8
Make the Switch to Quality, Reliability and Convenience Competitors-at-a-Glance
Transcript
Page 1: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Make the Switch to Quality, Reliability and Convenience

Competitors-at-a-Glance

Page 2: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

This is not just any POC coagulation device.

A Lineage of Trust: Over 40 Years The Hemochron Signature Elite comes from a lineage of trust with POC coordinators for over 40 years, starting with the first to market - tube based Hemochronometer in 1969. The progression of the Hemochron product family has been at the forefront of coagulation monitoring and today the Signature Elite is the established market leader.

Hemochronometer

1969• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

HemochronResponse

Hemochron Jr. II HemochronSignature Plus

HemochronSignatureHemochron Jr.

Page 3: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Overcoming Modern POC ChallengesYour time is crucial and we understand coagulation testing must be efficient and effective so you can focus on all the critical decisions. The Hemochron Signature Elite simplifies the coagulation analysis by overcoming all of the modern POC challenges, so you can focus on patient care.

Point of Care

• Broad Coagulation Test Menu• Configurable Options For Each Hospital’s Compliance Needs• Ready to Connect with Leading Data Management Systems (POCT-1A)• No Maintenance

Perfusion

• ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds)

• Small Sample Size and No Measurement Required

Cardiac Catheterization Lab

• Two ACT Tests Optimized for Specific Procedures (ACT+, ACT-LR)

ECMO • ACT-LR Available for Low to Moderate Heparin Concentrations

Oral Anticoagulation Clinic

• Both Fresh and Citrated PT/INR Available

Critical Care• ACT-LR Available for Low to Moderate Heparin Concentrations• APTT Available for Low Heparin Concentrations

Emergency Department

• 3 Month Room Temperature Shelf-Life - Reduces Warm-Up Time

• Broad PT/INR Intended Use Allows Flexibility in Patient Applications Such as Stroke Protocol.

Page 4: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Broad Test MenuCompared to other coagulation analyzing platforms, the Signature Elite has one of the broadest coagulation test menus. This allows all departments within a hospital to standardize their own coagulation testing applications on one device.

Hemochron Signature Elite1

Abbott i-STAT2

Medtronic ACT Plus3

ACT High Range

ACT Moderate Range

ACT Low Range

PT/INR

APTT

Citrate PT/INR

Citrate APTT

Hemochron Signature Elite Heparin Ranges1

Each test with Hemochron Signature Elite has an established heparin sensitivity range providing confidence for it’s intended application. Other manufacturers may not specify their heparin sensitivity ranges.

ACT+• Monitors moderate to high heparin concentrations• 1-6 units/mL

ACT-LR• Monitors low to moderate heparin concentrations• Up to 2.5 units/mL

APTT• Monitors low heparin concentrations• Up to 1.5 units/mL

Page 5: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Stable Fibrin Clot

Hemochron Signature Elite

Detects Clots Here

Factor Xa

Fibrin

ThrombinProthrombin

Fibrinogen

Clot Detection Method:

Common Pathway:

Abbot i-STAT Stops Here

True End-Point Clot Detection Signature Elite uses a mechanical-optical method to detect a true end-point clot. Compared to other platforms that use an electrochemical method to detect a thrombin substrate, Signature Elite’s detection method actually reflects the formation of a fibrin clot. This provides confidence that the target time results are measured from an accurate representation of the clotting process.

Small Sample Volume1 Drop. 2 Drops. Done! Signature Elite test cuvettes only require 1-2 drops of the blood sample to get a fast and accurate result. It’s simple and requires no additional sample preparation or measuring to get your coagulation test started.

Hemochron Signature Elite4

Abbott i-STAT2

Medtronic ACT Plus3

1-2 drops (~35 µL) 40 µL 200-400 µL

Hemochron Signature Elite4

Abbott i-STAT5

Medtronic ACT Plus3

Mechanical Optical

Electrochemical(Not a True End-Point Clot)

Photo-Optical

Page 6: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Instrument Assays Shelf Life At Room Temperature

Hemochron Signature Elite4 3 Months**

Abbott i-STAT6 2 Weeks

Medtronic ACT Plus7 Until Expiration Date

Room Temperature StabilityHaving a long shelf life at room temperature allows your team to reduce refrig eration storage and save the time and resources associated with monitoring and documentation. Hemochron Signature Elite test cuvettes are designed to have up to a 12 week shelf life** at room temperature giving hospital departments the flexibility to use immediately in critical moments.

RapidCount Technology RapidCount technology is exclusive to the Hemochron Signature Elite’s ACT+ tests, which provides accelerated results. The difference is measurable when you compare that to other platforms that may take 8 minutes or more to get an ACT result.

**Room temperature shelf life cannot exceed the manufacturer’s documented expiration date.

Achieved in...

Compared to...

~4.5 Minutes (Therapeutic Target Time of 420 CES*)The Fastest ACT+ Count

Signature Elite ACT+ Target Time

8 Minutes (Therapeutic Target Time of 480 Seconds)With i-STAT and Medtronic ACT Methods

*Celite Equivalent Seconds - The ACT+ clotting time is displayed as a Celite equivalent ACT value based on a correlation study established in a clinical study.4

Page 7: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

Switching to Signature Elite Just Got Better

OID/PID ScanningEliminate transcription errors

and shorten lead times to enter OID/PID information.

POCT1-A Compatible

Direct access to hospital networks facilitating patient

management.

Maintenance Free

Less hands on time for preparation, so you can focus on

the more important deliverables.

PortableSmall and light

enough to take from bedside to bedside

with no effort.

Simple 4-Step Process

•1 Scan/Insert Cuvette

•2 Enter PID/OID•3 Add Sample/Run

•4 Get Results

User LockoutsMaintain the

safety and security needed for your

organization.

Automated EQC Configurable to

automatically run at any time interval without external

cartridges or additional accessories.

Page 8: Make the Switch to Quality, Reliability and Convenience · • ACT+ Results in ~4.5 minutes (Therapeutic Target Time of 420 Celite Equivalent Seconds) ... Small Sample Volume 1 Drop.

MSIG0030 00

Accriva Diagnostics, Inc. | 6260 Sequence Drive | San Diego, CA 92121 USA

Tel: 858.263.2300 | Toll-Free: 800.631.5945 | www.accriva.com

MADE IN THE USA

• AC

CRIVA DIAGNOSTIC

S •

ACCRIVA DIAGNOSTICS

MADE IN THE USA

MADE IN THE USAACCRIVA DIAGNOSTICS

Find out MoreHemochron Signature Elite is a comprehensive point-of-care coagulation monitoring system. Ideal for the wide variety of applications found in today’s busy health care facilities.

To learn more, visit www.accriva.comUS Customers: 800.643.1640 | International Customers: 858.263.2501

Ordering Information

Catalog Number Description

ELITE Hemochron Signature Elite Whole Blood Microcoagulation System

ELITEINT Hemochron Signature Elite Whole Blood Microcoagulation System (International)

JACT+ ACT+ test cuvette — Silica and kaolin based Activated Clotting Time test cuvette*

JACT-LR ACT-Low Range test cuvette — Celite® based Activated Clotting Time test cuvette*

J201 PT test cuvette — Prothrombin Time test cuvette* (venous or fingerstick sampling)

J201C Citrate PT test cuvette — Prothrombin Time test cuvette**

J103 APTT test cuvette — Activated Partial Thromboplastin Time test cuvette*

J103C Citrate APTT test cuvette — Activated Partial Thromboplastin Time test cuvette**

* for use with fresh whole blood ** for use with citrated whole blood

Hemochron Signature Elite is a registered trademark of Accriva Diagnostics. ACT Plus is a registered trademark of Medtronic. i-STAT is a registered trademark of

Abbott the Abbott Group of Companies in various jurisdictions. © 2016 Accriva Diagnostics

1. Signature Elite Operator’s Manual (HX1101En Rev 00). 2. i-STAT Online Test Menu (038683 Rev C 06/16) (https://www.abbottpointofcare.com/products-services/istat-test-cartridges/menu) 3. ACT Plus Operator’s Manual (M950403A001 Rev 1A) 4. Hemochron ACT+ Package Insert (FB5935WEU Rev 0515) 5. i-STAT Kaolin ACT Package Insert (Art: 715878-00N) 6. i-STAT Kaolin ACT and i-STAT Celite ACT Packaging 7. ACT Plus Activated Clotting Time Cartridges Instructions for Use (M956357A001 Rev. 1A)


Recommended