ZXDSL 9806H ZTE Broadband Universal Access System Hardware Description Manual Version 2.0 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: [email protected]
Transcript

ZXDSL 9806HZTE Broadband Universal Access System

Hardware Description Manual

Version 2.0

ZTE CORPORATIONZTE Plaza, Keji Road South,Hi-Tech Industrial Park,Nanshan District, Shenzhen,P. R. China518057Tel: (86) 755 26771900Fax: (86) 755 26770801URL: http://ensupport.zte.com.cnE-mail: [email protected]

LEGAL INFORMATION

Copyright © 2006 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution ofthis document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATIONor of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are dis-claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-fringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on theinformation contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subjectmatter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,the user of this document shall not acquire any license to the subject matter herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

1.0 31/01/2009 First version

Serial Number: sjzl20090272

Contents

Preface...............................................................i

Overview...........................................................1System Components ....................................................... 1

Application Scenarios ...................................................... 1

Features........................................................................ 1

Interfaces...................................................................... 2

Power Supply Requirements............................................. 2

System Hardware..............................................5Overview....................................................................... 5

Shelf............................................................................. 6

SCCB Card..................................................................... 7

Subcards......................................................................11

ASTEB Card ..................................................................13

ASTDE Card..................................................................14

VSTDC Card..................................................................15

SSTEB Card ..................................................................16

ATLC/ATLA Card ............................................................17

Power Cards .................................................................18

Backplane ....................................................................19

Fan Box........................................................................19

Figures ............................................................21

Tables .............................................................23

List of Glossary................................................25

Preface

Purpose This manual provides ZXDSL 9806H (V2.0) ZTE Broadband Uni-versal Access System hardware description.

IntendedAudience

This manual is intended for engineers and technicians who performinstallation and operation activities on the ZXDSL 9806H (V2.0)ZTE Broadband Universal Access System.

Prerequisite Skilland Knowledge

To use this document effectively, users should have a basic conceptof xDSL technologies, telecommunications technology, and AccessNetwork.

What Is in ThisManual

This manual contains the following chapters:

Chapter Summary

Chapter 1, Overview Introduces the systemcomponents, applicable scenarios,features, interfaces and powersupply requirements.

Chapter 2, System Hardware Describes the system hardwaresuch as shelf, cards, backplaneand fan box.

RelatedDocumentation

The following documentation is related to this manual:

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemDocumentation Guide

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemFeature Description Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemProduct Description Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemExpansion Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemCutover Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemTroubleshooting Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemAlarms Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemRoutine Maintenance Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemVersion Update Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemNetwork Management User Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemConfiguration Manual (CLI)

Confidential and Proprietary Information of ZTE CORPORATION i

ZXDSL 9806H Hardware Description Manual

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemConfiguration Manual (NetNumen)

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemCommand Manual (Volume I)

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemCommand Manual (Volume II)

� ZXDSL 9806H (V2.0) ZTE Broadband Universal Access SystemCommand Manual (Volume III)

How to Get inTouch

The following sections provide information on how to obtain sup-port for the documentation and the software.

If you have problems, questions, comments, or sugges-tions regarding your product, contact us by e-mail at [email protected]. You can also call our customer support centerat (86) 755 26771900 and (86) 800-9830-9830.

ZTE welcomes your comments and suggestions on the quality andusefulness of this document. For further questions, comments, orsuggestions on the documentation, you can contact us by e-mailat [email protected]; or you can fax your comments and sugges-tions to (86) 755 26772236. You can also browse our websiteat http://support.zte.com.cn, which contains various interestingsubjects like documentation, knowledge base, forum and servicerequest.

Declaration ofRoHS Compliance

To minimize the environmental impact and take more responsi-bility to the earth we live, this document shall serve as formaldeclaration that manufactured by ZTE CORPORATION is in com-pliance with the Directive 2002/95/EC of the European Parliament- RoHS (Restriction of Hazardous Substances) with respect to thefollowing substances:

� Lead (Pb)

� Mercury (Hg)

� Cadmium (Cd)

� Hexavalent Chromium (Cr (VI))

� PolyBrominated Biphenyls (PBB’s)

� PolyBrominated Diphenyl Ethers (PBDE’s)

This declaration is issued based on our current level of knowledge.Since conditions of use are outside our control, ZTE CORPORATIONmakes no warranties, express or implied, and assumes no liability inconnection with the use of this information.

ii Confidential and Proprietary Information of ZTE CORPORATION

C h a p t e r 1

Overview

Table of ContentsSystem Components ........................................................... 1Application Scenarios .......................................................... 1Features............................................................................ 1Interfaces.......................................................................... 2Power Supply Requirements................................................. 2

System ComponentsZXDSL 9806H is a broadband and narrowband integrated compactaccess equipment.

ZXDSL 9806H system structure consists of the following parts:

Part Name Number

Backplane 1

Power card 1

Master control card 1

User card 4 (maximum)

Fan box 1

Application ScenariosZXDSL 9806H is an integrated compact access equipment. It isdesigned for small number of users.

FeaturesTable 1 lists ZXDSL 9806H features.

Confidential and Proprietary Information of ZTE CORPORATION 1

ZXDSL 9806H Hardware Description Manual

TABLE 1 ZXDSL 9806H FEATURES

Feature Number

ADSL/ADSL2+ users 96/64

VDSL2 users 64

Uplink port 2 gigabit fiber/electric ports, 2megabit Ethernet electric/fiberport, 1 EPON/GPON ONU port

VoIP sources Supports 128 routes VoIPresources

Total narrowband VoIP users 192

ZXDSL 9806H adopts front panel access. It supports cards (bothmaster control card and user cards) hot swapping. Its power sup-ply can be AC or DC.

InterfacesZXDSL 9806H consists of the following interfaces:

Type Interface Name Number

MGT 1

Console 1

Management

Monitor 1

Gigabit Fiber/ElectricPort

2

Megabit EthernetFiber/Electric Port

2

Uplink/Cascade Port

EPON/GPON Port 1

ADSL Card User interface percard

24/16 in total

VDSL Card User interface percard

16

Narrowband User interface percard

48 (ATLC)

24 (ATLA

Power Supply RequirementsZXDSL 9806H power supply requirements are as follows:

2 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 1 Overview

� DC: -48 V (-38.4 V – 60 V)

� AC: 110/220 V (85 V – 264 V)

Confidential and Proprietary Information of ZTE CORPORATION 3

ZXDSL 9806H Hardware Description Manual

This page is intentionally blank.

4 Confidential and Proprietary Information of ZTE CORPORATION

C h a p t e r 2

System Hardware

Table of ContentsOverview........................................................................... 5Shelf................................................................................. 6SCCB Card ........................................................................ 7Subcards..........................................................................11ASTEB Card ......................................................................13ASTDE Card......................................................................14VSTDC Card......................................................................15SSTEB Card ......................................................................16ATLC/ATLA Card ................................................................17Power Cards .....................................................................18Backplane ........................................................................19Fan Box............................................................................19

OverviewZXDSL 9806H is composed of cards, backplane and fan template.

Table 2 lists all ZXDSL 9806H cards.

TABLE 2 ZXDSL 9806H CARDS

Name Function Interface

SCCB System control andswitch card

One MGT, one consoleand one monitorinterface

VOPCB VoIP subcard, voicecoding and decoding,packet wrapping andunwrapping and 128route VoIP supply

None

FEUA Uplink subcard Two Megabit electricinterfaces

FEUB Uplink subcard One Megabit electricinterface and oneMegabit fiber interface

FEUC Uplink subcard Two Megabit fiberinterfaces

Confidential and Proprietary Information of ZTE CORPORATION 5

ZXDSL 9806H Hardware Description Manual

Name Function Interface

GFUA Uplink subcard Two Gigabit electricinterfaces

GFUB Uplink subcard One Gigabit electricinterface and oneGigabit fiber interface

GFUC Uplink subcard Two Gigabit fiberinterfaces

EPNA Uplink subcard One EPON interface

GPNB Uplink subcard One GPON interface

ASTEB ADSL user access withinside distributor

24 route PSTN and 24route ADSL socket

ASTDE ADSL user access withbuild-in distributor

16 route PSTN andADSL socket

VSTDC VDSL user access withbuild-in distributor

16 route PSTN andADSL socket

SSTEB SHDSL user accesswith build-indistributor

24 route SHDSLsocket

ATLC/ALTA Narrowband VoIPaccess

48/24 narrowbanduser interface

PWDH -48 V DC powersupply

3 core power socket

PWDA 220 V/100 V AC powersupply

3 core power socket

ShelfThis topic covers ZXDSL 9806H shelf structure, configuration andpower consumption.

Structure Figure 1 shows shelf structure.

FIGURE 1 SHELF STRUCTURE

6 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

Dimensions: 88.1 mm x 482.6 mm x 240 mm Height x Width xDepth

Full Configuration In full configuration, the shelf can hold one backplane, one powercard, one SCCB card, four user cards and one fan box. Figure 2shows shelf full configuration.

FIGURE 2 FULL SHELF CONFIGURATION

MinimumConfiguration

One backplane, one power card, one SCCB card and one fan box.

PowerConsumption

ADSL full configuration power consumption: 135 W

VDSL full configuration power consumption: 121 W

SCCB CardFunctions The following are the SCCB card functions:

� User card configuration, management and control

� 4 × 24 route ADSL/ADSL2+ and 4 × 16 VDSL2 route integra-tion

� Using backplane interfaces to execute Ethernet switch card ser-vice access and data exchange between uplink port and cas-cade port on main control card

� Route chips control and management

� Provides two GE/FE electric/fiber interfaces, one GE/FE elec-tric/fiber interface or one GPON/EPON interface with uplinksubcard

� Provides voice service with VoIP subcard

� Two interfaces: MGT interface and Monitor interface

Structure Figure 3 shows SCCB card hardware structure.

Confidential and Proprietary Information of ZTE CORPORATION 7

ZXDSL 9806H Hardware Description Manual

FIGURE 3 SCCB CARD STRUCTURE

Panels SCCB card panels can adopt eight interface configurations depend-ing on different uplink subcard types. Figure 4, Figure 5, Figure6, Figure 7, Figure 8, Figure 9, Figure 10 and Figure 11 show thecard interface configuration.

FIGURE 4 SCCB CARD PANEL - TYPE 1

FIGURE 5 SCCB CARD PANEL - TYPE 2

8 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

FIGURE 6 SCCB CARD PANEL - TYPE 3

FIGURE 7 SCCB CARD PANEL - TYPE 4

FIGURE 8 SCCB CARD PANEL - TYPE 5

FIGURE 9 SCCB CARD PANEL - TYPE 6

Confidential and Proprietary Information of ZTE CORPORATION 9

ZXDSL 9806H Hardware Description Manual

FIGURE 10 SCCB CARD PANEL - TYPE 7

FIGURE 11 SCCB CARD PANEL - TYPE 7

Besides uplink interfaces, SCCB card contains three managementinterfaces:

� One MGT for out-of-band management and equipment adjust-ment

� One Console for local super terminal management

� One Monitor for switches input signal

Indicators Table 3 lists SCCB card indicators.

TABLE 3 SCCB CARD INDICATORS

Indicator Color Status Description

RUN Green ON The deviceis runningnormally.

ON Power ONPWR Green

OFF Power OFF

ON Optical link ONL1, L2 Green

OFF Optical link OFF

10 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

Indicator Color Status Description

ON Link ONGreen

OFF Link OFF

ON Data flowoccurs

OFF No data flowoccurs

LAN indicators

Yellow

Flashing Data flowoccurs

Features Table 4 lists SCCB card features.

TABLE 4 SCCB CARD FEATURES

Items Features

Dimensions 44 mm x 120 mm x 225 mm(Height x Width x Depth)

Maximum user number 96 ADSL/ADSL2+ or 64 VDSL or192 POTS users

Power Consumption 7.49 W

Hot Swapping Yes

SubcardsSubcards include VoIP subcard and uplink subcards.

� Uplink subcards provide uplink service for subscribers withmegabit/gigabit optical/electrical interfaces and GPON/EPONinterfaces.

� VoIP subcard provides VoIP function with 128 VoIP sources.

Panels � FEUA/FEUB/FEUC subcards use the same PCB while adopt dif-ferent interface modules. The panel is shown in Figure 12.

Confidential and Proprietary Information of ZTE CORPORATION 11

ZXDSL 9806H Hardware Description Manual

FIGURE 12 FEUA/FEUB/FEUC SUBCARD PANEL

� GFUA/GFUB/GFUC subcards use the same PCB while adopt dif-ferent interface modules. The panel is shown in Figure 13.

FIGURE 13 GFUA/GFUB/GFUC SUBCARD PANEL

� EPNA subcard contains an EPON interface. Subcard linksthrough GMII to control exchange card and executes systemuplink function.

� GPNB subcard contains a GPON interface. Subcard linksthrough GMII to control exchange card and executes systemuplink function.

� VOPCB subcard contains no interface and works by beingplugged-in SCCB card. It functions include voice coding anddecoding, packet wrapping and unwrapping and 128 routeVoIP supply.

12 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

Subcard PowerConsumption

Table 5 lists the subcard power consumption.

TABLE 5 SUBCARD POWER CONSUMPTION

Subcard Power Consumption

GFUA/GFUB/GFUC 3 W

FEUA/FEUB/FEUC 1 W

EPNA 5 W

GPNB 11 W

ASTEB CardASTEB card realizes ADSL/ADSL2+ service access by executingmessage exchange from ATM to IP. Its maximum transmissionlength is 6.5 Km, upstream rate is 24 Mbps and downstream rateis 1 Mbps.

Structure Figure 14 shows ASTEB card structure.

FIGURE 14 ASTEB STRUCTURE

Panel Figure 15 shows ASTEB card panel.

FIGURE 15 ASTEB CARD PANEL

There are two sockets on ASTEB card.

� Socket with interface name ’USER’.

� Socket with interface name ’PSTN’ for VoIP message transmis-sion.

Features Table 6 lists ASTEB card features.

TABLE 6 ASTEB CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

Confidential and Proprietary Information of ZTE CORPORATION 13

ZXDSL 9806H Hardware Description Manual

Items Features

For the biggest frame: < 10 msecIP frame transmission delay

For the smallest frame: <1 msec

IP frame transmission losing rate <10-7

IP frame transmission error rate <10-6

Power Consumption 28 W

Hot Swapping Yes

ASTDE CardASTDE card realizes ADSL/ADSL2+ service access by executingmessage exchange from ATM to IP. Its maximum transmissionlength is 6.5 Km, upstream rate is 24 Mbps and downstream rateis 1 Mbps.

ASTDE card works in compliance with ETSI TS101-952-1-1 stan-dards.

Structure Figure 16 shows ASTDE card structure.

FIGURE 16 ASTDE STRUCTURE

Panel Figure 17 shows ASTDE card panel.

FIGURE 17 ASTDE CARD PANEL

There are 2 sockets in ASTDE card.

� Socket with interface name ’USER’.

� Socket with interface name ’PSTN’ for VoIP message transmis-sion.

Features Table 7 lists ASTDE card features.

TABLE 7 ASTDE CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

14 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

Items Features

For the biggest frame: < 10 msecIP frame transmission delay

For the smallest frame: < 1 msec

IP frame transmission losing rate <10-7

IP frame transmission error rate <10-6

Power Consumption 24 W

Hot Swapping Yes

VSTDC CardVSTDC card realizes VDSL2 service access by executing messageexchange from ATM to IP. Its maximum transmission length is 2.5Km, upstream rate is 85 Mbps and downstream rate is 50 Mbps.

Structure Figure 18 shows VSTDC card structure.

FIGURE 18 VSTDC CARD STRUCTURE

Panel Figure 19 shows VSTDC card panel.

FIGURE 19 VSTDC CARD PANEL

There are two sockets on VSTDC card.

� Socket with interface name ’USER’.

� Socket with interface name ’PSTN’ for VoIP message transmis-sion.

Features Table 8 lists VSTDC card features.

TABLE 8 VSTDC CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

For the biggest frame: < 10 msecIP frame transmission delay

For the smallest frame: <1 msec

Confidential and Proprietary Information of ZTE CORPORATION 15

ZXDSL 9806H Hardware Description Manual

Items Features

IP frame transmission losing rate <10-7

IP frame transmission error rate <10-6

Power Consumption 36 W

Hot Swapping Yes

SSTEB CardSSTEB card provides 24 routes SHDSL service access. Its maxi-mum transmission length is 6 Km, symmetric upstream and down-stream rate ranging from 192 kbps to 2312 kbps.

Structure Figure 20 shows SSTEB card structure.

FIGURE 20 SSTEB CARD STRUCTURE

Panel Figure 21 shows SSTEB card panel.

FIGURE 21 SSTEB CARD PANEL

There is one socket on SSTEB card.

� Socket with interface name ’USER’.

Features Table 9 lists SSTEB card features.

TABLE 9 SSTEB CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

For the biggest frame: < 10 msecIP frame transmission delay

For the smallest frame: <1 msec

IP frame transmission losing rate <10-7

IP frame transmission error rate <10-6

16 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

Items Features

Power Consumption 35 W

Hot Swapping Yes

ATLC/ATLA CardATLC card has a 48 route narrowband voice interface and can re-alize 48 route POTS users access. ATLA card has a 24 narrowbandvoice interface and can realize 24 route POTS users access. Bothcards can offer ringing tone and cable test functions.

� ATLC card has a 48 route narrowband voice interface and canrealize 48 route POTS user access.

� ATLA card has a 24 narrowband voice interface and can realize24 route POTS user access.

� Both cards can offer belling stream and cable test functions.

Structure Figure 22 shows ATLC/ATLA card structure.

FIGURE 22 ATLC/ATLA STRUCTURE

Panel Figure 23 shows ATLC card panel.

FIGURE 23 ATLC CARD PANEL

Figure 24 shows ATLA card panel.

FIGURE 24 ATLA CARD PANEL

Interfaces � Two PSTN sockets with interface names ’PSTN1’ and ’PSTN2’on ATLC card.

� One PSTN socket with interface name ’USER’ on ATLA card.

Indicators Table 10 lists ATLC/ATLA card indicators.

Confidential and Proprietary Information of ZTE CORPORATION 17

ZXDSL 9806H Hardware Description Manual

TABLE 10 ATLC/ATLA CARD INDICATORS

Indicator Color Status Description

RUN Green ON The deviceis runningnormally.

ALM Red ON The device orits softwareis runningabnormally.

HOOK Green ON One or moreusers hook-on.

Features Table 11 lists ATLC/ATLA card features.

TABLE 11 ATLC/ATLA CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

ATLC: 46.88 WPower Consumption

ATLA: 23.84 W

Hot Swapping Yes

Power CardsPWDH adopts – 48 V DC input current and – 38.4 VDC – 60 VDCinput voltage. Its output is 3.3 V DC-DC or – 48 VDC.

PWAH adopts 110 V- 220 V AC input and its voltage ranges from85 VAC to 264 VAC. Its output is 3.3 V or – 48 VDC.

Panel Figure 25 shows PWDH card panel.

FIGURE 25 PWDH CARD PANEL

Figure 26 shows PWAH card panel.

18 Confidential and Proprietary Information of ZTE CORPORATION

Chapter 2 System Hardware

FIGURE 26 PWAH CARD PANEL

Indicators Table 12 lists PWDH/PWAH card indicators.

TABLE 12 PWDH/PWAH CARD INDICATORS

Indicator Color Status Description

Green ON The deviceis runningnormally.

RUN

Red ON Alarm

Features Table 13 lists PWDH/ PWAH card features.

TABLE 13 PWDH/PWAH CARD FEATURES

Items Features

Dimensions 22 mm x 280 mm x 225 mm(Height x Width x Depth)

PWDH: 20 WPower Consumption

PWAH: 12.5 W

BackplaneInterface The following lists backplane build-in interfaces:

� SCCB and user cards interfaces

� Power card interface: - 48 V GND, 3.3 V GND

� Fan socket: - 48 V, - 48 V GND, fan tester and control

Features Dimensions: 320 mm x 84 mm (Height x Width)

Fan BoxFeatures Fan box is fitted on the left side of shelf and it acts as an exhaust

for the inside hot air. There is a fan control card built inside to testand control its operation. Fan unit can be hot swapped.

Confidential and Proprietary Information of ZTE CORPORATION 19

ZXDSL 9806H Hardware Description Manual

PowerConsumption

11 W

20 Confidential and Proprietary Information of ZTE CORPORATION

Figures

Figure 1 Shelf Structure ...................................................... 6

Figure 2 Full Shelf Configuration ........................................... 7

Figure 3 SCCB Card Structure .............................................. 8

Figure 4 SCCB Card Panel - Type 1........................................ 8

Figure 5 SCCB Card Panel - Type 2........................................ 8

Figure 6 SCCB Card Panel - Type 3........................................ 9

Figure 7 SCCB Card Panel - Type 4........................................ 9

Figure 8 SCCB Card Panel - Type 5........................................ 9

Figure 9 SCCB Card Panel - Type 6........................................ 9

Figure 10 SCCB Card Panel - Type 7.....................................10

Figure 11 SCCB Card Panel - Type 7.....................................10

Figure 12 FEUA/FEUB/FEUC Subcard Panel............................12

Figure 13 GFUA/GFUB/GFUC Subcard Panel...........................12

Figure 14 ASTEB Structure..................................................13

Figure 15 ASTEB Card Panel................................................13

Figure 16 ASTDE Structure .................................................14

Figure 17 ASTDE Card Panel ...............................................14

Figure 18 VSTDC Card Structure..........................................15

Figure 19 VSTDC Card Panel ...............................................15

Figure 20 SSTEB Card Structure ..........................................16

Figure 21 SSTEB Card Panel................................................16

Figure 22 ATLC/ATLA Structure............................................17

Figure 23 ATLC Card Panel ..................................................17

Figure 24 ATLA Card Panel ..................................................17

Figure 25 PWDH Card Panel ................................................18

Figure 26 PWAH Card Panel ................................................19

Confidential and Proprietary Information of ZTE CORPORATION 21

ZXDSL 9806H Hardware Description Manual

This page is intentionally blank.

22 Confidential and Proprietary Information of ZTE CORPORATION

Tables

Table 1 ZXDSL 9806H Features............................................. 2

Table 2 ZXDSL 9806H Cards................................................. 5

Table 3 SCCB Card Indicators ..............................................10

Table 4 SCCB Card Features................................................11

Table 5 Subcard Power Consumption ....................................13

Table 6 ASTEB CARD FEATURES...........................................13

Table 7 ASTDE Card Features ..............................................14

Table 8 VSTDC Card Features ..............................................15

Table 9 SSTEB Card Features ..............................................16

Table 10 ATLC/ATLA Card Indicators .....................................18

Table 11 ATLC/ATLA Card Features.......................................18

Table 12 PWDH/PWAH Card Indicators..................................19

Table 13 PWDH/PWAH Card Features....................................19

Confidential and Proprietary Information of ZTE CORPORATION 23

ZXDSL 9806H Hardware Description Manual

This page is intentionally blank.

24 Confidential and Proprietary Information of ZTE CORPORATION

List of Glossary

AC - Alternating Current

ADSL - Asymmetrical Digital Subscriber Line

ATM - Asynchronous Transfer Mode

DC - Direct Current

EPON - Ethernet Passive Optical Network

GPON - Gigabit Passive Optical Network

IP - Internet Protocol

ONU - Optical Network Unit

PCB - Physical Control Block

POTS - Plain Old Telephone Service

PSTN - Public Switched Telephone Network

SHDSL - Single-pair High Digital Subscriber Line

VDSL - Very High Speed Digital Subscriber Line

VDSL2 - Very High Bit Rate Digital Subscriber Line 2

VoIP - Voice over Internet Protocol

Confidential and Proprietary Information of ZTE CORPORATION 25