5
LCP combi-hole: angular stable locking and/or compression Angular stability independent of bone quality Support of biological osteosynthesis even in the case of complex fractures and osteoporosis Locking Compression Plate. Combine without Compromise.
Transcript
  • LCP combi-hole: angular stable locking and/orcompression

    Angular stability independentof bone quality

    Support of biological osteosynthesis even in thecase of complexfractures and osteoporosis

    Locking Compression Plate.Combine without Compromise.

  • LCP Locking Compression Plate

    LCP Locking Compression Plate. Combine without Compromise.

    Angular stable support of fragments regard-less of bone quality

    Reduces the risk of primary and secondaryloss of reduction even under high dynamicloading

    Reduced impairment of periosteal bloodsupply due to limited plate-periosteum con-tact

    Favorable hold also in osteoporotic boneand in multiple fragment fractures

    Angular stable implant

    – Stability of the implant regardless of bonequality; supply stability slightly dependenton bone quality

    – Locking screws can be placed in eachhole of the plate

    Because the screws are tightly locked in theplate:– There is no tension on the bone– Compression is eliminated between the

    plate and bone– The periosteum is undamaged and circula-

    tion is retained

    The plate does not have to be preciselyshaped to the bone to provide stability. Mini-mally invasive surgery (MIS) is easy to per-form:– The soft tissue and the wound hematoma

    are treated gently– Optimum circulation is maintained

  • A

    B

    FF

    Reduction maintained under a load LCP combi-hole

    – Stable bridging of comminuted fractures– The stable plate-screw connection de-

    creases secondary loss of reduction in theepiphyseal and metaphyseal regions

    – The screws are locked in the plate, andthe physiological load (F) is transferredfrom the bone to the plate

    – The fragments are fixed in their reducedposition without regard to the platemodel (internal fixator)

    – The bone fragments are reliably fixed inthe position assumed at the time thescrews are locked

    A Stable plate-screw connection– Locking screws reduce screw loosening– Excessive torque is not applied to the

    cortical bone– The conical screw head makes it easy to

    insert the screw

    B Compatibility– The proven dynamic compression hole

    allows you to use all standard screws

    Self-tappinglocking screws

    – Use after precisely measuring the length(metaphysis)

    – Monocortical or bicortical use– Not necessary to separately tap thread

    Self-drillinglocking screws

    – Use without having to precisely measurethe length (diaphysis)

    – Only for monocortical use– Tapping and predrilling are unnecessary

    Standard screws

    – Dynamic compression is created by theeccentric insertion of the standard screws(analogous to LC-DCP)

  • 01230123 036.

    000.

    018

    SE_0

    2351

    1 A

    B31

    0500

    14©

    Syn

    thes

    2006

    LCP

    and

    Com

    pact

    Han

    d ar

    e tr

    adem

    arks

    of

    Synt

    hes

    Subj

    ect

    to m

    odifi

    catio

    ns

    Presented by:

    Positive influence on healing

    LCP Locking Compression Plate. Combine without Compromise.

    – The locking screws enable the anatomi-cally-preformed plates to be fully effective

    – The use of LCP implants enables early andactive mobilization, even in the caseof complex epimetaphyseal fractures andosteoporosis

    – With its line of LCP implants, Synthesoffers a large selection of speciallyadapted plates for a broad spectrum ofindications

    Case study: 55-year-old patient with AO Type 13-C1.2 fracture, treatment with LCP double plate technique(source: Dr. Ch. Ryf, Hospital Davos)

    Preoperative

    Postoperative

    4 weeks postoperative

  • Combine without Compromise. Locking Compression Plate.

    Radius/Ulna

    LCP Olecranon Plate

    LCP Distal Radius System 2.4

    Foot

    Calcaneus Locking Plate*

    X Locking Plate* 2-Hole Locking Plate*

    TomoFix (for osteotomies)

    LCP Proximal Lateral Tibia Plate

    LCP Distal Femur Plate

    LCP Distal Tibia Plate

    LCP Pilon Plate

    LCP Distal Humerus Plate

    Wrist Fusion Plate

    LCP Condylar Plate

    Tibia

    LCP Proximal Tibia Plate 3.5 and 4.5

    Femur

    LCP Broad Curved

    Humerus

    LCP Proximal Humerus Plate/ PHILOS

    Clavicle

    LCP Clavicle Hook Plate

    Hand

    LCP Compact Hand

    LCP Metaphyseal Plate for thedistal medial tibia

    *no combi-holeAll plates are available in stainless steel.

    LCP Metaphyseal Plate for the distal medial humerus

    LCP Locking Compression Plate.

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 150 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.10000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 600 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.10000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects true /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName /PDFXTrapped /False