Report Ref: PR13/0006 Page 1 of 76
MANAGEMENT ASBESTOS SURVEY AND REGISTER
SITE SURVEYED
Porchester Sailing Club, Waterside Lane, Castle Street,
Porchester, Hampshire.
ON BEHALF OF
Solent Environmental Services (Asbestos) Limited
On
8th February 2013
Document prepared by: - Stuart Stephenson
PO Box 311, Alton, Hampshire GU34 9HA Tel: 0845 4673477
Email: [email protected] Web: www.safeguard-asbestos.co.uk
Safeguard A.S. Ltd
Report Ref: PR13/0006 Page 2 of 76
SECTION 2
TABLE OF CONTENTS
1. Cover Sheet
2. Table of Contents
3. General site & Survey information With Signatory Sheet
4. Executive summary/conclusions and actions
5. Introduction
6. Material Assessment Method & Key
7. Survey results
8. Certificates of Analysis
9. Plans (with cross reference sample/item table)
Report Ref: PR13/0006 Page 3 of 76
SECTION 3
General Site & Survey Information With Signatory Sheet
Report Ref: PR13/0006 Type Of Survey: Management
Survey Date: 8th February 2013 Report Issue: 13th February 2013
Survey Carried Out By:
Safeguard A.S. Ltd PO Box 311 Alton Hampshire GU34 9HA
0845 4673477
Surveyor/s: SA Stephenson (Lead Surveyor), & MS Stephenson
Client:
Solent Environmental Services 151-153 Long Lane Holbury Southampton Hampshire
Client Contact: Brian Jones
Site Surveyed:
Porchester Sailing Club Waterside Lane Castle Street Porchester Hampshire
Areas Included: Site.
Areas Excluded: None
Signed:
SA Stephenson (Lead Surveyor) 13th February 2013
This report and its contents therein, form the opinions and results of Safeguard A.S. Ltd. All aspects of the production of this report have been done in strict adherence to documented in-house procedures. The content of this report may not be amended or altered in any manner by a third party without the express prior consent of Safeguard A.S. Ltd. Any further duplication of this survey must be done in its entirety. All relevant liabilities (actual, assumed or otherwise), under such circumstances will be withdrawn forthwith. This report may be used for contractual or engineering purposes unless stated on the front cover sheet. Further architectural or technical plans may need to be sought for major building work. Please note Safeguard A.S. Ltd cannot be held responsible for the way in which the client may interpret or act upon the results of this report.
Report Ref: PR13/0006 Page 4 of 76
SECTION 4
Executive Summary
Safeguard A.S. Ltd were requested to carry out a ‘Management’ survey of Porchester Sailing Club, Waterside Lane, Castle Street, Porchester, Hampshire.
Material Type Asbestos Type
Item Number (Sample Number)
Quantity Location/ Description
Condition Accessibility Surface Treatment
Material Rating
Textured Coating
Chrysotile 4 (2)
>50m2 Gents’ toilets textured ceiling coating
Good Medium Sealed Very Low
Composite Chrysotile 5 (3)
<10m2 Gents’ toilets sink pads
Good Easy Sealed Very Low
Composite Chrysotile 10 (5)
10-50m2
Ladies’ changing room grey floor tiles under carpet
Good Medium Sealed Very Low
Composite Chrysotile 12 (6)
<10m2 Canteen area blue floor tiles
Good Easy Sealed Very Low
Composite Chrysotile 13 (7)
<10m2 Canteen area white floor tiles
Good Easy Sealed Very Low
Composite Presumed Chrysotile
14 >50m2 Canteen area grey floor tiles
Good Easy Sealed Very Low
Composite Presumed Chrysotile
17 <10m2 Corridor adjacent bar/kitchen grey floor tiles
Good Easy Sealed Very Low
Composite Chrysotile 19 (9)
<10m2 Kitchen sink pads
Good Easy Sealed Very Low
Composite Chrysotile 22 (11)
<10m2 Store adjacent kitchen sink pads
Good Easy Sealed Very Low
Composite Chrysotile 28 (13)
<10m2 Upper bar sink pads
Good Easy Sealed Very Low
Composite Presumed Chrysotile
31 <10m2 Entrance lobby grey floor tiles under carpet
Good Medium Sealed Very Low
Cement Chrysotile 44 (16)
<10m2 Area behind external stores 1-3 cement debris
Poor Easy Untreated Low
Insulation Board
Amosite 47 (15)
10-50m2
Eternal store 2 ceiling panels
Good Easy Untreated Medium
Insulation Board
Presumed
49 10-50m2
Eternal store 3 ceiling panels
Good Easy Untreated Medium
Cement Chrysotile 51 (14)
<10m2 External roof undercloaking
Good Medium Untreated Very Low
Cement Chrysotile 55 (18)
<10m2 External toilet roof tiles
Good Medium Untreated Very Low
Cement Chrysotile 57 (17)
10-50m2
External acetylene store roof/ceiling sheets
Good Medium Untreated Very Low
Report Ref: PR13/0006 Page 5 of 76
Areas requiring attention: The area behind External Stores 1-3 requires attention.
Conclusions & actions: All asbestos containing materials should, either be labelled & managed or removed. Any works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Report Ref: PR13/0006 Page 6 of 76
SECTION 5
INTRODUCTION
1. Safeguard A.S. Ltd were requested to carry out a survey of Porchester Sailing Club, Waterside Lane, Castle Street, Porchester, Hampshire in order to establish the presence of any Asbestos containing materials.
2. The building was of unknown age. The building was of traditional brick/block construction. The internal
fixtures (e.g. partition walls & ceilings) are mostly brick/block/plaster or plasterboard. 3. The scope of work requested is limited to the areas, as identified by the client. 4. A written report including recommendations and photographic data will be submitted by Surveyors
representing Safeguard A.S. Ltd.
LIMITATIONS
5. This report only relates to the situation at the time of the site visit and cannot take into account subsequent changes in circumstances. Materials were sampled if, in the opinion of the Surveyor/s, there was probability that they may contain Asbestos.
6. This report contains findings based upon visual inspection and during the course of the survey; all
reasonable efforts were made to identify the presence of materials containing Asbestos within the surveyed areas.
7. The nature of this survey was a ‘Management’ sampling and identification survey, as defined in the Health
& Safety Executive publication HSG 264. 8. Samples have not been taken where the act of sampling would endanger the Surveyor/s or affect the
functional integrity of the item concerned. For example: fuses within electrical boxes, gaskets, fire doors,
ropes, associated with heating, glazing or power plant etc.
9. Bulk samples have been taken from all materials which upon visual inspection appeared likely to contain
Asbestos with the exception of items of bitumen, plastic, resin or rubber which contain Asbestos, the
thermal and acoustic properties of which are incidental to their main purpose which falls outside the scope
of the Control of Asbestos Regulations 2012.
10. No responsibility can be taken for any misinterpretation of this report by any third parties.
Report Ref: PR13/0006 Page 7 of 76
SURVEY METHOD
11. This survey was by means of visual inspection and subsequent sampling of suspect bulk materials. 12. Where the Surveyor/s suspected a material contained Asbestos, a sample was taken for analysis. The
samples were chosen as being representative of the material under investigation. Therefore, where there are visually similar areas, they should be regarded as being of uniform composition.
SAMPLING STRATEGY
13. The object of carrying out sampling is to identify the nature and extent of any visible Asbestos bearing material.
14. All sampling is undertaken in accordance with Safeguard A.S. Ltd in-house method, based on the HSE
guidance note HSG 264 causing the minimum possible disruption and potential risk to the health of building occupants and visitors.
15. Samples are analysed by a UKAS accredited laboratory. 16. Areas of specific exclusion that have not been surveyed, or that a reliable degree of confidence cannot be
gained of the homogeneity of the area through limited access, can be found in Section 3.
DEALING WITH DEMOLITION OR MAJOR STRUCTURAL ALTERATION
17. If the building is due for demolition or major structural alteration. Current guidance requires removal of all Asbestos containing materials likely to be affected by such works. Where materials are suspected to be present and consist of or contain Asbestos, contractors should (prior to commencing refurbishment works) first confirm the existence of such materials under controlled conditions. Such contractors must be licensed to work with Asbestos materials in accordance with the Control of Asbestos Regulations 2012.
DEALING WITH ASBESTOS INSULATION BOARD
18. These works must be carried out under controlled conditions by a contractor licensed to work with Asbestos under Control of Asbestos Regulations 2012. It should be noted that licensed Asbestos contractors, under the terms of their licence, have to notify the relevant authority of their intention to remove such items. A notification of such works is normally subject to a 14-day period, except for unusual or exceptional circumstances when the enforcing authority (either the Health and Safety Executive or local Environmental Health Department) may grant a waiver if there is immediate risk to health, i.e. an accident.
Report Ref: PR13/0006 Page 8 of 76
DEALING WITH ASBESTOS TEXTURED COATINGS
19. Works on or removal of the Asbestos containing textured coatings (e.g. decorative coatings and paints) should be carried out using precautions in accordance with the guidelines within the Health and Safety Executive guidance ‘Asbestos Essentials’ HSG 210 2012. These guidelines outline basic precautions that should be used to prevent fibre release during works, such as wetting of the materials before removal and preventing unauthorised persons from entering the work area. Using these guidelines, it is expected that Asbestos fibre levels would be low. A contractor before carrying out this work will need to notify the works to the Health and Safety Executive.
20. While there is no requirement of these works to be undertaken by a contractor licensed to work with
Asbestos, in practice it is unlikely that an unlicensed contractor will possess the necessary expertise or carry the necessary insurances to undertake such works properly.
DEALING WITH ASBESTOS CEMENT
21. Works on or removal of the Asbestos cement items should be carried out using precautions in accordance with the guidelines within the Health and Safety Executive guidance ‘Asbestos Essentials’ HSG 210 2012. These guidelines outline basic precautions that should be used to prevent fibre release during works, such as wetting of the materials before removal and preventing unauthorised persons from entering the work area. Using these guidelines, it is expected that Asbestos fibre levels would be low. A contractor before carrying out this work will need to notify the works to the Health and Safety Executive.
22. While there is no requirement of these works to be undertaken by a contractor licensed to work with
Asbestos, in practice it is unlikely that an unlicensed contractor will possess the necessary expertise or carry the necessary insurances to undertake such works properly.
DEALING WITH WOVEN ASBESTOS TEXTILES
23. Works on or removal of the Asbestos containing textiles (e.g. paper linings, cardboards, felt, textiles, gaskets, washers and rope) should be carried out using precautions in accordance with the guidelines within the Health and Safety Executive guidance ‘Asbestos Essentials’ HSG 210 2012. These guidelines outline basic precautions that should be used to prevent fibre release during works, such as wetting of the materials before removal and preventing unauthorised persons from entering the work area. Using these guidelines, it is expected that Asbestos fibre levels would be low. A contractor before carrying out this work will need to notify the works to the Health and Safety Executive.
24. While there is no requirement of these works to be undertaken by a contractor licensed to work with
Asbestos, in practice it is unlikely that an unlicensed contractor will possess the necessary expertise or carry the necessary insurances to undertake such works properly.
DEALING WITH ASBESTOS CONTAINING COMPOSITES
25. Works on or removal of the Asbestos containing composites (e.g. bitumen, plastic, resin or rubber) should be carried out using precautions in accordance with the guidelines within the Health and Safety Executive guidance ‘Asbestos Essentials’ HSG 210 2012. These guidelines outline basic precautions that should be used to prevent fibre release during works, such as wetting of the materials before removal and preventing unauthorised persons from entering the work area. Using these guidelines, it is expected that Asbestos fibre levels would be low. A contractor before carrying out this work will need to notify the works to the Health and Safety Executive.
26. While there is no requirement of these works to be undertaken by a contractor licensed to work with
Asbestos, in practice it is unlikely that an unlicensed contractor will possess the necessary expertise or carry the necessary insurances to undertake such works properly.
Report Ref: PR13/0006 Page 9 of 76
SECTION 6
ASBESTOS MATERIAL RISK ASSESSMENT
27. Safeguard A.S. Ltd provides an in-house numeric material risk assessment method. This takes into account the Product Type, Extent of Damage/Deterioration, Surface Treatments and Asbestos Type. The risk assessment concentrates on the likelihood of fibre release from Asbestos based materials.
28. It may be useful, in particular situations to undertake measurement of atmospheric fibre concentrations; these
levels however, may be open to vast variations, dependent upon conditions and may well be below the concentration measurable using optical microscopic methods but still above local background environmental levels.
29. To achieve some form of standardisation of the action level (as this will vary according to the situation) the
following guidelines have been adopted and are based upon a numerical rating given to the parameters that are considered while conducting the risk assessment. The addition of the scores from each of the parameters results in a number that falls into one of three possible risk categories.
30. The following categories provide the four classifications of potential to release fibres used within this survey.
The higher the number the higher the risk 10 or MORE=HIGH 31. It is likely in situations with such a high rating that persons are currently being exposed to some level of
Asbestos fibre contaminations. Situations with this category will warrant urgent consideration. In most circumstances immediate plans for removal of the Asbestos concerned should be implemented, or at least the rapid sealing up of the affected area.
7 – 9 = MEDIUM 32. Situations within this category do not pose an imminent risk and the likelihood of fibre release is low under
existing conditions. It would be most appropriate within this category to monitor the situation, as obvious deterioration will occur within the passage of time. It is recommended that situations within this category should be inspected on an annual basis to ascertain any change to circumstances.
5 – 6 = LOW 33. Situations within this category are of a low priority. It would be most appropriate within this category to monitor
the situation, as obvious deterioration will occur within the passage of time. It is recommended that situations within this category should be inspected on an annual basis to ascertain any change to circumstances.
4 or Less = VERY LOW 34. Situations within this category are of a very low priority. The situation should be monitored based on an annual
inspection cycle to ascertain any change in category. 35. A quantifiable assessment of the risk of fibre release has been made which takes into account all factors
relevant to the item. Recommended action will normally involve removal, encapsulation or management as described below: -
Ø Removal of those items vulnerable to damage or in such poor condition that removal is the only practicable
option or where refurbishment or demolition works are planned, such that these works will impinge on the Asbestos materials present and render such removal necessary.
Ø Enclosure or Encapsulation (together with repair where necessary) where the material is in poor
condition/vulnerable to damage, such that these works are necessary. Ø Management of the Asbestos materials present, (where these are not in poor condition and are not
vulnerable to damage), by labelling, registering, periodic inspection, as necessary. Such management should be undertaken to comply with the employers’ duty of care, required by the Control of Asbestos Regulations 2006 (see other sections for further such recommendations).
Report Ref: PR13/0006 Page 10 of 76
Material Risk Assessment Key Product Type:
1. Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, semi-rigid paints, decorative finishes, Asbestos cement etc).
2. Asbestos insulating board (AIB), mill boards, other low density insulation boards, Asbestos textiles, gaskets, ropes and woven textiles, Asbestos paper and felt.
3. Thermal Insulation (e.g. pipe and boiler lagging), sprayed Asbestos, loose Asbestos, Asbestos mattresses and packing.
Extent of damage:
0. Good condition, no visible damage
1. Low damage, a few scratches or surface marks, broken edges of boards, tiles etc.
2. Medium damage, significant breakage of materials or several small areas where material has been damaged revealing loose Asbestos fibre.
3. High damage or delamination of materials, spray and thermal insulation. Visible debris.
Surface Finish:
0. Composite materials containing Asbestos: reinforced plastics, resins, vinyl tiles.
1. Enclosed sprays and lagging, Asbestos insulating board (with exposed face painted or encapsulated), Asbestos cement sheets etc.
2. Unsealed Asbestos insulating board, or encapsulated lagging and sprays.
3. Unsealed laggings and sprays. Asbestos Type:
1. Chrysotile.
2. Amphibole Asbestos excluding Crocidolite.
3. Crocidolite.
Report Ref: PR13/0006 Page 11 of 76
SECTION 7
SURVEY RESULTS WITH
ASBESTOS REGISTER
Report Ref: PR13/0006 Page 12 of 76
ITEM No. 1
Location: Basement Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Concrete floor. Timber steps. Timber hatch & frame. Timber/plaster panels & boxing. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit & ducting. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 13 of 76
ITEM No. 2
Location: Entrance Porch Description: Ceiling Panels
Laboratory Ref: PR13/0006/B01 Product Type: Insulation Board
Asbestos Detected: No Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 14 of 76
ITEM No. 3
Location: Entrance porch Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Concrete/quarry tiled floor. Concrete skirting. Timber door & window frames. Timber/plaster/insulation panels & boxing. No visible pipework. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 15 of 76
ITEM No. 4
Location: Gents’ Toilet Description: Textured Ceiling Coating
Laboratory Ref: PR13/0006/B02 Product Type: Textured Coating
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: >50m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 1
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 3
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 16 of 76
ITEM No. 5
Location: Gents’ Toilet Description: Sink Pads
Laboratory Ref: PR13/0006/B03 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 17 of 76
ITEM No. 6
Location: Gents’ Toilet Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Quarry tiled floor. Quarry tiled skirting. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Plastic toilet seats & ceramic cisterns. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 18 of 76
ITEM No. 7
Location: Gents’ Shower Room Description: Textured Ceiling Coating
Laboratory Ref: PR13/0006/B04 Product Type: Textured Coating
Asbestos Detected: No Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Similar elsewhere.
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 19 of 76
ITEM No. 8
Location: Gents’ Toilet Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Quarry tiled floor. Quarry tiled skirting. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live). No access to electric cupboard (locked).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 20 of 76
ITEM No. 9
Location: Ladies’ Toilet/Shower Room Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Quarry tiled floor. Quarry tiled skirting. Textured coatings similar to Sample B04. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Timber toilet seats & ceramic cisterns. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 21 of 76
ITEM No. 10
Location: Ladies’ Changing Room Description: Floor Tiles Under Carpet
Laboratory Ref: PR13/0006/B05 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: 10-50m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 22 of 76
ITEM No. 11
Location: Ladies’ Changing Room Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Tiled concrete floor. No skirting. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
PHOTOGRAPH UNAVAILABLE
Report Ref: PR13/0006 Page 23 of 76
ITEM No. 12
Location: Canteen Area Description: Blue Floor Tiles
Laboratory Ref: PR13/0006/B06 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 24 of 76
ITEM No. 13
Location: Canteen Area Description: White Floor Tiles
Laboratory Ref: PR13/0006/B07 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 25 of 76
ITEM No. 14
Location: Canteen Area Description: Grey Floor Tiles
Laboratory Ref: Similar To PR13/0006/B05
Product Type: Composite Asbestos Detected: N/A
Asbestos Type: Presumed Chrysotile Accessibility: Easy
Estimated Amount: >50m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 26 of 76
ITEM No. 15
Location: Canteen Area Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Tiled concrete floor. Timber skirting. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 27 of 76
ITEM No. 16
Location: Corridor Adjacent Bar/Kitchen Description: Panel Over Door
Laboratory Ref: PR13/0006/B08 Product Type: Insulation
Asbestos Detected: No Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 28 of 76
ITEM No. 17
Location: Corridor Adjacent Bar/Kitchen Description: Grey Floor Tiles
Laboratory Ref: Similar To PR13/0006/B05
Product Type: Composite Asbestos Detected: N/A
Asbestos Type: Presumed Chrysotile Accessibility: Easy
Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 29 of 76
ITEM No. 18
Location: Corridor Adjacent Bar/Kitchen Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Tiled concrete floor. Timber skirting. New style step nosings. Timber door frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 30 of 76
ITEM No. 19
Location: Kitchen Description: Sink Pads
Laboratory Ref: PR13/0006/B09 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 31 of 76
ITEM No. 20
Location: Kitchen & Kitchen Cupboard Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. New style linoleum covered floor. Timber/plastic skirting. Timber beams. Textured coatings similar to Sample B04. Timber/UPVC door & window frames. Timber/plaster/metal panels & boxing. Pipework unlagged. Plastic/metal flues, conduit & ducting. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 32 of 76
ITEM No. 21
Location: Store Adjacent Cellar Description: Textured Ceiling Coating
Laboratory Ref: PR13/0006/B10 Product Type: Textured Coating
Asbestos Detected: No Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Similar elsewhere.
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 33 of 76
ITEM No. 22
Location: Store Adjacent Cellar Description: Sink Pads
Laboratory Ref: PR13/0006/B11 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 34 of 76
ITEM No. 23
Location: Store Adjacent Cellar Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Concrete floor & steps. No skirting. Timber beams. Timber door & window frames. Timber/plaster/metal panels & boxing. Pipework ‘Armaflex’ or unlagged. New style foam tank insulation. Plastic/metal flues, conduit & ducting. Electrics & boiler not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 35 of 76
ITEM No. 24
Location: Cellar Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & new style roofing felt ceiling. Concrete floor. No skirting. Timber beams. Timber door & window frames. Timber/plaster/metal panels & boxing. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit & ducting. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 36 of 76
ITEM No. 25
Location: Corridor Toilet Description: Floor Tiles
Laboratory Ref: PR13/0006/B12 Product Type: Composite
Asbestos Detected: No Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 37 of 76
ITEM No. 26
Location: Corridor Toilet Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Tiled concrete floor. Timber skirting. Timber door frame. Timber/plaster panels & boxing. Pipework ‘Armaflex’ or unlagged. Plastic conduit. Timber toilet seat & ceramic cistern. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 38 of 76
ITEM No. 27
Location: Bar Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor under new style linoleum. Timber skirting. New style step nosings. Timber door & hatch frames. Timber/plaster panels & boxing. Pipework ‘Armaflex’ or unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 39 of 76
ITEM No. 28
Location: Upper Bar Description: Sink Pads
Laboratory Ref: PR13/0006/B13 Product Type: Composite
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Easy Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 40 of 76
ITEM No. 29
Location: Upper Bar Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor under new style linoleum. Timber skirting. Timber door & hatch frames. Timber/plaster panels & boxing. Pipework ‘Armaflex’ or unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 41 of 76
ITEM No. 30
Location: Upper Bar Seating Area Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster/timber walls & ceiling. Timber floor. Timber skirting & beams. Timber/UPVC door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live). Heaters behind seats not inspected.
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 42 of 76
ITEM No. 31
Location: Entrance Lobby Description: Grey Floor Tiles Under Carpet
Laboratory Ref: Similar To PR13/0006/B05
Product Type: Composite Asbestos Detected: N/A
Asbestos Type: Presumed Chrysotile Accessibility: Easy
Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: N/A
Product Type: 1
Extent of Damage: 0
Surface Treatment: 0
Recommendations: Either label & manage or remove. All works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 2
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 43 of 76
ITEM No. 32
Location: Entrance Lobby Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster/timber walls & ceiling. Tiled concrete floor. Timber steps with new style nosings. Timber skirting & beams. Timber door & window frames. Timber/plaster panels & boxing. Pipework unlagged. Plastic conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 44 of 76
ITEM No. 33
Location: 1st Floor Side Roof Space Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & new style roofing felt ceiling. Plaster to ceiling below. Timber beams. Timber/plaster panels & boxing. Glass fibre loft insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live). No access to opposite side (full).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 45 of 76
ITEM No. 34
Location: 1st Floor Storage 1 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & new style roofing felt ceiling. Timber floor. Timber beams. Timber/plaster panels & boxing. Timber door frame. Glass fibre loft insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 46 of 76
ITEM No. 35
Location: 1st Floor Storage 2 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber door frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 47 of 76
ITEM No. 36
Location: 1st Floor Storage 3 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber/UPVC door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 48 of 76
ITEM No. 37
Location: 1st Floor Storage 4 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber door frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 49 of 76
ITEM No. 38
Location: 1st Floor Storage 5 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber/UPVC door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 50 of 76
ITEM No. 39
Location: 1st Floor Secretary’s Office Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber/UPVC door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 51 of 76
ITEM No. 40
Location: 1st Floor PSC Training Room Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber skirting. Timber/plaster panels & boxing. Timber/UPVC door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 52 of 76
ITEM No. 41
Location: 1st Floor Maintenance Office Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. ‘Polyripple’ type ceiling coating. Timber skirting. Timber/plaster panels & boxing. Timber/UPVC door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 53 of 76
ITEM No. 42
Location: 1st Floor Landing/Stairwell Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Timber floor. Timber staircase. Timber skirting. Timber/plaster panels & boxing. Timber door & window frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 54 of 76
ITEM No. 43
Location: 1st Floor Main Roof Space Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls. Plaster to ceiling below. Close boarded. Timber framework. Timber hatch & frame. Timber/plaster panels & boxing. Glass fibre lagged tanks. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 55 of 76
ITEM No. 44
Location: Area Behind External Stores 1-3 Description: Cement Debris
Laboratory Ref: PR13/0006/B16 Product Type: Cement
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Cement (AC).
Product Type: 1
Extent of Damage: 3
Surface Treatment: 1
Recommendations: Remove. Any works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 6
Potential To Release Fibres: LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 56 of 76
ITEM No. 45
Location: Area Behind External Stores 1-3 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: AC Debris. Brick/block/timber walls & ceiling. Shingle floor. Timber beams. Timber panels & boxing. Timber door frames. Glass fibre insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 57 of 76
ITEM No. 46
Location: External Store 1 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/timber walls & ceiling. Shingle floor. Timber beams. Timber panels & boxing. Timber door frames. Glass fibre insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 58 of 76
ITEM No. 47
Location: External Store 2 Description: Ceiling Panels
Laboratory Ref: PR13/0006/B15 Product Type: Insulation Board
Asbestos Detected: Yes Asbestos Type: Amosite
Accessibility: Easy Estimated Amount: 10-50m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Insulation Board (AIB)..
Product Type: 2
Extent of Damage: 1
Surface Treatment: 2
Recommendations: Either, encapsulate, label & manage or remove. Any works must be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 2 Total Score: 7
Potential To Release Fibres: MEDIUM
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 59 of 76
ITEM No. 48
Location: External Store 2 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/AIB walls & ceiling. Shingle floor. Timber beams. Timber panels & boxing. Timber door frames. Glass fibre insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 60 of 76
ITEM No. 49
Location: External Store 3 Description: Ceiling Panels
Laboratory Ref: Similar To PR13/0006/B15
Product Type: Insulation Board Asbestos Detected: N/A
Asbestos Type: Presumed Amosite Accessibility: Easy
Estimated Amount: 10-50m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Insulation Board (AIB)..
Product Type: 2
Extent of Damage: 1
Surface Treatment: 2
Recommendations: Either, encapsulate, label & manage or remove. Any works must be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 2 Total Score: 7
Potential To Release Fibres: MEDIUM
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 61 of 76
ITEM No. 50
Location: External Store 3 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/AIB walls & ceiling. Shingle floor. Timber beams. Timber panels & boxing. Timber door frames. Glass fibre insulation. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 62 of 76
ITEM No. 51
Location: External Description: Roof Undercloaking
Laboratory Ref: PR13/0006/B14 Product Type: Cement
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Cement (AC).
Product Type: 1
Extent of Damage: 3
Surface Treatment: 1
Recommendations: Remove. Any works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 6
Potential To Release Fibres: LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 63 of 76
ITEM No. 52
Location: External Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Traditional roof tiles & new style roofing felt. Soffits & fascias appear to be Timber/plastic. AC roof undercloaking. Plastic/metal rainwater goods. Pipework glass fibre/‘Armaflex’ or unlagged. Plastic/metal conduit & ducting. Plastic/metal flues. Electrics & plant not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 64 of 76
ITEM No. 53
Location: External Shed Adjacent Stores 1-3 Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Timber construction. Concrete floor. No apparent conduit or pipework.
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 65 of 76
ITEM No. 54
Location: External Band Stand Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Timber construction. Concrete/timber floor. Plastic roof. No apparent conduit or pipework.
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 66 of 76
ITEM No. 55
Location: External Toilet Description: Roof Tiles
Laboratory Ref: PR13/0006/B18 Product Type: Cement
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: <10m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Cement (AC).
Product Type: 1
Extent of Damage: 1
Surface Treatment: 1
Recommendations: Either label & manage or remove. Any works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 4
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 67 of 76
ITEM No. 56
Location: External Toilet Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Quarry tiled floor. Quarry tiled skirting. Timber panels & boxing. Timber door & window frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Plastic toilet seat & ceramic cistern. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 68 of 76
ITEM No. 57
Location: External Acetylene Store Description: Roof/Ceiling Sheets
Laboratory Ref: PR13/0006/B17 Product Type: Cement
Asbestos Detected: Yes Asbestos Type: Chrysotile
Accessibility: Medium Estimated Amount: 10-50m2 MATERIAL RISK ASSESSMENT
Additional information: Asbestos Cement (AC).
Product Type: 1
Extent of Damage: 1
Surface Treatment: 1
Recommendations: Either label & manage or remove. Any works should be carried out by a licensed contractor and must be notified to the HSE prior to the works commencing.
Asbestos Type: 1 Total Score: 4
Potential To Release Fibres: VERY LOW
Risks: Abrading surface for decorating. Damage from maintenance works or use of the area.
Report Ref: PR13/0006 Page 69 of 76
ITEM No. 58
Location: External Acetylene Store Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster/AC walls & ceiling. Concrete floor. Timber panels & boxing. Timber door & window frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 70 of 76
ITEM No. 59
Location: External Maintenance Workshop Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Concrete floor. Timber beams. Timber panels & boxing. Timber door frames. Pipework unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 71 of 76
ITEM No. 60
Location: External Anglers Nest Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster part-tiled walls & ceiling. Concrete floor. Timber beams & skirting. Timber panels & boxing. Timber door & window frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 72 of 76
ITEM No. 61
Location: External Scout Hut Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & plastic ceiling. Concrete floor. Timber/plaster panels & boxing. Timber door frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 73 of 76
ITEM No. 62
Location: External Garage Under Starters’ Box Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A MATERIAL RISK ASSESSMENT
Additional information: Brick/block/plaster walls & ceiling. Concrete floor. Timber/plaster panels & boxing. Metal door frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 74 of 76
ITEM No. 63
Location: External Starters’ Box Description: General
Laboratory Ref: Not Sampled Product Type: N/A
Asbestos Detected: N/A Asbestos Type: N/A
Accessibility: N/A Estimated Amount: N/A
MATERIAL RISK ASSESSMENT
Additional information: Timber construction. Concrete floor. Timber panels & boxing. New style roofing felt. Timber door & window frames. Pipework ‘Armaflex’ or unlagged. Plastic/metal conduit. Electrics not inspected (live).
Product Type: N/A
Extent of Damage: N/A
Surface Treatment: N/A
Recommendations: N/A
Asbestos Type: N/A Total Score: N/A
Potential To Release Fibres: N/A
Risks: N/A
Report Ref: PR13/0006 Page 75 of 76
SECTION 8
CERTIFICATES
Report Ref: PR13/0006 Page 76 of 76
SECTION 9
PLANS
SAMPLE NUMBER ON
PLANS
SEE ITEM NUMBER IN SECTION 6
SAMPLE NUMBER ON
PLANS
SEE ITEM NUMBER IN SECTION 6
Sample 1
Item 2
Sample 10
Item 21
Sample 2
Item 4
Sample 11
Item 22
Sample 3
Item 5
Sample 12
Item 25
Sample 4
Item 7
Sample 13
Item 28
Sample 5
Item 10
Sample 14
Item 51
Sample 6
Item 12
Sample 15
Item 47
Sample 7
Item 13
Sample 16
Item 44
Sample 8
Item 16
Sample 17
Item 57
Sample 9
Item 19
Sample 18
Item 55