Leading the way Call 0844 543 6200 visit Stelrad.com @stelrad facebook.com/stelradradiators 1 CPD BIM Safety Standard 72 models Heights: 500mm, 600mm & 800mm Lengths: 560mm to 1960mm Outputs: 196 to 2767 watts, 668 to 9442 Btu/hr Types: K1, P+ & K2 LST Range Standard Stelrad’s range of Low Surface Temperature radiators is the most comprehensive in the UK, with sizes and models to suit all applications. They all meet NHS Guidance for ‘safe hot water and surface temperature’ and are finished with anti- bacterial paint as standard, making them the No.1 choice for safety-critical environments. Installation is simple and all components are included in a single robust pack.
Transcript
  • Leading the wayCall 0844 543 6200 visit Stelrad.com

    @stelrad facebook.com/stelradradiators

    11

    CPD BIM

    Safety

    Standard 72 models

    Heights: 500mm, 600mm & 800mm

    Lengths: 560mm to 1960mm

    Outputs: 196 to 2767 watts, 668 to 9442 Btu/hr

    Types: K1, P+ & K2

    LST RangeStandard

    Stelrad’s range of Low Surface Temperatureradiators is the most comprehensive inthe UK, with sizes and models to suitall applications. They all meet NHSGuidance for ‘safe hot water and surfacetemperature’ and are finished with anti-bacterial paint as standard, makingthem the No.1 choice for safety-criticalenvironments. Installation is simpleand all components are included ina single robust pack.

  • 650

    500

    800

    K1

    Casing Height

    50 ΔtCasing

    Length mm Emitter

    Height mmEmitter

    Length mm

    P+ K2

    560760960

    11601360156017601960560760960

    11601360156017601960560760960

    11601360156017601960

    300300300300300300300300450450450450450450450450600600600600600600600600

    400600800

    10001200140016001800400600800

    10001200140016001800400600800

    10001200140016001800

    196293391489587685782880290435580725870

    101511601305365548730913

    1096127814611643

    6691000133416682003233726683003989

    148419792474296834633958445312451870249331153740436149855606

    284426568710852994

    11361278386580773966

    1159135215461739501751

    100212521502175320032254

    96914541938242329073392387643611317197926373296395546135275593317092562341942725125598168377691

    348522696870

    1044121813921566478717956

    11951434167319122151615922

    123015371844215224592767

    118717812375296835624156475053431631244632624077489357086524734120983146419752446295734383939441

    UIN UIN UINWatts Btu/hr

    Watts Btu/hr

    Watts Btu/hr

    Heat output

    Heat output

    Heat output

    145000145001145002145003145004145005145006145007145024145025145026145027145028145029145030145031145048145049145050145051145052145053145054145055

    145008145009145010145011145012145013145014145015145032145033145034145035145036145037145038145039145056145057145058145059145060145061145062145063

    1

    145016145017145018145019145020145021145022145023145040145041145042145043145044145045145046145047145064145065145066145067145068145069145070145071

    650

    500

    800

    K1

    Casing Height

    40 ΔtCasing

    Length mm Emitter

    Height mmEmitter

    Length mm

    P+ K2

    560760960

    11601360156017601960560760960

    11601360156017601960560760960

    11601360156017601960

    300300300300300300300300450450450450450450450450600600600600600600600600

    400600800

    10001200140016001800400600800

    10001200140016001800400600800

    10001200140016001800

    147219292366439512585658217325434542651759868976273410546683820956

    10931229

    500748998

    12481498174819962246740

    1110148018502220259029613331932

    1399186323302797326237294193

    212319425531637744850956289434578723867

    101111561301375562749936

    1123131114981686

    7251087145018122174253728993262985

    148019732465295834513946443812791917255731953833447451125753

    260390521651781911

    10411171358536715894

    1073125114301609460690920

    11501379161018392070

    88813321776222026643109355339971220183024403050366042704880549015702353313939234706549262767062

    UIN UIN UIN

    Watts Btu/hr

    Watts Btu/hr

    Watts Btu/hr

    Heat output

    Heat output

    Heat output

    145000145001145002145003145004145005145006145007145024145025145026145027145028145029145030145031145048145049145050145051145052145053145054145055

    145008145009145010145011145012145013145014145015145032145033145034145035145036145037145038145039145056145057145058145059145060145061145062145063

    1

    145016145017145018145019145020145021145022145023145040145041145042145043145044145045145046145047145064145065145066145067145068145069145070145071

    Stelrad LST Range Standard

    (75/65/20°C)

    (65/55/20°C)

    ∆t50 is the UK’s industry standard for heating outputs, which has an operating temperature of 75/65/20°C if you havea low temperature heat source you may wish to consider ∆t40 or ∆t30 output (see your installer or system designer).

  • 650

    500

    800

    K1

    Casing Height

    30 ΔtCasing

    Length mm Emitter

    Height mmEmitter

    Length mm

    P+ K2

    560760960

    11601360156017601960560760960

    11601360156017601960560760960

    11601360156017601960

    300300300300300300300300450450450450450450450450600600600600600600600600

    400600800

    10001200140016001800400600800

    10001200140016001800400600800

    10001200140016001800

    101151201252302353403453149224299373448523597672188282376470564658752846

    344515687859

    1031120413741546510764

    101912741529178420382293641963

    128316041926224625672887

    146219293366439512585658199299398497597696796896258387516645774903

    10321161

    499749998

    12481497174719962246678

    1019135816972037237627173056880

    1320176122002639308035203961

    179269358448538627717806246369492615739862985

    1108317475633792950

    110812661425

    611917

    122315291834214024462752840

    126016802100252029403360378010811620216127013240378143214862

    UIN UIN UINWatts Btu/hr Watts Btu/hr Watts Btu/hrHeat output Heat output Heat output

    145200145201145202145203145204145205145206145207145208145209145210145211145212145213145214145215145216145217145218145219145220145221145222145223

    145248145249145250145251145252145253145254145255145256145257145258145259145260145261145262145263145264145265145266145267145268145269145270145271

    145224145225145226145227145228145229145230145231145232145233145234145235145236145237145238145239145240145241145242145243145244145245145246145247

    Stelrad LST Range Standard

    EN 442 Certification Data - CETIAT tested in accordance with BS EN 442Type

    Casing Height 500 650 800 500 650 800 500 650 800

    Emitter Height 300 450 600 300 450 600 300 450 600

    W/m at 75/65/20 489 725 913 710 966 1252 870 1195 1537

    n-coefficients 1.19 1.25 1.34 1.24 1.27 1.31 1.27 1.30 1.32

    Heated Surface Area (m²/m) 2.09 3.37 4.66 2.44 3.84 5.24 3.51 5.62 7.74

    Weight (kg/m) 17.80 23.50 29.40 22.70 30.72 38.40 24.40 33.30 42.50

    Water Contents (l/m) 1.89 2.57 3.25 3.70 5.15 6.60 3.70 5.15 6.60

    K1 P+ K2

    (55/45/20°C)

  • LST Standard wall fixings & bracket positionsAll dimensions in mm. Inches in brackets.

    B

    A 195 (7.67)

    Casing Length

    Casi

    ng H

    eigh

    t

    195 (7.67)

    165 (6.49) 165 (6.49)

    195 (7.67)

    Casing Length

    195 (7.67)

    100

    (3.9

    3)

    102

    (4.0

    1)

    24

    (0.9

    4)

    134

    (5.2

    7)

    Cas

    ing

    Hei

    ght

    960 800760 650560 500

    CasingLength

    CasingHeight

    24

    (0.9

    4)

    100

    (3.9

    3)

    102

    (4.0

    1)

    134

    (5.2

    7)

    165 (6.49) 165 (6.49)

    A B

    800650500

    CasingHeight

    CasingLength

    13601560

    19601760

    1160545645

    845745

    445575675

    875775

    475

  • LST Standard connection optionsAll dimensions in mm. Inches in brackets.

    A

    25 (0.98)

    132 (5.19)

    119

    (4.68)

    Casi

    ng H

    eigh

    t

    800 550650 400500 250

    CasingHeight A

    LST Standard piping options

  • LST Standard front case view. LST Standard inside thecasing showing theemitter.

    LST Standard emitter,showing high level valveoption (valve not included).

    LST Standard circularknockout for TRV. Oblongknockout for pipe.

    LST Plus inside the casingshowing the emitter.

    LST Vertical front case view. LST i Plus front case view. LST i Plus inside the casingshowing the emitter.

    LST Plus front case view.

    LST Range Components


Recommended