THT-EX Tel: +1-281-645-8426 │ Web: www.tht-ex-usa.com │ Email: [email protected]
Ø234.0 (9.21)
105.
0 ( 4
.13)
215.
8 ( 8
.50)
Luminaires For Use In Hazardous Locations
L1102
Design2020/08
Applications:•Power Plants•Heavy Industrials •Storage Facility•Paper Mills •Wastewater Treatment Plants•Loading Docks•Platforms•Shipyards •Chemical Processing Facility •Petrochemical Processing Facility
Standards:•UL 844•UL 1598 Luminaires•UL 8750•CSA C22.2 No 137-M1981•CSA C22.2 No. 250.0
Dimension:
Protection:•Class I, Division 1 Group B, C, D•Class II, Division 1 Group E, F, G•Class III•IP67 / NEMA 6
Net Weight: 5.5 kg (12.1 lb)
Field Installation:In mm (inches)
COB
SMD
Plastic Factory
Ambient Temperature:•CID1: -40°C ~ +40°C, T5•CIID1: +40°C, T5
THT-EX Tel: +1-281-645-8426 │ Web: www.tht-ex-usa.com │ Email: [email protected]
Polar LuminousIntensity Distribution
LuminousIntensity Distribution Diagram
AVERAGE BEAM ANGLE (50%) : 111.64 DEG
4785
3828
2871
1914
957
0.0
ANGLE (DEG)-180 -135 -90 -45 0 45 90 135 180
C0/180C90/270
C0/180C90/270
UNIT: cd
-90
-120 120
-150 150-/+180
90
-60 60
-300
30
0 0
Lumen (±10%)
L1102 Luminaires For Use In Hazardous Locations
Electrical:COB120V208V277V347V480V
60W0.50A0.29A0.22A0.17A0.13A
80W0.67A0.38A0.29A0.23A0.17A
100W0.83A0.48A0.36A0.29A0.21A
SMD120V277V
65W0.54A0.23A
75W0.63A0.27A
95W0.79A0.34A
Mechnical:Enclosure
Power FactorFrequency
cos≧0.9, cos≧0.87(480V)50 / 60 Hz
Aluminum AlloyGlass Tempered Glass
Cable Gland Stainless SteelCable 600V, 105°C
Entrance Thread 1 x NPT 3/4”
Optical:Color of LED Light 3000K (Warm White) / 5000K (Cool White)
CRI Warm White ≥ 80 / Cool White ≥ 70Beam Angle X-110° / Y-110°Lm / W (±10%) Warm White ≥ 95 / Cool White ≥ 100
60W5700lm6000lm
80W7600lm8000lm
COB3000K5000K
100W 9000lm
10000lm
95W8550lm9500lm
65W6175lm6500lm
75W7215lm7500lm
SMD3000K5000K
Optical Report:COB test
★Frosted Glass is available upon request.
THT-EX Tel: +1-281-645-8426 │ Web: www.tht-ex-usa.com │ Email: [email protected]
5.5 kg (12.1 lb)
6.3 kg (13.8 lb)
Pendant Mount
Wall Mount 25° (W25) View A90° (W90)
A
25° (H25) 90° (H90) View A
248.
0(9.
76)
366.0(14.41)
216.
0(8.
50)
234.0(9.21)356.0(14.02)
340.
0(13
.39)
231.0(9.09) 236.0(9.29)
296.
0(11
.65)
10.2
(0.4
0)
Ø35.0(1.38)
80.0(3.15)
140.0(5.51)
10.2
(0.4
0)
Ø35.0(1.38)
80.0(3.15)
140.0(5.51)
A
A
L1102 Luminaires For Use In Hazardous Locations
Mounting Option & Dimension : In mm (inches)
Model Code:
THT 2L A 100 Z 5 9 C 1102 W90① ② ③ ④ ⑤
① Category 2L=COB LED 2K=SMD LED
② Wattage 60W=60W, 80W=80W, 100=100W (for COB) 65W=65W, 75W=75W, 95W=95W (for SMD)
③ Voltage 6=120V, 7=208V, 2=220V 9=277V, F=347V, C=480V
④ C.C.T. C=Cool White W=Warm White
⑤ Mounting Bracket Type W25=Wall mounting 25° W90=Wall mounting 90° H25=Pendant mounting 25° H90=Pendant mounting 90°