+ All Categories
Home > Documents > Mailing address: P.O. Box 550457 Dallas, Texas. 75355 ...

Mailing address: P.O. Box 550457 Dallas, Texas. 75355 ...

Date post: 15-Nov-2021
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
19
Mailing address: P.O. Box 550457 Dallas, Texas. 75355 Shipping address: 11011 Regency Crest Drive Suite 200 Dallas, Texas. 75238 http://www.marlincontrols.com [email protected] (214) 553-1011 (214) 553-5700
Transcript

Mailing address:P.O. Box 550457

Dallas, Texas. 75355

Shipping address:11011 Regency Crest Drive

Suite 200Dallas, Texas. 75238

http://www.marlincontrols.com [email protected] (214) 553-1011(214) 553-5700

LIGHTING CONTROL SYSTEMCHECKLIST Date

Project Name:Project Location:

Installet:Contact Phone No:Elec. Contractor:Step 1:

Step 2:

Step 3:

Step 4:

PHYSICAL CONDITION

CONTROLLER INSTALLATION

LOW VOLTAGE WIRING

START UP

1.1 Verify all foreign materials have been removed from the dimmer cabinet,particulary wire scraps 1.2 Verify all mounting hardware is secure1.3 Verify all wiring is properly routed and termination are tight1.4 Verify all by-pass jumpers are connected

2.1 Verify the proper control box has been used with no internal flanges or mounting hardware that might come in contact with the controller or interfere with wirerouting

1 gang Raco #6954 gang Raco #6983 gang Raco #697

2 gang Raco #6965 gang Raco #699

3.1 Verify proper wire has been used, acceptable types (see Wiring Diagram Black for more detail) are: 2 PR # 20 AWG Belden 9402 (for digital applications) 3/C # 20 AWG Belden 9939 (typical for photocell) 6/C # 20 AWG Belden 9941 (typical for DCRelay-4) 10/C # 20 AWG Belden 9946 (typical for TPC/PCA)3.2 Verify shields are only connected to the ground lug in the dimmer 3.3 Verify shields are connected together where the cabling continues on to another device3.4 Verify all shields are taped off to prevent shorting to controllers or other devices3.5 Verify all unused wires are taped off

4.1 Turn on all circuit breakers, verify none trip4.2 Turn on slide switch on TB-3 (if multiple cabinets are installed, turn only 1 TB-3 on)4.3 Verify power supply is providing 12 volts DC4.4 Verify LCDs on controllers light up4.5 Turn off all circuit breakers4.6 Disconnect by-pass jumpers4.7 Turn circuit breakers back on4.8 Verify none trip and that lights can be controlled

2.2 Typical boxes are:

* Now you are ready to set and control your lights * For Technical Support, contact [email protected] Ph: 214-553-5700 Fax: 214-553-1011

Date00/00/00 Initial

Date00/00/00 Initial

Date00/00/00 Initial

Date00/00/00 Initial

Checklist Form REVA_2002

11011 Regency Crest Dr. Suite 200Dallas. Texas 75238

Fax 214-553-1011214-553-5700

READ FIRSTREAD FIRST

Due to the lack of standards and variation in LED technology including lamps and drivers, Marlin Controls will not be

responsible for any damaged, inoperable, or incompatible luminaires. The Architects, Electrical Engineer, Lighting designer, and the end user are responsible for the compatibility of the LED

lamp, driver, and dimmer.

WARNING

All systems and replacement ELV dimmer modules are shipped in forward phase mode unless it has been noted in the drawings

or requested for reverse phase.

11011 Regency Crest Dr. Suite 200Dallas. Texas 75238

Fax 214-553-1011214-553-5700

Leer PrimeroLeer Primero

Debido a la falta de estándar y la variación en la tecnología LED incluyendo lámparas y conductores, Marlin Controls no será

responsable en caso de cualquier daño. Tampoco sera responsable de luminarias inoperables o luminarias incompatibles. Los arquitectos,

Ingenieros eléctricos, diseñadores de iluminación, y los usuarios finales seran responsables de la compatibilidad de

la lámpara LED, el conductor del LED y el regulador de intensidad.

Todos los sistemas y reemplazos de módulos del regulador de intensidad ELV son envíados enfase directa a no ser que esten marcados en los dibujos o sean solicitados en la fase inversa.

ALTO

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17BLOCK DIAGRAM

= 2-PAIR TWISTED 20 AWG SHIELDED CABLE BELDEN #9402

1 2

3 4

5 6

7 8

OFF ON

RMS 8

1 2 3 4 5 6 7 8

Stellar

FADEPAGE

CHANNELS PRESETS

RMS 8

Southern Lighting Source Showroom: Duluth, GA.

3. RUN SEPARATE NEUTRAL PER CIRCUIT TO THE DIMMER CABINET.

5. BREAKERS - ONE 20 AMP PRIMARY BREAKER (RATED 10,000 AIC) PER DIMMER.

DIMMING SYSTEM CONTROL DETAIL GENERAL NOTES:

1. INFORMATION SHOWN ON THIS DETAIL IS DIAGRAMMATIC ONLY. VERIFY EXACT PARTNUMBER OF EACH COMPONENT AND ALL NECESSARY MATERIALS, AS REQUIRED FOR AN OPERABLE MARLIN CONTROLS DIMMING SYSTEM, WITH MANUFACTURER PRIOR TO BID, CONTACT [email protected] OR (214) 553-5700 FOR TECHNICAL SUPPORT.

2. 277 / 480 VAC, 3-PHASE, 4-WIRES, M.L.O.

4. LOW-VOLTAGE WIRING SHALL BE MINIMUM 2-PAIR TWISTED 20 AWG SHIELDED CABLE BELDEN #9402

6. MARLIN CONTROLS STANDARD DIMMER MODULE IS COMPATIBLE WITH INCANDESCENT, MLV AND ADVANCE MARK X FLUORESCENT DIMMING BALLAST ONLY

CONTROLLER

RMS 8

RMS 4

3

GANG

2

RACO #SWITCH BOX

697

696

SWITCH BOXES PROVIDED BY OTHERS

DMX Receptacle 1 695

DO NOT CONNECT INDUCTIVE LOADS SUCH AS MAGNETIC TRANSFORMERS AND MOTORS TO ELV DIMMERS.

YELLOW BYPASS CONNECTORS REPRESENT ELV DIMMERS. ELV DIMMERS ARE DESIGNED TO CONTROL INCANDESCENT, LED AND ELECTRONIC TRANSFORMERS ONLY.

INDUCTIVE LOADS WILL DAMAGE THE DIMMER AND VOID THE WARRANTY.

*

DMX-512RECEPTACLE

1 2

3 4

5 6

7 8

1 2 3 4

RMS 4Stellar

CHANNELS PRESETS

F SFADE

STELLAR RMS 4

COVER DIMENSION: 16"W X 64"H

CABINET DIMENSIONS : 14.5"W X 62"H X 5.5"D

DP2

(2) MLV,(8) 0-10V*DIMMERS

(1)Wire space EFD(1)Wire space MLV

* 0-10V DIMMERS REQUIRE (2) 18 AWG LOW VOLTAGE SHIELDEDWIRES, AND (2) 12 AWG WIRES..

1 2

3 4

5 6

7 8

1 2 3 4

RMS 4Stellar

CHANNELS PRESETS

F SFADE

STELLAR RMS 4

+1

2 S

+ S

- -12

SH

NC1

NO1

C1

NC3

NO3

C3

C2

NO2

NC2

C4

NO4

NC4

1 2

3 4

5 6

7 8

ON

AP

EM

s

+1 -1 +2 -2 +3 -3+4 -4 +5 -5 +6 -6 +7-7+8 -8

NO4

NC4

C4

NO4

NC4

C4

1 2

3 4

NOTE:ELECTRICALLY HELDLIGHTING CONTACTORSFURNISHED BY EC

TYPICAL4 POLELIGHTING CONTACTORS

NEUTRAL

HCRB-4

WARNING:Due to the lack of standards and variation in LED technology including

lamps and drivers, Marlin Controls will not be responsible for any damaged, inoperable, or incompatible luminaires. The Architects, Electrical Engineer,

Lighting designer, and the end user are responsible for the compatibility of the LED lamp, driver, and dimmer.

u u

All systems and replacement ELV dimmer modules are shipped in forward phase mode unless ithas been noted in the drawings or

requested for reverse phase.

RMSInstructions

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17RMS SYSTEM RISER DIAGRAM

1. TB-2 (Load Terminal Block)2. TB-1 (Line Terminal Block) - Main lug only; 277/480 VAC, 3 phase, 4 wires3. Neutral Assembly Block - Run separate neutral per circuit4. Ground - System must be grounded to the earth ground5. TB-3 (Low Voltage Control Terminal Block)

Dimmer Cabinet Notes:

FAN

OFF

ON

OFF ON

1 2 3 45 678

2

3

45

Must be run into a 3/4" conduit

FAN

OFF

ON

OFF ON

1 2 3 45 678

4 531

Neutral Assembly BlockLine Terminal Block

"TB-1"Ground Bar TB-3

Strip the wireto 1/2"

A B C

Strip the wireto 1/2"

TB-3 Pin Settings:

1 = +12VDC2 = S+3 = S-4 = -12VDC5 = +12VDC6 = S+7 = S -8 = -12VDC

Turn switches A and B to "ON" after installation

is complete

2

Load Terminal Block"TB-2"

Load fromDimmers

3/8"Slotted

ScrewdriverStrip the wire

to 1/2"

3/8" T-Hex Wrench

5/16" T-Hex Wrench

3/8"Slotted

Screwdriver

"TB-2"

"TB-1"

Neutral Assembly Block

Ground

"TB-3"

Strip the wireto 1/2"

1

+12V = To +12V+S = To +S-S = To -S- 12V = To - 12VShield = Tie shields together and cover with wire-nut at each control station.

RMS REAR VIEW

RCS / RMS REAR VIEW

SH

LD

-12V

S-

S+

+12V

C&KON TDA04

SH

LD

-12V

S-

S+

+12V

AB

Stellar Panel Dimming System

RMS 8

= 2-PAIR TWISTED 20 AWG SHIELDED CABLE BELDEN #9402

1 2

3 4

5 6

7 8

OFF ON

RMS 8

1 2 3 4 5 6 7 8

Stellar

FADEPAGE

CHANNELS PRESETS

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17TYPICAL LOW VOLTAGE RISER DIAGRAM

ATTENTION

u SHIELDED WIRES ARE ONLY CONNECTED TO THE GROUND LUG IN THE DIMMER CABINET.

u ALL SHIELDED WIRES ARE TAPED OFF TO PREVENT SHORTING TO THE CONTROLLERS OR OTHER DEVICES.

u ALL UNUSED WIRES ARE TAPED OFF OR TERMINATED.

u IMPROPER INSTALLATION WILL VOID LIMITED WARRANTY.

u u

SH

LD

-12VS-

S+

+12V

+1

2V

IN4

-12

V

IN3

-12

V

IN2

-12

V

IN1

RMS 8

Installation Notes:

1. Run a dedicated neutral for each circuit.

2. Ground Lug in Dimmer Cabinet must be hardwired to ground.

3. Connect low voltage cable shields at Ground Lug in Dimmer Cabinet only.

4. Mount the controllers 5 feet above finished floor.

5. All low voltage cabling to be 20 AWG shielded.

N L

POWERSUPPLY

CIRCUIT BREAKER

10 AMPEARTHGROUND

-V

+V

Connect all controllers with four-conductor,

low voltage shielded cable

(manufactured by Belden, #9402)

+12V = To +12V (Red)S+ = To S+ (White)S - = To S -(Green)-12V = To -12V (Black)

NEUTRAL

Shield = Tie shields together and cover with wire-nut at each control station.

*

SH

LD

-12VS-

S+

+12V

+1

2V

IN4

-12

V

IN3

-12

V

IN2

-12

V

IN1

RMS 4

GroundGROUND BARON THE PANEL

*

ON

-12V

DC

S -

S+

+12

VD

C

-12V

DC

S -

S+

+12

VD

C

NOT USENOT USEDMX + (D1+)DMX - (D1 -)COM (SHIELD)

STELLAR TB 3

+12 S+ S- -12 SH

*

HCRB-4 RELAY BOARD

DMX 512 COMMUNICATION

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR LAYOUT DIAGRAM

Dimmer Cabinet Notes:

TB-1 (Line Terminal Block) - Main lug only; 277/480 VAC, 3 phase, 4 wiresNeutral Assembly Block - Run separate neutral per circuitTB-2 (Load Terminal Block)TB-3 (Low Voltage Control Terminal Block)Breakers - One 20 amp primary circuit breaker (rated 10K AIC) per dimmerGround - System must be grounded to the earth ground

!WARNING!

DO NOT CONNECT INDUCTIVE LOADS SUCH AS MAGNETIC TRANSFORMERS

AND MOTORS TO MOSFET DIMMERS.

MOSFET DIMMERS ARE DESIGNED TO CONTROL INCANDESCENT, LED AND ELECTRONIC

TRANSFORMERS ONLY.

INDUCTIVE LOADS WILL DAMAGE THE DIMMER AND VOID THE WARRANTY.

Marlin Controls Standard Dimmer Moduleis compatible with Incandescent, MLV, and Advance Mark X Fluorescentdimming ballast only

#1, 2, 4-7, 10, 11 0-10 VDC (EFD) WHITE BYPASS CONNECTOR

STANDARD DIMMER (MLV) BLACK/RED BYPASS CONNECTOR

FA

N

OF

F

ON

OF

FO

N

1

2

3

45

6

78

1

2

3

4

5

6

7

8

9

10

11

12

EFD

EFD MLV

EFD

EFD

EFD

EFD

EFD

EFD

MLV

POWERSUPPLY

PRIMARY CIRCUIT BREAKERSRATED 10K AIC

POWER DISTRIBUTION

BLOCK, AC LINE(TB-1)

LOW VOLTAGECONTROL SIGNAL

TB-3G

RO

UN

D

MLV

EFD

#3, 9

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17WIRING DIAGRAM: 1 - 12

AB

CM

AIN

LU

G

TB

-1N

EU

TR

AL

AS

SE

MB

LY

BL

OC

K

20 A

MP

CB

5

20 A

MP

CB

6

20 A

MP

CB

LO

AD

20 A

MP

CB

7

8

ML

V D

IMM

ER

AB

LIN

E

LO

AD

ML

V D

IMM

ER

AB

LIN

E

20 A

MP

CB

9

20 A

MP

CB

20 A

MP

CB

1011

LIN

E

20 A

MP

CB

12

LIN

E

10 A

MP

CB

CP

OW

ER

SU

PP

LY

+12

V

-12

V

GR

OU

ND

NE

UT

RA

L

89

0-1

0 V

DC

DIM

ME

R

11

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

20 A

MP

CB

1

20 A

MP

CB

2

ML

V D

IMM

ER

AB

LIN

EL

OA

D

20 A

MP

CB

20 A

MP

CB

34

3

#1, 2, 4-7, 10, 11 0-10 VDC (EFD) WHITE BYPASS CONNECTOR

STANDARD DIMMER (MLV) BLACK/RED BYPASS CONNECTOR #3, 9

LIN

E

0-1

0 V

DC

DIM

ME

R

1

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

2

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

4

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

5

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

6

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

7

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

10

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

LIN

E

0-1

0 V

DC

DIM

ME

R

12

PU

RP

LE

GR

AY

+10 V

DC

-10 V

DC

LO

AD

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR LARGE CABINET DIMENSIONS

Enclosure dimensions Stellar 24: 14.5"W x 62"H x 4"DCover dimensions: 16"W x 64"H

Enclosure design allows for surface-mount or recessed installation between 2" x 4" studs, conserves space, and simplifies rough-in.

Top and bottom opening for feeding loads.

Type 1.14-gaige steel with white textured lead-free powder coated finish.

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17WIRE FEEDING OPTIONS

BOTTOM FEED

POWER

SUPPLY

DIMMER MODULES

PRIMARY

CIRCUIT BREAKERS

POWER

DISTRIBUTION

BLOCKS (TB-1) LOW VOLTAGE

CONTROL SIGNAL

(TB-3)

GROUND

TOP FEED

LOAD

TERMINAL

BLOCKS

(TB-2)

NEUTRAL

ASSEMBLY

LINE INPUT

TB-3

ONOFF

GROUND

TB-3

44

87

87 3

2

564

6 5

23

87

56

23

119

19

0 0

9

0

OFF ON

GROUND

2" CONDUIT

" - 1" CONDUIT34

" - 1" CONDUIT34

" - 1" CONDUIT34

" - 1" CONDUIT34

2" CONDUIT

2" CONDUIT

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17RMS 8: PARTS IN DETAIL

1 2

3 4

5 6

7 8

OFF ON

RMS 8

1 2 3 4 5 6 7 8

Stellar RMS 8 : Control Panel Layout (Front)

Stellar

CHANNELS PRESETS

FADEPAGE

INPUTS

1 2 3 4 5 6 7 8 9 10 G +12

k

Stellar RMS 8 : Control Panel Layout (Back)

a. Channel light level indicators Displays the current light level of each channel

a1. Channel adjust buttons. Raises and lowers the light level of each channel by 5% with each tap.

b. Preset/Off/On buttons Recalls presets and turns all lights off or on.

c. Page display window. Displays the currently selected page, or bank of eight channels.

c1. Page - Enables control of up to 64 dimmers over multiple pages.

d. Fade rate display window. Displays the fade rate of the active preset.

d1. Fade rate adjust button. Adjusts the speed at which light levels raise or dim (in seconds) when a preset is recalled.

e. Infrared receiver (IR) Receives signals from handheld remotes to adjust light levels and recall presets.

f. Activity LED Blinks in red when infrared signals are received; blinks in green when communication is taking place with the dimmer panel.

Rev11/14/2006

g. External inputs. Inputs for motion sensors and door switches.

h. Physical address. Identifies the RMS on the lighting system network.

i. Configuration dip switches. Each switch enables/disables the following advanced options:

j. RS-485 communication bus connector. Connects to the dimmer panel and other lighting controllers.

k. A/V, dry contact closure inputs. Automatically recall presets 1 through 10 (OFF and ON being presets 9 and 10, respectively) when a +12 VDC signal is received.

d1

f

e

b

g

SH

LD

-12VS-

S+

+12V

+12

V

IN4

-12V

IN3

-12V

IN2

-12V

IN1

SH

LD

-12V

S-

S+

+12V

ON

h

i

j

a

a1

c

c1d

ATTENTIONDownload the "QR-Barcode Scanner APP" for free in the

App Store/Google play to scan the QR codes.

u u

RMSInstructions

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR RMS 4: PARTS IN DETAIL

Stellar RMS 4 : Control Panel Layout (Front)

a. Channel light level indicators Displays the current light level of each channel

a1. Channel adjust buttons. Raises and lowers the light level of each channel by 5% with each tap.

b. Preset/Off/On buttons Recalls presets and turns all lights off or on.

d. Fade rate display window. Displays the fade rate of the active preset.

d1. Fade rate adjust button. Adjusts the speed at which light levels raise or dim (in seconds) when a preset is recalled.

e. Infrared receiver (IR) Receives signals from handheld remotes to adjust light levels and recall presets.

f. Activity LED Blinks in red when infrared signals are received; blinks in green when communication is taking place with the dimmer panel.

b

d e

fd1

1 2

3 4

5 6

7 8

OFF ON

1 2 3 4

a1

FADE

RMS 4Stellar

CHANNELS PRESETS

F S

a

INPUTS

1 2 3 4 5 6 7 8 9 10

SH

LD

-12VS-

S+

+12V

+1

2V

IN4

-12V

IN3

-12V

IN2

-12V

IN1

ON

k

Stellar RMS 4 : Control Panel Layout (Back)

V+V-

g. External inputs. Inputs for motion sensors and door switches.

h. Physical address. Identifies the RMS on the lighting system network.

i. Configuration dip switches. Each switch enables/disables the following advanced options:

j. RS-485 communication bus connector. Connects to the dimmer panel and other lighting controllers.

k. A/V, dry contact closure inputs. Automatically recall presets 1 through 10 (OFF and ON being presets 9 and 10, respectively) when a +12 VDC signal is received.

g

h

i

j

Rev2.0-9/2012

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR RMS : OPERATION GUIDE

Rev2.0-7/2012

Follow this procedure to manually adjust the brightness of each channel.

How to: adjust light levels

1. Press the PAGE button (where applicable) to select the page number.

The page window will display the selected page.

PAGE

Follow this procedure to recall a preset with a TV remote or the Malin Remote.

How to: recall a preset using a remote

1. Press the remote's channel buttons ("Presets" buttons on the Marlin Remote) to select a preset.

The active preset button will light up. 1 2 3

4 5 6

7 8 9

0

Presets (or scenes) let you quickly set all the channels in your system to predefined light levels. For example, you can create "evening," "lunch," or "clean up" presets, and recall them at any time using the procedure described below. To learn how to create presets, see "How to : program a preset."

How to: recall a preset

1. Press the desired preset number. The button will light up to indicate the active preset. The fade window will display the preset's fade rate (in seconds).

4

How to: program a preset

This procedure describes how to program the light levels for each channel and save them as presets, so they can be recalled again later. You may also program a fade rate, which controls how fast all channels raise or dim to their preset brightness.

1. Press and hold the preset number you wish to set.

The preset button will flash.

1 2

3 4

5 6

7 8

2. Press the PAGE button (where applicable) to select the page number.

The page window will display the selected page.PAGE

3 Press the channel adjust buttons to raise or lower light levels. *Press and hold OFF to cancel changes at any time.

4 Press the fade button to slow down or speed up the preset's fade rate.

The fade window will display the selected fade rate in seconds.

FADE

FAST SLOW

5 Press the preset number to store.

1 2

3 4

5 6

7 8

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17

5.50

RS- 485 portfor connecting to

Marlin's lighting networkusing four-conductor shielded cable

(manufactured by Belden, #9402).See page, "installation: Low Voltage

Wiring" for details.

Normally closed output

Circuit #1 - 120 VAC Input

Normally open output

Typical

Eight- position dip switchfor network address

HIGH CAPACITY RELAY BOARD 20 AMP (HC-RB-4) LAYOUT

5.00

HIGH CAPACITY RELAY BOARD

External Inputs(Dry contact or 12 VDCclosure input)

20 Amp Relay

+12 S

+ S

- -12 S

H

NC1

NO1

C1

NC3

NO3

C3

C2

NO2

NC2

C4

NO4

NC4

1 2

3 4

5 6

7 8

ON

AP

EM

s

+1 -1 +2 -2 +3 -3 +4 -4 +5 -5 +6 -6 +7-7 +8 -8

NO4

NC4

C4

NO4

NC4

C4

1 2

3 4

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17

COVER DIMENSION : 12'WX12"H ENCLOSURE DIMENSION :

12'WX12"HX4'D

HCRB & M-BUS INTERFACE ENCLOSURE

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR TB 3

(TB-3-SW4) Switch Number Value Description

None All Off No Action, Channel acts as a Dimmer(Factory Setting)

1 On Recall Preset 1

2 On Recall Preset 2

1 & 2 On Recall Preset 3

3 On Recall Preset 4

1 & 3 On Recall Preset 5

2 & 3 On Recall Preset 6

4 On Recall channels to FULL bright setting

-12V

DC

S -

S+

+12V

DC

-12V

DC

S -

S+

+12V

DC

OFF ONOFF

ON

+12VDC

-12VDC

SHIELD

POWER SUPPLY& RESET SWITCH

TO POWER SUPPLY

RIBBON CABLEHEADER

DIMMER CABINETADDRESS

TO CONTROLLER(S)

BLACKRED

WHITETO FAN

1 2 3 4

ON

DIP-SWITCH

TURN "CONTROLLER POWER SWITCH" LOCATED ON THE TB-3 TO "ON" AFTER INSTALLATION IS COMPLETE

OFF ON

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17STELLAR TB 3: DIP-SWITCH SETTINGS

1 2

3 4

ON

(A)

1 2

3 4

ON

(B)

1 2

3 4

ON

(C)1 2

3 4

ON

(D)

1 2

3 4

ON

(E)

1 2

3 4

ON

(F)

1 2

3 4

ON

(G)

1 2

3 4

ON

(H)

Preset #1 Preset #2 Preset #3 Preset #4

Preset #5 Preset #6 Factory Default Setting Full On

Dimmers controlled throughControl Station

OFF ONOFF

ON

1 2 3 4

ON

TB-3

A. (TB-3-SW4) No Action, Channels controlled through the master control station

B. (TB-3-SW4) Preset 1 is Recalled.

C. (TB-3-SW4) Preset 2 is Recalled.

D. (TB-3-SW4) Preset 3 is Recalled.

E. (TB-3-SW4) Preset 4 is Recalled.

F. (TB-3-SW4) Preset 5 is Recalled.

G. (TB-3-SW4) Preset 6 is Recalled.

H. (TB-3-SW4-#4) Channels go to Full On setting.( Factory Default Setting)

The dip-switch belonging to the TB-3 is located approximately in the middle of the TB-3 board.

This switch is also labeled SW4. For clarity, this dip-switch will be referred to as TB-3-SW4.

This dip-switch is used to recall the presets on all of the channels using switches 1,2, and 3.

The fourth switch in the "On" position, is used for forcing the channels to go to the FULL bright setting.

In the event of a short in the system, this setting will bypass the dimmers, protecting them from damage.

Using the combination of On/Off positions for switches 1, 2, and 3, presets 1 through 6 can be recalled.

These combinations are listed in the table below.

11011 Regency Crest Dr. Suite 200

Dallas, Texas 75238

214-553-5700

Fax 214-553-1011

STELLAR DIMMING CABINET . RMS 8 . RMS 4 . DMX-512

03/21/17HOW TO REPLACE DIMMER MODULE DETAIL

Step 1. Turn off the circuit breaker for the defective dimmer module. For example, If module #6 is not responding, then turn off circuit breaker #6.

ON

OF

F

Step 2. Unplug the flat ribbon cable from the dimmer module by lifting it straight up.

Step 3**. Disconnect the 3 position terminal strip by pulling it upward.

Note: 1. Do not remove the wires from the terminal block.

CAUTION

!

LOAD

LINE

NEUTRAL

Note 3: On DUAL, and EFD dimming modules, each has a 4-pin connector.

Single 20 AMP Dimmer.

Step 4. Loosen, but do not remove the two mounting screws (a & b) from the dimmer cabinet backplate.

b

Step 5. Slide the module upward and pull out.

Step 6. Before inserting the new dimmer module, set the dip-switch on the replacement dimmer to match the dimmer being replaced.

Step 7 Insert the new module in place and reverse the process from Step 5. Turn on circuit breaker when the work is completed.CAUTION

!

SW1 DimmerDip-Switch

Rev12/2006

15

ON2

34

67

8

Note 2: On STANDARD, NON-DIM, and ELV dimming modules, each has a 3-pin connector.

LOAD

LINE

NEUTRAL

3-Position Connector

3-Pin Connector

4-Position Connector

4-Pin Connector


Recommended