Description
12 Series tied diaphragm regulator and 14 Series diaphragm valve mounted in a single body construction
Advantages
• Space saving - small footprint
• Reduced installation labor
• Improved start-up efficiency
• Fewer potential leak paths
• Lower overall cost
Miniature Gas Stickmaximum 125 or 150 PSIG in
Specifications
❏ Operating Parameters pressure rating per criteria of ANSI/ASME B31.3
maximum rated inlet pressure . . . . . . . . 125, 150 PSIG
design proof pressure. . 150% of maximum rated pressure
design burst pressure. . 400% of maximum rated pressure
leakage: inboard. . . . . . . . . . . . . . . <1 x 10-9 atm cc/sec He across valve seat . . . . . . <4 x 10-9 atm cc/sec He
operating temperature. . . . . . . . . . -40° F to +140° F (-40° C to +60° C)
flow capacity: standard . . . . . . . . . . . . . . . . Cv = .04 high flow . . . . . . . . . . . . . . . . Cv = .08
❏ Media Contact Materials body. . . . . 316L VAR SST with Precision Electropolish
diaphragm, regulator . . . . . . . . . . . . . . . . . Hastelloy®
diaphragm, valve. . . . . . . . . . . . . . . . . . . . . . Elgiloy®
seat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCTFE
valve stem . . . . . . . . . . . . . . . . . . . . . . . . . Hastelloy® For other materials or modifications, please consult Tescom.
❏ Internal Surface Finish . . . . . . . 10 Ra microinch (.25 micrometer)
❏ Connections. . . . . . . Welded female or male VCR®
❏ Internal Volume . . . . . . . . . . . . . . . . . . . . . . . 5 cc
❏ Weight. . . . . . . . . . . . . . . . . . . . . . . . . . 2 lbs. (.9 kg)
Elgiloy® is a registered trademark of Elgiloy Specialty Metals.Hastelloy® is a registered trademark of Haynes International, Inc.VCR® is a registered trademark of Swagelok Company.
D76
0200
X01
2
M4
M1
Pressure Conversion 14.2 PSIG = 1 kg/cm2 14.5 PSIG = 1 Bar
Micro-Stik M1 Miniature Gas Stick
All dimensions are reference & nominal Metric (millimeter) equivalents are in brackets
Part Number Selectorexample part number:
M1 - 1 0 RV [BLANK]
BASICSeRIeS VALVe LOCATION
MAX. P1
ReGuLATOR PReSSuRe
INLeT & OuTLeT PORTING OPTIONS 'A' ± .06" OPTIONS
M1 1 – Manual valve, inlet to regulator (see Fig. I)
2 – Manual valve, outlet of regulator (see Fig. II)
3 – Air operated (NC) valve, inlet to regulator (see Fig. I)
4 – Air operated (NC) valve, outlet of regulator (see Fig. II)
5 – LOTO valve, inlet to regulator (see Fig. I)
6 – LOTO valve, outlet of regulator (see Fig. II)
150 PSIG
150 PSIG
125 PSIG
125 PSIG
125 PSIG
125 PSIG
0 – 20" Hg Vac - 15 PSIG
1 – 3 - 30 PSIG
2 – 3 - 60 PSIG
3 – 3 - 100 PSIG
RM – 1/4" Male . . . . . . . . . . . . . . . . . . 3.70"
RT – 1/4" Female Swivel. . . . . . . . . . . 3.70"
Ru – IN Port:1/4" Male; OUT Port: 1/4" Female . . . . . . . . . 3.70"
RV – IN Port:1/4" Female Swivel; OUT Port: 1/4" Male . . . . . . . . . . 3.70"
[Blank] – Standard
- F – Filtered*- H – High Flow
*Filter media is nickel.Accessories & modifications may be available for this product. Please contact TESCoM for more information.
FIGURE I FIGURE II
All dimensions are reference & nominal Metric (millimeter) equivalents are in brackets
Part Number Selectorexample part number:
M4 - 1 3 RV [BLANK]
BASICSeRIeS VALVe LOCATION
MAX. P1
ReGuLATOR PReSSuRe
INLeT & OuTLeT PORTING OPTIONS 'A' ± .06" OPTIONS
M4 1 – Manual valve, inlet to regulator (see Fig. I)
2 – Manual valve, outlet of regulator (see Fig. II)
3 – Air operated (NC) valve, inlet to regulator (see Fig. I)
4 – Air operated (NC) valve, outlet of regulator (see Fig. II)
5 – LOTO valve, inlet to regulator (see Fig. I)
6 – LOTO valve, outlet of regulator (see Fig. II)
150 PSIG
150 PSIG
125 PSIG
125 PSIG
125 PSIG
125 PSIG
0 – 20" Hg Vac - 15 PSIG
1 – 3 - 30 PSIG
2 – 3 - 60 PSIG
3 – 3 - 100 PSIG
RM – 1/4" Male . . . . . . . . . . . . . . . . . . 6.00"
RT – 1/4" Female Swivel. . . . . . . . . . . 5.59"
Ru – IN Port:1/4" Male; OUT Port: 1/4" Female . . . . . . . . . 5.59"
RV – IN Port:1/4" Female Swivel; OUT Port: 1/4" Male . . . . . . . . . . 6.00"
Hu – IN Port:1/4" Male (hi flow); OUT Port: 1/4" Female (hi flow) . 6.00"
[Blank] – Standard
- F – Filtered*- H – High Flow
*Filter media is nickel.Accessories & modifications may be available for this product. Please contact TESCoM for more information.
Micro-Stik M4 Miniature Gas Stick
Flow Chart see reverse side
FIGURE I FIGURE II
©Tescom Corporation, 2007; All Rights Reserved.Tescom is a business unit of the Regulator Division. Trademarks are property of divisions of Emerson Process Management.
Form No. 1994 Rev. 9/07 Printed 9/07 3M Printed in the U.S.A.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such product at any time without notice.
Tescom High Purity controlsTel: 800-447-9650 • 763-241-3222Fax: 763-241-3209 • email: [email protected] 19111 Industrial Boulevard • Elk River, MN 55330 USA
www.Tescom.com
For information contact:
Micro-Stik Miniature Gas Stick
Flow Charts
OU
TL
ET
PR
ES
SU
RE
- P
SIG
FLOW RATE - SLPM (Nitrogen)
0
10
20
30
40
50
60
70
80
90
100
10 20 30 40 50 60 70 80 90 100 110 120
100 PSIG Inlet
80 PSIG Inlet
60 PSIG Inlet
M4M1 and M4 High Flow
OU
TL
ET
PR
ES
SU
RE
- P
SIG
FLOW RATE - SLPM (Nitrogen)
0
5
10
15
20
25
30
35
5 10 15 20 25 30
100 PSIG Inlet
60 PSIG Inlet
12 Series
60 PSIG Inlet
30 PSIG Inlet
WARNING! Do not attempt to select, install, use or maintain this product until you have read and fully understood the Tescom safety, Installation & operation Precautions.
M1 and M4 Standard