1755 Telstar Drive, Suite 107Colorado Springs, Co 80920719.900.7220 Owww.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\H
amm
ers
Con
stru
ctio
nIn
c\C
O,E
lPas
oC
ount
y-H
CI0
0000
3.01
-Cra
cker
jack
\CAD
D\3
-CD
\DW
G\H
CI0
3_C
3.1-
Lite
.dw
g-R
yan
Gra
ham
-6/2
6/20
17
HCI003.1
JUNE 2017
Init.# Issue / DescriptionDate
CO
NS
TRU
CTI
ON
DO
CU
ME
NTS
CR
ACKE
RJA
CK
MU
DJA
CKI
NG
INC
.C
BP,F
2-L
OT
#21
SW
CO
RN
ERO
FM
cCLA
INPT
&C
OLE
VWC
OLO
RAD
OSP
RIN
GS,
CO
THESE PLANS ARE AN INSTRUMENT OFSERVICE AND ARE THE PROPERTY OFGALLOWAY, AND MAY NOT BE DUPLICATED,DISCLOSED, OR REPRODUCED WITHOUTTHE WRITTEN CONSENT OF GALLOWAY.COPYRIGHTS AND INFRINGEMENTS WILLBE ENFORCED AND PROSECUTED.
COPYRIGHT
NOT FOR
CONSTRUCTION
00 06/XX/17 AGENCY SUBMITTAL TAC
SCALE: 1"=10'
0 5 10
JMG
TAC
PHOTOMETRIC PLAN
C3.1
CAUTION - NOTICE TO CONTRACTOR1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS
PROVIDED BY THE APPROPRIATE UTILITY COMPANY ANDFIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TOBE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THECONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELDLOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHERSHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TOCONSTRUCTION.
2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFYTHE HORIZONTAL AND VERTICAL LOCATION OF SUCHEXISTING UTILITY, EITHER THROUGH POTHOLING ORALTERNATIVE METHOD. REPORT INFORMATION TO THEENGINEER PRIOR TO CONSTRUCTION.
LUMINAIRE SCHEDULESYMBOL QTY LABEL MOUNTING LLF CATALOG NUMBER WATTS LUMENS
6 2 WALL @ 15'-6" 1.0 WST LED P3 40K VF MVOLT DDBXD 50 6610
2 1 WALL @ 8'-0" 1.0 WST LED P1 40K VW MVOLT E20WC DDBXD 12 1659
DESCRIPTION
LITHONIA LIGHTING, WST LED ARCHITECTURAL WALL SCONCE, LUMEN PACKAGE P3, 4000K COLOR TEMPERATURE,
LITHONIA LIGHTING, WST LED ARCHITECTURAL WALL SCONCE, LUMEN PACKAGE P1, 4000K COLOR TEMPERATURE,VISUAL COMFORT WIDE THROW, EMERGENCY BATTERY BACKUP-COLD, BRONZE COLOR
2 VISUAL COMFORT FORWARD THROW, BRONZE COLOR
PHOTOMETRIC SITE PLAN1 SCALE: 1"=10'-0"
2
2
2 2 1 22
1
1755 Telstar Drive, Suite 107Colorado Springs, Co 80920719.900.7220 Owww.gallowayUS.com
2016. Galloway & Company, Inc. All Rights Reserved
Date:
Drawn By:
Project No:
Checked By:
H:\H
amm
ers
Con
stru
ctio
nIn
c\C
O,E
lPas
oC
ount
y-H
CI0
0000
3.01
-Cra
cker
jack
\CAD
D\3
-CD
\DW
G\H
CI0
3_C
3.2-
Lite
Det
s.dw
g-R
yan
Gra
ham
-6/2
6/20
17
HCI003.1
JUNE 2017
Init.# Issue / DescriptionDate
CO
NS
TRU
CTI
ON
DO
CU
ME
NTS
CR
ACKE
RJA
CK
MU
DJA
CKI
NG
INC
.C
BP,F
2-L
OT
#21
SW
CO
RN
ERO
FM
cCLA
INPT
&C
OLE
VWC
OLO
RAD
OSP
RIN
GS,
CO
THESE PLANS ARE AN INSTRUMENT OFSERVICE AND ARE THE PROPERTY OFGALLOWAY, AND MAY NOT BE DUPLICATED,DISCLOSED, OR REPRODUCED WITHOUTTHE WRITTEN CONSENT OF GALLOWAY.COPYRIGHTS AND INFRINGEMENTS WILLBE ENFORCED AND PROSECUTED.
COPYRIGHT
NOT FOR
CONSTRUCTION
00 06/XX/17 AGENCY SUBMITTAL TAC
JMG
TAC
PHOTOMETRIC DETAILS
C3.2
MANUFACTURER SPECIFICATION SHEET FOR WALL FIXTURES "1" & "2"
1
21
2
1