L YNX Modulating Condensing Gas Boiler with optional Domestic Hot Water Generator Model No. LX-120CB 95% AFUE 3 models, 90, 120, 150 MBH max input suits most residential applications Input modulation from 25, 30, 37.5 MBH Advanced design, long life cast aluminum silicon alloy heat exchanger Natural or L.P. gas PVC/CPVC or stainless steel air intake and vent pipe -100 ft. equivalent length Digital electronic control w/outdoor reset Low NOx - friendly to the environment Ideal for radiant, baseboard, DHW or mixed applications Free-standing or wall hung All connections are on top Maintenance free brazed plate, DHW Stainless Steel heat exchanger Heat transfers from boiler to DHW with nearly 100% efficiency Provides hot water when you need it The next generation modulating, condensing gas boiler with optional Domestic Hot Water capabilities! Additional Lynx Combi Boiler Features Lynx Boiler Features 5 year parts & labor warranty included when registered upon installation! www.slantfin.com Free
Transcript
Page 1: LYN X Modulating Condensing Gas Boiler with …...LYN X Modulating Condensing Gas Boiler with optional Domestic Hot Water Generator Model No. LX-120CB • 95% AFUE • 3 models, 90,

LYNX Modulating Condensing Gas Boilerwith optional DomesticHot Water Generator

Model No. LX-120CB

• 95% AFUE• 3 models, 90, 120, 150 MBH max input suits most residential applications

• Input modulation from 25, 30, 37.5 MBH• Advanced design, long life cast aluminumsilicon alloy heat exchanger

• Natural or L.P. gas• PVC/CPVC or stainless steel air intake andvent pipe -100 ft. equivalent length

• Digital electronic control w/outdoor reset• Low NOx - friendly to the environment• Ideal for radiant, baseboard, DHW or mixedapplications

• Free-standing or wall hung• All connections are on top

• Maintenance free brazed plate, DHWStainless Steel heat exchanger

• Heat transfers from boiler to DHW withnearly 100% efficiency

• Provides hot water when you need it

The next generation modulating, condensing gas boilerwith optional Domestic Hot Water capabilities!

Additional Lynx Combi Boiler Features

Lynx Boiler Features

5 year parts & laborwarranty included when

registered upon installation!

www.slantfin.com

Free

Brian
PH Avail Phone
Page 2: LYN X Modulating Condensing Gas Boiler with …...LYN X Modulating Condensing Gas Boiler with optional Domestic Hot Water Generator Model No. LX-120CB • 95% AFUE • 3 models, 90,

Reliable next-generation technologyThe Lynx boiler utilizes an advanced aluminum silicon alloy lowmass heat exchanger design that makes it highly reliable andefficient. The patented heat exchanger has large waterwayswhich prevents plugging and virtually eliminates maintenance.

Modulation reduces cycling, maximizes fuel savings.The Lynx’s advanced operating controls automatically changesgas input up or down according to demand. The stainless steelcylindrical woven fiber burner supports the modulated flame forpeak performance. Ordinary boilers run inefficiently when theyrepeatedly cycle on and off. The Lynx will closely match theboiler’s output to just what is needed to meet demand for heat.It has longer run times and wasteful cycling is reduced. Lynx’scontroller also resets supply water temperature automaticallywhen connected to an outdoor sensor, further enhancingefficiency of the entire heating system.

Sealed combustion process offers peace of mind.The Lynx boiler operates in total isolation from household air.The combustion process is “sealed” inside the boiler, with intakeair and exhaust pipes connected directly to the outdoors. Thisreduces infiltration into the building that causes drafts.

Lynx electronic boiler control optimizesefficient operation.

Lynx’s advanced operating controls automaticallymodulate the boiler’s output by way of boiler watertemperature based on information it receives fromroom thermostats and outdoor sensor. It monitors thestatus of boiler components and controls the sequenceof operation. Options for domestic hot water control arebuilt in. An LED readout on the boiler’s control paneldisplays current conditions, set-up details anddiagnostic information.

Cast Aluminum Heat ExchangerCompact, powerful and agile. Slant/Fin’s new Lynxsealed combustion gas boiler purrs with performance.Operates at 95% AFUE maximizing fuel savings.Compact, light weight for easy handling. Advanceddesign cast aluminum heat exchanger sets a new stan-dard for reliability. You will be proud to offer the Lynx toyour customers looking for a high efficiency, advancedtechnology, long lasting boiler. This new generationdesign incorporates a cast aluminum heat exchangerthat is corrosion resistant with high thermal conductivity.

Front control panel, pipe, electrical connectionsand microprocessor control.

Model No. LX-120CB

Brian
PH Avail
Page 3: LYN X Modulating Condensing Gas Boiler with …...LYN X Modulating Condensing Gas Boiler with optional Domestic Hot Water Generator Model No. LX-120CB • 95% AFUE • 3 models, 90,

Model No. LX-120CB

Model No. LX-90

Optional Domestic Hot Water Generator (DHWG)Incorporating a brazed plate stainless steel heat exchanger,boiler water transfers heat to domestic water. This remarkableunit transfers heat to the domestic hot water with nearly 100percent efficiency. It requires no maintenance or cleaning andwill last for years and years. A circulator pump and flow switchare included. The pump is sized to overcome the friction lossesof the boiler and the heat exchanger and therefore providesenough boiler water flow to transfer the maximum amount ofheat energy from the boiler to the domestic hot water.

“DHW temp rise”The amount of hot water produced is largely dependent on theBTUH output of the boiler, the desired flow rate, the temperature ofthe hot water desired and the temperature of the incoming coldwater. In winter, water can be as cool as 40˚F. Therefore, if you want105˚F water (approximately the temperature one would like for ashower), a 65 degree temperature rise is required. With a LX-120-CB about 3.2 gpm would be available, for example. See the boxbelow for more information.

DHW Temp. Rise vs. Water Flow

Temp.Rise

rt-˚F

DHW Flow Rate - GPM

LX-120CB *Boiler

LX-150CB †Boiler

10080706055

2.02.53.03.54.0

2.33.34.04.55.0

The Lynx combi provides heat and Domestic Hot Water builtinto one neat compact cabinet. It includes brazed plate heatexchanger and circulator.

Blower, Gas Valve Assembly –Monoblock Heat Exchanger, Supply and Return Tube–

Exhaust Tube–

INSIDE THE JACKETS:

* Available now † Exp. spring 2011

Brian
PH Avail
Page 4: LYN X Modulating Condensing Gas Boiler with …...LYN X Modulating Condensing Gas Boiler with optional Domestic Hot Water Generator Model No. LX-120CB • 95% AFUE • 3 models, 90,

®

BOILERS & BASEBOARD

Since 1949

The Only Name You Want Heating Your Home.©2011 Slant/Fin Corp. Publication LX1-10A Printed in U.S.A. 1011

U.S.A.Slant/Fin Corporation • 100 Forest DriveGreenvale, NY 11548 • 516-484-2600www.slantfin.com

CanadaSlant/Fin LTD/LTEE • 6450 Northam DriveMississauga, Ontario L4V 1H9 • 905-677-8400www.slantfin.ca

Model AFUE InputMax Btuh

InputMin Btuh

D.O.E.HeatingCapacity

NetI=B=ROutput

ExhaustVent

AirIntake

WaterVolume

Supply &ReturnPiping

GasPipe Dimensions

DryBoilerWeight

LX-90 95% 90,000 25,000 80,000 70,0003" Schedule 40

PVC,CPVC or SS

3" Schedule40 PVC,

CPVC or SS

0.4Gal

1" NPT(Male)

1/2 NPT(Female)

35" H22" W16.25" D

118 lbs.

LX-120

LX-120CB95% 120,000 30,000 106,000 92,000

3" Schedule 40PVC,

CPVC or SS

3" Schedule40 PVC,

CPVC or SS

0.6Gal

1" NPT(Male)

1/2 NPT(Female)

35" H22" W16.25" D

125 lbs.

147 lbs.

LX-150LX-150CB

95% 150,000 37,500 133,000 116,0003" Schedule 40

PVC,CPVC or SS

3" Schedule40 PVC,

CPVC or SS

1.1Gal

1" NPT(Male)

1/2 NPT(Female)

35" H22" W19" D

140 lbs.

162 lbs.

BOILER "A" "B" "C" "D"MODEL

LX-90 6 3/4 3 3/8 2 3/4 16 1/4

LX-120 6 5/8 3 3/8 2 16 1/4

LX-150 6 3/8 3 3/4 2 3/4 19

33

35

22

LEFT SIDE FRONT RIGHT SIDE

5

"D"

"A"

"B""C"

LYNX Modulating Condensing Gas Boilerwith optional Domestic Hot Water Generator

Pre-assembled cast-aluminummono block heat exchanger

Pre-assembled jacketWoven metal fiber pre-mix burnerCombination blower, gas valve and venturiIntegrated boiler control with built-in diagnosticsDirect spark ignition system

Pressure gauge Outdoor SensorPressure relief valve (ASME)‡ Grundfos or Taco circulatorDrain cockBuilt-in condensate drain and trapVent and air intake terminal

Wall mounting kitOptional- 409999 Rhogard Anti-freezeFor propane, specify when ordering.

With Combi-BoilerBrazed Plate heat exchangerFlow SwitchBuilt in taco 0011 Circulator

Standard Equipment

Brian
PH Avail Phone

Recommended