LINEAR SYSTEMS, a technocrat rm based in Mumbai (India)is a well established and reputed manufacturer of Burner Controllers for Boilers and Furnaces. Controllers are manufactured deploying state-of-the-art technology.
Founded in 1986, the rm has relentlessly worked forinnovation for the Flame Monitoring in the processindustry. At Linear Systems, we believe in
LED Indication of Sequence Progress
Attractive and Compact Enclosures
Local and Remote Reset Facility
Two Years of Warranty
Work as a team with customers and suppliers
Demonstrate our respect, integrity and honesty in whatwe do
Maintain a clean and healthy working environment
Growth coupled with customer’s satisfaction
Quality Products Timely Delivery
Cutomer SatisfactionAfter Sales Service
Features of Our Products
Our Vision
LS LINEARSYSTEMSFounded in 1986
BURNER / SEQUENCE CONTROLLERS( For Big Size Burners )
Gas Fired Burners / Furnaces with UV Flame Sensing
307-GL-S Gas Controller, with Inbuilt UV Amplifer.
307-GID-P (inbuilt Amplier) & 307-GE-P (with ExternalAmplier)
307-GE-S Gas Controller, with External UV Amplierwith Piolet Flame, Damper, Blower and Ignition Terminals.
Without Piolet Flame Proving :
Oil Fired Burners/ Boilers:
107-S-60, 107-S-30 (Standard modelswith pre purge time of 60 seconds and 30seconds)
107-S-FO (Controller for Furnace Oil)
107-M ( Suitable for Nestler Boilers)
107-TU
LS-107 (Suitable for IAEC Make Boilers)
150-P-6 (Equivalent to MA-150 Controller)
100 / 200 / 300Series Controllers
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
UV SENSOR AND AMPLIFIERS
UV Sensor 1
UV Sensor for Oil/Gas Flames
UV Sensor 2
UV Amplier
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
LINEAR SYSTEM's Flame rod sensor senses the ame using ame detection rectication technique. The Amplier providesa voltage for the Flame Electrode. The ame electrode is immersed in ame to sensed. The current thus generated bythe ow of electrons through the ame to the ground is detected by the controller for presence of ame. The sensor senses only the burning ame and completely insensitive tovisible light and refractory glows. It is best suited for sensing ame in Gas red burners.
UV / FR / PR(Flame Amplier)
FLAME ROD AMPLIFIERS
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
BURNER CONTROLLERS(For small and medium sized industries)
Models for Oil Fired Burners Controllers:
For Gas Fired Burners Controllers:
710 - PR - MA (equivalent to MA-81O Controllers)sensing by LDR.
712 - PR - 24 - PI4 (equivalent to LOA - 21 & LOA- 24 Controllers)
722 - FR - P5, where the ame sensing is done byusing Flame Rod.
732 - UV - P5, where ame sensing is by UV Sensor.
The controllers are housed in an ABS plastic enclosure withoverall size of 70mm(L)x110mm(B)x105mm(H). The enclosure consists of a base and Plug in Controller module, which facilitates easy replacement at sites.
700 Series Controllers
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
FLAME SENSORS FLAME SENSORS
FLAME SENSOR
FLAME SENSORS:
Flame Sensor uses a Light Dependent Resistor (LDR) for sensingame. The ame sensor essentially senses the "Light" emitted by lame. It is usually suited only for oil burners in Boilers. It is notsuitable for Furnaces, where background fefractory brich glows.These sensor senses all types of light, including Sun light and raysemitted by electric bulb ltube light.
Models :-
Flame Sensor (FS - 1) with Front ViewingFlame Sensor (FS - 2) with Side ViewingFlame Sensor (FS - 3) Equivalent to Satronic Sensors
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
FLAME AMPLIFIER:
FLAME EYE (FE-01) is a ame detector, which is sensitive to visiblelight. This used CDS (cadmium Sulphate) photo resistor as lightsensing device. This is suitable for sensing ame in oil red burners.Amplier has two potential free relay contacts rated at 230V AC,5 Amps.
UV / FR / PR(Flame Amplier)
FLAME AMPLIFIER
LS LINEARSYSTEMSFounded in 1986
ý www.linearsystemsindia.com
LS LINEARSYSTEMSFounded in 1986
Technical Data-IgnitionSystem MKZ 100-(PartNo. 0 096 600 017)
Operating Voltage : 230V(-15 %+10%) 50/60 Hz
Primary Current : 0.22 AOutput : 50 VA
IGNITIONTRANSFORMER
IGNITION TRANSFORMER
Connections
Primary
Secondary
Ignition voltage
Ignition Frequency
Ignition Spark Energy
Duty Cycle
Sparking distance
Fitting Position
Weight
Operating Temprature
2x at plug 2.8mm
2x4mm drops-in pins
2x7.5kV
25/30hz
approx. 500mJ
100%
1.5-3mm
0-60Cas required
300g
:
:
:
:
:
:
:
:
:
:
ý www.linearsystemsindia.com
LS LINEARSYSTEMSFounded in 1986
Detect small Ionisation current. Economical FlameSensor for small Gas Burners. Available in 6.25mmDiameter and 3mm Diameter.
FLAME ROD FOR GAS FLAMES
Flame Rod3 mm Dia
Flame Rod6.25 mm Dia
ý www.linearsystemsindia.com
Ofce Address
LS LINEARSYSTEMSFounded in 1986
To View E-CataloguePlease Scan QR Code
307, Vikrant Industrial Estate,Govandi Post Ofce Road,Deonar, Mumbai - 400 088,Maharashtra, India.
9820707710
(022) 2551 2534
(022) 2557 6002
[email protected]@linearsystems.in
ý www.linearsystemsindia.com