For Protection of ConveyorsElectronic Speed Switches : Protection against Zero / Under / Over speed condition Features=
=
=
=
=
=
=
=
=
=
=
Under / Over / Zero speed protection.Cast Al / Poly carbonate / Polyester enclosure.
Multi range model for reducing inventory. Range 5 to 5000 RPM selectable. Built in initial start up Nuisance time delay. Contact 1 NO+1NC, 2 NO+2NC. 4 to 20 mA retransmission output. IP65 grade protection.Digital display models. Non contact type sensor probe. Size :M18/M30/M50/M80Intrinsically safe model available.Sensor probe with extension stand.
Electronic Belt Loading MonitorModel : BLM5511Application = To monitor load as well as well as speed of the conveyor.
OPERATIONAL FEATURES TD - Built in initial bypass Delay NTD - Nuisance Delay NITD - Combined Nuisance + Initial Delay DD - Digital Display S - Selector switch for multi range.
Heavy duty Limit Switches Model - HLS 802 Features =
=
=
=
=
=
=
Heavy duty enclosure for dusty environment.Cast Al / cast iron. Robust spring to absorb the belt impact. Grade of protection IP65. Heavy duty contacts 16 Amp @ 240VACContact combination 1No + 1NC / 2NO + 2NC / 4 NC Retaining type Screws.
ESM 4411 - TD - CA - 55 - 11 - 30
BASIC TYPE ESM4410 - Speed Indicator ESM4411 - Under speed monitor ESM4412 - Over speed monitor ESM4413 - Under + Over speed monitor ESM4414 - Under speed with extension stand
PROBE SIZE M18, M25, M30, M50
OUTPUT CONTACT COMBINATION 11-1 NO + 1 NC 22-2 NO + 2 NC
PROTECTION GRADE IP 30, IP55, IP 65
SELECTION TABLE
Please follow the nomenclature as below.
ENCLOSURE TYPE MS - Sheet Metal CA - Cast Aluminum PL - Plastic / Poly carbonate SS - Stainless Steel for Chemical
Belt Monitoring Switches
www.maitryinstruments.com
For Protection of Conveyors
Belt Sway Switch Features =
=
=
=
=
=
=
=
=
Heavy duty enclosure for dusty environment. Cast Al / cast iron / Poly carbonate enclosure. Ball / bush bearing options for roller & cam shaft. Grade of protection IP65. Heavy duty contact 16 Amp @240VAC Contact combination 1 NO+1NC / 2NO+2NC. Auto reset type. Retaining type screws. Robust spring to absorb the belt impact.
Pull Cord SwitchFeatures =
=
=
=
=
=
=
Heavy duty enclosure for dusty environment. Cast Al / cast iron / Poly carbonate enclosure. Retaining type screws. Heavy duty contacts 16 Amp rating 240VAC, Contact combination 1NO+1NC / 2NO+2NC. Manual reset. Models available with junction box / with indicating lamp / with mechanical flag.
Ordering Code
S B S 3 0 - 1 - C A - T B - F - L -
Basic Model
1 + 1 NO + 1 NC 2 + 2 NO + 2 NC
Enclosure CA - Cast Al.PL - Poly CarbonateCI - Cast Iron
Indicating Lamp
flag Indicator
With Junction Box
S B S 4 0 - 1 - C A - T B - L - D
1- 1 No. + 1 NC2- 2 No. + 2 NC
Enclosure CA - Cast Aluminum PL - Poly CarbonateCI - Cast Iron
With Junction
Box
Indicating Lamp
Handle roller & shaft with ball bearings
Basic Model
Ordering Code
Belt Monitoring Switches
www.maitryinstruments.com
Encoder is light sensor that detects and converts mechanical transfer or displacement into electric signal. It detects the position, speed, angle by means of converting analog signal generated from a revolution of the shaft into digital signal by the internal fixed circuit.Output Circuit Types :1) Open Collector 2) Push Pull Output 3) Line DriverOutput Channels1. A,B PhaseThe output signal of A, B phase are output with 90 of phase difference. It is the signal to discriminate the rotation direction.2. Z PhaseOne Z phase is output per one rotation, which is called origin signal.Resolution (Pulses per Revolutions)
means the number of pulse which is output from 1 revolution of the rotating shaft of rotary encoder. In case of incremental encoder, it can be indicated in the number of rotating slits, in case of Absolute encoder, it can be indicated in number of divisions or bit High resolution from 100 to 6000 P/R Power Voltage : 5 VDC/24 VDCOuter Diameter : 30,40,48,58 mmShaft Diameter : 6mm, 8mm
Specificationsl
l
l
Din Rail mounted signal converter / isolator is available in different input. 0-5mVDC / 0-20mVDC / 0-50mVDC / 0-100mVDC / 0
10mADC / 0-20mADC / 4-20mADC / 0-5 VDC / 1-5 VDC / 0-10VDC / 0-5Amp / 0-1 Amp or customer specified, up to 3 outputs are available with all port isolation i. e. supply to input / supply to output / input to output and output to output channel isolation.Unit is available in 24VDC, 110VAC and 230VAC supply.
Signal Isolaters & Converters
Ultrasonic Sensors l
l
l
l
Size : M18/30 Supply : 24VDC Output : 0-10 VDC / 4-20 mA Sensing Dia : 600mm /1500mm
Rotating Paddle Type l
l
l
Motor torque adjustableSpecial Clutch mechanism to protect Motor Sealed bearing for Rotating shaft.
Magnetic Level Switchl 2,3,4 point Switching Available
Photo Electric Level Sensor l
l
l
l
l
l
Infrared Sensor for liquid Level detectionEx-proof Supply : 24 VDC Output : PNP/NPN TypeDimension : 3/8 x74 mmMounting Material : Polysulphone
Vibrating Fork Type l Suitable for highly dusty environment
Rf Admittance Type l
l
l
l
Three Element Coat Guard Technology Ignores material build - up on Probe Applications : Sand levels, Cement, Lime etc. Supply : 24 VDC, 230 VAC Output : 2No+2NC
Level Sensors
Rotary Encoders
www.maitryinstruments.com
Operating Principle
Advantagesl l
l l
l l
l l
Enclosure
Operating Temperature
Protection
Mounting
The LC oscillator circuit generates the electromagnetic field over the active face, energy is drawn from oscillator. resulting damping of the oscillator. This Change is detected by the electronic circuit to give output signal.
Non Contact Operation Corrosion Resistance High Operating Frequency IP 67 Grade of ProtectionBounce Free Operation Repeat accuracy ± 0.02 mmVibration Resistance Long Life
Proximity Switches are available in Tubular shape made of BRASS , S.S., M.S. Other odd Shape Switches or as per customer requirement can be made available on request.
0Operating Temperature of Proximity Switches is O c to 55 c. 0Temperature up to 100 c can be manufactured on request.
AC Switches are protected against transients and surges. DC Switches are protected against Short Circuit and Reverse Polarity.
In case of Flush Mounting the sensing distance is limited to 0.8 times of the sensing distance for Non Flush Type.
Miniature Sensors
Types of Inductive Proximity Switches
Our miniature sensors with short circuit protection M 8 x 30 mm & M 12 x 30 mm with LED Indication
AC Proximity Switches - Type PS 12These are available in 2 wire and 3 wire as shown. These switches are to be connected in series with the load. Operating Voltage : 110VAC/240VAC/90-240VAC
Logic : NO/ NC/COLoad : up to 500 MA
Dimensional & Technical Specification
Intelligent Sensors in Automated Processes
2 Wire 3 Wire
REDRED
BLACKBLACKGREEN
LOAD
LOAD
p
N
LOAD
p
N
IPS IPS
Load Current Size Sensing distance in ma mm in mm
Flush Non Flush For AC For DC
Ø 6.5 1 - - 250
M 8 1.5 2 - 250
M12 2.5 3.5 250 250
M18 5 7 400 250
M30 10 12 400 250
M 36 15 18 400 250
M50 15 20 400 400
M80 30 35 - 400
17X17X36 7 - 250
20X20X38 7 - 250
26X12X40 3.5 - 250
40X40X112.5 13 20 400 400
d d d
Ste
el
Steel
2xsn d
3xd
LED
L
A/F
Tubular Switches : Enclosure Type
Size 12 18 24 30 36 50
DC 50 70 65 70 70 65
AC 80 70 70 70 70 65
DC Proximity Switches - Type PS 13These are available in 3 wires as shown. Special models of 2 wires and 4 wires are available on requestOperating Voltage : 5V to 30V DC (up to 220V DC on request)
Logic : NPN / PNPLoad : up to 400 MA
3 WireNPN
3 WirePNP
RED
BLACKGREEN
+
_ _
+
BLACKGREEN
LOAD RED
LOAD
IPS IPS
Inductive Proximity Switches
Maitry Instruments & Control offers you a
wide range of high quality Proximity Switches. these are used in all areas of control & automation such as Machine Tools, Packaging, Injection Moulding, Automobile Industries, Process Industries, Textile Industries and other Automated Systems.
www.maitryinstruments.com
Intelligent Sensors in Automated Processes
Adjustment Sensitivity Size : M18, M30 Supply : 10-30 VDC/ 240 VAC Logic : PNP / NPN / NO / NC Enclosure : Brass / Plastic
lllll
M8 x 45
26 x 12 x 4020 x 20 x 50
20 x 20 x 38
25 x 25 x 65
40 x 40 x 112.5
17 x 17 x 36
M30 x 80 M12 x 50
40 x 40 x 112-5 20 x 16 x 12
M50 x 80
M5 x 30 M18 x 80
8 x 8 x 40 Gap Size : 10 mm
T Shape : 10 mm50 x 22 x 4250 x 25 x 10
Inductive Proximity Switches
Capacitive Proximity Switches
www.maitryinstruments.com
Applications
Specifications
l
l
l
l
l
l
l
These are widely used for sensing metals and non-metals like wood, glass, paper and water, etc.These switches are used for automation in various industries like pharmaceutical machines, packaging machines, food processing, textile machines, conveyor systems, Automobile engineering industries, Chemical Plants, Cement Plants, Safety and Security appliance.
Supply : 10-30 Volts DC
Output : NPN or PNP type
O/P Current : 200 mA (Max.)
No Load Current : 5 - 10 mA approx.
Drop across switch : Less than 1 Volt
Switching frequency : 100 Hz., 2KHZ
Protection : Reverse Polarity and
Short Circuit Protection
Any Shape/ Any Size 2 Wire, 3 Wire D. C. version Available
Diffuse Scan Sensor
Through Scan Sensor
Retro - Reflective Sensor
Fork/Slot Sensor
Fork Gap : 50, 5, 20, & 3 mm.
M12 x 60M18 x 55
M18 x 75
M18 x 55
17 x 50 x 55
17 x 50 x55
60 x 20 x15
70 x 50 x15 70 x 50 x1590 x 70 x 15
17 x 50 x 55
Optical Proximity Switches
Magnetic Proximity SwitchesMagnetic Proximity Switches
www.maitryinstruments.com
Maitry Instruments & Control offers
Optical Proximity Switches with modulated infrared beam consisting of a transmitter and a receiver. The state-of-the-art modulation and detection circuit ensures reliable operation of sensors in hostile environment and are unaffected by temperature variation and stray light.
Salient Featuresl
l
l
l
l
l
SpecificationInput voltage
Low cost, high reliability.High efficiency and high working temperature Compact size, lightweight 100% full load burn - in test. Short circuit / overload protected / over voltage protected.Built-in EMI filter, low ripple noise.
: 90 to 270 AVCInput frequency : 47 to 63 HzInrush current : Cold start Limited by NTC
thermistorOverload protection : Constant voltage, constant
current105% to 120% output foldback limiting.
Holdup time : Greater than 20 m sec.High voltage test : I / P to O / P 3 KV 1 min.,
I /P to O/P 1.5 KV 1 min.Safety standards : As per UL 1012 requirementEMC & EMI : Tested for FCC class ACooling : Natural CoolingNoise suppression : By means of heavy duty
EMI and RFI filtercan with stand 2 kV noise between Line & N, L & Earth, N &E.
0Operating Temperature : 0 to 55 C I/P voltage surge protection : By means of proper rating
MOV
For Bowl / Liner feeders New Advance Version (CVCF) Constant voltage, constant frequency controllers for smooth vibration and constant feed rate irrespective of change in supply voltage and frequency for Genset application.
Supply : 230 / 41 5 VAC 2 phase 50 HzCurrent : 3/6/10/15/30 AmpVoltage setting : Via potentiometer / 4 to 20 mA
control signalRetransmission O/p : 4 to 20 ma for PLCProtections : Overload and fast acting fuses.
Specification
144 x 72 x 115144 x 96 x 115
144 x 144 x 80 160 x 160 x 240
96 x 96 x160
Model Available5VDC upto 20 Amp
12VDC upto 20 Amp24VDC upto 20 Amp48VDC upto 10 Amp
60VDC - 5 AmpCombination Models
are also available.
130 x 70 x 55162 x 96 x 105
140 x 80 x 65
Switching Mode Power Supplies
Electromagnetic Vibrator Controllers
Maitry Instruments & Control Offers you a wide
range of high quality Switching Mode Power Supplies. These are used in all areas of control and automation such as Machine tools, Packaging, Injection Moulding, Automobile Industries, Process Industries and other Automated Systems.
www.maitryinstruments.com
Common Features :l
l
l
l
l
l
l
l
l
RTC Format Display 00.00 to 23.59Bright red 0.56" seven segment display for time indicationUser-friendly programming using tactile switchesProgram enable providedMemory back-up in case of power failure for one weekOperating Voltage range : 85V to 265V AC.1 C/O relay rated for 10A @ 250V AC / 28V DC (Resistive)Dimension : 72 x 72 x 85 mmProgram Steps : 4 / 8 /30
On Delay / Int / Cyclic Mode
Display : Single / Double Display typeSetting : By front key pad / Thumbwheel typeReset : On front / power ON resetOutput : 2 C/ O relay contact 5 Amp / 230VACSupply : 230V / 110VAC +/- 10 %, 50 HzSize : 48 X 48, 72 X 72, 96 X 96, 48 X 96 Range : 0-9999 / Hr. sec / minOptional : Auto reset
Single set / dual set point Memory facility
Specifications
Setting : Keypad / ThumbwheelRange : 999999 countsDisplay : Single /DoubleInput : PNP / NPN Proximity, Limit switch, Encoder or 230VAC pulseOutput : 1 C/ O, Relay, 5 Amp / 230VACReset : Manual / Auto reset selectable by key pad
(Reset time selectable by keys in auto mode)Supply : 230C / 110VAC +/- 10 %, 50 HzSize : 48 X 48, 72 X 72, 96 X 96 Optional : Reset on back terminal
Dual set point Programmable scale factor
Up-down counter ( for encoder input)
Event / Preset / Length Counters
Specifications
Digital Timer
Weekly Timer
Digital Counters
www.maitryinstruments. com
Specificationsl
l
l
l
l
l
l
l
l
l
l
l
Micro processor Based Scanner is available in 8 /16 channel, sensor input available universal T/C type or RTD or analog signal (0-5V / 1-5V / 0-10mA / 4-20mA or resistance potentiometer) or mixed input sensors, individual channel input and high / low alarm is programmable from front key.Available in 90-270 VAC or 24 VDC supply.Isolated communication port for RS232 or RS 485Inbuilt 16 Relay output ( High or Low ) Individual alarm indication LED ( 16 Channel )User programmableAlarm logicRelay groupingSensor break logicChannel name 8 CharacterAlphanumeric LCD displayUnits display
Specificationsl
l
l
l
l
l
l
l
l
l
Display : Single / Double 4 digit non-contact (RPM indicator) Bright red.0.5 seven segment displayRange: 1 RPM to 9999 RPMAccuracy : +/- 1% of FSUser programmable speed limit trip point with keypad 2 C/O relay output rated for 5A @ 240VAC /28VDC (Resistive) Accepts NPN /PNP proximity switch inputs Input : 1 pulse per revolutions / Scale Factor Supply 110V / 230VAC Dimensions: 48 X 96, 72 X 72, 96 X 96
SpecificationsMicroprocessor based 8 / 16 /32 channel alarm annunciator accept input from potential free contacts, power supply available 230VAC or 24VDC or customer specify flashing rate 55/60 flash per minute, front key switch available for ACCEPT and TEST as well same function is available on back panel for remote operation, additional power contact through relay is available for alarm signal to connect warning light / hooter etc.
Micro-processor Based Scanner
Digital Rpm Indicator / Controllers
Alarm Annunciator
www.maitryinstruments. com
Basic Features=
=
=
Multi-input and multi - range performance Includes a new processing system, Expert PID, remarkably improved PID control efficiency; overshoot and undershoot are controlled effectively. The keylock function can avoid erroneous operation resulting from set values or parameter settings. High/Low alarm available as basic feature.
SpecificationsInput sensor
0 a. Thermocouple : Iron-constantan (Fe / con)-up to 400 C0 Chrome l- Alumel (Cr /Al)-up to 1200 C
Platinum-Platinum-Rhodium (Pt/Pt-Rh-13%) 0up to 1600 C
b. RTD : Resistance Temperature Detector ( Pt-100) low 0temperature & up to 400 C
Accuracy : +/-0.5% of FSDCompensation : Cold junction compensation automatic for all
thermocouple modelsRelay Output : One change over relay contact 5 Amp / 230VAC
ratingControl Action : ON-OFF or time proportionalControl version : Single set point or Dual set pointPower Supply : 230VAC+/-105.50Hz
0Max. Ambient temp.: 55 CSetting : Keypad / Knob / Push to setSize : 48 X 48, 72 X 72, 96 X 96,48X96
Types of Thermocouples :
Types of Resistance Temperature Detectors :
Types of Insulations :
Types of Junctions :Types of Sheaths :
Shapes & Sizes : Mounting Accessories :
'K' (Chromel - Alumel ) ,'J' (Iron-Constantan). 'T' (Copper-Conslantan), 'E' (Chromel- Constantan), 'R' (Pt-Pt-13%-Rh) ; 'S' (Pt-p 10%-Rh), 'B' (Pt-13%-Rh-Pt-6%-Rh) in Simplex. Duplex and Triplex.
Pt-50, Pt-100, Pt 500, Pt-1000, NI-100, Cu-2000 in Simplex, Duplex and Triplex.
Ceramic Insulation and Mineral Insulation.
Grounded, Ungrounded (Isolated),Mild Steel, SS-304, SS-316, SS-310. SS-
446. Inconel -600, Inconel - 800. Titanium. Cast- Iron, Nickel, Ceramic (610), Recrystlised Alumina (KER-710), etc.
Asper your requirement or application. Thermocouple and RTD
connectors, BSP / NPT / UNF/ Metric threaded Male Female adjustable ferrule fitting in Mild Steel/ Stainless Steel-304/316/Brass etc. All type of flanges available as per standard table and as per your requirement or application considering pressure in Mild Steel, Carbon Steel, Stainless
- 40 to 760
- 40 to 1260
- 184 to 371
- 50 to 1741
- 50 to 1767
- 200 to 550
'J' (Iron-Constantan)
'K' (Chromel-Alumel)
'T' (Copper-Constantan)
'R' ( Pt-Pt-13%-Rh)
'S' ( Pt-Pt-13%-Rh)
( 100 othms RTD Pt-100 Bullb)
1
1
1
1
1
1
Temp. range in C Type of Thermocuple
Resolutionin C
Selection of Thermocouple Type as per temperature
Features :PID, ON/OFF, Manual & PID modes. Universal input.Relay/SSR/Analog output.(Current & Voltage)Size : 48x48, 48x96, 72x72, 96x96 Heating /Cooling output available. Auto tuning facility. Retransmission output.
= =
=
= =
= =
AutoTuned PID Controllers
Temperature Sensors
Digital Temperature Indicator / Controllers
www.maitryinstruments. com
Input (Control)
For the electrical heating system to control the temperature at the set point by switching contractors has many disadvantages, such as wear and tear, limited life of contractor, noisy operation. Besides these it has limited accuracy due to limitation of speed of operation, hence loss of power. All above mentioned disadvantages are eliminated by SCS Thyristor Controller.
All types of Electrical Heating Systems.
Infrared Ovens.
Vacuum Brazing Furnace.
Continuos Annealing / Bell Furnace.
From medium to higher capacity
or single / three phase load
Sturdy and Rugged Design.
Facility of Local and Remote Operation.
Good accuracy over full range.
Better external noise immunity.
Built-In
Adjustable over current limit.
dv / dt protection by RC snubber.
Applications
l
l
l
l
Salient Features
l
l
l
l
l
Standard Protections
l
l
Energy conservation + Better results
General Specification
Standard Capacities
Input : Single/Three phase AC 50 Hz. Output : 0-95% of rated input. (lockable
50-100%) Control Signal : Local-Multiturn potentio meter.
0Ambient Temperature : 45 C Max.
Single Phase up to 10 kw Three Phase up to 200 kw
Relay ModulesRelay modules are available like 2/4/8/16 channel with base with fuse protection, Relay O/p = 1C/o / 2C/o contacts.
Output (load)
Specifications Min. Max. Units
Output Current rating with heat sink 0.05 10 25 AMPS
15,40,60 RMS
Load Voltage rating 25 480 VAC
( RMS )
Frequency rang 47 70 Hz
Surge Current rating ( 20ms ) at 40 amp type 425 AMP
Over voltage rating ( transisent peak ) 1200 V Peak
Specifications Min. Max. Units
Control Voltage Range 3 32 VDC
75 240 VAC0 0Input Current -40 C < ta < 80 C 20 mA
Turn off Voltage - 30 c < ta < 80 C 1 VDC
4 VAC
Turn on Voltage - 40 C < ta < 80 C 75 260 VAC
Isolation ( Input to Output, 10 OHMS
Input to case Output to case )
Thyristrised Power Controller
Solid State Relays & Relay ModulesMaitry Instruments & Control offers wide range of solid
state relays. Solid state relay is a static electronic switch unlike in an electromechanical relay where switching takes place between two moving contacts, Switching in SSR takes place across the junction of semiconductor device. Devices are Triac or Thyristor for AC switching & Transistor for DC switching. In most SSRs galvanic separation is achieved by Optocouplers equipped with integrated trigger circuit. (optotriac) provide the switching function required for the corresponding load type.
Maitry Instruments & Control Manufacture SSRs
from current rating 2A to 150 Amp.Output Voltage : 240 v or 600 VAC.DC output relays with rating 110 VDC 10 Amp. to 100Amp.
www.maitryinstruments. com