ATI K I T CAME UNITED KINGDOM LTD ORCHARD PARK INDUSTRIAL ESTATE TOWN STREET, SANDIACRE, NOTTINGHAM, NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 INTERNET - www.cameuk.com E-MAIL - [email protected] TECHNICAL HELPLINE 0115 921 0430 Installation Instructions for a “Pair” of gates... THE ATI-P KIT CONSISTS OF: 2 X ATI MOTORS 1 X CONTROL PANEL 1 X RADIO FREQUENCY CARD 1 X TUNED ANTENNA 2 X REMOTE CONTROL TRANSMITTERS 1 X PAIR SAFETY BEAMS
Transcript
Page 1: Manual Brazo Came Ati

ATI K I T

CAME UNITED KINGDOM LTDORCHARD PARK INDUSTRIAL ESTATETOWN STREET, SANDIACRE,NOTTINGHAM, NG10 5BP

TEL: 0115 921 0430

FAX: 0115 921 0431

INTERNET - www.cameuk.comE-MAIL - [email protected]

TECHNICALHELPLINE

0115 921 0430

Installation Instructions

for a “Pair” of gates...

THE ATI-P KIT CONSISTS OF:2 X ATI MOTORS1 X CONTROL PANEL1 X RADIO FREQUENCY CARD1 X TUNED ANTENNA2 X REMOTE CONTROL TRANSMITTERS1 X PAIR SAFETY BEAMS

Page 2: Manual Brazo Came Ati

THESE INSTRUCTIONS WILL SHOW YOU HOW TO INSTALLAN ATI GATE KIT TO A PAIR OF GATES.

PLEASE READ THESE INSTRUCTIONS AND DIAGRAMSCAREFULLY BEFORE STARTING ANY WORK.

1

UNDER NO CIRCUMSTANCES SHOULD THIS EQUIPMENT BE OPERATED UNLESS FITTED TO A GATE.

FAILURE TO COMPLY WILL INVALIDATE THE GUARANTEE.

I N T R O D U C T I O N

Page 3: Manual Brazo Came Ati

INSTALLATION INSTRUCTIONSCONTENTS

1) Stage 1:- Civil & Mechanical Section Page

1.1 BASIC HINGE GEOMETRY 31.2 BASIC CABLE LAYOUT 41.3 LOW VOLTAGE CABLE LAYOUT 51.4 ATTACHING BRACKETS 51.5 ATTACHING THE REAR BRACKET 61.6 ATTACHING THE FRONT BRACKET 7

2) Stage 2:- Wiring & Electrical

2.1 FITTING THE CONTROL PANEL IN THE CASING 92.2 GAINING ACCESS TO MOTORS 102.3 INSTALLING THE MOTORS 112.4 ADJUSTING OPEN/STOP LIMIT SWITCH 112.5 WIRING THE MOTORS 132.6 WIRING THE SAFETY PHOTOCELLS 142.7 INSERTING THE FREQUENCY CARD 142.8 WIRING IN THE TUNED ANTENNA 152.9 CODING THE REMOTE CONTROLS 152.10 POWERING UP THE CONTROL PANEL 15

3) Stage 3:- Commissioning the Control Panel

3.1 INITIAL WIRING & CONTROL PANEL SETUP 173.2 OPENING & CLOSING THE GATES 183.3 CONTROL PANEL ADJUSTMENTS 193.4 AUTOMATIC CLOSE & SAFETY PHOTOCELLS 203.5 PROGRAMMING THE REMOTE CONTROLS TO THE

CONTROL PANEL 21

4) Troubleshooting Guide 23

5) Technical Information

5.1 TECHNICAL SPECIFICATIONS 255.2 MOTOR TORQUE SETTINGS 265.3 ZA4 CONTROL PANEL DESCRIPTION 275.4 ZA4 WIRING DIAGRAM 295.5 CONTROL PANEL ADJUSTMENTS 305.6 ELECTRICAL CONNECTIONS 31

7) Contact Information

“TIME MARCHES ON BUT CAME AUTOMATION EQUIPMENT STANDS THE TEST OF TIME...”

Page 4: Manual Brazo Came Ati

3

STAGE 1CIVIL & MECHANICAL SECTION

1.1- Basic Hinge Geometry

BEFORE BEGINNING YOUR INSTALLATION OF YOUR ATI SYSTEM, CHECK THEFOLLOWING:

* YOUR GATE PIERS OR POSTS ARE SUFFICIENTLY STRONG ENOUGHTO SUPPORT THE GATES AND OPERATORS AND THE GATES SWINGFREELY AND THERE IS NO FRICTION BETWEEN THE MOVING PARTS.

* MEASUREMENT C MUST NOT BE GREATER THAN THE VALUE SHOWNBELOW. IF THIS IS THE CASE, IT IS NECESSARY TO MODIFY THEPILLAR SO THAT THIS MEASUREMENT CORRESPONDS.

Fig 1

C

PILLAR PILLAR

C

CENTRE STOP

HINGE HINGE

* ENSURE THAT A GATE CENTRE STOP IS SECURELY CONCRETED INTO THEGROUND AND AS A GUIDE, THE CENTRE STOP SHOULD NOT PROTRUDE OUTOF THE GROUND NO MORE THAN 65mm, IF IT IS MUCH HIGHER IT MAYCATCH ON THE UNDER-SIDE OF A CAR.

Dimension C must be no greater than 120mm for 90 opening andno greater than 70mm for a 130 opening.

Page 5: Manual Brazo Came Ati

1.2 - Basic Cable Layout

THIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FORA PAIR OF MOTORS.

THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE ANDPROTECTED IN ACCORDANCE WITH THE 16TH EDITION ELECTRICALREGULATIONS. THE SUPPLY SHOULD BE RATED AT A MINIMUM OF 6 AMPS.WHEN INSTALLING WIRES OUTDOORS THE CABLE APPROACH TO ALLDEVICES MUST BE FROM BELOW TO CREATE A “DRIP-LOOP” AND THEREBYAVOID UNNECCESSARY WATER INGRESS.

4

Fig 2

WHEN INSTALLING LOW VOLTAGE CABLE AROUND THE GATEWAY IT ISADVISED TO PUT ALL LOW VOLTAGE CABLE IN EITHER DUCTING ORALKATHENE PIPING. ALL CABLE JOINTING SHOULD BE CARRIED OUTABOVE GROUND.

CONTROL PANELHOUSING

240V A.C 3 CORE1.5mm SWA

4 CORE1.5mm FLEX

JOINT BOX

Page 6: Manual Brazo Came Ati

5

1.3 - Low Voltage Cable Layout

ALL CAME ACCESSORIES CAN BE WIRED 0.2m STRANDED CABLE (BUGLARALARM TYPE). THE TUNED ANTENNA SHOULD BE WIRED WITH COAXIALCABLE (RG59).

WELD THE 9 HOLE BRACKET TO THE FIXING PLATE THEN SECURLEYATTACH THE FIXING BRACKET TO THE PIER OR POST, OBSERVEMEASUREMENT A AND B BETWEEN THE HINGE PIN AND THE CENTRALHOLE IN THE BRACKET.

1.4 - Attaching Brackets

Fig 3

TUNEDANTENNA

COAXIALCABLE

DOC E SAFETYBEAMS

8 CORE 0.2mm STRANDEDCABLE TO ALL SAFETY BEAMS

Fig 4

A

REAR BRACKET

FIXING PLATE

B

Opening A Bmm mm

90

130

200

200

200

140

Page 7: Manual Brazo Came Ati

6

THE REAR BRACKET IS EQUIPPED WITH ADDITIONAL HOLES TO MAKEINSTALLATION OF THE GATE MOTOR EASIER, OR TO CHANGE THEOPENING ANGLE OF THE GATE. THE REAR BRACKET CAN BE LENGHENEDOR SHORTENED TO SUIT THE INDIVIDUAL INSTALLATION SITE AND THEPOSITION OF THE GATES (WITH RESPECT TO THE PILLARS).

N.B IF MEASUREMENT B IS INCREASED, THE ANGLE OF APETURE ISREDUCED. THIS THEREFORE REDUCES THE PERIPHERAL SPEEDAND INCREASES THE THRUST EXERTED BY THE MOTOR ON THEGATE. IF MEASUREMENT A IS INCREASED, THE ANGLE OFAPERTURE IS INCREASED. THIS THEREFORE INCREASES THEPERIPHERAL SPEED AND REDUCES THE THRUST EXERTED BY THEMOTOR ON THE GATE.

WHEN THE REAR BRACKET IS SECURELY ATTACHED TO THE PIER OR POST,INSERT THE BUSH INTO THE DESIRED HOLE AND ATTACH THE REAR JOINTARM, LUBRICATING WITH A NEUTRAL GREASE.

Fig 5

MB

REAR JOINT

M8 X 38

BUSHING

1.5 - Attaching the Rear Bracket

Page 8: Manual Brazo Came Ati

7

WITH THE GATE IN THE FULLY CLOSED POSITION WELD THE FRONTBRACKET TO THE FIXING PLATE THEN ATTACH IT TO THE GATE. THEANCHOR PLATE MUST BE HORIZONTALLY ALIGNED WITH THE REARBRACKET MOUNTED ON THE PEIR OR POST ENSURING DIMENSION ISOBSERVED.

N.B WHEN INSTALLING THE UNIT ON SPECIAL FRAMES, IT MAY BENECCESSARY TO FIT ADDITIONAL SPACERS WITH A MINIMUMTHICKNESS OF 10mm IN ORDER TO PREVENT CONTACT BETWEENTHE OPERATOR AND THE GATE WING.

THICKNESSMIN 10mm

FIXINGPLATE

LEVEL THE BRACKET

FRONTBRACKETE=880 mm

Fig 6

1.6 - Attaching the Front Bracket

Page 9: Manual Brazo Came Ati

BEFORE STARTING STAGE 2 - Wiring & ElectricalPLEASE CHECK THAT YOU HAVE CORRECTLY:

Ref Page

1. PREPARED THE CABLING CORRECTLY 1.2 4

2. CORRECTLY ATTACHED THE BRACKETS 1.4 5

NOW STAGE 1 IS FULLY COMPLETED YOU ARE READY TOBEGIN STAGE 2 OF YOUR ATI AUTOMATION KIT

INSTALLATION

END OF INSTALLATIONSTAGE 1

8

Page 10: Manual Brazo Came Ati

9

STAGE 2 - WIRING & ELECTRICAL

2.1 - Fitting the Control Panel in the Casing

Securely fasten the control panel PCB to thecasing with the screws supplied.

Plug the green connector from the transformer tothe PCB ensuring that it connects the correct way.

NB FROG Series Motors: connect the black wirescoming out of the board to one capacitor and thered wires to the other.

Screws

Screw positioning holes

Green connector point

Fastening screws

Page 11: Manual Brazo Came Ati

10

2.2 - Gaining Access to the Motors

TO GAIN ACCESS TO THE MOTOR TERMINALS AND WORM DRIVE FIRSTREMOVE THE COVERS. FIRST REMOVE THE SCREWS FROM THE TOPCOVER. THEN REMOVE THE TWO SCREWS THAT SECURE THE WORMDRIVE COVER.

Fig 7

Fig 8

CASING

COVER

Page 12: Manual Brazo Came Ati

WITH THE COVERS REMOVED INSTALL THE MOTOR ON THE TWOBRACKETS AND SECURE THE MOTOR WITH THE NUTS AND BOLTSPROVIDED.

Fig 9

M8 X 50M8 X 10

WORM-GEAR

M8 LOCKNUT

2.4 - Adjusting the Open Stop Microswitch

MANUALLY RELEASE THE REDUCTION GEAR BY INSERTING THE RELEASEKEY AND TURNING IT 180.

180°

Fig 10

11

2.3 - Installing the Motors

Page 13: Manual Brazo Came Ati

12

MOVE THE GATE TO THE DESIRED OPEN POSITION. LOOSEN THE SCREWSWHICH HOLD THE MICROSWITCH IN POSITION. SLIDE THE MICROSWITCHON THE SUPPORT PLATE UNTIL THE MICROSWITCH IS TRIPPED. THENTIGHTEN THE SCREWS TO ANCHOR THE MICROSWITCH IN POSITION.

FIXING SCREW

SCREWNUT

WORM-GEAR

SUPPORT PLATEMICROSWITCH

MICROSWITCH

Fig 11

Page 14: Manual Brazo Came Ati

13

U V W X Y E E3

U V W W X Y

MOTOR 1 MOTOR 2

MOTOREARTH

MOTOREARTH

2.5 - Wiring the Motors

ENSURE BOTH MOTORS ARE ADEQUATELY EARTHED.

Fig 12

Page 15: Manual Brazo Came Ati

ZA4

2.6 - Wiring in the Safety Photocells

SAFETY BEAMS SHOULD BE FITTED APPROXIMATELY15 INCHES FROM GROUND LEVEL

CONTROL PANEL

10 11 2 C1

CNC

RX

1011

TX

1011

Fig 13

SAFETYBEAM

RECEIVER

SAFETYBEAM

TRANSMITTER

IF FITTING A SECOND ARC LINE SET OF SAFETY BEAMS THEN C & NC MUST BE WIRED IN “SERIES”

2.7 - Inserting the Radio Frequency Card

INSERT THE RADIO FREQUENCYCARD INTO THE SMALL SOCKETON THE CONTROL PANEL(ENSURE THAT THE POWER ISTURNED OFF TO THE CONTROLPANEL BEFORE INSERTING THEFREQUENCY CARD)

ANTENNAWIRINGPOINT

Fig 14

NC

C

14

Page 16: Manual Brazo Came Ati

2.8 - Wiring in the Tuned Antenna

2.9 - Coding the Remote Controls

1. REMOVE THE BATTERY COVER & CASING OF THE REMOTE CONTROLHANDSET TO REVEAL THE DIAGRAM BELOW

2.10 - Powering up the Control Panel

CONNECT PROTECTED MAINS POWER TO TERMINALS L1 + L2 IN THECONTROL PANEL (L2 BEING LIVE!). ENSURE THAT THE CONTROL PANEL

IS ADEQUATELY EARTHED.

ANTENNAWIRINGPOINT

Fig 15

Bat

Bat

tery

12V

ON

1 2

3

4 5

6

7 8

9

10

8

9 10

ON OFF

Bt

Bat

t1

2. SET THE BANK OF

DIPSWITCHES ONALL REMOTES TOEXACTLY THE SAMECODE OF YOURCHOICE.

3. UNLESS PROGRAMMING FOR GATES AND

GARAGE DOORS TO OPEN BY REMOTECONTROL FROM THE SAME HANDSET ENSURETHAT THE JUMPER STRAPS SHOWN HERE AREIN THE SAME POSITIONS ON ALL REMOTES

Fig 16

15

Page 17: Manual Brazo Came Ati

END OF INSTALLATIONSTAGE 2

BEFORE STARTING STAGE 3 -Commissioning the Control Panel

PLEASE CHECK THAT YOU HAVE CORRECTLY:

Ref Page

1. GAINED ACCESS TO MOTORS 2.1 9

2. INSTALLED MOTORS 2.2 10

3. ADJUSTED OPEN/STOP LIMIT SWITCH 2.3 10

4. WIRED THE MOTORS 2.4 12

5. WIRED THE SAFETY PHOTOCELLS 2.5 13

6. INSERTING THE FREQUENCY CARD 2.6 13

7. WIRED THE TUNED ANTENNA 2.7 14

8. CODED THE REMOTE CONTROLS 2.8 14

9. POWERED UP THE CONTROL PANEL 2.9 14

NOW STAGE 2 IS FULLY COMPLETED YOU ARE READY TOBEGIN STAGE 3 OF YOUR ATI AUTOMATION KIT

INSTALLATION

16

Page 18: Manual Brazo Came Ati

STAGE 3COMMISSIONING THE CONTROL PANEL

3.1 - Initial Wiring & Control Panel Setup

1. CONNECT POWER TERMINALS L1 - L2AND A SUITABLE EARTH (L2 BEING LIVE!)

2. SELECT THE MOTOR POWER SETTING ONTHE TRANSFORMER TO LEVEL 1 FORCOMMISSIONING

Fig 17

3. SELECT DIPSWITCHES 1 & 2 OFF FORCOMMISSIONING

4. ENSURE HARD WIRE LINK IS FITTEDBETWEEN TERMINALS 1 & 2 AND2 & C1

ON

OFF

1 2 3 4 5 6 7 8 9 10

Fig 18

Fig 1910 11 S 1 2 3 3P 4 5 7 2 C1 CX B1 B2

17

Page 19: Manual Brazo Came Ati

3.2 - Opening & Closing the Gates

2. ONCE YOU HAVE PROVED THEMOTOR DIRECTION USETERMINALS 2 & 7 TO OPEN ANDCLOSE THE GATES WITH ATRAILING WIRE ONCE AGAIN INTOTERMINAL 2, MOMENTARILYTOUCHING TERMINAL 7.

18

1. MOMENTARILY PULSE TERMINALS2 & 3 WITH A PIECE OF WIRETRAILING FROM TERMINAL 2 ANDMOMENTARILY TOUCHINGTERMINAL 3.

THE GATES SHOULD START TOOPEN. IF THEY START TO CLOSETURN THE POWER OFF TO THECONTROL PANEL AND CHANGEAROUND EITHER U-V (MOTOR 1)OR X-Y (MOTOR 2) TO CHANGETHE MOTOR DIRECTION.

Fig 20

Fig 21

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

Page 20: Manual Brazo Came Ati

TRIMMER TR2M

3.3 - Control Panel Adjustments

TRIMMER TL

1. TO DELAY ONE GATE LEAF, ADJUST POTENIOMETER TR2M TO DELAYTHE CLOSING OF GATE NO. 2 IN THE CLOSING CYCLE

2. TO SET THE TOTAL RUNNING TIME OF THE MOTORS, ADJUSTPOTENIOMETER TL TO ALLOW THE MOTORS TO RUN FOR A FURTHER5-7 SECONDS AFTER THE MOVEMENT CYCLE HAS BEEN COMPLETED(I.E FULLY OPEN OR FULLY CLOSED)

3. CHECK THE SENSITIVITY OF THE GATESBY TRYING TO PHYSICALLY STOP THEGATE AND ADJUST THE POWERSETTINGS ON THE TRANSFORMERACCORDINGLY. IF MORE POWER ISNEEDED FOR HEAVIER GATES THENSWITCH OFF POWER AND MOVETRANSFORMER WIRE UP TO SETTING 2.FOR RECHECKING SENSITIVITY, REPEATPROCESS UP TO 3 OR 4 IF EVEN MOREPOWER IS NEEDED.

Fig 22

Fig 23

Fig 24

19

Page 21: Manual Brazo Came Ati

10 11 1 2 3 5 7 C1

10 11 C NC

3.4 - Automatic Close & Activating Safety Photocells

FULLY ANTI-CLOCKWISE WILL APPROX. AUTOMATICALLY CLOSE THE GATESAFTER 10 SECONDS AND FULLY CLOCKWISE WILL APPROX. CLOSE THEGATES AFTER 80 SECONDS. A SENSIBLE SETTING IS ABOUT HALFWAY(I.E 6 O’CLOCK POSITION) WHICH WILL AUTOMATICALLY CLOSE THEGATES AFTER APPROX. 30 SECONDS.

6 O’CLOCK

TRIMMERTCA

1. TO SELECT AUTOMATIC CLOSING,SELECT DIPSWITCH 2 ON.

SET THE AUTOMATIC CLOSING TIME BY ADJUSTING POTENTIOMETER TCA

Fig 25

Fig 26

Fig 27

ON

OFF1

1

2. FOR RE-OPENING DURING CLOSING.REMOVE HARD WIRE LINK BETWEEN2 & C1 AND INSERT SAFETY BEAMWIRES AS SHOWN.

20

Page 22: Manual Brazo Came Ati

3.5 - Programming the Remote Controlsto the Control Panel

To use the remote control system, proceed as follows:

A) Turn power OFF and insert AF radio frequency board then turnpower back on

B) Code the transmitter. See the relevant instruction sheet(See Fig 11)

C) To store the code on the circuit board Proceed as follows:

Press and hold down the programming button on the radio receivercard (the signal LED will start to flash)

At the same time transmit on the top button of your remotecontrol; keep both the top button and the yellow receiver buttonpressed until the LED stops flashing and remains on constant. Itwill then go out to indicate that the code has been successfullystored.

N.B. If you wish to change the code on your transmitter in the future,simply repeat the procedure above with all the remotes on theinstallation.

WARNING: Disconnect the power supply from the control board beforeinserting OR removing the AF radio-frquency card from thesocket.

21

Page 23: Manual Brazo Came Ati

22

PLEASE CHECK THAT YOU HAVE CORRECTLY:

Ref Page

1. SET POWER SETTING, SET DIPSWITCHES FORCOMMISSIONING, ENSURE WIRE LINKIS FITTED BETWEEN TERMINALS 1 & 2AND 2 & C1 3.1 16

2. SET THE OPENING AND CLOSING TIMESFOR GATES 3.2 17

3. ADJUSTED THE CONTROL PANEL 3.3 18

4. IF REQUIRED, ACTIVATED AUTOMATICCLOSING AND SAFETY PHOTOCELLS 3.4 19

5. PROGRAMMED THE REMOTE TO THECONTROL PANEL 3.5 20

END OF INSTALLATIONSTAGE 3

Page 24: Manual Brazo Came Ati

23

4. TROUBLESHOOTING GUIDEA MULTIMETER WILL BE NEEDED

PROBLEM SOLUTION

GATE WILL NOT RESPONDWHEN GIVEN A COMMAND

1. CHECK POWER SUPPLY TO THECONTROL PANEL.

2. CHECK CONTROL PANEL FUSES.

3. CHECK HARD WIRE LINK FITTEDBETWEEN TERMINALS 1 & 2.

1. CHECK SAFETY BEAMS ARE WIREDCORRECTLY. (IF MORE THAN ONESET OF BEAMS ARE FITTED THEYMUST BE WIRED IN SERIES.)

2. CHECK THAT THERE IS POWERGOING TO THE BEAMS, IF NOTRESTORE POWER.

3. IF SAFETY BEAMS ARE NOT FITTEDENSURE THAT A HARD WIRE LINK ISFITTED BETWEEN TERMINALS 2 & C1

4. REMOVE SAFETY BEAM WIRES 2 &C1 FROM CONTROL PANEL ANDCHECK IF YOU HAVE A NORMALLYCLOSED CIRCUIT COMING FROMTHE BEAMS.

1. MOTOR WIRES ARE WRONG WAYROUND. CHECK AND PROVE MOTORDIRECTION BY MOMENTORIALLYPULSING TERMINALS 2 & 3. THEGATE SHOULD OPEN UP. TURNAUTOMATIC CLOSING OFF (DIPSWITCH 2) UNTIL MOTORDIRECTION HAS BEEN PROVED.

WHEN COMMISSIONINGGATE AUTOMATICALLYOPENS BUT DOES NOTAUTOMATICALLY CLOSE

GATES ARE OPEN BUT WILLNOT CLOSE AND GREEN LED

IS FLASHING

CONTINUED ON NEXT PAGE

Page 25: Manual Brazo Came Ati

24

PROBLEM SOLUTION

1. AF FREQUENCY CARD NOT FITTED TOCONTROL PANEL.

2. REMOTE CONTROL HAS NOT BEENPROGRAMMED INTO THE CONTROLPANEL.

3. REMOTE CONTROL HAS THE WRONGCODE SETTING.

4. “OPERATOR PRESENT” HAS NOT BEENSELECTED TO DEACTIVATE RADIOREMOTE CONTROLS (DIPSWITCH 1).

5. WRONG FREQUENCY CARD FITTEDFOR THE REMOTE CONTROL.

GATES WILL NOT RESPONDTO REMOTE CONTROL

COMMAND

IF THE PROBLEM IS STILL APPARENT CONTACT THE

C A M EC A M E TECHNICAL HELPLINE:

0800 970 6655

THIS INSTALLATION WAS COMPLETED BY:..............................................................................NAME.............................................................................ADDRESS.................................................................................................................................................................................................................................................................................................TEL........................ MOBILE................................

DATE OF INSTALLATION.......................................

Page 26: Manual Brazo Came Ati

88mm933mm

880mm

500mmTravel

126mm

PILLAR

A

HINGE

GATE WINGCLOSED

CENTRESTOP

E

C

B

25

5. TECHNICAL INFORMATION5.1 - Technical Specification

TYPE

130 DEGREES

A mm B mmC Maxmm E mm

A500090 DEGREES 200

OPENING

200 140

200

70

120 880

880

WIDTH OF GATE WING (M) WEIGHT OF GATE WING (KG)

2.00

2.50

3.00

4.00

5.00

1000

800

600

500

400

GEAR PUSHREDUCTIONPOWERNOMINALPOWERWEIGHTVERSION DUTY CAPACITOR

A5000 1.2 11Kg 230V 1.2A 150W 50% 1/36400 10uF400/3000*N

For particularly heavy gates, two motors per leaf can be fitted. In this case theweight indicated for the gate can be doubled.

Page 27: Manual Brazo Came Ati

26

5.2 - Motor Torque Settings

To vary the motor torque, move the indicated spade connector to one of thefour position : 1=min, 4=max.

N.B. It is always best to start from position one and increase the torquesetting as required.

Fig 28

SEE ALSO PAGE 14

Page 28: Manual Brazo Came Ati

27

5.3 - ZA4 Control Panel Description

Description of Control Panel:

Micro-processor controlled electrical cabinet powered by 230V (a/c) at50-60Hz, single phase. Designed for control of CAME (ATI/FERNI/FROG), forhinged gates, hinged industrial doors. Designed and built entirely by CAME tomeet UNI8612 safety standards at an IP 54 level of protection. Housing made ofABS is equipped with vents to provide internal air circulation. Guaranteed for 3years, unless tampered with. This control panel is powered 230V a.c acrossterminals L1 and L2, and is protected by a 5A fuse on the main power line.Control systems are powered by low voltage and protected by a 2A fuse. Theaccessories total wattage (24V) must not exceed 20W.

The Control Panel and Motors should be suitably Earthed

Safety:

SAFETY BEAMS CAN BE CONNECTED TO OBTAIN:

Re-Opening: During closing (2-C1), if the beam is broken while the gate isclosing, they will reverse the direction of movement until the gate iscompletely open and will stay open until the obstacle is removed.

Total Stop: (1-2) Creates immediate stop of gate movement without automaticclosing: (a pushbutton or radio remote control must be

actuated to resume movement).

N.B IF A NORMALLY CLOSED SAFETY CIRCUIT(2-C1, 1-2) IS OPENED, THE L.E.D WILLFLASH TO INDICATE THE FACT THAT THE BEAM ISBROKEN.

Accessories that can be Connected to this Unit:

“Gate in Motion” Lamp: The lamp that lights the manoeuvering zone: it remainslit from the the moment the gate begins to open untilthey are completely closed (including the time requiredfor the automatic closure). When automatic closure isnot enabled, the lamp remains lit only duringmovement (E-E3).

Page 29: Manual Brazo Came Ati

28

1 CONTROL PANEL1 FREQUENCY CARD

2 ATI MOTORS

TUNED ANTENNA2 REMOTE CONTROLTRANSMITTERS

1 PAIR SAFETYBEAMS

Fig 29

Other functions available:

Automatic closing: The automatic closing timer is automatically activated at theend of the opening cycle. The pre-set, adjustable automaticclosing time is automatically interrupted by the activation ofany safety system, and is deactivated after a STOPcommand or in case of power failure.

“Operator present” function:Gate operates only when the pushbutton is held down (theradio control system is deactivated)

Page 30: Manual Brazo Came Ati

5.4 - ZA4 Wiring Diagram

Terminals 1 and 2, 2 and C1 are normally closed circuits and ifthey are not used they must be linked

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

Co-axial cable

230V A/C

M1

Single-Phase motor

Single-Phase motor with leaf delayon closing cycle

M2

11 TX

10

Safety beams which are connected to obtain Re-openingDuring the closing cycle

RX 11

10

C

NC

29

Page 31: Manual Brazo Came Ati

30

ZA4

5.5 - Control Panel Adjustments

Fig 25

Trimmer T.L. - Adjustment of operating time from a minimum of 0 seconds to amaximum of 120 seconds N.B. it is advised to let the motors run on for between 6 and 8seconds after the last gate has fully close.

Trimmer T.C.A - Adjustment of automatic closing time from a minimum of 1 to amaximum of 120 seconds.

Trimmer T.R.2.M - Partial opening time adjustment and delay in closing of the secondmotor leaf delay from a minimum of 0 seconds to a maximum of 20 seconds.

T.L T.C.A T.R.2.M

TRIMMERSADJUSTMENT

Page 32: Manual Brazo Came Ati

31

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

L1

L2

UWV

XWY

W

E1

10

5

10

11

1

2

2

3

2

7

2

C1

5.6 - Electrical Connections

24V (A.C) Output power supply to accessories (max 20W)

Contact (N.C) for re-opening during closing

Antenna connection

Power supply for control panel

Connection for motor one (delay in opening)

Connection for motor two (delay on closing)

230V (A.C) 25W max output in motion (e.g. flashing light)

“Gate Open” signal light (24V 3W max)

Stop button (N.C)

Open only button (N.O)

Contact for radio and or pushbutton control for open-close(N.O)

Page 33: Manual Brazo Came Ati

Notes

Page 34: Manual Brazo Came Ati

Notes

Page 35: Manual Brazo Came Ati

Notes

Page 36: Manual Brazo Came Ati

6. CONTACT INFORMATION

THIS INSTALLATION WAS COMPLETED BY:..............................................................................NAME.............................................................................ADDRESS.................................................................................................................................................................................................................................................................................................TEL........................ MOBILE................................

DATE OF INSTALLATION.......................................

CAME UNITED KINGDOM LTD

UNIT 3ORCHARD PARK INDUSTRIAL ESTATE

TOWN STREET, SANDIACRE, NOTTINGHAM NG10 5BP

TEL: 0115 921 0430FAX: 0115 921 0431

INTERNET : www.cameuk.comE-MAIL: [email protected]


Recommended