+ All Categories
Home > Documents > LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition &...

LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition &...

Date post: 06-Mar-2018
Category:
Upload: hadung
View: 270 times
Download: 9 times
Share this document with a friend
31
LS FA Cable LS FA Cable
Transcript
Page 1: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

LS FA CableLS FA Cable

Page 2: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

Contents

1. Definition & Requisitions of FA/Robot Cables

2. FA Cables Characteristics per each applicable part

3. Trend of FA Cables

4. Characteristics & Construction of LS FA/Robot Cables

5. Factors of life span in the moving parts of FA/Robot

6. Characteristics of LS FA/Robot Cables

7. Selection of LS FA/Robot cable materials

8. Installation method of FA/Robot Cables

9. Life span Test Method of LS FA/Robot Cables

10. Major Supply history of LS FA/Robot Cables

11. Bus Cable

12. Certifications of LS FA/Robot Cables

13. Cable Comparison Table (Other Cable Companies vs. LS Cable)

Page 3: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

1. Definition & Requisitions of FA/Robot Cables

Cables for Industrial Robotics and Factory Automation Tools

Requires high flexibility and reliability for bending and twisting in the moving parts

NCLINE-S Series

NCLINE-M Series

ROBOLINE-S Series

ROBOLINE-M Series

Special FA Cable

Signal Transmission, Motor Control / Fixed Parts

Signal Transmission, Motor Control / Minutely Moving Part

Power Supply, Motor Control / Fixed Parts & Minutely Moving Part

Moving Part (Reciprocation, Twist, Right & Left Bendings)

Applicable to special use (Joint Development with customers)

Page 4: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

2. FA Cable Characteristics per each applicable part

Part Required Characteristics

ACables highly resistant to bending

and twisting & Curl Cable

BCables resistant to bending and

twisting

CFlexible cables for easier control

and handling

D Fixed flexible cable connecting

robotics and control unit

Page 5: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

3. Trend of FA Cables

Environment Environment Environment Environment

friendlyfriendlyfriendlyfriendly

Environment Environment Environment Environment

friendlyfriendlyfriendlyfriendly

LeadLeadLeadLead----

FreeFreeFreeFree

RoHSRoHSRoHSRoHS

HalogenHalogenHalogenHalogen

----FreeFreeFreeFree

Change of Change of Change of Change of

cable materialscable materialscable materialscable materials

Change of Change of Change of Change of

cable materialscable materialscable materialscable materials

GeneralGeneralGeneralGeneral

PVCPVCPVCPVC

SpecialSpecialSpecialSpecial

PVCPVCPVCPVC

UrethaneUrethaneUrethaneUrethane

Eng.Eng.Eng.Eng.

PlasticsPlasticsPlasticsPlastics

GeneralGeneralGeneralGeneral

PEPEPEPEIrradiated PEIrradiated PEIrradiated PEIrradiated PE

TeflonTeflonTeflonTeflon

Page 6: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

4. Characteristics & Structure of LS FA/Robot Cables

LS Cable rapidly develops cables conformable to characteristic and structure

required by the customers.

Cable NameItem

COVV(-SB)1

ROVV(-SB)2

ROVVU(-SB)3

ROIREU(-SB)(Halogen free)

4

ROIREVU(-SB)(Halogen free)

5

ROFHV(-SB)

ROFHU(-SB)6

ROFHVU(-SB)7

Application

Fixed Part

Moving Part

Moving Part

Moving Part

Moving Part

Moving Part

Moving Part

Insulation

Special PVC

Special PVC

Special PVC

Irradiated PE (XLPE)

Irradiated PE (XLPE)

Fluorine Resin

Fluorine Resin

Sheath

Special PVC

Special PVC

Polyurethane(TPU)

Polyurethane(TPU)

Polyurethane(TPU)

Special PVC,

Polyurethane(TPU)

Special PVC,

Polyurethane(TPU)

ROTPEU(-SB)(Halogen free)

8 Moving PartTPE-E Compound

(Thermoplastic elastomer)

Polyurethane

(TPU)

Page 7: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

5. Factors of cable life span in the moving part

Selection of Materials

Conductor

Insulation

Sheath

Manufacturing Method

Twist Direction & Pitch

Direction of conductor

assembly & Pitch

Subsequent treatment of Insulation

Pair Pitch

Braid Shield Pitch

Manufacturing method of Sheath

•The best fitted application of the pitch of inner insulated wires improves flexibility of the cables and prevents

“Kink phenomenon” of the inner insulated wires during repeated movement.

•Pitch of the assembled inner wires which forms each layer of combined process affects life span of

the cables for the moving part.

Page 8: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

5. Factors of FA/Robot life span in the moving part

Installation method of the cables

Process method of Connecting Work

Motion Condition of the cables→→→→ Motion Velocity, Stroke Length, The Radius of Curvature

Page 9: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

6. Characteristics of LS FA/Robot Cables

Excellent in flexibility and bending characteristic by using ultra-thin cable,

specially constructed conductor and special insulation material

Low coefficient of friction in insulation and Excellent in mechanical characters in moving part

( High creditability for long hours of motion by the application of ETFE)

Excellent in electrical shield and prevention of EMI

Excellent cold-resistant, oil-resistant and abrasion-resistant by using special PVC and

polyurethane to Sheath

High flexibility by using special design method

Insulation

Conductor

Binder Tape

Braid shield

Sheath

Halogen Free “TPE” Cables with the low coefficient of friction

& excellent mechanical durability in moving parts

Page 10: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

7. LS FA/Robot,Selection of cable materials (Insulation)

Material Name Poly Vinyl Chloride Polyethylene Irradiated

Polyethylene

Thermoplastic

elastomer Fluorine Resin

Code PVC PE IRE (XLPE) TPE(-E) FH

Temperature Range

() 60∼∼∼∼105 75 90~125 90~150 150~200

Insulation Resistance O

Flammability O X O

Low Toxic X

Cold Resistance O

Durability O O

Frictional Resistance O O

Mechanical Strength O

Soldering Work O

Application ·Fit for fixed part ·Fit for moving part

·In the parts of high bending stress ※※※※ We recommend ETFE fluorine material to be applied in the parts of high bending stress,

1) Low Friction

2) Hard and toughness

3) High Kink resistance

4) High tensile strength

※※※※ : Excellent, O : Good, : Not bad, X : Bad

Page 11: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

7. LS FA/Robot, Selection of the cable materials (Sheath)

Material Name Poly Vinyl Chloride Special Poly Vinyl

Chloride

Flame Retardant

Polyurethane

HALOGEN

FREE

Flame Retardant

Polyurethane

Code PVC PVC TPU HFPU

Application Fixed Part Moving Part Moving Part Moving Part

Durability O

Cold-Resistance O

Mechanical Strength O O

Oil-Resistance O

Flammability O O O O

Low Toxic X X O

Abrasion-Resistance O O

Bending O

Criterion of

selection

·Fit for fixed part

·Most general

material for sheath

·Moving part

·Material for requiring

flexibility

·Moving part

·Oil resistance,

Cold resistance

·Moving part

·Flammability,

.Oil-Resistance,

Cold-Resistance

Page 12: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

7. LS FA/Robot, Selection of the shield materials (Shield type)

2 4 6 8 10

0

10

20

No. of Bending cycles

(Unit : million)4

Mixed(Copper & Cotten yarn) Braid Shield

Tinsel Copper Braid Shield

Tinned Copper

(or Annealed Bare Copper)

Braid Shield

Wound type applied,

Excellent in shield-function,

flexibility, durability for long

moving.

Though shield function is less

than tinned conductor,

abrasion resistance is excellent.

No decrease of shield function

for long motion

Good Shield function in first stage,

But when bended for long time,

shield function rapidly down

Feature

Intensively moving part

Part requiring high flexibility

Moving PartFixed & Moving PartApplication

Tinsel Braid ShieldMixed Braid ShieldTinned or Annealed

Braid Shield Type

Shield Type

Shield

Resistance

Increase

Rate(%)

Page 13: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

8. FA/Robot, Installation Method of the cables(The Bending radius(R))

Cable for Fixed part

Cable for Power supply Cable for Moving Part

Classification

Single Core Multi Core

Cable for

Control Under 15 Cores Over 15 Cores

Shielded

Non Shielded

8 D

12 D

6 D

12 D

8 D

12 D

10 D

15 D

15 D

20 D (Conductor Size Over 0.75SQ, D : Cable Out-diameter)

Cable for Fixed Part

Cable for Power supply Cable for Moving Part

Classification

Single Core Multi Core

Cable for

Control Under 15 Cores Over 15 Cores

Shielded

Non Shielded

-

-

-

-

-

-

7.5 D

10 D

10 D

15 D (Conductor Size Less 0.75SQ, D : Cable Out-diameter)

R

Cables should not be bended exceeding allowed scope of the

radius of curvature conformity to the cable structure.

When excessively bended, insulation is cracked by fiery heat

caused by the longitude difference on the same circumference

Especially, it affects life span of the cables in the moving part.

※ Reference Data : ICEA International Cable Engineering Association

Page 14: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9. Life span test method of LS FA/Robot Cables

90 Left & Right Bending Test

Shift Bending Test (U-Bend)

Twist(Torsion) Test

Bending & Twist(Torsion) Test

Page 15: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.1 FA/Robot, Life span test, Evaluation criterions

External Appearance & Existence of Cable short

Abrasion state of cable sheath, Existence of Crack occurrence The number of test Operation times => 10 ~ 20 Millions times

Change rate of Conductor Resistance (Shield type includes shield-resistance)

Check change rate of conductor resistance every 1 Million times of motion

Mechanical Characteristics

Check the change of Tensile Strength and Elongation Rate after operatinginsulation and sheath material

Electrical Test

AC Voltage test & Allowable Current Test

Page 16: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

90 Left & Right Bending Test

①③②④

Sample

Load

AxisMandrel

1 Cycle : ①→②→③→④①→②→③→④①→②→③→④①→②→③→④

Velocity : 40 Cycles/Minute

Load : 500 gf (Variable)

Mandrel Diameter : Adjustable

(Bending radius)

9.2 LS FA/Robot, Cable life span, test method

Page 17: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.2 LS FA/Robot, Cable life span, test method

Shift Bending Test (U-Bend)• Bending radius(R): Adjustable variously

• Velocity : Average 2.0m/s

• Bending cycles : Average 80 Cycles/Minute

(Max. 100 Cycles/Minute)

• Acceleration : 2G (20 )• Stroke length : 1,500

Page 18: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.2 LS FA/Robot, Cable life span, Test method

Torsion(Twist) Test • Torsion cycles : Average 60 cycles / Minute

(Max. 100 cycles / Minute)

• Torsion Angle : Max. ±±±± 540˚

• Cable Length : 1000mm

• Load : 250 gf (Variable)

Rotation

Specimen

Fixture

Page 19: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.2 LS FA/Robot, Cable life span, Test method

Bending & Twist(Torsion) Test Test for the simultaneous motions for requiring bending and twisting

such as arm of the welding robotics

Bending Test

Torsion Test

Simultaneously performing 2 tests in 1 test

equipment (Bending & Twisting)

Torsion cycles : Average 60 cycles / Minute

Torsion Angle : Max. ±±±± 360˚

U-bending speed : 2.0m/s (Acceleration : 2G)

Bending radius : Variable

Cable Length : 1000mm

Page 20: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.3 LS FA/Robot, Result of life span test comparing with the cables of competing companies

1. Condition : Simultaneous Motion

→→→→Twist + Shift Bending

2. Twist Test Condition :

- Twist Angle : 360 degree

- Twist Velocity : 63.5 Times/1 Minute

3. Shift Bending Condition:

- The radius of curvature (R) : 67mm

- Shift Velocity : 63.5 Times/1 Minute

- Stroke : 195mm

4. Applied Electric Current : 300mA

Twist & Bending Test Condition

5

10

15

Competing

Company(A)

Competing

Company(B)

24,000 Times 34,000 Times

LSC

140 Thousand Times

(LS Model Name :ROFHV-SB 8PX0.2SQ)

(* Same Type of Cable 8PX0.2SQ)

Bended

Times

(10,000

Times)

Page 21: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

9.3 LS FA/Robot, Test result comparing with the cables of competing companies

1. Condition : Shift Bending(U-Bend)

2.Test Condition

1)Velocity : 2.5m/s

2)Shift Range : 1,200mm

3)Target : 15 Million times

4)The radius of curvature

: 120¢¢¢¢, 100¢¢¢¢ (2 conditions)

5)Cable Name : ROFHU-SB 9CX2SQ

3. Evaluation Items

- External Appearance

- Conductor Resistance

(3 Million Times / Test)

- Voltage Test (A.C 2kV/1 min.)

- Allowable Current(30A/Core, 45 Minute)

Shift Bending(U-Bend) Test Condition

NormalNormalVoltage Test

Sheath AbrasionNormal

External

Appearance

Sheath MeltedNo change

Allowable

Current

No ChangeNo changeConductor

Resistance

Competing Company

(A)LS Cable

Evaluation

Items

Page 22: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

10. LS FA/Robot Cable, Supply History(Application Record)

Samsung Electronics

• Semi Conductor / LCD, Automated Production Line / - Cleanroom Cable for Power Chain- Supplied Cables : ROFHU-SB( For power supply), ROFHV-SB (For Encoder)

• PDP Automated Production line - Cleanroom Cable for power chain

- Supplied Cables : ROIREU-SB Type (Power, Encoder)

Hyundai Heavy Industries

• Industrial Robot system

- Fix & Motion Cable for driving Robot

- Supplied Cables : COVV-SB, COEV-SB, ROIREV-SB, ROFHV-SB,ROFHU-SB,

CO-FH, etc.

Samsung Techwin

• High Speed Chip mounter

- Power & Signal Cable

- Supplied Cables : ROVV-SB(Fix), X,Y Axis Cable Bear ROFHV-SB

20C Round Type Flat Cable (ROFHV(F)-SB 20C)

Ssangyong Motor• Welding Robot Application Cable

-Supplied Cables: ROFR 2CX22SQ+1CX16SQ(Power supply),

ROFHVU 25CX0.5SQ(Encoder)

Page 23: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

11. Bus Cable

DeviceNet Cable

Product Construction

Sheath

Braid Shield

Data Cable

Color : White

AL/MYLAR

Shield

Data Cable

Color : Blue

DC Power supply

Cable

Color : Black

AL/MYLAR

Shield

Ground Cable

DC Power Supply

Cable

Color : Red

• Application

• DeviceNet cable for Low cost communication Link

• Power supply and Signal transmission for control equipments

• Characteristics

• Power Supply(2 Lines) & Signal(2 Lines) & Ground Cable (1 Line)

• Linear Bus (Trunk line – Drop line)

• Multi Cored Cable:(24Vdc)Power+Signal+Common

:Easy & Simple wiring Minimize wiring error Cost Save

• Decrease Signal loss by using Foamed PE to Data Cable

Data RateData RateData RateData Rate ThickThickThickThick(Kbaud)(Kbaud)(Kbaud)(Kbaud) Max. Cumulative125 500M 100M 156M250 250M 100M 78M20 100M 100M 39M6MThinThinThinThinMax. TrunkLength Max. TrunkLength Drop Length• Transmission Distance

• Cable Standard

Item Size

Out

Diameter

(mm)

Impedence

(Ω)

Insulateion Resistance

(MΩ,km)

Conductor Resistance

(Ω/km)

Thin

(DBEV-IAMESB)

1PX22AWG

+1PX24AWG≒ 6.8

Min. 10000(24AWG)

Min. 100(22AWG)

Max. 91.8(24AWG)

Max. 57.4(22AWG)

Thick

(DBEV-IAMESB)

1PX15AWG

+1PX18AWG≒ 11.5

Min. 10000(18AWG)

Min. 100(15AWG)

Max. 22.6(18AWG)

Max. 11.8(15AWG)

Thick

(DBEV-IAMESB)

1PX14AWG

+1PX18AWG≒ 12.0

Min. 10000(18AWG)

Min. 100(14AWG)

Max. 22.6(18AWG)

Max. 11.8(14AWG)

120±10%

Page 24: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

CC – Link Cable (Ver. 1.10)

Cable Construction

Braid Shield

AL / MYLAR

Shield

Grounding Conductor

• Application

• CC-Link Cable for High speed Transmission & Big volume of data

• Characteristics

• High Speed Response , Easy and simple wiring work

by joining connector

• Multi function in one cable (Signal Transmission+ Power Supply)

• Improved shield characteristics by double shield

• Characteristics of the Cable

• Cable Standard

Conductor

Insulation

Sheath

Item Property Value

Conductor Resistance Max. 37.8 Ω/km

Insulation Resistance Min. 10000M Ω.km

Characteristic Impedence 110±15ΩElectric Capacity Max. 60pF/m

Max. 1.6dB/100m@1MHz

Max. 3.5dB/100m@5MHzAttenuation

Application Item Size ColorOut diameter

(mm)

Fixed PartPLFEV

-AMESB3Cx20AWG Brown ≒ 7.7

Moving PartROPLEV

-ESB3Cx20AWG Brown ≒ 8.0

11. Bus Cable

Page 25: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

Germany IPA Certification

12. Certifications of LS FA/Robot Cables

1. Use : Product certification for Clean room

2. Fields of application : Medical Treatment , Bio , Semi-conductor,

LCD production line, Foil, Optics,

Micro, Industrial Ceramic Techniques, etc.

3. Certification Organization : German IPA

(Institute Produktionstechnik und Automatisierung)

4. Certification Level : Clean Class 3 in conformity to ISO 14644-1

(ISO 14644-1 is a global standard of the requisites

and test item about Clean room)

5. Products : 1) XLPE, Teflon Insulated & Polyurethane Sheathed

2) XLPE, Teflon Insulated & Special PVC Sheathed

6. Significance : Applicable to the cables for Moving part of clean room

Test tool

Page 26: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

12. Certifications of LS FA/Robot Cables

1. Authorized Objects : LS Cable R & D Center

2. Organizations which endowed authority to LS Cable

1) UL (Underwriters Laboratories Inc.)

2) MOCIE, Republic of Korea

Ministry of Commerce, Industry and Energy

3) KATA

Korea Agency for Technology and Standard

4) KOLAS : Korea Laboratory Accreditation Scheme

3. Approval Subject : RoHS, 6 hazardous Materials)

( Pb, Cd, Cr6+, Hg, PBBs, PBDEs )

4. Significance : Publication of the international

certified UL test report for RoHS

LS Cable is a authorized and certified International Environment Test Approval organization

Page 27: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

12. Certifications of LS FA/Robot Cables (Global approval)

North America

Europe

Page 28: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

12. Certifications of LS FA/Robot Cables (Global approval)

Page 29: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

13. Cable Comparison Table (Other Cable Companies vs. LS Cable)Cable NameCable NameCable NameCable Name InsulationInsulationInsulationInsulation SheathSheathSheathSheath RemarkRemarkRemarkRemark Cable NameCable NameCable NameCable Name InsulationInsulationInsulationInsulation SheathSheathSheathSheath RemarkRemarkRemarkRemarkOLFLEX CLASSIC 100 special PVC special PVC Out-Door COVV PVC PVCOLFLEX CLASSIC 100 CY special PVC special PVC Braid Shield COVV-SB PVC PVCOLFLEX CLASSIC 100 SY special PVC special PVC Steel-Wire BraidOLFLEX SF special PVC special PVC Very thin(0.07mm) COVV PVC PVCOLFLEX 140 / 140 CY special PVC special PVC Harmonized VCT(SB) PVC PVCOLFLEX 150 / 150 CY special PVC special PVC UL/CSAOLFLEX 190 / 190 CY special PVC special PVC UL/CSA/CEOLFLEX 100 H HF Polymer HF Polymer Power HalogenFreeOLFLEX 110, 110 CY special PVC special PVC Out-Door/SB COVV(-SB) PVC PVC UL/CSAOLFLEX 110 CH HF Polymer HF Polymer SBOLFLEX 115 H HF Polymer HF Polymer ECOOLFLEX CLASSIC 400 P / CPspecial PVC PU ROV(V)U-(SB) PVC PU(PVC) PVC bedding OLFLEX 440 P / 440 CP TPE PU ROTPEU TPE-E PUOLFLEX 450 P special PVC PU Chemical-ResistanceROVVU PVC PU PVC beddingOLFLEX 500 P PU PUOLFLEX 540 P TPE PU ROTPEU TPE-E PUOLFLEX 540 CP TPE PU SB ROTPEU-SB TPE-E PU SBOLFLEX 550 P Rubber PU RORU Rubber PUH05RR-F / H05RN-F / H07RN-FRubber RubberOLFLEX SERVO 700 / 700 CYPVC PVC ROVV-ISW/CSB PVC PVC I/COLFLEX SERVO 710 CY TPE PVC SB ROTPEV-SB TPE-E PVC SBOLFLEX SERVO 720 CY PVC PVC SB ROVV-SB PVC PVC SBOLFLEX SERVO 730 / 730 CYPVC PVC 600V~1,000V ROVV PVC PVCOLFLEX SERVO FD 750 P PVC,TPE PU ROIREU XLPE PUOLFLEX SERVO FD 755 P TPE,PP PU ROTPEU TPE-E PUOLFLEX SERVO FD 755 CP TPE,PP PU SB ROTPEU-SB TPE-E PU SBOLFLEX SERVO FD 760 CP TPE PU SB ROTPEU-SB TPE-E PU SBOLFLEX SERVO FD 770 CP PVC PU SB ROTPEU-SB TPE-E PU SBOLFLEX SERVO FD 780 P / 780 CPPVC PU ROIREU(-SB) XLPE PU (SB)OLFLEX SERVO FD 785 P / 785 CPTPE PU ROTPEU(-SB) TPE-E PU (SB)OLFLEX SERVO FD 790 CP PVC PU SB ROIREU-SB XLPE PU SBOLFLEX FD CLASSIC 810 / 810 CYPVCPVCPVCPVC PVCPVCPVCPVC ROIREV(-SB)ROIREV(-SB)ROIREV(-SB)ROIREV(-SB) XLPEXLPEXLPEXLPE PVCPVCPVCPVC (SB)(SB)(SB)(SB)OLFLEX FD CLASSIC 810 P /810 CPPVCPVCPVCPVC PUPUPUPU ROIREU(-SB)ROIREU(-SB)ROIREU(-SB)ROIREU(-SB) XLPEXLPEXLPEXLPE PUPUPUPU (SB)(SB)(SB)(SB)OLFLEX FD 855 P / 855 CPTPETPETPETPE PUPUPUPU ROTPEU(-SB)ROTPEU(-SB)ROTPEU(-SB)ROTPEU(-SB) TPE-ETPE-ETPE-ETPE-E PUPUPUPU (SB)(SB)(SB)(SB)OLFLEX FD 90 PVC PVC UL/CSA ROVV PVC PVC UL/CSAOLFLEX FD 891 / 891 CY PVC PVC UL/CSA ROVV(-SB) PVC PVC UL/CSAOLFLEX FD 890 P / CP PVC PU ROVU(-SB) PVC PUROBOT 2000ROBOT 2000ROBOT 2000ROBOT 2000 TPE-ETPE-ETPE-ETPE-E TPE-ETPE-ETPE-ETPE-E SBSBSBSB ROFHV-SBROFHV-SBROFHV-SBROFHV-SB ETFEETFEETFEETFE PVCPVCPVCPVC SBSBSBSBOLFLEX ROBOT 900 / 900 DPOLFLEX ROBOT 900 / 900 DPOLFLEX ROBOT 900 / 900 DPOLFLEX ROBOT 900 / 900 DPTPE-ETPE-ETPE-ETPE-E PUPUPUPU ROBOTROBOTROBOTROBOT ROFHVU(-SB)ROFHVU(-SB)ROFHVU(-SB)ROFHVU(-SB) ETFEETFEETFEETFE PUPUPUPU PVC inner JacketPVC inner JacketPVC inner JacketPVC inner Jacket

LAPP CABLELAPP CABLELAPP CABLELAPP CABLE LS CABLELS CABLELS CABLELS CABLE

FlexibleCable

ItemItemItemItem

Page 30: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

Cable NameCable NameCable NameCable Name InsulationInsulationInsulationInsulation SheathSheathSheathSheath RemarkRemarkRemarkRemark Cable NameCable NameCable NameCable Name InsulationInsulationInsulationInsulation SheathSheathSheathSheath RemarkRemarkRemarkRemarkUNITRONIC LiYY PVC PVC COVV,ROVV PVC PVCUNITRONIC LiYCY PVC PVC SB CO(RO)VV-SB PVC PVC SBUNITRONIC LiYY (TP) PVC PVC Twisted CO(RO)VV-SB PVC PVC SBUNITRONIC LiYCY (TP) PVC PVC SB+Twisted CO(RO)VV-SB PVC PVC SBUNITRONIC LiYY UL/CSA PVC PVC COVV,ROVV PVC PVC UL/CSAUNITRONIC LiYCY UL/CSA PVC PVC SB CO(RO)VV-SB PVC PVC UL/CSAUNITRONIC LiYCY TP UL/CSA PVC PVC Twisted CO(RO)VV-SB PVC PVC UL/CSAUNITRONIC 100 PVC PVC COVV,ROVV PVC PVCUNITRONIC 100 CY PVC PVC SB CO(RO)VV-SB PVC PVC SBUNITRONIC LiYCY - CY PVC PVC Double Shield CO(RO)VV-ISB/CSB PVC PVC I/CUNITRONIC LiFYCY (TP) PVC PVC SB+Twisted CO(RO)VV-SB PVC PVC SBUNITRONIC CY PiDY (TP) PVC PVC Shielded PairUNITRONIC LiYD11Y PVC PU ROVU PVC PUUNITRONIC ST PE PVC ROIREV XLPE PVCUNITRONIC FD PVC PVC ROVV PVC PVCUNITRONIC FD CY PVC PVC SB ROVV-SB PVC PVC SBUNITRONIC FD P PVC PU ROVU PVC PUUNITRONIC FD CP PVC PU SB ROVU-SB PVC PU SBUNITRONIC FD CP (TP) PVC PU SB+Twisted ROVU-SB PVC PU SBUNITRONIC FD CP (TP) PLUS PO PU SB+Twisted ROIREU-SB XLPE PU SBUNITRONIC Li2YCY (TP) PE PVC SB+Twisted ROIREU-SB XLPE PU SBUNITRONIC Li2YCYv (TP) PE PVC for undergroundROIREV-SB XLPE PVC SBUNITRONIC Li2YCY PiMF PE PVC AMESB ROIREV-AMESB XLPE PVC AL/SBUNITRONIC JE-Y(ST)Y PVC PVC Solid Copper UL2095-AMS PVC PVC AL ShieldUNITRONIC JE-LiYCY PVC PVC Solid Copper UL2464-SB PVC PVC SB

DataCable

ItemItemItemItem LAPP CABLELAPP CABLELAPP CABLELAPP CABLE LS CABLELS CABLELS CABLELS CABLE13. Cable Comparison Table (Other Cable Companies vs. LS Cable)

Page 31: LS FA Cable - CCI Limited Certified Cable Imports FA Robotic Cable.pdf · Contents 1. Definition & Requisitions of FA/Robot Cables 2. FA Cables Characteristics per each applicable

Thank You !Thank You !Thank You !Thank You !Thank You !Thank You !Thank You !Thank You !