8
INSTALLATION MANUAL TWINTILE
Transcript
  • INSTALLATION MANUAL TWINTILE

  • Length of Tile

    1305 mm

    Length of Cover

    1260 mm

    Width of Cover

    321 mm

    Minimum Pitch

    15° (27 %)

    QUBE / QUBE ACOUSTIC

    Length of Tile

    1470 mm

    Length of Cover

    1400 mm

    Width of Cover

    367 mm

    Minimum Pitch

    15° (27 %)

    TWIN ACOUSTIC

    D

    D

    D

    D

    D

    STORAGEIf stored outside, it should be kept in a sheltered place and a well-sealed waterproof cover must be placed over the TWINTILE roofing tiles and accessories to keep them dry and prevent damage.

    NON-STANDARD ELEMENTS When installing non-standard elements or gutters above the level of the roof, it is strongly recommended that materials that could cause corrosion (e.g. Cu, stainless steel...) are NOT used.

    ROOF TRAFFICWhen moving around the roof, avoid avoid buckling the tiles by placing weight on the balls of the feet, directly over the batten, in the pans of tiles.

    CUTTING WITH A SAWWhen cutting tiles with a metal cutting saw (which has been approved by the producer), special (tipped) metal cutting blades should be used. Cutting should be performed with the coated surface facing downwards to reduce the amount of swarf adhering to the coating. Failure to do so will result in rust stains on the tile surface.

    WET SURFACEFor safty reasons is not recommended to walk or work on the roof when it is wet.

    BATTENSThe recommended counter batten dimension is 50 x 80 mm. The minimum counter batten height is 25 mm.

    Tile batten size is 40 x 50 mm (distance between rafters less then 900 mm).

    LOCAL STANDARDSIt is strongly recommended that local building standards and regulations are always followed and fully complied with.

    HANDLINGCare should be taken when handling the tiles to avoid damage to the surface. If minor damage does occur, the finishing kit should be used to repair it.

    Type of Profile Batten Spacing – D

    QUBE / QUBE ACOUSTIC 321 mm

    TWIN ACOUSTIC 367 mm

  • INSTALLATION DETAILS

    EAVE

    S FL

    ASH

    ING

    INTE

    RLO

    CKI

    NG

    O

    F TH

    E TI

    LES

    TILE

    LAY

    ING

    NAI

    L PO

    SITI

    ON

    ING

    11 12 13 1 38 2

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay

    11 Sloping base 12 Mesh 13 Eaves Guard Flashing

    1

    2

    34

    98

    7

    6

    5

    10

  • RID

    GE

    (BAR

    ELLS

    )H

    IP

    (SPA

    CER

    S)RI

    DG

    E (L

    ON

    G V

    RID

    GE)

    HIP

    (R

    IDG

    E RO

    LL)

    1 2 3 4 5 76 8 918

    1 2 3 4 5 76 8 918

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 4 Angle Trim 5 Ridge Batten

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 4 Long V Ridge 5 Ridge Batten

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 4 Angle Trim 5 Ridge Batten

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 4 Angle Trim 5 Ridge Batten

    6 Spacer 7 Ridge Bracket 8 Underlay 9 Rafter 18 Thinner Support Batten

    6 Spacer 7 Ridge Bracket 8 Underlay 9 Rafter 18 Thinner Support Batten

    6 Spacer 8 Underlay 9 Rafter 14 Ventilation Space

    6 Ridge Roll 8 Underlay 9 Rafter 14 Ventilation Space

    2 4 5 6 5 8 9 1431

    2 4 5 6 5 8 9 1431

  • GAB

    LE

    (SC

    RIBE

    D R

    IDG

    E EL

    EMEN

    T)W

    ALL

    FLAS

    HIN

    GG

    ABLE

    (BAR

    GE

    FLAS

    HIN

    G W

    ITH

    WAT

    ER C

    HAN

    NEL

    )VA

    LLEY

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay

    9 Rafter14 Ventilation Space15 Scribed Flashing17 Barge Board

    9 Rafter14 Ventilation Space16 Long Barge Board Cover Countersunk17 Barge Board

    17 15 3 9 14 8 1 2

    17 16 3 9 14 8 1 2

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter14 Ventilation Space21 Flashing with Water Channel 22 Side Flashing 23 Warmth Insulation

    1

    2

    1 2

    8

    9

    14 3 21 24 25 2322

    24 Side Wall Starter Flashing25 Sealant

    1 QUBE / TWIN 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter10 Valley14 Ventilation Space26 Valley Sealing Foam27 Support Board

    3 26 27 10 8 9 14

  • ACCESSORIES

    Round ridgeLength of cover: 380 mm• TWIN ACOUSTIC

    Long V ridgeLength of cover: 1250 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Angle trimLength of cover: 380 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Short side (Left or Right) Length of cover: 367 mm• TWIN ACOUSTIC

    Mono-pitched ridge Length of cover: 1250 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Long barge board cover countersunkLength of cover: 1250 mm• QUBE ACOUSTIC • QUBE

    CH

    IMN

    EY F

    LASH

    ING

    RO

    OF

    WIN

    DO

    W

    1 Tile 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter25 Sealant27 Chimney Flashing28 Support Board

    1 Tile 2 Tile Batten 3 Ventilation Space Batten 8 Underlay 9 Rafter 28 Support Board 33 Roof Window Flashing 35 Roof Window 36 Support Batten

    1

    1

    2

    2

    2

    3

    3 8

    2 cm

    3335

    36

    9

    827

    27 28

    25 9

    1

    33351 2 36

  • Small sub-ridgeLength of cover: 1250 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Large sub-ridgeLength of cover: 1300 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Mini sub-ridgeLength of cover: 1250 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Side wall flashing scribed (Left or Right)Length of cover: 1101 mm• TWIN ACOUSTIC

    Flashing Left or RightLength of cover: 1101 mm• TWIN ACOUSTIC

    Flashing Left or RightLength of cover: 1284 mm• QUBE ACOUSTIC • QUBE

    Sloping base/mountingLength of cover: 1250 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Valley gutterLength of cover: 1300 mm• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Transparent tileCoverage: 0,35 m2

    • TWIN ACOUSTIC

    Roof vent flange plumbingPipe cross-section: 150 x 150 mm• QUBE ACOUSTIC • QUBE

    Snow-stopperSteel, powder coated• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Nails on a reel325 pcs/pack (2,8 x 50 mm)• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Touch-up pen12 ml• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

    Roof ventilation elementFree ventilation area: 75 cm2• TWIN ACOUSTIC • QUBE ACOUSTIC • QUBE

  • TIN