LDC Load Distribution Center La Marche Mfg. (A U.S. Company) 106 Bradrock Drive, Des Plaines, IL 60018 Tel: 847.299.1188 Fax: 847.299.3061 [email protected] www.lamarchemfg.com Specifications subject to change without notice P25-DSLDC-1 ECN 20715 02/15 Load Distribution Center 8 Position 400 amp bus rating Main Breaker up to 400A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250, 300, 400 4 positions for Branch Breakers from 125-250A Available breaker ratings: 125, 150, 175, 200, 225, 250 4 positions for Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 La Marche LDC delivers the highest level of circuit protection and offers a robust and innovative configuration that simplifies any installation. It is available in four different models: 8, 12, 20, and 24 circuit breaker positions, with the option to include a main breaker. The LDC breakers are 2 pole, 250 VDC and minimum 10 kAIC rated. Loads are connected directly to the breaker, in order to establish a more secure and reliable connection. The field installable breaker kits makes future expansion much simpler. In order to prevent accidental contact, the enclosure includes a hinged front access door and protective front cover. Door Removed Breaker Cover Removed 12 Position 250 amp bus rating Main Breaker up to 250A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250 Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 20 Position 400 amp bus rating Main Breaker up to 400A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250, 300, 400 4 positions for Branch Breakers from 125-250A Available breaker ratings: 125, 150, 175, 200, 225, 250 16 positions for Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 24 Position 250 amp bus rating Main Breaker up to 250A Available breaker ratings: 125, 150, 175, 200, 225, 250 Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 Standard Features UL 489 Listed Breakers 250 VDC @ 10 KAIC NEMA 1 Enclosure 8, 12, 20, 24 Positions Top/Bottom Conduit Entry OPTIONAL: (48N) No Conduit Holes
Transcript
Page 1: Load Distribution Center - La MARCHEweb.lamarchemfg.com/userfiles/P25-DSLDC-1.pdf · Load Distribution Center ... Tel: 847.299.1188 Fax: 847.299.3061 sales@lamarchemfg.com ... nch

LDCLoad Distribution Center

La Marche Mfg. (A U.S. Company)106 Bradrock Drive, Des Plaines, IL 60018

Tel: 847.299.1188 Fax: [email protected]

Specifications subject to change without noticeP25-DSLDC-1ECN 2071502/15

Load Distribution Center

8 Position• 400 amp bus rating• Main Breaker up to 400A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250, 300, 400

• 4 positions for Branch Breakers from 125-250A Available breaker ratings: 125, 150, 175, 200, 225, 250

• 4 positions for Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100

La Marche LDC delivers the highest level of circuit protection and offers a robust and innovative configuration that simplifies any installation. It is available in four different models: 8, 12, 20, and 24 circuit breaker positions, with the option to include a main breaker. The LDC breakers are 2 pole, 250 VDC and minimum 10 kAIC rated. Loads are connected directly to the breaker, in order to establish a more secure and reliable connection. The field installable breaker kits makes future expansion much simpler.

In order to prevent accidental contact, the enclosure includes a hinged front access door and protective front cover.

Door Removed Breaker Cover Removed

12 Position• 250 amp bus rating• Main Breaker up to 250A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250

• Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100

20 Position• 400 amp bus rating• Main Breaker up to 400A Available breaker ratings: 100, 125, 150, 175, 200, 225, 250, 300, 400

• 4 positions for Branch Breakers from 125-250A Available breaker ratings: 125, 150, 175, 200, 225, 250

• 16 positions for Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100

24 Position• 250 amp bus rating• Main Breaker up to 250A Available breaker ratings: 125, 150, 175, 200, 225, 250

• Branch Breakers up to 100A Available breaker ratings: 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100

Standard Features• UL 489 Listed Breakers • 250 VDC @ 10 KAIC• NEMA 1 Enclosure • 8, 12, 20, 24 Positions• Top/Bottom Conduit Entry

OPTIONAL: (48N) No Conduit Holes

Page 2: Load Distribution Center - La MARCHEweb.lamarchemfg.com/userfiles/P25-DSLDC-1.pdf · Load Distribution Center ... Tel: 847.299.1188 Fax: 847.299.3061 sales@lamarchemfg.com ... nch

LDC - M100 - 12 - 20 - XXXXX

Model NumberMain Breaker Rating

M0 = No Main BreakerBreaker Positions

Custom Configuration CodeBreaker Combination Code

Breaker Positions8, 12, 20, 24

Model Number Nomenclature

Ordering InformationWhen Ordering, Please Specify:

- La Marche Model Number

- Number of Breaker Positions

- Main Breaker Rating

- Branch Breakers Ratings

- Optional Accessories

La Marche Mfg. (A U.S. Company)106 Bradrock Drive, Des Plaines, IL 60018

Tel: 847.299.1188 Fax: [email protected]

Dimension Chart

Circuit BreakerPosition

Overall Dimensions(H x W x D)24” x 24” x 6.75”

610mm x 610mm x 170mm

24” x 24” x 6.75”610mm x 610mm x 170mm

8

12

20

24

36” x 24” x 6.75”914mm x 610mm x 170mm

36” x 24” x 6.75”914mm x 610mm x 170mm

400

A Bu

s Bar

400

A Bu

s Bar

400

A Bu

s Bar

4

2

8

6

7

5

Branch 125A - 250A

Branch 125A - 250A

Branch 125A - 250A

Branch 125A - 250A3

1

Main Breaker up to 400A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

8 Position

250

A Bu

s Bar

250

A Bu

s Bar

8

6

4

21

3

5

9

11 12

10

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Main Breaker up to 250A

250

A Bu

s Bar

12 Position

7

400

A Bu

s Bar

Branch 125A - 250A

Branch 125A - 250A

400

A Bu

s Bar

400

A Bu

s Bar

400

A Bu

s Bar

13

15

17

19

14

16

18

20

400

A Bu

s Bar

9

11

10

12

1

3

5

7

2

4

6

8

Branch 125A - 250A

Branch 125A - 250A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

400

A Bu

s Bar

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Main Breaker up to 400A

20 Position

250

A Bu

s Bar

250

A Bu

s Bar

250

A Bu

s Bar

250

A Bu

s Bar

250

A Bu

s Bar

250

A Bu

s Bar

Main Breaker up to 250A

14

16

18

20

22

24

13

15

17

19

21

23

2

4

6

8

10

12

1

3

5

7

9

11

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

Branch up to 100A

24 Position


Recommended