+ All Categories
Home > Documents > M-Field Confidential © 2013

M-Field Confidential © 2013

Date post: 04-Feb-2022
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
33
CLEAN, SUSTAINABLE ENGERGY MFIELD Energy LTD. M-Field Confidential © 2013
Transcript

CLEAN, SUSTAINABLE  ENGERGY

M‐FIELD Energy LTD.

M-Field Confidential © 2013

2M-Field Confidential © 2013

About M‐FIELD

Fuel Cell Technology

M‐FIELD Product

Technology Development

Projects Completed

Conclusion

ABOUT M‐FIELD

M-Field Confidential © 2013

M‐FIELDM‐FIELD

TechnologyTechnology

Supporting ResourceSupporting Resource

MarketMarket

M‐FIELD Focus• Stationary Fuel Cell System Manufacture• International Project Coordination• Market Developing• Training & Service

Advantage:• 10 years of R&D Expertise• 27‐year Electricity experience• Over 10 years of cooperation with Ballard• Turn‐key solution provider• Close customer relationship• User friendly product design mentality• Adopt PEM Fuel Cell Technology

3

Milestone:2000 Fuel Cell R&D centre established. 

2002 M‐FIELD –Ballard cooperation began with Ballard Nexa fuel cell module 

2003 Announced 1kW fuel cell generator on Fuel Cell Today.Invited to join Taiwan Fuel Cell Partnership.

2005 Developing 5kW system with Government Advanced Research Project support.2006 Began 10kW fuel cell UPS R&D project with Government support.

2008 Accomplished 10kW fuel cell back‐up power development.Invited to attend Peru APEC Global CEO Summit as representative of Taiwan Clean Energy Industry

2009 Announced 10kW fuel cell UPS product & established  M‐FIELD.

2010 30KW Demonstrations awarded in Telecom and  International Flora Expo.2011 Developing 100kW Distributed Power Generator system.

2012 UEH Launched to the market.2013 UEH Field Test with customers Worldwide.

ABOUT M‐FIELD

4M-Field Confidential © 2013

5M-Field Confidential © 2012

About M‐FIELD

Fuel Cell Technology

M‐FIELD Product

Technology Development

Projects Completed

Conclusion

Fuel Cell Technology

Why Fuel Cell:

1. Clean & Environment Friendly

2. Energy Efficiency

3. Excellent Performance & Adaptability

4. Cost Effective

6M-Field Confidential © 2012

Fuel Cell Technology

Stack

Cell

7M-Field Confidential © 2012

Clean and Environment Friendly:

Theory : 2H2 + O2= H2O + e + HeatNo Green House Gas Emission

Only Byproduct is water

No Noise Pollution

Fuel Cell Technology

Higher Energy State

Energy

Source: The Business Case for Fuel Cells

Lower Energy State

HH

HHHH

HH

O

O

Reaction 4e-

HHHH

OHHHH

O

8M-Field Confidential © 2012

Energy Efficiency:Static Electrochemical Reaction• No Piston and Combustion: Less Energy Wasted• 1-Step Fuel-to-Power Conversion: 50% @ UTH Series

Fuel Cell Technology

Step 1 Combustion(Heat)

Step 2 Piston(Kinetic Energy)

Step 3 Spinning Coil(Magnetism)Fuel

Electricity

20~40% Eff.

Only 1 StepElectrochemical Reaction

Up to 50% Eff. Electricity

Fuel

9M-Field Confidential © 2012

Excellent Performance & Adaptability:

Fast Response and Better Environment Tolerance Wide Ambient Temperature(Operation) Tolerance: - 20oC~ 50oC Humidity Tolerance: 2%~ 100% RH non-condensing Wide Altitude Tolerance: -400m to 7600m No self-discharge after long-time storage

Fuel Cell Technology

Fuel Cell Performance vs. Temperature & HumidityFuel Cell Performance vs. Temperature & Humidity Batteries Performance vs. temperature and self‐dischargeBatteries Performance vs. temperature and self‐discharge

10M-Field Confidential © 2012

CitiGroup analysis report“ Our estimates show that fuel cells are 32% and 35% less expensive than battery backup

power solutions based on a ten- and 15-years useful life and a five-year battery replacement cycle, including energy tax credits. Without the credits, fuel cell life cycle costs are 12% and 18% less expensive on the same bases.”

UTH Series has over 1000 on-off cycles, best fit in backup solutions.

No Significant Natural decay as conventional batteries do.

11

Fuel Cell Technology

M-Field Confidential © 2012

Cost Effective 

12M-Field Confidential © 2013

About M‐FIELD

Fuel Cell Technology

M‐FIELD Product

Technology Development

Projects Completed

Conclusion

UTH Series1. Air management2. Efficient BOP system3. Turnkey system4. Easy installation 5. Simple maintenance 6. Auto‐start7. Fast on‐off cycles operation8. Complete monitoring system 

Item UTH‐0320 UTH‐0620

Power DC 3000W DC 6000W

Output Voltage Range 44~56 VDC Adjustable

Ambient Temperature  0~40oC (‐20oC for premium version)

System start‐up time 0 sec.

UPS Type On‐Line & Off‐Line (Optional)

Back‐up time* > 28 hours > 14 hours

Remote Monitoring Ethernet/ 3G/ Wifi

*Back‐up time based on 8 40L cylinders@ 200 barg and for full‐power output

M‐FIELD Product

13M-Field Confidential © 2013

Combination with Renewable Energy(as a Energy Storage )

Advantage:• Expandable power reservation• Reliable & stable power output• Regulate the power fluctuation• Cross‐season Mitigation capability• Less space required

M‐FIELD Product – UEH Series

14M-Field Confidential © 2013

M‐FIELD Product – UEH Series

15M-Field Confidential © 2013

Power SystemProduct series UEH-0110Rated Power DC 1kWOutput Voltage 48 VdcStart-up Time 0 sec Cooling Type Air-CoolingHydrogen Consumption <750 L / kwhRecharging Input Power 200V~240 AC, 50~60HzHydrogen Refilling time < 3 days Storage Capacity 8 KwhFeed-in electrolyzer Stock Distilled Water (DI water) Water Consumption 0.085 L/hPower Consumption 700WOperating EnvironmentAmbient Temperature 5~40°CEnvironment Humidity 0 ~90 % RHExtra FiguresRemote Moniter Ethernet/ 3G/ WifiInterface Language EnglishEnclosure Protection Outdoor IP 54 System Dimension L 100 x W 75 x H 126 cm

How Fuel Cell works with the Renewables

Load Requirement

Winter(Day)

Summer(Night)

Power (MW)

Wind (Solar) Power Fluctuation

Fuel Cell Base load

Power Stored 

M-Field Confidential © 2013

Load

H2 Storage

Fuel Cell Grid Power: Coal Power Plants, Hydro Power Plants, Nuclear

• Unlimited storage capacity: the more energy, the more H2 is stored.• Less space requirement: H2 can be compressed.

M‐FIELD Product

16

IndustrialAdvantage:

• Wasted by‐product reuse• Carbon neutral power generation• Lower the utility bill• Benefit from electricity resale• Utility expense regulation• Secured power supply• Carbon trading

Source: Herald Sun, Ballard Power systemTimeNormal Utility Price Peak Utility Price

Power(MW)

Load Required

GridGrid

Fuel Cell

Extra Power Resell to the grid with Higher feed‐in Tariff

M‐FIELD Product – 100KW ~  MW

17M-Field Confidential © 2013

18M-Field Confidential © 2013

About M‐FIELD

Fuel Cell Technology

M‐FIELD Product

Technology Development

Projects Completed

Conclusion

Air Management:All‐in‐one Function1. System Cooling2. Oxygen Supply3. Safety Protection – Dilute H2 concentration if leakage happensSimpler design but better performance and less chance of failure

FUEL CELL

Air Blower

Water Pump/ Fans

Vacuum Fan

Oxygen Loop

Oxygen LoopAir Exhaust

Coolant Loop

Hydrogen Ventilation Loop

Conventional Solution:Complex Piping system and Power consuming

MCU controlled Fan system

FUEL CELL

M‐FIELD

No Piping system required

M‐FIELD Technology

19M-Field Confidential © 2013

Turnkey Solution:1. Uninterruptible Power Supply (UPS)2. Rectifier and Power conditioning 3. Embedded Air‐cooling system4. Integrated Deep Cycle Batteries

FUEL CELL Product

External Cooling System

Rectifier

Batteries

44~80Vdc Fluctuating

Cooling connection

Hydrogen Supply

Conventional Solution: Complex integration and equipment matching

Charger

ConverterGrid Power

Grid Power

Grid Power

Load

48 Vdc

48 Vdc

220 Vac

220 Vac

220 Vac48 Vdc

DC Bus

Batteries System

FUEL CELLModules

Rectifier

Converter

Cooling System

Hydrogen Supply

Grid Power220 Vac

Wiring & Piping system

Load

M‐FIELDCompact Turnkey Solution

M‐FIELD Technology

20M-Field Confidential © 2013

Zoom in to click the site. You can access to the monitor by clicking the link below.

M‐FIELD Remote Control

21M-Field Confidential © 2013

M‐FIELD Remote Control

Features

Monitoring System

Real Time Fuel Storage Amount

Power Quality Monitoring

System Mode 

Alarm Index

Parameter & Data Collection 

Temperature Monitoring

Protection

Auto Protection Mechanism

System Failure Detection and Alarm

Allow 8 mins of Full‐Load Power time to act if system failure

Emergency Stop Function(On site and Remotely)

Reverse Power Protection

Remote Monitoring Screen:

22

UTH system(Site Area)

Graphical User Interface

(Remote Monitor)

control/monitorcontrol/monitor

Internet (TCP/IP)

GPRS

M-Field Confidential © 2013

Easy Installation:1. All‐in‐one piping and electrical connection panel2. Air cooling system: no cooling tower required3. Handle & Wheels designs for moving during installation4. Complete System Grounding 

Connection Panel:1. Fuel Inlet/Outlet (Hydrogen)2. AC Power Connection3. DC Power Connection4. Grounding Cable Connection 

Front & Rear sides handles

Air‐Cooling Design

M‐FIELD Product Advantage

23M-Field Confidential © 2013

Product Certification (CSA, UL & CE)

24M-Field Confidential © 2013

25M-Field Confidential © 2013

About M‐FIELD

Fuel Cell Technology

M‐FIELD Product

Technology Development

Projects Completed

Conclusion

Location     : Taiwan National Science & Technology MuseumApplication: Fuel Cell UPS Demonstration Period         : 2009 ~ Present

Projects 

26M-Field Confidential © 2013

Location     : 2010 Taipei International Flora Exposition

Application: 30kW Fuel Cell Generator

Period         : 2010.11/6  ~  2011.4/25 

http://www.2010taipeiexpo.tw

Projects

27M-Field Confidential © 2013

28

Installation     : Grid‐tied system

Running Hour : 08:00 – 22:00 everyday

Project Period: Nov. 6, 2010 ~ Apr. 25, 2011

H2 Provider    : Air Product

Projects

M-Field Confidential © 2013

0%

20%

40%

60%

80%

100%

010002000300040005000600070008000

106 211 401 593 803 971 1130 1294 1514 1749 1973 2211Daily output power Efficiency %

Location     : Telecom TowerApplication: Fuel Cell UPS Test & VerifyPeriod         : 2010~2012.

Over 2200 hours/ 200 On‐Offs

Projects 

Watt

Accumulative Hours

29M-Field Confidential © 2013

Location     : NRC, Canada

Application: 6kW Fuel Cell Generator 

Period         : 2012. 4 ~ present

Projects

M-Field Confidential © 201330

M-Field Confidential © 2013

Location      : Toronto, Canada

Application: 3kW Fuel Cell Backup Generator 

Period          : 2012. 5 ~ present

Projects Completed

31

Conclusion

M‐FIELD Service

Total Solution from beginning to the end:• Pre‐stage Analysis• Solution Integration• After Service

Pre‐Stage Analysis

1. Scenario Analysis2. Solution Consultancy3. Solution provision

Solution Integration

1. Fuel Cell Solution2. Hydrogen Solution3. Electrical Solution4. Installation

After Service

1. User Training2. Maintenance3. Upgrading4. Expansion

Customer Need

M‐FIELD

32M-Field Confidential © 2013

Thank You

M-Field Confidential © 2013


Recommended