Page 1: Manual Cargador de granza 4 ENG

Instructions manualADHESIVE AUTOMATIC FEEDER

MA-5048-E 250913

Page 2: Manual Cargador de granza 4 ENG

Published by:

meler Aplicadores de Hot-melt S.A.P.I. Los Agustinos, calle G, nave D-43E - 31160 ORCOYEN Navarra (Spain)

Phone.: + 34 948 351 110 Fax: + 34 948 351 130e-mail: [email protected] site: www.meler.eu

Edition September 2013

© Copyright by meler

All rights reserved. Its reproduction, diffusion or use by electronic or other means of all or any part of this document without the express authorization of its owner is strictly prohibited.

The specifications and information contained in this manual may be modified without prior notice.

Page 3: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder Table of contents

TABLE OF CONTENTS

1. SAFETY GUIDELINES 1-1

General 1-1 Symbols 1-1 Mechanical components 1-2 Electrical components 1-2 Hydraulic components 1-2 Thermal components 1-3 Noise 1-3 Materials 1-3

2. INTRODUCTION 2-1

Overview 2-1 Intended use 2-2 Operation modes 2-2 Identificationofthehotmeltsystem 2-3 Main components 2-4 General 2-4 Controlpanel 2-5 Optional Equipment 2-5

3.INSTALLATION 3-1

Preliminaries 3-1 Installation requirements 3-1 ElectricalConsumption 3-2 Compressedair 3-2 Unpacking 3-2 Content 3-2 Feeder assembly 3-3 Electrical power supply connections 3-3 Pneumatic connection 3-3 Connection of the suction tube 3-4 Connecting sensors control 3-4 Installation of external control box 3-4 Placing the suction tube 3-5

Page 4: Manual Cargador de granza 4 ENG

Table of contents

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

4.USEOFTHEUNIT 4-1

Start up and automatic process 4-1 Sensor adjustments 4-2 Sensitivityadjustment 4-2 Lowleveladjustment 4-2 Settinghighlevelintank 4-2 Alarms 4-3 Loadfailurealarm 4-3 Adjustingalarmtimevalue 4-3 Alarmforopenlid 4-4

5.MAINTENANCE 5-1

Cleaning of the unit 5-1 Pneumatic system 5-1 Control of the load sensor 5-2 Inspection of the aspiration tube 5-2 Filter maintenance 5-2 Control of pneumatic vibrator 5-2

6. TECHNICAL SPECIFICATIONS 6-1

Generals 6-1

7. ELECTRIC DRAWINGS 7-1

Components list 7-1

8. PNEUMATIC DRAWINGS 8-1

9. SPARE PARTS 9-1

A. ELECTRICAL COMPONENTS OF THE CONTROL BOARD 9-2 B. SUCTION TUBE 9-4 C. FILTER-VALVE ASSEMBLY 9-6 D. SENSORS 9-8

Page 5: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB adhesive automatic feeder

1-1

Safety guidelines

General

The information contained in this section applies not only to every-day machine operation, but also to any procedure carried out on it, whether for preventive maintenance or in the case of repairs and the replacement of worn out parts.

It is very important to observe the safety warnings in this manual at all times. Failure to do so may result in personal injury and/or damage to the machine or the rest of the installation.

Before beginning work on the machine, read this manual carefully, and in case of any doubt, contact our Technical Service Center. We are available for any clarification that you might need.

Keep manuals in perfect condition and within reach of personnel that use the machine and perform maintenance on it.

Also provide necessary safety material: appropriate clothing, foot-wear, gloves and safety glasses.

In all cases, observe local regulations regarding risk prevention and safety.

Symbols

The symbols used on both the melter/applicator equipment and in this manual always represent the type of risk we are exposed to. Failure to abide by a warning signal may result in personal injury and/or damage to the machine or the rest of the installation.

WARNING: Risk of electrical shock. Carelessness may produce injury or death.

WARNING: Hot zone with high temperatures. Risk of burns. Use thermal protective equipment.

WARNING: System under pressure. Risk of burns or particle pro-jection. Use thermal protective equipment and glasses.

1. SAFETY GUIDELINES

Page 6: Manual Cargador de granza 4 ENG

1-2

Safety guidelines

meler hot-melt adhesive dispensing

MA-5048-GB adhesive automatic feeder

WARNING: Important information for the correct use of the system. May include one or several of the previous hazards, and therefore must be kept in mind to avoid damage and injury.

Mechanical components

The hot-melt installation, which is installed to this device, requires moving parts that can cause damage. Use the equipment correctly, and do not remove the safety guards while the equipment is in operation; prevent the risk of possible entrapment due to moving mechanical parts.

Do not use the machine if the safety devices are not in place or appear to be inadequately installed.

For maintenance or repair operations, stop the movement of moveable parts by turning off the main switch.

The device has no moving mechanical parts, so it does not pose risks to consider in this section.

Electrical components

The system operates with a single-phase current (230 V / 50 Hz) at a low power. Never handle the equipment with the power connected, as this may result in powerful electrical shocks.

The installation must be correctly grounded.

The installation’s power cable conductors must match the required electric current and voltage.

Periodically inspect the cables to check for crushing, wear and tear, as well as to prevent tripping and falls as a result of their placement.

Although the system meets EMC requirements, it is inadvisable to use devices that transmit high levels of radiation, i.e., mobile phones or soldering equipment in their vecinity.

Hydraulic components

As this is a pressurized system, precautions related to this type of equipment must be observed.

The system uses compressed air to 6 bar pressure. Before any manipulation, please ensure that the circuit has lost fully air

Page 7: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB adhesive automatic feeder

1-3

Safety guidelines

pressure. The risk of projection of particles at high speed can cause injury to a certain severity.

Extreme precautions with the residual pressure that could be contained in the circuit, before disconnecting any pneumatic feeding tube.

Thermal components

The entire system operates with temperatures reaching up to 230 °C (446 °F). The equipment must be operated using adequate protection (clothing, footwear, gloves and protective glasses) that completely cover exposed parts of the body.

Keep in mind that, due to the high temperatures reached, the heat does not dissipate immediately, even when the power (in this case, electric) source is disconnected. Therefore, use caution, even with the adhesive itself. It may remain very hot, even in a solid state.

In case of burns, immediately cool the affected area with clean, cold water. Seek medical attention as soon as possible from the company’s medical service or the nearest hospital. Do not try to remove the adhesive material from the skin.

Noise

The noise level of the system is well below allowable levels, and therefore does not present a specific risk to be taken into consideration.

Materials

‘meler’ systems are designed for use with hot-melt adhesives. They should not be used with any other type of material, and especially not with solvents, which may cause personal injury or damage to internal system components.

Always use original ‘meler’ components and replacement parts, which guarantee the correct system operation and service.

When using adhesive, follow the corresponding guidelines found in the Technical and Safety Sheets provided by the manufacturer. Pay special attention to the advised work temperatures in order to prevent adhesive burning and degradation.

Ventilate the work area adequately in order to remove the vapors produced. Avoid the prolonged inhalation of these vapors.

Page 8: Manual Cargador de granza 4 ENG

1-4

Safety guidelines

meler hot-melt adhesive dispensing

MA-5048-GB adhesive automatic feeder

This page is intentionally left blank.

Page 9: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

2-1

Introduction

Overview

The ‘meler’ adhesive automatic feeder ensures a continuous level of adhesive inside the melting tanks, eliminating the task of manually refilling by the user.

Each time the tank sensor detects a low adhesive level it sends a signal to the suction system which, from the container adhesive (or directly from the adhesive bag), transferred a load of adhesive to the melting tank. The loading process is indicated by a light signal. When the sensor detects the correct level again, the transfer of adhesive stops (a disconnection delay can be programmed).

2. INTRODUCTION

Page 10: Manual Cargador de granza 4 ENG

2-2

Introduction

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

An alarm system, timed from the detection of low level, warns of possible flaws in the loading or completely emptying the container for its replenishment. The system triggers a combined signal, noise and intermittent light. The acoustic signal can be cancelled by the available button.

Once corrected incidence signal light turns off the unit by ‘RESET’ button.

The system provides a level of security in the hot-melt cast within the fuser team, as well as the absence of charred material (the adhesive is melting and contributing as it needs), prevents external contamination of the adhesive (in a totally enclosed system ) and facilitates the tasks of recharge

The unit can be installed in the range of ‘meler‘ hot-melt tanks, as well as other units on request.

It supplies the unit load (control, filter, sensors and aspiration mouth suction), together with some specific adaptation to the requested unit.

A 120 l capacity container for the adhesive is available as an accessory in order to give greater autonomy to the system.

Intended use

The adhesive feeder can be used exclusively for the functions described in this manual and under the constraints outlined in the same.

Do not modify the installation or use items not provided by ‘meler’. Any modification of an element or part of the facility must be consulted to manufacturer.

Do not us it to transfer liquids or materials others than those specified. Some adhesives can become sticky with moisture, causing a malfunction of the device.

Operation modes

The feeder has three service situations as described further on:

Loading mode_The device operates normally, loading the tank of the hot-melt system as often as low level the detector of the loading system, installed on the tank, indicates it.

Page 11: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

2-3

Introduction

This corresponds to an automatic process where the operator should not act on any element of control.

Alarmmode_The device stops the function of load, stopping the expulsion of air, in case the tube is obstructed or lack of adhesive in the adhesive container. In this situation a light and an acoustic signal is emitted, which can be overturned by the operator. After the intervention to replenish the system, the operator must push the reset button.

Stop mode_The device in off stays without tension, It does not signal any load control. However, the system keeps the air pressure in the input circuit.

Identificationofthehotmeltsystem

When you want to place orders for parts or materials or if you request support from our technical service you should indicate the reference and serial number of your granulate feeder.

These data and other information of a technical nature can be located on the identification plate on the electrical control box.

Page 12: Manual Cargador de granza 4 ENG

2-4

Introduction

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

Main components

General

1

3

4 5

12

8

10

9

2

11

147 13 6

1. Control Board2. Electric load valve 3. Unload Filter 4. Rotary fitting 5. Input air supply (from the grid)6. Output air supply to the suction area7. Connector power supply

8. Sensor closed lid 9. Pneumatic vibrator10. Suction area11. Flexible Load Tube12. Air feeding tube13. Sensor Connectors14. Load Sensor

Page 13: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

2-5

Introduction

Controlpanel

Optional Equipment

120L Container

1 2 6

78

1. Main switch 2. Power supply monitoring system 3. Led for activation of load sensing 4. Adjustment timer (not used)

5. Sensitivity adjustment of load sensor 6. Illuminated rearmament button 7. Reset button for acoustic signal 8. General protection fuse

54

3

Page 14: Manual Cargador de granza 4 ENG

2-6

Introduction

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

This page is intentionally left blank.

Page 15: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

3-1

Installation

3.INSTALLATIONWarning: The vacuum feeders are installed in equipment with updated technology with foreseeable risks.Therefore, you should allow only the access to skilled people, with sufficient training and experience in handling, installation or repair of such equipment.

Preliminaries

The feeder is normally supplied together with the melter unit, with the elements necessary for installation and use. However, some components must be supplied by the user depending on the location and connections of each facility including:

• Power cable for power supply • Tube for compressed air and connector• Appropriate and closed container for the adhesive

Installation requirements

Before installing or using a vacuum feeder we must ensure that the space for it allows the location, connection and use of the entire system. We must also ensure that the electrical and pneumatic supplies meet the requirements demanded by the used device.

90 100

500

170

295

220

Standard length 4 m

Page 16: Manual Cargador de granza 4 ENG

3-2

Installation

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

ElectricalConsumption

Before connecting the vacuum feeder we must take into account the total consumption of the system and provide an appropriate power supply.

Check nameplate of the feeder before the connection, in order to connect device to the appropriate voltage.

Connect and ensure a correct grounding of the device.

Warning: Risk of electrocution. Even when the equipment is turned off, voltage remains in the intake terminals, which may bedangerous during internal equipment manipulations.

The control panel of the feeder incorporates a general OFF switch that insulates the unit of its power supply. This protects against short circuits through a fuse with external access to it, but you must protect the entire installation from the power supply against overloads. Install a power switch for disconnecting the melter/applicator equipment from the electrical network.

The power associated with this protection is indicated on the nameplate of the feeder.

Compressed air

To install ‘meler’ vacuum feeder, it is necessary to have a dry, non-lubricated compressed air system with a maximum pressure of 6 bars.

The air inlet pipe is installed to 10 mm outer diameter.

Unpacking

Before proceeding with the installation of the vacuum feeder, it should be removed from its location on a pallet and examined in order to detect any possible breakage or deterioration.

Communicate any defect, even to the outer packing materials, to your ‘meler’ Representative or to the Main Office.

Content

If the feeder has been issued installed on a hot-melt system, all elements of the system are mounted on it, except the suction tube which should be connected to the swivel connector.

Page 17: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

3-3

Installation

If the feeder has been issued as an accessory to an existing system the packaging contains the tank lid for the hot-melt tank completely mounted where you should connect the suction tube and the swivel elbow connector.

Feeder assembly

If the vacuum feeder installed on an existing melter please follow the correspondent instructions for each model of meler unit.

Warning: Ensure that the earth cable of the sensor has been connected to the ground connection of the melter.

Electrical power supply connections

The vacuum feeder is supplied to be connected to the power supply of single phase 230 VAC, depending on their power consumption.

It is always imperative to install a good ground connection. The maximum and minimum values are listed on the nameplate of the system.

Warning: Risk of electrical shock. Carelessness may produce injury or death.

Connect and fix the power cable (3x0.75mm2) to the supplied plug.

Connect the plug to the control box fixing it with the metal clamp.

Connect the other end of the power cable to the power socket.

Pneumatic connection

Before connecting the pneumatic power to the vacuum feeder,make sure the pressure regulator on the system and the main air supply is completely closed.

Connect the vacuum feeder through a flexible tube with outsidediameter of 10 mm to the general air supply (6 bar max.) (1). The unit has a quick coupling for this connection.

Page 18: Manual Cargador de granza 4 ENG

3-4

Installation

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

The air outlet grid (2) is connected by a flexible hose outside diameter 10 mm to the Y quick connector (3) located in the area of the suction adhesive.

To be sure about the connection of the tubes in the inlet and the outlet, the valve is marked with the numbers 1 and 2 respectively. See the pictures.

Once connected, open the air supply verify that you have maximum 6 bar pressure. Pressures higher than that causes an unnecessary expense and the possibility to produce turbulences in the hot melt tank with consequent malfunction of the unit.

Connection of the suction tube

The suction tube should be connected to the swievel elbow of the vacuum feeder, inserting it into the inside of the metallic mouth down to its bottom. To facilitate its introduction, you can previously heat slightly the extreme of the plastic tube.

Place the swievel elbow to the most convenient position for installation, depending on the location of the hot melt container.

Therefore:

• Loose slightly the three fixing screws for the lid of the filter and set the swievel elbow.

• Place the swievel elbow to the desired position, twisting it in the required sense.

• Tight the three fixing screws to the position of the elbow and prevent their movement.

Connecting sensors control

The vacuum feeder has two control sensors for the control of the operation of the system.

The low level sensor detects a low level of adhesive in the tank, in order to activate the filling of adhesive and when it has reached the right level to stop this filling. The “lid closed” sensor allows the stop the filling procedure when the lid is opened, preventing the projection of adhesive to the outside.

Both sensors are wired in a single connector at the control box. This connection allows the installation of the control box away from the hot melt tank using an appropriate interconnection cable.

31

2

Page 19: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

3-5

Installation

Installation of external control box

In some situations, it will be necessary to place the control box away from the hot melt equipment. It should be taken into account, that the longer the air and the vacuum tubes are, the suction force will be reduced.

In order to bring the control box and the air supply closer to the adhesive container, you can install the control box away from the hot melt equipment and closer to the mouth of the suction tube.

Therefore take into account the following factors:

- Location and setting of the control box - Electric connections of the sensors

The control box, with the solenoid valve incorporated, is fixed with two screws to the provided squadron, following the attached drawing. On demand ‘meler’ will supply this squadron.

For the electrical connection, an interconnection extension cable between the electrical box and the plug of the installed sensors on the hot melt system is required.

36

17R6

321 2 Aguj. M6x1

91

91

116

n6,5 n6,5

R4

R4

Page 20: Manual Cargador de granza 4 ENG

3-6

Installation

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

Placing the suction tube

To transfer the adhesive from the adhesive container to the hot melt equipment, the suction tube should be inserted to the bottom of the container.

The four flaps that protects the entrance of the suction tube are designed to keep the suction mouth open and without obstructions. It maintains a free way for the suctioned adhesive.

The vibratory element (pneumatic) keeps the adhesive loose around the entrance to facilitate its suction.

The aspiration element uses compressed air. By the help of the venturi effect, a depression is created in it, that absorbs pearled and pallet adhesive and drives it to the shell of the hot-melt system.

The Venturi effect, applied to the vacuum feeder, consists in a decrease of the air pressure by an air flow inside the closed circuit while increasing the air speed when passing through the narrowing of the entry mouth.

As the entry of aspiration is connected to this point, the aspired adhesive stays in it and is transported to the hot-melt tank through the flexible communication hose.

AIR INPUT

DEPRESSION

AIR EXHAUST INTERNAL HOLES

Page 21: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

4-1

Use of the unit

This section presents how to use the vacuum feeder. Even if its operation is very simple, it should not be used by non-trained personnel.

Warning: An improper use can cause damage to the equipment itself or to the operator.

Start up and automatic process

The operation of the vacuum feeder is absolutely automatic and only needs to switch it on, to begin the automatic feeding when the low level sensor requests it.

Connect the switch on the side of the control panel. The green led flashes warning that the system is connected with voltage.

The automatic loading process is developed according to the following pattern:

4.USEOFTHEUNIT

Lowleveldetection Launchingthefeeder

StoppingthefeederSystemrefilled

DetectionofthecorrectlevelStartoftheover-leveltiming

Page 22: Manual Cargador de granza 4 ENG

4-2

Use of the unit

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

Sensor adjustments

Sensitivityadjustment

The adjustable sensitivity of the sensor, depending on the material used and the hysteresis admitted to the operation of the vacuum feeder is factory pre-setted and therefore it is NOT necessary to change. In most cases the factory setting is perfectly valid to use the vacuum feeder.

If it is necessary to correct the adjustment contact the Technical Services ’meler‘ or Area Representative.

Lowleveladjustment

The placement of the sensor with respect to the feeding bottom of the hot melt system tank determines the minimum quantity of molten adhesive that we are going to allow before the automatic refilling starts.

This position is regulated by sliding up or down the sensor from its fixation on the lid. To do this, loosen the nut who fixes the sensor, before moving it to the desired position. Once positioned, re-tighten the nut to fix it.

The sensor must be fixed so that at least 70 mm of the sensor is left beneath the lid.

Settinghighlevelintank

The maximum level achieved in the hot-melt system tank depends on the timer located within the control box.

Open the lid of the box with the four screws. Inside there is a programmable timer-relay for the adjustment of the times.

With the control on (LED of tension green ON), the following message is displayed.

By pressing the up or down arrow key (No. 2 or 5) select the value you want to change. This value is identified by an asterisk that appears on the left side of the selected parameter. If the is no asterisk, no parameter is selected.

E . V . 0 0 1 0A L A R M 0 0 9 0

* E . V . 0 0 1 0A L A R M 0 0 9 0

Page 23: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

4-3

Use of the unit

With the arrows left or right (No. 3 or 4) increase or decrease the value. In this case the value to be changed is change is for ‘EV’.

Alarms

Loadfailurealarm

Each time the load sensor detects low adhesive a safety timer is connected (Default 90 seconds). That controls of time lap the device is charging. This timer is resetted when the sensor detects correct adhesive level.

In case that within the scheduled time (90 seg) the level sensor has not detected the correct level, the system assumes the existence of a failure in the loading circuit and connects the warning signs:

- Amber light intermittent signal in the control panel - Beep buzzer

Both signals remain activated while they are not resetted.

Pressing the black button the acoustic signal can be overridden. Pressing the amber light button the system will be resetted. The security time will begin to count again.

You just have to press the reset button after having corrected the existing failures:

- Obstruction of aspiration tube or mouth- Mismatch of the sensitivity of the level sensor - Empty adhesive container

Adjustingalarmtimevalue

The delay of 90 seg. for the alarm can be adjusted, depending on the system requirements. The timer is located within the control box.

Open the lid of the box with the four screws.

Inside you can see the programmable timer-relay for the adjustment of the delays.

* E . V . 0 0 2 0A L A R M 0 0 9 0

Page 24: Manual Cargador de granza 4 ENG

4-4

Use of the unit

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

When the control box is switched on (green power LED ON), the following message is displayed.

By pressing the up or down arrow key (No. 2 or 5) select the value you want to change. This value is identified by an asterisk that appears on the left side of the selected parameter. If there is no asterisk, no parameter is selected.

With arrows left or right (No. 3 or 4) increase or decrease the value. In this case the value to change is for ‘ALARM’.

Alarmforopenlid

When you open the lid of the hot-melt tank, the inductive sensor gives the signal to the programmable relay to interrupt the loading procedure. Closing the lid, after 10 sec. the loading procedure restarts.

If keep the lid open longer than the time programmed into the parameter ‘ALARM’, the alarm is triggered and connects the warning signs:

- Amber light intermittent signal in the control panel - Beep buzzer

Both signals remain activated while you do not act on them.

Pressing the black button you can stop the acoustic signal.

Pressing the amber light reset button the system restarts except if the lid is still open.

E . V . 0 0 1 0* A L A R M 0 0 8 0

* E . V . 0 0 1 0A L A R M 0 0 9 0

E . V . 0 0 1 0A L A R M 0 0 9 0

Page 25: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

5-1

Maintenance

Warning: The vacuum feeder is a device with updated technologies but with certain risks. Therefore, you should allow only the right people, with sufficiently enough training and experience, handling, installation or repair of these devices.

The following table summarizes briefly the indications for proper maintenance of the vacuum feeder. Read carefully, in each case, the corresponding section.

If the device does not work or works incorrectly contact the Technical Services ’meler‘ or Area Representative.

Cleaning of the unit

To maintain the performance of the vacuum feeder in perfect functioning, all of its components must be maintained clean and especially the exits in the air suction tube. Eliminate waste that can clog the air outlets.

Keep clean and without obstructions the tube for the adhesive.

Clean items with a soft tissue and aspire the dust that can be accumulated.

Pneumatic system

Control regularily the pressure feeding circuit. Very low pressures do not allow proper loading of the adhesive. Very high pressures can produce splash of molten adhesive in the tank of the melting unit and even cooling of the hot melt.

Monitor periodically if there is any leak in the pneumatic circuit. In

5.MAINTENANCE

Operation Frecuency RefertoExternal cleaning Daily Cleaning of the unit

Pneumatic system - Daily: pressure control- Weekly: leakage inspection Pneumatic circuit

Load sensor - Daily: load control- Weekly: cleaning Control of load sensor

Suction tube Weekly Inspection aspiration tube

Air exhaust filter Weekly Filter maintenance

Pneumatic vibrator Weekly Control of pneumatic vibrator

Page 26: Manual Cargador de granza 4 ENG

5-2

Maintenance

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

addition to being a useless expense resulting in loss of pressure and thus malfunction of the system load.

Control of the load sensor

It is necessary to control if the load sensor is working properly and that it allows you to maintain the desired levels. A low load will cause a decline in the level and the possibility of not having the amount of necessary hot-melt adhesive. By contrast, an overload can cause the overfilling of the tank with subsequent sealing of the loading mouth.

The load sensor should remain clean of charred adhesive that may affect the proper level detection.

Inspection of the aspiration tube

Monitor that the aspiration tube is not obtured with sticked glue pallets or perls. This tube should be perfectly free of any glue plugs that impedes the smooth transfer of the adhesive from container to the tank of the melting unit.

The tube is mostly transparent to facilitate visual inspection of the same.

Filter maintenance

Periodically review the state of the filter located inside the discharge zone. Blow compressed air impurities that may have acceded to.

This filter avoids dust particles or glue pallets itself being spilled outside with the exhaust air. If it arrived to be plugged the system might not work properly.

To clean, unscrew the three screws of the rotary elbow lid and extract the filter.

Control of pneumatic vibrator

Reviewing the correct operation of the pneumatic vibrator located in the suction mouth. Ensures that it vibrates and its vibration is adequate.

Clean up the exhaust silencer of impurities and adhesive dust.

Page 27: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

6-1

Technical specifications

6. TECHNICAL SPECIFICATIONS

Generals

Adhesive typeMax. transfer lengthMax. transfer heightMax. refilling speedTube standard dimensionsRecommended air presssureConsumption at 6 barPower supplyContainer capacityMelter unitsDimensions

Control box + loading input

Suction tube

Filter

(*) Depending on the type and form of the adhesive

pads or pearls up to 12 mm25 m (*)8 m (*)400 kg/h (*)Ø30 mm x 4 m6 bar (dry air, non lubricated)360 l/min (loading)230V 1~ 50/60 Hz + N + PE120 lfor the full range ‘meler’

190 x 290 x 210 556 x 100 x 9020 mesh (< 1mm)

Page 28: Manual Cargador de granza 4 ENG

6-2

Technical specifications

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

This page is intentionally left blank.

Page 29: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

7-1

Electric drawings

7. ELECTRIC DRAWINGS

Components list

A1 Programmable relay ZEN10C3DRDV2 A2 Capacitive level sensor 200mmA3 Inductive detector M8x1 PNP NO CN1 Power supply female connector CN2 Female connector 8 poles CN3 Male connector 8 poles CN4 Solenoid valve connectorF1 Holders PF6 + Fuse 2A 6.35X32 G1 DC power supply P1 LED holder Ø5 PLD51 + 5mm green LED Diode P2 Yellow LED (pushbutton S2) P3 Buzzer KB26 24 V R1 Resistance 1K2 2% 1 / 4 W S1 ON / OFF 1 pole switchS2, S3 Button contact NO

Page 30: Manual Cargador de granza 4 ENG

7-2

Electric drawings

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

A B C D E F

A B C D E F

12

34

56

78

DIBUJADO/DRAWN

MODIFICADO/MODIFIED

CLIENTE/CUSTOMER

FECHA/DATE

NOMBRE/NAME

DENOMINACIÓN/NAME

EQUIPO/EQUIPMENT

REFERENCIA/REFERENCE

HOJA/SHEET:

HOJAS/SHEETS

DISP.:

SITC.:

JESUS ZAPATA

20/11/2007

21/11/2007

14

150025490

CARGADOR DE

GRANZA

/2.D1

+24V

/2.D1

0V

1/3­CN1

2/3 3/3

1 2

­F1

1 2

­P1

LN

PE

­G1

­S1

12

12

­R1

­A1

­CN1

#5

#5

#5

#5

#7

#7

#7

#7

#6

#6

#6

#2 #1

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

0V

0V

0V0V

0V

0V

0V

0V

#10

CA

RG

AD

OR

DE

GR

AN

ZAM

ELTE

R F

EED

ER

Page 31: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

7-3

Electric drawings

A B C D E F

A B C D E F

12

34

56

78

DIBUJADO/DRAWN

MODIFICADO/MODIFIED

CLIENTE/CUSTOMER

FECHA/DATE

NOMBRE/NAME

DENOMINACIÓN/NAME

EQUIPO/EQUIPMENT

REFERENCIA/REFERENCE

HOJA/SHEET:

HOJAS/SHEETS

DISP.:

SITC.:

JESUS ZAPATA

20/11/2007

21/11/2007

24

150025490

CARGADOR DE

GRANZA

/1.B8

+24V

/1.B8

0V

PNP

BKWHBN BU

+ SEÑA

L

SEÑA

L

­

­A2

1/8

­CN3

2/83/84/85/86/87/88/8

1/8

­CN2

2/83/84/85/86/87/88/8

1/3

­CN4

2/33/3

2 31­A3

X1 X2

­P2

3 4

­S2

3 4

­S3

X1 X2

­P3

ZEN 10C1DR­D­V2 CPU

OUTPUTS

Q0Q1

Q2Q3

/1.E6

­A1

COM

I0I1

I2I3

I4I5

ZEN 10C1DR­D­V2 CPU

INPUTS

/1.E6

­A1

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

+24V

0V

0V0V

0V

0V

0V

0V0V

0V

#13

#14

#14

#14

#15

#16

+24V

+24V

+24V

+24V

+24V

0V 0V

0V

0V

0V

#13

#13 #1

4

#14

#17

#18

#19

CONECTO

R SENSORES

PULS

ADOR RESET

PULS

ADOR PARO BOCINA

CONECTO

R ELE

CTR

OVALV

ULA

PULS

ADOR RESET

PILO

TO R

ESET

RES

ET L

AM

P

CA

RG

AD

OR

DE

GR

AN

ZAM

ELTE

R F

EED

ER

ZUM

BA

DO

RB

UZZ

ERPA

RO

ZU

MB

AD

OR

STO

P B

UZZ

ERPU

LSA

DO

R R

ESET

RES

ET S

WIT

CH

CO

NEC

TOR

ELE

CTR

OVÁ

LVU

LA S

OLE

NO

ID V

ALV

E C

ON

NEC

TOR

CO

NEC

TOR

SEN

SOR

ESSE

NSO

RS

CO

NN

ECTO

R

Page 32: Manual Cargador de granza 4 ENG

7-4

Electric drawings

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

This page is intentionally left blank.

Page 33: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

8-1

Pneumatic drawings

8. PNEUMATIC DRAWINGS

IDENT FECHA MODIFICACION REALIZADO APROBADOMATERIAL/MATERIAL TRATAMIENTO/TREATMENT

VALIDADO/CONFIRMDIBUJADO/DESIGN

NOMBRE/NAME

FECHA/DATE

TITULO/TITLE

ESCALA/SCALE

CERTIFICACION/CERTIFICATION TOLERANCIAS GENERALES/GENERAL TOLERANCES PESO/WEIGHT

REFERENCIAREFERENCE

SUS. A

CATEGORIA

DENOMINACION/DENOMINATION

Este plano es propiedad exclusiva de MELER APLICACIONES DE HOT - MELT S.A. y su reproducción total o parcial está totalmente prohibida y queda amparada bajo la legislación vigente Los contraventores serán perseguidos legalmente tanto en España como en el extranjero. El uso,copia, reproducción o venta de esta publicación, sólo podrá realizarse con autorizaciónexpresa y por escrito de MELER APLICACIONES DE HOT - MELT S.A.

Nº DE HOJAS

D.Z.D.

23/11/2007 23/11/2007

J.Z.

S/E

UNE EN 22768-1 F

CARGADOR DE GRANZA

ESQUEMA NEUMATICO

1 DE 1

Nota: Las cotas indicadas en el plano son despues del tratamiento. A todas las cotas con tolerancia se les debe de aplicar corrección de medida acorde al tratamiento indicado en el plano.

150025490N

dry air, filtered and non lubricated max. 6 bar

pneumatic vibratorair outputs

venturi system

solenoid valve 24VDC

Page 34: Manual Cargador de granza 4 ENG

8-2

Pneumatic drawings

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

This page is intentionally left blank.

Page 35: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

9-1

Spare parts

The list of the most common spare parts of the vacuum feeder appears in this chapter in order to provide you with quick and safe information. The spare parts are naturally assembled in several groups, located in the equipment.

As a visual aid it includes general images of the pieces, numbered to facilitate location within the drawing. The lists provide the name of the reference and parts.

9. SPARE PARTS

Page 36: Manual Cargador de granza 4 ENG

9-2

Spare parts

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

A. ELECTRICAL COMPONENTS OF THE CONTROL BOARD

1

4

2

7

3

6

9

10

8

6

5

4

3

12

11

12

13 14

13

Page 37: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

9-3

Spare parts

A. ELECTRICAL COMPONENTS OF THE CONTROL BOARD

Nº Ref. Description1 150025600 ProgrammablerelayOMRONZEN2 10110070 DCpowersupply230VAC/24VDC3 150025610 GreenLEDwithholder4 150021600 Mainswitch5 150023760 Elbowconnectorsocket6 150025620 FuseholderPF67 150025630 Buzzer24VDC8 16020000 Powersupplyassembly9 150022480 Yellowbuttonwithlight10 150022510 Blackbutton11 150022490 YellowLED12 150022520 Contactholder13 150022530 ContactN/O14 150025640 Fuse2A6.35x32

16020001 Completepowersupplyplug

Page 38: Manual Cargador de granza 4 ENG

9-4

Spare parts

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

B. SUCTION TUBE

10

3 1

5

8

9

7

6

2

4

Page 39: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

9-5

Spare parts

B. SUCTION TUBE

Nº Ref. Description1 150025650 FittingYØ10quickplug2 150025660 HosevacuumfeederØ30(meter)3 150025670 Metallicsuctiontube4 150025680 Venturisuctiontube5 150025690 Holdinglegsforsuctiontube6 150025700 Fitting90°3/8Ø10quickplug7 150025710 Pneumaticvibratorvacuumfeeder8 21300000 Silencer9 150110180 Straightfitting1/8Ø4quickplug10 150025740 ReductionØ10-Ø4quickplug

150025810 Completesuctiontubevacuumfeeder

Page 40: Manual Cargador de granza 4 ENG

9-6

Spare parts

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

C. FILTER-VALVE ASSEMBLY

4

1

2

6

3

5

Page 41: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

9-7

Spare parts

C. FILTER-VALVE ASSEMBLY

Nº Ref. Description1 150025750 Fitting90°1/4Ø102 150060080 Coilforsolenoidvalve24VDC(10W)3 150060050 Solenoidvalveconnector4 150025770 Filtermesh20mesh5 150060070 Completesolenoidvalve2/224VDC10W6 150025790 Fitting90°3/8Ø10quickplug

Page 42: Manual Cargador de granza 4 ENG

9-8

Spare parts

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

D. SENSORS

4

2

3

1

3.1

Page 43: Manual Cargador de granza 4 ENG

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

9-9

Spare parts

Nº Ref. Description1 16000003 CompletestraightmaleconnectorPt1002 150025800 Capacitivelevelsensor(amplifierandprobe)3 150025820 CableglandPG13.53.1 150025870 Capacitivelevelsensoro-rings4 150110170 InductivedetectorM8x1

D. SENSORS

Page 44: Manual Cargador de granza 4 ENG

9-10

Spare parts

meler hot-melt adhesive dispensing

MA-5048-GB Adhesive automatic feeder

This page is intentionally left blank.


Recommended