PowerHub UPS saves money and energy without sacrificing availability
For more inquiries, please contact sales at 65708068. For more PowerHub product details, log on to www.powerhub.com.sg
PowerHub
Manage both your UPS and your energy proactively
Prime II RT UPS
• Up to 94% efficiency
• Pure sine wave output during battery operation
• Rack/Tower Convertible
• Power Rating of 1KVA to 3KVA
• Online Double Conversion
• High power density, output power factor 0.9
• Patented rotational LCD display
• Selectable high efficiency mode of operation
In order to increase runtime,
power from non-essential
equipment can be removed in
order to give the server more
run time before a shutdown is
necessary.
An intuitive and 2-directional
LCD screen displays detailed
status of the UPS and batteries.
Hot-swappable batteries are
easily accessible via the front
panel and can be replaced by
the user directly
rime II RT UPS, a new generation Rackmount / Tower convertible series with up to
94% efficiency, is an ideal power protection solution for used in areas like finance,
communications, insurance, railway, medical, industrial and enterprises sector. The slim
design and wide range of installation possibilities make the UPS one of the most versatile
UPS available.
Unlike other UPSs that use simulated sine wave, PowerHub Prime II RT UPS provides pure
sine wave output during battery operation. This results in the connected devices receiving
high quality electrical input and operates smoothly in the event of power outage.
P
2-Directional LCD Panel
Load Shedding Functions
Hot Swappable Battery
Keep your world up and running with PowerHub Prime II RT
Energy-saving and environmentally-friendly functions
EXCELLENT PERFORMANCE HIGH RELIABILITY BEST QUALITY
Built-in chargers within the UPS and the External Battery Pack (EBP) reduces the
battery charging time and enabling them to be charged to 90% capacity in just 5
hours. In this way, a maximum recharge can be guaranteed between successive
power cuts.
Cold start function enabling emergency
starting of connected hardware when the
UPS is not powered up.
Automatic restart of Prime II RT when
power is restored. Batteries charge up as
soon as there is a power supply.
In this way, the Prime II RT saves 50%
more energy than a normal UPS.
The PowerHub Prime II RT UPS range is dedicated to the electrical protection of your IT networks
and loads against power supply problems and electrical disturbances.
PowerHub Prime II RT UPS with
excellent connectivity and
communication features provide
FULL PROTECTION against all
nine types of power problems.
9 Levels Of Power Protection
MODELS Prime II RT
1K-SS (Std/Ext)
Prime II RT 1.5K-SS (Std/Ext)
Prime II RT 2K-SS (Std/Ext)
Prime II RT 3K-SS (Std/Ext)
Rating (VA/Watt) 1000/900 1500/1350 2000/1800 3000/2700
Dimension WxDxH (mm)
440x430x2U (UPS) 440x430x2U (EBP)
440x430x2U (UPS) 440x430x2U (EBP)
440x572x2U (UPS) 440x572x2U (EBP)
440x696x2U (UPS) 440x696x2U (EBP)
Weight (kg) 15.7 (Std) / 11.5 (Ext)
19 (EBP)
18.7 (UPS) / 11.5 (Ext) 24 (EBP)
26.3 (UPS) / 17.5 (Ext) 33.6 (EBP)
33 (UPS) 46 (EBP)
TECHNICAL SPECIFICATIONS
Input Voltage: 200/208/220/230/240VAC
Frequency Range :
Electrical Input
Power Factor: 0.9
Crest Factor: 3:1
Efficiency: 90% max (online mode) <94% (high efficiency mode)
Transfer Time: 0ms (Mains - Battery) <4ms (Mains – Bypass)
Charger Current: 1.4A (Std), 6A(Ext)
Typical Recharge Time: 8 hours (to 90% capacity)
Overload: 30s (100% ~ 150%) 300ms (>150%)
Output Voltage: 200/208/220/230/240 VAC± 2%
THD: <3% (linear load), <5% (non-linear load)
Electrical Output
Noise: <50dB
Operating Temperature: 0 ~ 40˚C
Relative Humidity: 0 ~ 90%, No condensation
Altitude: <1500m
Environmental
Safety: IEC/EN62040-1, IEC/EN60950-1
EMC: IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Standards
Copyright © 2016 APECUS TECHNOLOGIES
All rights reserved
Printed in Singapore Rev 2.0
MODELS
Battery Voltage (VDC) 24 36 48 72
BATT Type / Number 12V/9Ah x 2 (UPS) 12V/9Ah x 4 (EBP)
12V/9Ah x 3 (UPS) 12V/9Ah x 6 (EBP)
12V/9Ah x 4 (UPS) 12V/9Ah x 8 (EBP)
12V/9Ah x 6 (UPS) 12V/9Ah x 12 (EBP)
BATTERY
Communication: RS232, USB, Relay card (optional), SNMP card (optional)
Display: LCD indicates Load/Battery/Input/Output
Alarm: AC failure, Low battery, Overload, Fault
Others
PowerHub Prime II RT Series
PowerHub
Due to ongoing product improvements, specifications are subject to change without notice.
50Hz - 45~55Hz, 60Hz - 55~65Hz
APECUS Technologies Pte Ltd
7030 Ang Mo Kio Ave 5
#06-50 Northstar@AMK
Singapore 569880
Tel: (65) 6570 8068
Fax: (65) 6570 8066
Website: www.apecus.com
Email: [email protected]