© Ortho-Clinical Diagnostics, Inc. Publication No. SM3360-16 2002DEC10 Supersedes SM3360-16 2001OCT15 SERVICE MANUAL for the  Vitros 950 Chemistry System Vitros 950AT Chemistry System IMMUNO-WASH FLUID METERING ASSEMBLY E015_4301HA
Transcript
Page 1: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 1/12

© Ortho-Clinical Diagnostics, Inc.

Publication No. SM3360-16

2002DEC10

Supersedes SM3360-16

2001OCT15

SERVICE MANUAL

for the

 Vitros 950 Chemistry System

Vitros 950AT Chemistry System

IMMUNO-WASH FLUID METERING ASSEMBLY

E015_4301HA

Page 2: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 2/12

2 2002DEC10 – SM3360-16

PLEASE NOTE The information contained herein is based on the experience and knowledge relating to the subject mattergained by Ortho-Clinical Diagnostics, Inc. (OCD) prior to publication.

No patent license is granted by this information.

OCD reserves the right to change this information without notice, and makes no warranty, express orimplied, with respect to this information. OCD shall not be liable for any loss or damage, includingconsequential or special damages, resulting from any use of this information, even if loss or damage iscaused by the negligence or other fault of OCD.

This equipment includes parts and assemblies sensitive to damage from electrostatic

discharge. Use caution to prevent damage during all service procedures.

Description Page

Table of Contents

Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3TIP to Metering Position - Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

TIP to RESERVOIR - Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Page 3: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 3/12

Adjustments

2002DEC10 – SM3360-16 3

Section 1: Adjustments

TIP to Metering Position - Alignment

To Adjust:

[1] Check that a TIP is on the IMMUNO-RATE ARM.

[2] Touch:

Detach 1

[3] Observe the TIP as it enters the Metering hole. Does the TIP enter the hole without touching the side?

Purpose: To align the MOUNTING PLATE of the IMMUNO-RATE WASH METERING

ASSEMBLY.

Specification: The TIP on the IMMUNO-RATE ARM must not touch the RESERVOIR COVER when

the TIP enters or leaves the RESERVOIR.

When to Do: After replacement of the IMMUNO-RATE WASH METERING ASSEMBLY, PUMPASSEMBLY, or PUMP CARRIAGE.

“DIAGNOSTICS”

“MECHANISM EXERCISE DIAGNOSTICS”

“IMMUNO RATE SYSTEM”

“METERING ARM”

“CYCLE ARM”

“MULTIPLE”

“10”

“ENT”

“START”

Yes No

Advance to step 9. Advance to step 4.

E015_4303BA

TIP

ARM

IMMUNO-RATE

SCREW (3)

MOUNTING PLATE

METERING ASSEMBLY

IMMUNO-WASH FLUID

E015_4303BCA

Page 4: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 4/12

SERVICE MANUAL

4 2002DEC10 – SM3360-16

[4] Loosen the 3 SCREWS on the MOUNTING PLATE.

[5] Touch “START” and move the IMMUNO-RATE WASH METERING ASSEMBLY so the TIP does not touch

the side of the hole.

[6] Tighten the 3 SCREWS evenly.

[7] Touch “START” and check that the adjustment is correct.

[8] Do:

[9] Return the System to normal operation.

Adjustment

TIP to RESERVOIR - Alignment

O4308DCA

IMMUNO-RATE ARM

TIP

RESERVOIR

Page 5: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 5/12

Adjustments

2002DEC10 – SM3360-16 5

TIP to RESERVOIR - Alignment

To Adjust:

[1] Check that a TIP is on the IMMUNO-RATE ARM.

[2] Touch:

[3] Observe the TIP as it enters the hole in the RESERVOIR COVER. Does the TIP enter the hole without touching

the side?

Detach 2

[4] Loosen the 3 SCREWS on the RESERVOIR NEST.

[5] Touch “START” and move the RESERVOIR NEST so the TIP does not touch the side of the hole.

[6] Evenly tighten the 3 SCREWS.

[7] Touch “START” and check that the adjustment is correct.

[8] Return the System to normal operation.

Purpose: To align the RESERVOIR of the IMMUNO-RATE WASH METERING

ASSEMBLY.

Specification: The TIP on the IMMUNO-RATE ARM must be in the center or

1.0 mm (< 0.040 in.) from the center of the hole in the RESERVOIR COVER.

When To Do: After replacement of the IMMUNO-RATE WASH METERING ASSEMBLY,

PUMP ASSEMBLY, or PUMP CARRIAGE.Special Tools: None.

Special Requirements: None.

“DIAGNOSTICS”

“MECHANISM EXERCISE DIAGNOSTICS”

“IMMUNO RATE SYSTEM”

“METERING ARM”“ARM TO RESERVOIR POSITION”

Yes No

Advance to step 8. Advance to step 4.

E015_4302BA

E015_4302BCA

IMMUNO-RATE ARM

RESERVOIR

NESTSCREW (3)

TIP

Page 6: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 6/12

SERVICE MANUAL

6 2002DEC10 – SM3360-16

Page 7: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 7/12

Parts List

2002DEC10 – SM3360-16 7

Section 2: Parts List

Description Page

List of Figures

IMMUNO-WASH FLUID METERING ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

RESERVOIR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Page 8: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 8/12

SERVICE MANUAL

8 2002DEC10 – SM3360-16

Figure 1 IMMUNO-WASH FLUID METERING ASSEMBLY

18

17

16

15

19

11

1314

12

O4307ECA

1

2

3

4

6

7

8

9

10

5

Page 9: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 9/12

Parts List

2002DEC10 – SM3360-16 9

Figure 1 IMMUNO-WASH FLUID METERING ASSEMBLY

Item Part No. Description Qty. Notes

1 2B3103 Sensor - Gap 1

2 999347 Clamp - Sensor 1

3 273442 Screw 1

4 903756 Washer 1

5 748353 Screw - Mounting 26 999611 Motor and Pinion Assembly 1

7 356192 Shaft - Guide 1

8 354984 Bearing - Cam 1

9 354626 Cam - Lift 1

10 356933 Cam - Washer 1

11 1C3350 Spring 1

12 356936 Bushing 1

13 104459 Washer 1

14 748360 Screw 1

15 1C2191 Sensor 116 1H0126 Pump Assembly 1

17 2B3854 Flag - Sensor 1

18 337918 Screw 1

19 1C2169 Spring 1

Page 10: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 10/12

SERVICE MANUAL

10 2002DEC10 – SM3360-16

Figure 2 RESERVOIR ASSEMBLY

Figure 2 RESERVOIR ASSEMBLY

Item Part No. Description Qty. Notes

1 356496 Housing - Reservoir 1

2 356668 Spring 1

3 356582 Pin 1

4 356531 Holder - Cover 1

5 356497 Cover - Reservoir 1

6 356864 Seal - Reservoir 1

7 748360 Screw - SEMS, M4 x 12 3

8 066556 Washer 3

9 356669 Reservoir Assembly 1

E012_5025DA

1

2

3

9

E012_5025DCA

6

5

4

8

7

E012_5025DA

1

2

3

9

E012_5025DCA

6

5

4

8

7

Page 11: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 11/12

Parts List

2002DEC10 – SM3360-16 11

This page is intentionally blank.

Page 12: Manual Servicio Vitros 950

8/9/2019 Manual Servicio Vitros 950

http://slidepdf.com/reader/full/manual-servicio-vitros-950 12/12

Sm336016.FM+

P i t d I USA O th Cli i l Di ti I■

100 I di C k D i■

R h t N Y 14626

Vitros is a trademark.