+ All Categories
Home > Documents > LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  ·...

LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  ·...

Date post: 01-May-2018
Category:
Upload: voliem
View: 221 times
Download: 1 times
Share this document with a friend
9
LM-79 Distribution Test Report (Luminaire) Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire Report No.: PHM-RPT-171026-D06 Date: October 26, 2017 Page 1 of 9 LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical Characteristics and Efficacy. Report Prepared for: Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916 USA Telephone: (860) 564-4512 Description : 2” Recessed Downlight Model Tested: V2CRRU-1335K-M WO/CS#: R3243 Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page) Report Reviewed by: Mark Razvi Photometric Lab Supervisor Curtis-Straus
Transcript
Page 1: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 1 of 9

LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution, Electrical

Characteristics and Efficacy.

Report Prepared for:

Vantage Lighting 181 Narragansett Park Drive East Providence, RI 02916

USA Telephone: (860) 564-4512

Description : 2” Recessed Downlight

Model Tested: V2CRRU-1335K-M WO/CS#: R3243

Report Issue Date: October 26, 2017 Date of Test(s): October 24-26, 2017 Total Number of Pages : 9 (including this page)

Report Reviewed by:

Mark Razvi

Photometric Lab Supervisor Curtis-Straus

Page 2: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 2 of 9

DETAILED PRODUCT DESCRIPTION Model # V2CRRU-1335K-M CS/WO# R3243 Description 2” Recessed Downlight Supply Voltage 120VAC Pictures:

Page 3: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 3 of 9

Curtis-Straus Photometric Testing Information

Photometric Testing is performed in accordance with the procedures outlined in LM-79-2008 . The test sample is evaluated for photometric and electrical characteristics using the equipment listed below.

Curtis-Straus Environmental Testing Info Curtis-Straus testing laboratory temperature during testing: 25.7 °C .

LIST OF EQUIPMENT USED: Description Model

No. Serial No. Asset

No Cal. Date

Cal. Due

Yokogawa Power Meter

WT-310E C2SK21021V

2356 12-19-16` 12-19-17

Chroma AC Power Supply

61603 616030001283 2355 04-21-17 04-21-18

LabSphere Type-C GoniometerSystem

PM-150-140 022172153 AA-30058-195

10-17-17 11-17-17

Digital Thermometer

4627 160739886 2392 09-07-16 09-07-18

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

Page 4: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 4 of 9

LM-79-2008 Distribution Test Data

Model # V2CRRU-1335K-M CS/WO# R3243 Description 2” Recessed Downlight Supply Voltage 120VAC

Result of Tests

Photometric and Electrical Test Data

Input Voltage: 120 VAC

Base Orientation: Base Up

Lumens (lm) Watts (W) Volts (VAC) Amps (A) Efficacy PF Ithd (%)

1142.59 14.73 120.21 0.12 77.56 0.9906 0.20

Luminous Intensity Summary: Cd Illumination Cone of Light Mounting Ht: 10 ft.

Page 5: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 5 of 9

IsoCandela Plot

Zonal Lumens Summary Lumens per Zone

Page 6: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 6 of 9

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007 3007

0.1 2979 2983 3034 3053 3047 3021 3024 3020 3033 3020 3007 3020 2986 2981 2954 2968 2985

0.2 2982 2984 3032 3055 3042 3020 3026 3016 3031 3016 3004 3022 2986 2982 2958 2967 2984

0.3 2985 2986 3030 3057 3037 3019 3027 3012 3029 3011 3001 3022 2987 2981 2962 2966 2981

0.4 2989 2989 3026 3054 3033 3021 3026 3007 3024 3010 3001 3020 2989 2979 2965 2966 2978

0.5 2990 2993 3021 3051 3031 3023 3026 3002 3019 3009 3002 3018 2992 2975 2968 2968 2974

0.6 2991 2995 3016 3048 3029 3026 3022 2997 3014 3009 3003 3011 2995 2969 2970 2971 2971

0.7 2991 2996 3014 3042 3029 3025 3018 2995 3010 3012 3005 3005 2997 2964 2967 2973 2970

0.8 2988 2998 3014 3037 3030 3025 3014 2995 3006 3014 3007 2999 2998 2961 2965 2975 2968

0.9 2985 2995 3013 3032 3032 3023 3008 2994 3003 3017 3009 2997 2999 2959 2962 2977 2970

1 2981 2991 3015 3029 3032 3018 3002 2996 3004 3016 3007 2994 2997 2957 2956 2977 2973

1.1 2976 2987 3017 3026 3033 3013 2998 2998 3005 3015 3006 2994 2993 2959 2951 2975 2975

1.2 2971 2982 3018 3026 3033 3008 2996 3000 3006 3013 3002 2996 2989 2961 2948 2973 2976

1.3 2969 2978 3018 3027 3029 3002 2994 2998 3007 3009 2996 2998 2985 2962 2947 2968 2978

1.4 2967 2975 3018 3028 3025 2996 2994 2996 3008 3004 2991 2999 2981 2963 2945 2962 2977

1.5 2966 2975 3016 3029 3020 2993 2996 2992 3005 2999 2985 3000 2977 2964 2947 2957 2974

1.6 2968 2976 3011 3029 3013 2990 2998 2987 3000 2993 2980 3000 2976 2962 2949 2955 2970

1.7 2970 2977 3007 3029 3005 2988 2997 2981 2996 2987 2974 2995 2976 2957 2951 2953 2965

1.8 2971 2979 3002 3025 3000 2989 2995 2975 2988 2984 2974 2990 2975 2953 2951 2953 2960

1.9 2971 2980 2995 3021 2997 2991 2993 2969 2980 2981 2973 2984 2977 2948 2950 2954 2955

2 2971 2980 2989 3015 2995 2992 2986 2962 2973 2979 2973 2977 2978 2942 2948 2956 2951

2.1 2968 2978 2986 3008 2994 2990 2979 2960 2969 2979 2973 2970 2979 2936 2943 2957 2948

2.2 2962 2977 2984 3000 2994 2987 2972 2958 2965 2978 2974 2964 2978 2933 2937 2956 2946

2.3 2956 2971 2982 2995 2994 2984 2966 2956 2963 2978 2973 2961 2976 2931 2932 2956 2947

2.4 2950 2965 2982 2991 2993 2977 2959 2957 2963 2977 2970 2957 2972 2929 2926 2951 2948

2.5 2944 2959 2982 2987 2993 2970 2954 2958 2963 2975 2968 2955 2965 2930 2920 2946 2949

2.6 2938 2953 2982 2987 2991 2963 2950 2957 2962 2972 2962 2954 2958 2931 2919 2940 2948

2.7 2936 2947 2981 2986 2983 2957 2946 2954 2960 2966 2954 2953 2952 2931 2918 2934 2948

2.8 2934 2943 2980 2986 2976 2950 2944 2951 2958 2961 2947 2953 2945 2930 2918 2927 2944

2.9 2933 2942 2975 2984 2968 2947 2944 2945 2952 2954 2940 2952 2939 2930 2918 2921 2940

3 2934 2940 2969 2983 2960 2944 2943 2936 2946 2946 2934 2951 2937 2926 2919 2916 2935

3.1 2935 2940 2963 2980 2952 2941 2940 2928 2939 2939 2927 2944 2934 2920 2918 2912 2927

3.2 2934 2940 2954 2974 2947 2940 2937 2920 2931 2935 2925 2937 2933 2914 2916 2910 2920

3.3 2930 2940 2945 2968 2944 2939 2933 2913 2923 2931 2922 2930 2933 2907 2913 2909 2913

3.4 2926 2937 2937 2960 2940 2937 2926 2907 2915 2928 2920 2922 2934 2900 2908 2908 2909

3.5 2920 2933 2935 2952 2939 2934 2918 2905 2909 2927 2919 2915 2932 2893 2899 2906 2905

Page 7: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 7 of 9

3.6 2912 2929 2932 2943 2938 2930 2910 2902 2904 2925 2917 2909 2928 2889 2891 2904 2902

3.7 2904 2921 2930 2937 2937 2925 2901 2900 2900 2923 2914 2905 2925 2885 2884 2902 2900

3.8 2896 2913 2929 2932 2932 2917 2892 2899 2898 2920 2910 2901 2917 2883 2877 2897 2898

3.9 2889 2906 2928 2927 2927 2910 2887 2898 2896 2916 2905 2899 2909 2882 2870 2892 2896

4 2882 2899 2925 2925 2921 2901 2882 2893 2894 2909 2897 2897 2901 2881 2869 2886 2894

4.1 2880 2893 2921 2923 2911 2891 2878 2886 2890 2902 2888 2894 2894 2879 2869 2877 2892

4.2 2878 2888 2916 2921 2901 2882 2875 2879 2887 2894 2880 2892 2887 2877 2868 2868 2886

4.3 2876 2886 2908 2919 2892 2877 2873 2869 2879 2885 2872 2889 2881 2875 2867 2861 2879

4.4 2874 2883 2899 2916 2884 2872 2870 2860 2870 2875 2864 2884 2878 2869 2866 2855 2872

4.5 2872 2881 2890 2911 2876 2868 2865 2850 2861 2866 2858 2877 2874 2862 2864 2848 2863

4.6 2868 2880 2880 2905 2871 2866 2860 2842 2851 2860 2855 2871 2872 2855 2859 2846 2854

4.7 2862 2877 2871 2898 2868 2863 2853 2834 2841 2853 2853 2862 2870 2847 2855 2844 2846

4.8 2855 2871 2863 2888 2864 2860 2845 2828 2833 2849 2850 2852 2867 2839 2847 2843 2840

4.9 2846 2864 2859 2878 2861 2855 2836 2825 2826 2846 2847 2842 2863 2832 2838 2842 2834

5 2837 2857 2855 2868 2858 2851 2826 2822 2818 2844 2843 2834 2858 2827 2829 2840 2830

5.1 2827 2848 2852 2861 2853 2844 2816 2819 2814 2840 2836 2826 2854 2822 2823 2838 2827

5.2 2821 2839 2849 2855 2845 2836 2805 2815 2810 2835 2829 2819 2844 2819 2816 2831 2824

5.3 2814 2830 2846 2849 2837 2828 2798 2811 2806 2831 2821 2815 2835 2816 2811 2825 2821

5.4 2808 2822 2842 2845 2828 2817 2791 2804 2801 2821 2811 2811 2825 2814 2808 2817 2818

5.5 2805 2813 2837 2842 2818 2805 2785 2796 2796 2811 2802 2808 2816 2811 2806 2808 2815

5.6 2802 2809 2831 2838 2807 2795 2781 2788 2790 2801 2792 2804 2807 2807 2803 2799 2807

5.7 2798 2806 2821 2833 2798 2786 2777 2778 2780 2789 2783 2801 2800 2803 2800 2791 2800

5.8 2794 2803 2811 2829 2789 2778 2773 2767 2771 2778 2774 2794 2795 2794 2796 2784 2791

5.9 2790 2799 2801 2821 2780 2772 2767 2757 2760 2768 2767 2785 2790 2786 2790 2777 2780

6 2783 2794 2791 2812 2776 2767 2762 2748 2749 2760 2762 2776 2786 2777 2782 2773 2770

6.1 2776 2789 2780 2803 2772 2763 2753 2740 2738 2752 2757 2764 2783 2767 2774 2769 2761

6.2 2768 2780 2773 2792 2768 2758 2742 2733 2728 2746 2752 2752 2779 2758 2764 2765 2753

6.3 2757 2771 2768 2780 2762 2753 2731 2726 2720 2740 2747 2740 2772 2751 2754 2760 2745

6.4 2746 2762 2764 2769 2756 2747 2720 2720 2712 2734 2742 2732 2766 2745 2744 2755 2741

6.5 2735 2751 2759 2761 2748 2738 2708 2714 2707 2729 2733 2724 2758 2739 2737 2748 2737

6.6 2727 2741 2755 2754 2737 2727 2698 2709 2703 2723 2723 2717 2748 2735 2731 2738 2733

6.7 2719 2732 2751 2747 2727 2717 2690 2703 2698 2717 2713 2713 2738 2731 2725 2727 2728

6.8 2713 2723 2742 2741 2715 2704 2682 2693 2691 2706 2701 2709 2728 2727 2721 2717 2723

6.9 2708 2715 2733 2735 2703 2692 2676 2683 2683 2696 2689 2704 2718 2720 2718 2706 2716

7 2703 2710 2724 2729 2690 2681 2670 2672 2674 2684 2678 2698 2708 2714 2712 2695 2707

7.1 2698 2704 2712 2722 2682 2671 2664 2660 2662 2671 2668 2693 2700 2707 2705 2687 2697

7.2 2691 2699 2701 2716 2675 2661 2656 2647 2650 2658 2658 2682 2693 2696 2698 2679 2686

7.3 2685 2694 2690 2703 2668 2653 2648 2636 2638 2648 2651 2670 2686 2686 2688 2672 2675

7.4 2676 2689 2679 2691 2662 2647 2641 2626 2626 2639 2645 2658 2682 2676 2676 2667 2663

7.5 2667 2682 2669 2678 2656 2641 2628 2617 2613 2630 2639 2646 2678 2666 2665 2663 2654

Page 8: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 8 of 9

7.6 2657 2671 2662 2665 2649 2634 2615 2610 2604 2623 2633 2633 2673 2656 2653 2657 2646

7.7 2645 2661 2656 2653 2640 2626 2602 2604 2595 2617 2627 2623 2664 2649 2641 2650 2637

7.8 2632 2648 2650 2642 2631 2618 2590 2598 2586 2610 2620 2616 2655 2642 2630 2644 2631

7.9 2621 2636 2643 2635 2620 2606 2577 2589 2579 2601 2607 2610 2645 2636 2624 2634 2626

8 2612 2623 2636 2627 2606 2594 2567 2579 2572 2591 2595 2604 2631 2632 2618 2623 2619

8.1 2602 2613 2629 2621 2593 2581 2559 2569 2563 2581 2582 2598 2617 2627 2612 2613 2613

8.2 2595 2604 2617 2615 2582 2568 2552 2555 2551 2567 2569 2592 2605 2621 2606 2602 2606

8.3 2589 2595 2605 2608 2573 2555 2544 2541 2540 2554 2556 2582 2594 2609 2600 2591 2596

8.4 2582 2589 2593 2598 2563 2546 2537 2528 2528 2542 2547 2569 2583 2597 2589 2580 2583

8.5 2576 2584 2581 2587 2558 2538 2529 2517 2516 2531 2540 2557 2576 2585 2577 2574 2570

8.6 2569 2576 2568 2576 2552 2530 2517 2507 2504 2521 2533 2544 2569 2573 2564 2568 2559

8.7 2561 2566 2559 2562 2545 2523 2504 2499 2493 2513 2524 2530 2562 2560 2552 2560 2547

8.8 2547 2556 2552 2547 2534 2515 2490 2493 2484 2506 2516 2517 2554 2551 2540 2551 2536

8.9 2532 2543 2545 2534 2522 2508 2477 2486 2474 2499 2508 2510 2545 2543 2529 2542 2529

9 2521 2530 2537 2524 2510 2495 2464 2476 2467 2487 2493 2503 2535 2535 2522 2530 2521

9.1 2512 2516 2529 2514 2495 2481 2452 2465 2460 2475 2478 2495 2521 2528 2516 2516 2514

9.2 2503 2505 2521 2505 2480 2467 2443 2454 2452 2463 2465 2488 2507 2520 2509 2502 2505

9.3 2492 2495 2506 2497 2469 2453 2435 2438 2439 2448 2453 2480 2494 2512 2499 2488 2496

9.4 2479 2485 2491 2489 2459 2438 2427 2422 2426 2434 2441 2469 2482 2500 2490 2475 2484

9.5 2465 2477 2476 2477 2450 2427 2418 2407 2412 2421 2431 2455 2470 2487 2477 2462 2469

9.6 2453 2470 2463 2464 2441 2418 2409 2397 2397 2410 2423 2441 2461 2474 2463 2454 2455

9.7 2442 2461 2451 2451 2433 2409 2397 2387 2382 2398 2415 2427 2454 2460 2448 2447 2441

9.8 2431 2450 2440 2435 2424 2401 2382 2378 2370 2389 2405 2413 2447 2446 2437 2440 2429

9.9 2422 2438 2431 2420 2410 2392 2368 2369 2360 2381 2394 2399 2436 2434 2427 2430 2417

10 2414 2425 2423 2405 2396 2383 2354 2361 2351 2373 2382 2390 2424 2425 2416 2420 2408

15 1729 1732 1730 1722 1731 1728 1710 1711 1703 1712 1726 1722 1732 1733 1732 1732 1725

20 1076 1073 1065 1063 1078 1079 1089 1089 1089 1086 1091 1081 1075 1072 1074 1073 1078

25 610 611 606 608 615 618 625 638 629 633 630 616 615 617 612 605 609

30 291 298 292 300 304 309 306 318 310 309 303 303 298 298 298 292 292

35 71 73 75 81 86 88 87 87 83 77 73 72 70 69 69 70 71

40 27 27 28 28 29 28 28 26 26 25 26 26 26 27 27 27 27

45 17 16 17 17 17 17 16 16 15 15 16 16 16 18 18 17 17

50 11 11 11 10 10 10 10 10 10 10 10 11 11 12 12 11 11

55 9 8 8 8 7 8 8 7 8 8 8 8 8 9 10 9 9

60 7 6 6 6 6 6 6 6 6 6 6 6 6 6 7 7 7

65 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

70 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 4 5

75 5 5 5 5 4 5 4 5 5 5 5 5 5 5 5 5 5

80 4 4 4 4 4 4 4 5 4 4 4 4 5 4 4 4 4

85 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

Page 9: LM-79 Distribution Testing: Total Luminous Flux, Luminous Intensity Distribution ... ·  · 2017-11-26Total Luminous Flux, Luminous Intensity Distribution ... 0.8 2988 2998 3014

LM-79 Distribution Test Report (Luminaire)

Total Luminous Flux, Luminous Intensity Distribution and Electrical Characteristics of Customer Submitted Luminaire

Report No.: PHM-RPT-171026-D06 Date: October 26, 2017

Page 9 of 9

90 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

95 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

100 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

105 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

110 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

115 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

120 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

125 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

130 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

135 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

140 4 4 4 3 3 3 3 3 3 4 3 3 3 3 4 4 4

145 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

150 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

155 5 5 5 5 5 5 5 5 5 5 4 4 5 5 5 5 5

160 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

165 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

170 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5

175 5 5 5 5 5 5 5 5 5 5 5 5 6 5 5 5 5

180 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5


Recommended