    Installation, Operation and Maintenance

    www.grindex.com

    No: 88 20 77 Revision 01 2010.02

    MATADOR MSHA - 8106.081

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    2/20

    Installation, Operation and Maintenance Matador

    2

    GuaranteeGrindex undertakes to remedy faults in productssold by Grindex provided: that the fault is due to defects in design, ma-

    terials or workmanship; that the fault is reported to Grindex or Grin-

    dexs representative during the guaranteeperiod;

    that the product is used only under condi-tions described in the care and maintenanceinstructions and in applications for which it isintended;

    that the monitoring equipment incorporated inthe product is correctly connected;

    that all service and repair work is done by aworkshop authorized by Grindex;

    that genuine Grindex parts are used.

    Hence, the guarantee does not cover faultscaused by decient maintenance, improperinstallation, incorrectly executed repair work ornormal wear and tear.

    Grindex assumes no liability for either bodilyinjuries, material damages or economic losses

    beyond what is stated above.Grindex guarantees that a spare parts stock willbe kept for 10 years after the manufacture ofthis product has been discontinued.

    The manufacturer reserves the right to alterperformance, specication or design withoutnotice.

    Guarantee ___________________2

    Data plate interpretation ________2

    Safety precautions _____________3

    Caution statement for MSHA _____4

    Product description ____________5Applications _____________________ 5

    Motor data ______________________ 5

    Dimensions and weights ____________ 6

    Performance curves ___________7

    Transportation and storage ______8

    Installation __________________8

    Electrical connections _______ 9-10

    Operation __________________11

    Care and maintenance ________12Safety precautions _______________ 12

    Inspection _____________________ 12

    Recommended inspections _______ 13-14

    Changing the oil _________________ 15

    Removing the impeller ____________ 16

    Installning the impeller and setting

    clearance ____________________17-18

    Tools ______________________19

    Service log _________________19

    Contents

    Data plate interpretation

    F

    E

    G

    C

    KA

    J S

    H

    D

    R

    B

    M

    L

    N

    O

    Q

    P

    I

    Data plate interpretation

    A Pump model

    B Serial No.

    C Rated voltage

    D Maximum height

    E Direction of impeller rotation

    F Direction of start reaction

    G Rated current

    H Maximum capacity

    I Degree of protection

    J Maximum submersion depth

    K Pump type No.

    L Frequency

    M Phases, type of current

    N Rated shaft power

    O Thermal classP Locked rotor code letter

    Q Country of origin

    R Maximum power consumption

    S Weight

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    3/20

    3

    Installation, Operation and Maintenance Matador

    Safety symbols

    Following symbols are used in

    this manual:

    For electrical related warnings.

    Safety precautions

    For all other warnings.

    Precautionary measuresIn order to minimize the risk of accident in con-nection with service work, the following rulesshould be followed:1. Before starting work on the pump, make sure

    that the pump is isolated from the power sup-ply and cannot be energized.

    2. Bear in mind the risk of accidents. Make surethat the machine or parts of the machine can-not roll or fall over and injure people or dam-age property.

    3. Make sure that the lifting equipment can han-dle the weight you want to lift and that it is in

    good condition.4. Don't work under suspended load.5. Carry out the work on a sturdy workbench.6. Bear in mind the danger of electrical acci-

    dents.7. Check that tools and other equipment are in

    good condition.8. Bear in mind health hazards. Observe strict

    cleanliness.9. When carrying out repair work take care to

    avoid injury by cutting or pinching.10.Make sure you have a rst-aid box near at

    hand.

    Follow all other health and safety regulation, lo-cal codes and ordinances.

    Safety regulations for the

    owner/operatorAll government regulations, local health andsafety codes shall be complied with.All dangers due to electricity must be avoided(for details consult the regulations of your localelectricity supply company).

    Unilateral modication andspare parts manufacturingModications or changes to the unit/installationshould only be carried out after consulting withGrindex.Original spare parts and accessories authorizedby the manufacturer are essential for compli-ance. The use of other parts can invalidate anyclaims for warranty or compensation.

    RecyclingLocal and/or private laws and regulations re-

    garding recycling must be followed. If there areno laws or regulations, or the product is not ac-cepted by an authorized recycling company, theproduct or its parts can be returned to the near-est Grindex sales company or service workshop.

    WARNING!Is used when there can be a

    risk to cause severe injury to

    people, death or considerable

    damage to property.

    CAUTION!Is used when there will be or

    is a risk to cause smaller inju-

    ry to people, or smaller dam-

    age to property.

    NOTE!Is used to pay intention to installation, use,

    operation or service information that is im-portant but not involved with any risk.

    This manual contains basic information on the

    installation, operting and maintenance andshould be followed carefully. It is essential thatthese instructions are carefully read beforeinstallation or commisioning by both theinstallation crew as well as those responsiblefor operation or maintenance. The operatinginstructions should always be readily available atthe location of the unit.

    DANGER!Is used when there will be a

    risk to cause severe injury to

    people, death or considerable

    damage to property.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    4/20

    Installation, Operation and Maintenance Matador

    4

    Warning data plate

    Pumps without built-in motor protection have an addi-

    tional data plate.

    The MSHA approval plate

    Federal Safety Regulations, as outlined in the

    applicable provisions of Title 30 of the Code ofFederal Regulations, require that in order tomaintain permissibility of this equipment thefollowing conditions must be satised:

    1. General SafetyFrequent inspections shall be made. All electricalparts, portable cable and wiring shall be kept ina safe condition. There shall be no openings intothe casings of the elctrical parts. The machineframe shall be effectively grounded. The powerwires shall not be used for grounding. The op-

    erating voltage shall match the voltage rating ofthe motor.

    2. Service and RepairInspections, service and repairs shall only bemade when the portable cable is disconnectedfrom the power supply. Work must be performedby trained personnel (preferably the manufac-turer or his agent) to insure that the permissiblepump is restored to its original state of safety inregard to all amearresting paths. Use replace-ment parts exactly as those furnished by the

    manufacturer. When cable entries are disturbedon pump or permissible control, they shall bereassembled in the approved manner and withparts identical to the parts of the original certi-cation.

    Caution statement for MSHA

    WARNING!Failure to restore the permis-

    sible equipment to its original

    state of safety will void the

    MSHA APPROVAL. The creation

    of a safety hazard will subject

    the owner/operator of a mine

    to citations and penalties un-

    der the law.

    3. Fastenings

    All bolts, nuts, screws and threaded covers shallbe properly tightened and secured.

    4. CablesA ame-resistant portable cable, bearing a MSHAassigned identication number, adequately pro-tected by an automatic circuit-interrupting de-vice shall be used. Special care shall be taken inhandling the cable to guard against mechanicalinjury and wear.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    5/20

    5

    Installation, Operation and Maintenance Matador

    Product descriptionApplications

    MatadorN &H are intended to be used for: pumping of water which may contain abrasive

    particles.

    The pump is designed for use in explosive envi-ronments in accordance with the following ap-proval. MSHA - Mine Safety and HealthAdministration, USA.

    The pumps are available in the following ver-sions:N= Normal head version

    H= High head versionLiquid temperature: standard version, max.40C (104F).

    Liquid density: max. 1100 kg/m3 (9.2 lb per USgal.).

    The pumped liquid may contain particles up toa size which corresponds to the openings in thestrainer. See drawing.

    The pH of the pumped liquid: 5 8.

    Depth of immersion: max. 20 m (65 ft).

    For other applications contact your nearestGrindex representative for information.

    WARNING!If the pump run dry or snore,

    the pump surface and the sur-

    rounding liquid may be hot.

    Bear in mind the risk of burn

    injuries.

    3~ 60 Hz, 3495 r/minRated output: 20 kW (27 hp)Max consumption 22 Kw (29.5 hp)

    Voltage

    V

    Rated current

    A

    Starting current

    A

    440 D 32 243

    460 D 31 215

    575 D 25 189

    600 D 25 198

    Motor dataMotor type: Squirrel-cage 3-phase inductionmotor for 60 Hz markets.

    Motor

    Squirrel-cage 3-phase induction motor for 60 Hzpumps.

    The motor is started by means of directon-linestart.

    The motor can be run continuously or intermit-tently with a maximum of 30 evenly spacedstarts per hour.

    Grindex motors are tested in according to IEC34-1.

    The stator is insulated to class F (155C, 311F).The motor is designed to supply its rated outputat 5 % variation of the rated voltage. 10% variation of the rated voltage, in respect ofthe temperature, can be accepted provided themotor does not run continuously under full load.The motor is designed to operate with a voltageimbalance of up to 2 % between the phases.(according to IEC 34-1)

    Monitoring equipmentIn pumps with MSHA-approval the 3-phasestator in-corporates two thermal protectors con-nected in series.The thermal protectors:

    open at 125C (260F)close at 85C (200F)

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    6/20

    Installation, Operation and Maintenance Matador

    6

    Dimensions and weightsMatador

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    7/20

    7

    Installation, Operation and Maintenance Matador

    Matador N, 60 Hz Matador H, 60 Hz

    Performance curvesEach pump is tested in accordance with ISO 9906.

    Capacity [l/s] [usgpm]

    Head [feet] / [m]

    1P [hp] / [kW]

    0 10 20 30 40 50 60 70 80 90

    0

    5

    10

    15

    20

    25

    30

    35

    40

    14

    16

    18

    20

    20

    40

    60

    80

    100

    120

    140

    0

    25

    30

    20

    100 300 500 700 900 1100 1300 1500

    1P [hp] / [kW]

    0 10 20 30 40 50

    0

    10

    20

    30

    40

    50

    60

    70

    12

    14

    16

    18

    20

    Capacity [l/s] [usgpm]

    Head [feet] / [m]

    30

    60

    90

    150

    120

    180

    0

    210

    240

    25

    30

    20

    100 200 300 400 500 600 700 800 900

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    8/20

    Installation, Operation and Maintenance Matador

    8

    InstallationPump installationRun the cables so that they do not have any

    sharp bends and are not pinched.Connect the discharge connection and motorcable. See Electrical connections.

    Lower the pump into the sump.

    Place the pump on a base which will prevent itfrom sinking into a soft sump bottom. Alternati-vely, the pump can be suspended by its liftinghandle just above the sump bottom.

    NOTE!Where required by local au-

    thorities an acceptable motor-circuit switch or other discon-

    necting device shall be provid-

    ed at the time of installation.

    NOTE!At certain installations and

    operation points on the pump

    curve the noise level 70 dB,

    noise level specied for theactual pump, can be exceeded.

    Transportation and storageThe pump may be transported and stored in a

    vertical or horizontal position. Make sure that itcannot roll or fall over.

    WARNING!Always lift the pump by its

    carrying handle or lifting eyes,

    never by the motor cable or

    the hose.

    WARNING!Before starting to work on thepump or moving the pump,

    make sure that the pump is

    isolated from the power sup-

    ply and cannot be energized.

    This applies to the control cir-

    cuit as well.

    The pump is frostproof as long as it is operating

    or is immersed in the liquid. If the pump is takenup when the temperature is below freezing, theimpeller may freeze. The pump shall be operatedfor a short period after being taken up in orderto expel all remaining water.

    A frozen impeller can be thawed by allowing thepump to stand immersed in the liquid for a shortperiod before it is started. Never use a nakedame to thaw the pump.

    For longer periods of storage, the pump must beprotected against moisture and heat. The impel-

    ler should be rotated by hand occasionally (forexample every other month) to prevent the sealsfrom sticking together. If the pump is stored formore than 6 months, this rotation is mandatory.

    After a long period of storage, the pump shouldbe inspected before it is put into operation. Payspecial attention to the seals and the cable entry.

    Follow the instructions under the heading Be-fore starting

    WARNING!

    Make sure that the pump can-not roll or fall over and injure

    people or damage property

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    9/20

    9

    Installation, Operation and Maintenance Matador

    Electrical connectionsAll electrical work shall be carried out under the

    supervision of an authorized electrician.

    Local codes and regulations shall be compliedwith.

    Check that the mains voltage and frequencyagree with the specications on the pump dataplate.

    NOTE! For safety reasons, the earth (ground)lead should be approx. 200 mm (7.9 in) longerthan the phase and monitoring leads. If the mo-tor cable is jerked loose by mistake, the earth(ground) lead should be the last lead to come

    loose from its terminal. This applies to both endsof the cable.

    Make sure that the pump is correctly earthed(grounded).

    When the pump is connected to the public mainsit may cause icker of incandescent lamps whenstarting. In this case the supply authority shouldbe notied before installing the pump.

    WARNING!All electrical equipment must

    be earthed (grounded). This

    applies to both pump equip-

    ment and any monitoring

    equipment. Failure to heed

    this warning may cause a le-

    thal accident. Make sure that

    the earth (ground) lead is cor-

    rectly connected by testing it.

    NOTE!Make sure that the monitoring

    equipment incorporated in the

    product is correctly connected

    and in use.

    WARNING!If the pump is equipped with

    automatic level control or con-

    tactor unit, there is a risk of

    sudden restart.

    WARNING!Bear in mind the risk of elec-

    trical shock if the electrical

    connections are not correctly

    carried out or if there is fault

    or damage on the pump.

    WARNING!If persons are likely tocome into physical contactwith the pump or pumpedmedia (liquid), e.g on con-struction sites and farms,the earthed (grounded)socket must have an addi-tional earth(ground-) faultprotection device (GFI)connected.

    WARNING!When pumping near a lake

    (jetties, beaches, ponds,fountains etc) a safety-dis-tance of at least 20 m (65ft) between the person andthe pump is applicable. Thepump must never be placeddirectly into a swim mingpool. If used in connectionwith swimming pools, spe-cial safety regulations ap-ply.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    10/20

    Installation, Operation and Maintenance Matador

    10

    SUBCABAWG

    o

    *Subcab AWG 550 24 00M

    ax.

    250V.

    Max.

    5A

    M

    ax.

    1.6

    A,cos=0.6

    M

    ax.

    2.5

    A,cos=1 WH or YE

    T1 T1

    WH or YE

    or GY

    or GY

    T2

    T2*BU

    *OG

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    11/20

    11

    Installation, Operation and Maintenance Matador

    OperationBefore startingCheck the oil level in the oil casing.Remove the fuses or open the circuit breakerand check that the impeller can be rotated byhand.Check that the monitoring equipment (if any)works.The impeller shall rotate clockwise, as viewedfrom above. When started, the pump will jerk inthe opposite direction to the direction in whichthe impeller rotates. See the gure.

    Starting jerk

    WARNING!Always lift the pump by its

    carrying handle or lifting eyes,

    never by the motor cable or

    the hose.

    CleaningIf the pump has been running in very dirty wa-ter, let it run for a while in clean water, or ushit through the discharge connection. If clay,cement or other similar dirt is left in the pump itmay clog the impeller and seal, preventing thepump from working.During a longer period out of operation, thepump must be test run every other month toprevent the mechanical seals from sticking to-gether.

    WARNING!Watch out for the starting jerk,

    which can be powerful.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    12/20

    Installation, Operation and Maintenance Matador

    12

    Care and maintenanceSafety precautions Inspection

    Regular inspection and preventive maintenanceensure more reliable operation.

    The pump should be inspected at least twice ayear, more frequently under severe operatingconditions.

    Under normal operating conditions, the pumpshould have a major overhaul in a service shoponce a year.

    This requires special tools and should be done byan authorized service shop.

    When the pump is new or when the seals havebeen replaced, inspection is recommended afterone week of operation.

    WARNING!Before starting to work on the

    pump or moving the pump,

    make sure that the pump is

    isolated from the power sup-

    ply and cannot be energized.

    This applies to the control cir-

    cuit as well.

    WARNING!Make sure that the pump can-

    not roll or fall over and injure

    people or damage property

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    13/20

    13

    Installation, Operation and Maintenance Matador

    Visible parts on pumpand installation

    Pump casing andimpeller

    Condition of the oil

    Oil quantity

    Liquid in the inspec-tion chamber

    Recommended inspections:

    Inspection of Action

    WARNING!If the seal leaks, the oil casing may be under pressure.

    Hold a rag over the oil casing screw in order to prevent

    splatter. See Safety precautions for additional informa-tion.

    WARNING!If there has been leakage, the stator casing may be un-

    der pressure. Hold a rag over the inspection screw to

    prevent splatter. See Safety precautions for additional

    information.

    Lay the pump on its side.Tilt the pump so that any liquid in the inspection chamber can run outthrough the hole.If there is water in the stator casing, the cause may be: that the inspection screw is not sufciently tight. that the O-ring on the inspection screw or its sealing surface is dam

    aged. that an O-ring is damaged. that the cable entry is leaking.

    If there is oil in the inspections chamber, the cause may be: that the inner mechanical seal is damaged. Contact a Grindex serv

    ice shop.

    Replace or x worn and damaged parts.Make sure that all screws, bolts and nuts are tight.

    Replace worn parts if they impair function.

    A check of the condition of the oil can show whether there has been anincreased leakage. Note! Air/oil mixture can be confused with water/oilmixture.Insert a tube (or hose) into the oil hole. Cover the top end of the tube andtake up a little oil from the bottom.Change the oil if it contains too much water.

    See Changing the oil. Check again one week after changing the oil.If the oil contains too much water again, the fault may be: that an oil screw is not sufciently tight. that the O-ring on an oil screw or its sealing surface is damaged. that the mechanical seal is damaged. Contact a Grindex service

    shop.

    1.2 litres (0.32 US gallon)

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    14/20

    Installation, Operation and Maintenance Matador

    14

    Recommended inspections:

    Inspection of Action

    Check that the following requirements are met: The cable entry must be tightened so that the clearance between the

    entrance ange and the MSHA-cover is 4.5 0.5 mm (5/32 - 13/64 in).Use a feeler gauge to check the clearance. A lock washer must securethe cable entry screw.

    The seal sleeve and the washers must conform to the outside diameterof the cables.

    If the cable entry has previously been disassembled, cut off a piece ofthe cable so that the seal sleeve closes around a new position on thecable.

    Replace the seal sleeve, if necessary.

    Replace the cable if the outer jacket is damaged. Make sure that the cabledo not have any sharp bends and are not pinched.

    If faulty, contact an electrician.

    Repair faults and notify supervisor of any faults or defects.

    Contact a Grindex service shop.

    Cables

    Starter equipment

    Pipes, valves and otherperipheral equipment

    Insulation resistance inthe stator

    Cable entry

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    15/20

    15

    Installation, Operation and Maintenance Matador

    WARNING!If the seal leaks, the oil casing

    may be under pressure. Hold

    a rag over the oil casing screw

    in order to prevent splatter.

    See Safety precautions for

    additional information.

    Explanation of symbols

    = Oil screw

    = Inspection plug

    It is easier to drain the oil if the other oil screwis also removed.

    Fill up with new oil.

    A parafn oil with viscosity close to ISO VG32 isrecommended. The pump is delivered from fac-tory with this type of oil.

    In applications where poisonous properties areof less concern, a mineral oil with viscosity up to

    ISO VG32 can be used.Always replace the O-rings on the oil screws. Putthe screws back and tighten them.

    Changing the oil

    Lift the pump horizontally with an overheadcrane and place on relief table.Turn the pump so that one of the oil screws

    faces downwards. Lock the pump with a supportpreventing it from rolling over.Unscrew the oil screw.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    16/20

    Installation, Operation and Maintenance Matador

    16

    Removing the impeller

    Lock the impeller with a screw driver or similar(L= min. 200 mm/7.9 inch), see g. to preventrotation of the impeller.Loosen and remove the impeller screw andwasher.

    Using a 12 mm hexagon bit adaptor (allensocket) with a 100 mm (4) extension turn the

    adjustment screw counter clockwise until theimpeller breaks free from the shaft.Remove the impeller.

    WARNING!Worn impellers often have

    very sharp edges. Use protec-

    tive gloves.

    N H

    Remove the strainer, the suction cover andO-ring.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    17/20

    17

    Installation, Operation and Maintenance Matador

    Mount the cover with its O-ring.Tighten the screws, tightening torque 76 Nm(57 lbf-ft).Make sure that the impeller rotates freely. If not,the adjustment screw and the conical sleeve hasnot been aligned and the shaft might have beendisplaced relative to the main bearing!

    Before assembly, check that the impeller screwis clean and easy to screw into the shaft end(a). This to prevent the shaft to rotate with theimpeller screw. Assemble the conical sleeve andthe impeller onto the shaft.

    Installing the impeller and

    setting clearance

    Make sure that the end of the shaft is clean andfree from burrs. Polish off any aws with neemery cloth. Grease end of shaft, conical sleeveand the threads of the adjustment screw. Theproper lubrication is grease for bearings e.g.Exxon Mobile Unirex N3 or equivalent.

    NOTE!Remove surplus grease from conical and cy-

    lindrical surfaces of the shaft and the sleeve

    thoroughly.

    Align the edge of the adjustment screw with theedge of the conical sleeve so that they are ush.Grease the threads of the screw and the washer.The proper lubrication of the screw and washeris lubricating grease for assembly of bolts etc.e.g. Kluber ALTEMP Q NB 50 or equivalent.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    18/20

    Installation, Operation and Maintenance Matador

    18

    Mount the strainer and the nuts,tightening torque 44 Nm (32.5 Lbf ft).

    N H

    Turn the adjustment screw clockwise until theimpeller makes contact with the suction cover.Tighten it further 1/8 turn, 45o . This will ensurethe correct clearance between the impeller and

    the suction cover in the next step.

    Lock the impeller with a screw driver or similar(L= min. 200 mm/7.9 inch), see g. to preventrotation of the impeller. Fit the washer and thegreased impeller screw and tighten, torque to 76Nm (57 lbf-ft).

    Check that the impeller rotates freely.

    When changing an impeller or after service, werecommend that the screw is rst tightened tothe prescribed torque and then turned an addi-tional 1/8 ( 45) of a revolution. The screw willbe loaded to its yield point and the load capacityof the jonit will be higher.

  • 7/30/2019 Manual Iom Msha Matador 60hz en Us

    19/20

    19

    Installation, Operation and Maintenance Matador

    ToolsMost of the tools needed for servicing the pump

    are tools normally included in every servicemanstool kit. However, there are some special toolsexclusively for this pump type without whichthe servicing of the pump will be difcult and thepump can be very easily damaged.

    Service logMost recent service date Pump No. Hours of operation Remarks Sign.

    Part No. Denomination Remarks

    51 084 00 Spring puller Spring removal

    51 088 00 Mounting sleeve Mechanical seal unit

    51 089 00 Mounting/Dismantling

    tool