B.Hargreaves - RAD 229 Section A2 Magnetization Preparation Sequences • Acquisition method may not give desired contrast • “Prep” block adds contrast (and/or encoding) • MP-RAGE = Magnetization prepared rapid acquisition with gradient echo (Mugler, ~1990) • Inversion-recovery (IR) prep • Fat saturation •T 2 -prep • Diffusion-weighted imaging 1 Mag Prep Imaging Sequence Mag Prep ...
Transcript
Page 1: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Magnetization Preparation Sequences• Acquisition method may not give desired contrast

• “Prep” block adds contrast (and/or encoding) • MP-RAGE = Magnetization prepared rapid acquisition with

gradient echo (Mugler, ~1990) • Inversion-recovery (IR) prep • Fat saturation • T2-prep • Diffusion-weighted imaging

1

Mag Prep

Imaging Sequence

Mag Prep...

Page 2: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Contrast Review

• Spin Echo

• PD, T1, T2

• Echo-train effects

• Gradient Echo

• bSSFP, Gradient Spoiled (T2/T1)

• RF spoiled (T1)

• PD (how?) is inefficient, T2 is not possible

2

Page 3: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fast Recovery (FR) or Driven Equilibrium

RF

Gz

Gy

Gx

Signal

...

...

...

...

...

180º180º90º -90º

180º

Fast-Recovery

3

Page 4: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fat-Saturated FSE

RF

Gz

Gy

Gx

Signal

...

...

...

...

...

180º180º90º

Fat-Sat

4

Page 5: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fat Suppression for Contrast

5

PD FSE Fat-Sat PD FSE

Radial cyst was otherwise iso-intense with fatCoronal Wrist Coronal Wrist

Page 6: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fat Saturation

• Chemically-selective excitation

• Dephaser gradient

• Normal imaging sequence

6

Frequency

. . . Sequence

Fat Water

RF BandwidthTime

Excite Fat Only

Dephase Fat Signal

FatSuppression

WaterSuppression

Unsuppressed Fat Signal

Page 7: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Effect of Fat Saturation

Fat-Saturated (PD) Not Fat-Saturated (T1w)

7

Page 8: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Inversion-Recovery

180º 180º

RF

Sig

nal

1

-1

0

• Fat suppression based on T1

• Short TI Inversion Recovery (STIR)

TI

8

90º

Page 9: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fat Suppression near B0 Inhomogeneity

Fat Sat STIR9

Page 10: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Fluid Attenuated Inversion-Recovery

180º 180º

RF

Sig

nal

1

-1

0

• Fluid suppression based on T1

• FLAIR

TI

10

Page 11: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Long Inversion Time (TI) - FLAIR

Long TI suppresses fluid signal11

Page 12: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Mag-Prep: Inflow-enhanced MRA

Preparation: • Background Suppression • Fat Suppression

12

Courtesy Pauline Worters

Page 13: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

T2-Prep (Enhance T2 contrast)

RF

Gz

180º90º -90º

180º

Regular Imaging

Sequence

T2-prep + Fat-Sat Renal Artery13

Page 14: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

T2-Prep: Flow-Independent Angiography

No Prep T2-prep + IR prep14

• Inversion: Suppress synovial fluid • T2-prep: Arterial-venous contrast

Courtesy Neal Bangerter

Page 15: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Spatial Saturation• Reduced FOV imaging

• Saturate “bands” outside FOV to prevent aliasing

15

Product full FOV SSFSE SSFSE w/ Spatial Sat.

SSFSE SSFSE w/ Sp. Sat

Page 16: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Myocardial Tagging• Spatially selective saturation pattern (lines, grid)

• Often ‘cine’ acquisition

16

TrueFISP (bSSFP) FLASH (RF Spoiled)Courtesy J. Zwanenburg (MRM 2003)

McVeigh ER, MRI 1996

Zerhouni E, 1988

Page 17: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Diffusion-Weighted Imaging (DWI)

RF

Gz

180º

No Diffusion

17

Page 18: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Diffusion-Weighted Imaging (DWI)

RF

Gz

180º

Diffusing Spins

18

Page 19: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Diffusion-Weighted Imaging (DWI)

Low b-value High b-value ADC T2 FSE

19

Page 20: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Phase ContrastRF

Gz

x

Frequency

Position

Phase is not zero! (any position)

20

� = �(x

ZG

x

dt+ x

0Z

G

x

tdt)

“Zero Moment” “First Moment”

Page 21: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Flow Encoded Imaging

Krishna NayakMarcus Alley21

Page 22: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Magnetization Transfer (MT)• Saturate very-short-T2 water bound to macromolecules

• MT effect causes saturation of free water (signal loss)

• More RF generally causes more MT saturation (adverse)

• CEST: Saturation at specific frequency

22 Henkelman RM et al. NMR in Biomedicine 2001; 14(2):57-64.

Courtesy of Feliks Kogan

Page 23: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Other Preparations

• Double IR: Non-selective, then selective

• “Black Blood”

• Multiple IR: Null multiple species simultaneously

• Arterial spin labeling (Invert blood, subtract reference)

• Diffusion preparation (tip-up)

• Motion-sensitized driven equilibrium (MSDE)

• Null vessel signal

23

Page 24: Magnetization Preparation Sequences - Stanford University€¦ · Magnetization Preparation Sequences •Acquisition method may not give desired contrast •“Prep” block adds

B.Hargreaves - RAD 229Section A2

Summary of Magnetization Prep

• Suppression: Spatial, Fat, Blood, Fluid

• Contrast: Inversion, T2-prep, Diffusion

• Encoding: Flow/motion, Diffusion, Tagging

24


Recommended