
Chromaticity Measurement(Sphere):14.3K
Photometric Measurement(Goniophotometer):1.62%
****** END OF DATASHEET PACKAGE ******