SITE LOCATION (SCALE 1:1250)
SITE LOCATION
SITE LOCATION (SCALE 1:25000)
LOCATION PHOTOGRAPH
THESE DRAWINGS COMPLY WITH STANDARD ICNIRP DESIGN GUIDELINES.
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
SITE LOCATION
050m 100m 150m
SCALE 1:1250
2500m2000m0
1500m1000m500m
SCALE 1:25000
CAR PARK
BLACKWALL BASIN
WATER
T
R
A
F
A
L
G
A
R
W
A
Y
CRT BRIDGE CONTROL
BUILDING
EXISTING 2.4m HIGH
PALISADE FENCING
OUTLINE OF ROAD
BRIDGE OVERHEAD
ACCESS
TO SITE
EXISTING STAIRS
UP TO ROAD
OVERHEAD
EXISTING SITE LAYOUT PLAN (SCALE 1:250)
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
THESE DRAWINGS COMPLY WITH STANDARD ICNIRP DESIGN GUIDELINES.
0 5m 10m
SCALE 1:250
15m 20m
CAR PARK
BLACKWALL BASIN
WATER
T
R
A
F
A
L
G
A
R
W
A
Y
CRT BRIDGE CONTROL
BUILDING
EXISTING 2.4m HIGH
PALISADE FENCING
OUTLINE OF ROAD
BRIDGE OVERHEAD
ACCESS
TO SITE
EXISTING STAIRS
UP TO ROAD
OVERHEAD
PROPOSED 3No. ANTENNAS TO BE POLE
MOUNTED TO 17.5m HIGH NEW SQUARE LATTICE
TOWER ON NEW SCREW PILED FOUNDATION
PROPOSED EQUIPMENT CABINETS TO BE
MOUNTED ON CONCRETE BASE.
PROPOSED SITE LAYOUT PLAN (SCALE 1:250)
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
THESE DRAWINGS COMPLY WITH STANDARD ICNIRP DESIGN GUIDELINES.
0 5m 10m
SCALE 1:250
15m 20m
0.00m GL
EXISTING CANAL AND RIVER TRUST
BRIDGE CONTROL BUILDING
EXISTING BUILDINGS TO REAR
EXISTING SOUTH-EAST ELEVATION (SCALE 1:100)
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
THESE DRAWINGS COMPLY WITH STANDARD ICNIRP DESIGN GUIDELINES.
SCALE 1:100
0 6m5m4m3m2m1m 7m 8m 9m 10m
EXISTING CANAL AND RIVER TRUST
BRIDGE CONTROL BUILDING
EXISTING BUILDINGS TO REAR
0.00m GL
TOP OF ANTENNAS
20.00m AGL
PROPOSED 3No. ANTENNAS
TO BE POLE MOUNTED TO 17.5m
HIGH NEW SQUARE LATTICE TOWER
ON NEW CONCRETE FOUNDATION
PROPOSED 2No. DISHES TO BE
MOUNTED TO TOWER ON NEW
SUPPORT STEELWORK
PROPOSED SOUTH-EAST ELEVATION (SCALE 1:100)
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
THESE DRAWINGS COMPLY WITH STANDARD ICNIRP DESIGN GUIDELINES.
SCALE 1:100
0 6m5m4m3m2m1m 7m 8m 9m 10m
WATER
EXISTING 2.4m HIGH PALISADE
FENCING
BILLINGSGATE MARKET CAR PARK
SITE ACCESS ROUTE UNDER
BRIDGE. MAX CLEARANCE 5m
TO UNDERSIDE
CANAL AND RIVERS TRUST
FENCED COMPOUND WITH
STONE FINISH
EXISTING CANAL AND RIVERS
TRUST BRIDGE CONTROL
BUILDING
PROPOSED OUTDOOR ELTEK PSU TO BE
MOUNTED ON NEW CONCRETE BASE
PROPOSED 2No. NSN FLATPACK FRAMES
TO BE MOUNTED ON NEW CONCRETE BASE
PROPOSED 450mm OVERHEAD CABLE
TRAY ON SUPPORT POLES
PROPOSED 2.4m HIGH PALISADE
FENCED COMPOUND WITH 1m WIDE
PERSONNEL ACCESS GATE
PROPOSED 3No ANTENNAS TO BE POLE
MOUNTED TO NEW 17.5m HIGH SQUARE
LATTICE TOWER ON SCREW PILE FOUNDATION
EXISTING 800mm HIGH x
215mm WIDE BRICK WALL
PROPOSED ELECTRICAL METER
PILLAR WITHIN FENCE LINE
PROPOSED SPACE FOR FUTURE EQUIPMENT
ENLARGED LAYOUT PLAN (SCALE 1:100)
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
SCALE 1:100
06m5m4m3m2m1m 7m 8m 9m 10m
GL
17500
20000
2500
PROPOSED TYPE 1S SQUARE
LATTICE TOWER COMPLETE
WITH ANTI-CLIMB AND FIXED
LADDER
PROPOSED 3No. ANTENNAS
POLE MOUNTED TO HEADFRAME
180°
300°
60°
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
PROPOSED TOWER ELEVATION (SCALE 1:100)
PROPOSED ANTENNA PLAN (SCALE 1:25)
A=
1=
ANTENNA GROUP (A-Z)
CELL No. (1, 2, 3)
b= UNIQUE BAND REFERENCE
1=
U=
SECTOR (2,3 etc)
UMTS (G=GSM) (L=LTE)
21= 2100 BAND (09=0900,18=1800)
NEW =
ON SITE AND NOT BEING MOVED
ON SITE BUT BEING MOVED
EXISTING =
RE-USE =
VF = VODAFONE
TELEFONICA
TEF =
NEW ONTO SITE
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
EQUIPMENT SCHEDULE
OPERATOR MANUFACTURER TYPE SIZE COLOUR COMMENTSSTATUS
POWER SUPPLY SOURCE
OPERATOR MANUFACTURER TYPE SIZE COLOUR COMMENTSSTATUS
TEF TFL METER PILLAR 378x171x868 BLACK NEW REC SUPPLYPROPOSED
PROPOSED
TEF STANDARDNSN FLEXI BTS 560x490x625
TRANSMISSION ENCLOSURE
U SPACE
AVAILABLE
CURRENT
TRANSMISSION
KIT LOCATION
TRANSMISSION INTER-CABINET CABLING
CABLE
LENGTH
RADIO
CONNECTION
CABLE TYPE
TRANSMISSION
CONNECTION
TRANSMISION SOLUTION
MICROWAVE ONLY/FIBRE ONLY (WITH PROVIDER NAME)/
MICROWAVE + FIBRE (WITH PROVIDER NAME)
PROPOSED
TRANSMISSION
KIT LOCATION
COMMENTS
6 - X 16 CORE COAX 6m SMB SOCKET BNC PLUGMICROWAVE + FIBRE -
ENCLOSURESTATUS
PROPOSED ELTEK PSU
TEF STANDARDPROPOSED NSN 42U FLATPACK FRAME 600x600x2000 2No. UNITS TO HOUSE TEF FLEXI MODULES
TEF STANDARD TO HOUSE TRANSMISSION AND PROVIDE DC POWER TO TEF FLEXI MODULES
PROPOSED
ELTEK PSU 700x820x1800
CONFIGURATION: TEF NSN - 3 SECTORS, 2 ANTENNASRF CONFIG: LGD-S-M-E1c-F
MODULES TO BE HOUSED WITHIN FPF'S
DISH KEY
OPERATOR DISH REF
HEIGHT
TO C/L
COLOUR COMMENTSDISH DIA
TEFD1
600 TBC --
BEARING LOCATION
EXTERNAL STANDARD
STATUS
PROPOSED
TEF
D2
600 TBC-
EXTERNAL STANDARDPROPOSED -
SUPPORT STRUCTURE KEY
HEIGHT MANUFACTURER TYPE
COLOUR (INCLUDE RAL CODE IF
NON STANDARD) & FINISH
COMMENTS
17.5m SWANN SQUARE LATTICE TYPE 1S GALVANISED -PROPOSED
STATUS
NEW
EXISTING/PROPOSED
STREEWORKS
HATCH HEIGHT
ABOVE G/L
-
STREEWORKS
HATCH HEIGHT
BEARING
-
STREEWORKS*
USE EXISTING
ROOT
-
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
ANTENNA SCHEMATIC
LGD-S-M-E1c-F
ANTENNA 1
A19
M2 21 MHA
U21 RFM
LOW 1
65°
HIGH 1
65°
HIGH 2
65°
COMMSCOPE
CVV2NPX308.208R
U09 RFM
HIGH 1
33°
HIGH 2
33°
ANTENNA 2
(FUTURE)
A18
LOW 1
33°
LOW 2
33°
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
PROPOSED ICNIRP PLAN (SCALE 1:200)
02m 4m 6m 8m 10m
SCALE 1:200
0.00m GL
0.3
m
6.22m
max
6
0
°
6
0
°
0
.
3
m
2.55m
0.3m
0.3m
6.22 max
Standing Level
Limit of occupational
exclusion zone
10.8m min to 17.41m max
0.3m
2.3m
2.3m
Limit of public
exclusion zone
Standing Level
14° m
ax
2.69m
m
in to
4.3m
m
ax
6
0
°
6
0
°
0
.
3
m
0.3m
10.8m min to
17.41m max
Antenna Direction
C
THIS DRAWING IS THE COPYRIGHT OF NET COVERAGE
SOLUTIONS LTD AND MAY NOT BE REPRODUCED OR
DISCLOSED TO A THIRD PARTY IN ANY FORM WITHOUT
WRITTEN PERMISSION
NET COVERAGE SOLUTIONS
CRAVEN COURT
STANHOPE ROAD
CAMBERLEY
SURREY GU15 3BS
TEL: +44(0)1276 854440
FAX: +44(0)1276 854450
CTIL
PROPOSED ICNIRP ELEVATION (SCALE 1:250)
BEACON PUBLIC EXCLUSION ZONELONDON TEF ONLY (NTS)
BEACON OCCUPATIONAL EXCLUSION
ZONE LONDON TEF ONLY (NTS)