Installation Instructions
and
Service Manual
Mark II Water Meter
With Model K2 Controller (No Automatic Blender)
THE FRED D. PFENING COMPANY
1075 W FIFTH AVE.
COLUMBUS, OHIO 43212
Phone: 614-294-5361
Fax: 614-294-1633
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
2
TABLE OF CONTENTS
General .......................................................................................................................................... 3
Installation .................................................................................................................................... 3
Operation ...................................................................................................................................... 8
Batch, Total, & Rate Displays .................................................................................................... 11
Alarms ........................................................................................................................................... 12
Programming ................................................................................................................................ 13
Advanced Programming .............................................................................................................. 16
Calibration Mode .......................................................................................................................... 18
Maintenance Mode ....................................................................................................................... 20
Zero Crossing Parameter ............................................................................................................. 21
Troubleshooting ............................................................................................................................ 22
Tables ............................................................................................................................................. 24
Parts Lists & Drawings ................................................................................................................ 27
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
3
GENERAL
The Pfening Mark II is the most advanced and reliable flow meter available on the market today. The
meter itself has a rugged, precision cast bronze housing with a synthetic polymer metering chamber
with only two moving parts.
Water flows through the meter's strainer and into the metering chamber where it drives the piston,
which oscillates around the central hub. The piston rotates the drive dog and magnet. An electronic
Hall Effect switch detects the motion of the magnet and generates pulses which are sent to the Model
K2 Controller. Each pulse represents a fraction of a pound of water. The controller keeps a running
total of pounds of water and displays the total as a whole number. When the preset total is reached, the
controller automatically closes the flow solenoid valve, stopping the flow of water.
The Model K2 liquid meter controller is a microprocessor-based unit that uses the latest electronic
hardware and software developments to provide user-friendly, accurate, and reliable control. It uses
advanced logic to provide manual and pre-set setpoints, which are easy to access and adjust. The
Model K2 controller includes sophisticated control logic to provide fully automatic water temperature
control in conjunction with the optional Pfening Automatic Temperature Blender.
Manual temperature blender assemblies are also available for this flow meter. Manual temperature
blending is achieved with either a two-way or three-way manual blender. Each blender has a
thermometer and a bypass valve so that water can be run to set the temperature before water is run
through the meter to the mixer. A different service manual is provided with automatic blenders.
INSTALLATION
Install your new meter assembly in accordance with Figure 1, 2, or 3, whichever applies. Wire the
controller and solenoid valve in accordance with Figures 4 and 5. Mount the Model K2 Controller box
in a place convenient for the operator, avoiding excessively wet locations. The Model K2 controller
can be mounted remotely, up to 100’ from the water meter. Also avoid locations subject to vibration,
such as the side of a mixer. Also, observe the following information for any of these installations:
1. Use a receptacle (120 volt single phase) of the grounding type and ground properly before using
the meter.
2. Water is to flow through the meter and solenoid valve in one direction only. A cast arrow
indicates flow direction. Mount the meter and solenoid valve in a horizontal line with the head
of the meter and the head of the solenoid valve upright as shown in the figures.
3. A strainer with 30 mesh (.02” screens opening) ahead of the meter is recommended. This
protects the meter and solenoid valve from foreign particles. If a three-way blender is being
used, a separate strainer will not be necessary as this blender has a built in strainer.
4. If a blender is being used, place a check valve in each of the lower pressure water lines (usually
the hot water and/or ice water lines). This is to prevent water from the highest pressure line
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
4
backing up into the lower pressure lines. To secure accurate blending results, all water supplies
should be within 10 psi of the same pressure when the water is flowing through the meter.
Pressure regulators in each line or a booster pump on the lowest pressure line may be necessary
if there is a wide pressure differential between the lines. You can tell if you have balanced
pressure by checking the rate of water flow from each line individually through the meter.
When the rates are the same, the pressures are balanced.
5. The maximum static pressure to which the meter is to be exposed is 100 psi. The flow rate
should be not less than 100 lbs. of water per minute and not more than 200 lbs. per minute, (11
to 25 gals. per minute). Water temperature may be from 32 ºF to 150 ºF.
6. It is recommended that 1" pipelines be used before and after the meter. A larger size may be
necessary if the run is long or complicated by many valves or elbows. If the pressure drop is not
sufficient to restrict the flow to less than 200 lbs. of water per minute, a regulator must be
placed in the line ahead of the meter. If a blender is being used, it will be necessary to have a
regulator in each inlet line to the blender, which can produce in excess of 200 lbs. of water per
minute. A pressure drop restricting the flow to less than 100 lbs. of water per minute indicates
an inadequate pipe size. See Table 1, “Piping & Pressure Calculations,” further on in this
booklet, which shows how to estimate your pressure losses and flow rates before making the
installation.
FIG. 1 MARK II METER ONLY
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
5
FIG. 2 MARK II METER & 2-WAY MANUAL BLENDER
FIG. 3 MARK II WITH 3-WAY MANUAL BLENDER
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
6
FIG. 4 CABLE IDENTIFICATION
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
7
FIG
. 5 W
IRIN
G D
IAG
RA
M
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
8
OPERATION
The auto blender assembly is equipped with a Model K2 controller, which has been programmed and
calibrated at the factory. A non-volatile memory ensures that program settings will not be lost if power
is interrupted. The display has four lines of text; the top two lines usually display operating information
while the bottom two lines display operator instructions.
FIG. 6 KEYPAD AND DISPLAY
The controller settings may be changed by the operator. Figure 6 shows the operator keypad and
display. See pages 13-20 for programming and calibration procedures.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
9
Powering Up the Controller
When the Model K2 controller is first powered up, the display will show:
PFENING K2 V1.01
MARKII: WATER-LB
The top line shows the software version and the second line shows a summary of the current
programming.
Running a Manual Batch
Once the autoblender assembly and Model K2 controller are installed and power is applied, then display
should appear as shown:
ACTUAL 0 LB
MANUAL 60 LB
Push START to run
The actual amount of the last batch is displayed on the top line. The second line shows the manual
setpoint. In this example the manual setpoint is 60 lbs. of water.
To program a batch amount, simply enter the amount using the number keys. If you make a mistake,
press CLEAR and start over. If you entered a setpoint of 125 LB, the display will look like this:
ACTUAL 0 LB
MANUAL 125 LB
Push ENTER to save,
CLEAR for old value.
Press ENTER when the amount is correct or press CLEAR to bring back the previous value. The unit
will automatically save after five seconds. After the setpoint is saved the display will appear as shown:
ACTUAL 0 LB
MANUAL 125 LB
Push START to run
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
10
To run the batch, press START and the display will show:
ACTUAL 0 LB
MANUAL 125 LB
BATCH STARTED
Push STOP to abort
The actual amount of water delivered is shown on the top line. When the actual amount reaches the
preset amount, the flow solenoid valve will close.
Press START again to run additional batches of the same size.
Stopping a Batch
Press STOP at any time to stop a batch. If you stopped a batch at 66 lbs, the display would appear as
shown:
ACTUAL 66 LB
MANUAL 125 LB
BATCH STOPPED
Push START to run
Pressing START will restart the batch where it left off. Pressing CLEAR will reset it to zero.
Using the Presets
The controller will store up to five setpoints. Press the PRESET key to see SETPT1. Press PRESET
again to see SETPT2. Press PRESET a third time to see SETPT3, and so on. To run a batch using a
preset, simply press PRESET until the correct setpoint is shown. For example, if you want to run
SETPT2, which is 45 LB, the display would appear as shown:
ACTUAL 0 LB
SETPT2 45 LB
Push NO for new
Value, START to run
See below for directions about how to change the presets. After five seconds the display will revert to:
ACTUAL 0 LB
SETPT2 45 LB
Push START to run
To run the batch, press START.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
11
Changing the Presets
To change the preset weight, press NO. The display will show:
ENTER AMOUNT
SETPT2 67 LB
Push ENTER to save,
CLEAR for old value.
Use the number keys to enter the desired water amount, then press ENTER. Press CLEAR to go back
to the old value. The unit will automatically save after five seconds.
BATCH, TOTAL, AND RATE DISPLAYS
To see the total number of batches ran, press TOTALS. The display will appear as shown:
BATCH COUNT
44 BATCH
Push CLEAR to reset
This display says that 44 batches have been run since the last time the count was reset to zero. The
display will revert back to the normal display in three seconds. To reset the batch count to zero, hold in
the CLEAR button for three seconds. The batch count will flash 3 times and then reset.
Press TOTALS a second time to see the total amount of liquid ran. The display will appear as shown:
TOTAL AMOUNT
1278 LBS
Push CLEAR to reset
This display says that 1278 lbs. of liquid have been run since the last time the count was reset to zero.
To reset the total amount, hold in the CLEAR button for three seconds. The total amount will flash 3
times and then reset.
To see the rate, at which liquid is flowing through the meter, press TOTALS while the liquid is flowing.
The display will appear as shown:
FLOW RATE
166 LB/MIN
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
12
This says that the rate of liquid flow is 166 lbs. per minute. This display will read zero if no liquid is
flowing.
ALARMS
If the START button is pressed, but the controller receives no count input for seven seconds, the
solenoid is automatically closed and the display shows:
NO FLOW DETECTED
SETPT2 45 LB
Automatic Shutoff
Push CLEAR to reset
This is intended to prevent overfilling of the mixer when the valve is open, but no pulses are reaching
the controller. Correct the problem before attempting to run. See the troubleshooting section on page
22. Press CLEAR to reset the alarm.
If the actual count of liquid goes over the setpoint amount, the display will show:
ACTUAL 52 LB
SETPT2 45 LB
**OVERFLOW detected*
Push CLEAR to reset
Press CLEAR to reset the alarm. The display will show the actual amount of liquid delivered.
The overflow alarm will also be shown when pulses reach the controller when none should. For
instance, if the shutoff valve is leaking and water is dribbling through the meter, the overflow alarm
will be shown. Correct the problem and press CLEAR to clear the alarm.
If someone attempts to enter a zero setpoint, the zero setpoint alarm will come up, as follows:
ACTUAL 0 LB
MANUAL 0 LB
ZERO SETPOINT ERROR
Enter setpoint value
Use the number keys to enter a setpoint.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
13
PROGRAMMING
Current programming: Upon power-up, the controller screen looks like this for three seconds:
PFENING K2 V1.01
MARKII: WATER-LB
The upper line shows the software version number. The lower line shows a summary of the current
programming. In this example, the controller is programmed for a Mark II water meter, in lbs.
Controller programming: The controller has been programmed at the factory and reprogramming
should not be necessary. If you have a problem, work through the troubleshooting section on page 22
before changing the programming. If you suspect that the programming has been changed, the original
factory programming may be restored as described below.
Numeric code: To use this method, a six-digit number is created using Table 2 on page 25. Work
through this and write down the number. Then unplug the controller for 10 seconds, then hold in the 5
key, and plug the unit back in with the 5 key held in. The controller will show this:
Enter six digit
programming code:
0
Push ENTER when done
If you enter an invalid code, the screen will show:
CODE ERROR
Must be from 111111
to 433424. EXIT to
exit, CLEAR to retry
Program Mode
Programming is done through the keypad. To enter the program mode, first make sure the meter is
stopped (press STOP if necessary), then press the PROGRAM key. The display will show:
..PROGRAM MODE..
PASSWORD
To enter Program
Mode, enter PASSWORD
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
14
The password is 5354. Use the keyboard to enter the password. The numbers will not be displayed on
the screen. Press ENTER. If you enter the password wrong, it will ask you to try again. If you have
entered it correctly, the display will appear as shown:
..PROGRAM MODE..
PROGRAM UNIT
NO for choice,ENTER
to select, or EXIT
At this point you can continue into the program mode by pressing ENTER or else press NO for access
to the CALIBRATION MODE or MAINTENANCE MODE. Calibration and maintenance modes are
discussed on pages 18-20 respectively. Press ENTER to continue into the PROGRAM MODE.
..PROGRAM MODE..
SELECT UNITS LB
NO for choice,ENTER
to select, or EXIT
To leave the programming mode at any time, press EXIT. The controller will save any changes made
up to that point. To view the programming choices, press the NO key. In this case, the units can be LB
(pounds), KG (kilograms), LT (liters), or GA (gallons). When the correct units are displayed, press
ENTER to advance to the next step. The display will look like this.
..PROGRAM MODE..
SELECT DEC PT 000.0
NO for choice,ENTER
to select, or EXIT
Press NO to see the choices available, which is none, one, two, or three decimal places. Please note
that displaying more decimal places does not make the meter more accurate and may be misleading.
When the correct number of decimal point places is displayed, press ENTER to advance to the next
step. The display will look like this.
Note: If you want to go back, press PROGRAM to go back to the first step, press ENTER to go
forward.
..PROGRAM MODE..
SELECT LIQUID- WATER
NO for choice,ENTER
to select, or EXIT
Use the NO key to see the choices, which are water, oil, and sugar (liquid sugar). When one of these is
chosen, the controller will automatically adjust the scale factor for the density of the liquid being
metered. Press ENTER when the correct liquid is displayed. The display will go to the next step and
the display will look like this:
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
15
..PROGRAM MODE..
NO FLOW ALARM - ON
NO for choice,ENTER
to select, or EXIT
Use the NO key to turn the no flow alarm on or off. In general, we recommend that it be ON at all
times. The no flow alarm shuts off the liquid flow if no pulses are being received at the controller when
the valve is open. Press ENTER to advance to the next step and the display will look like this:
..PROGRAM MODE..
TEMPERATURE OFF
NO for choice,ENTER
to select, or EXIT
There are three possible settings for the temperature control: ON, OFF, and DISPLAY ONLY. This
setting should be set to OFF, unless you have a RTD temperature probe, in which case, set this setting
to DISPLAY ONLY. If you have an automatic temperature blender please refer to the automatic
temperature blender manual. If DISPLAY ONLY was chosen the unit will show:
..PROGRAM MODE..
SELECT TEMP UNITS_F
NO for choice,ENTER
to select, or EXIT
The units may be ºF or ºC. Press NO to make changes and ENTER to choose. The display will look
like this:
..PROGRAM MODE..
END BASIC PROGRAM?
Push ENTER to end,
NO for Adv Program
This screen allows you to either complete the basic unit programming or enter the advanced
programming section. The basic unit programming is all that most users will need. The advanced
programming section allows you to manually change the numeric values in the program. This should
only be attempted by qualified personnel.
To complete the basic programming, press ENTER. The screen will look like this.
..PROGRAM MODE..
SELECT METER-MARK II
NO for choice,ENTER
to select, or EXIT
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
16
Use the NO key to select which meter you have. A quick identification guide is:
Mark I has ¾” pipe connections and is natural brass finish
Mark II has 1” pipe connections and has a silver finish
Mark V has 1 ½” clamp connections and is stainless steel
HW (Hot Water) meter has clear plastic top.
Press ENTER when the display shows the correct meter. The controller will select the scale factor,
which is correct for your meter. The controller will save the data and after five seconds the display will
revert to the display that was present before entering the program mode.
ADVANCED PROGRAMMING
To enter the advanced programming mode, when the display shows:
..PROGRAM MODE..
END BASIC PROGRAM?
Push ENTER to end,
NO for Adv Progrom
Press NO and the display will change to:
..ADV PROGRAM MODE..
ADVANCED PROGRAM
ENTER for Adv Prog
EXIT to abort Prog
Press ENTER to enter the advanced programming mode. The display will look like this:
..ADV PROGRAM MODE..
SCALER 0.12890
Key in a new value.
The number 0.12890 is an example only; it may be different for your meter. See Table 3 on page 26 for
factory programmed values.
The SCALER is the amount of liquid metered for each change of state of the pickup switch in the water
flow meter. The controller counts both the rise and fall of each pulse, so there are two changes of state
for each pulse. Use the numeric keys to enter the scaler you wish. The maximum value of the scaler is
99.99999. If you are calibrating a meter, read the Calibration section on page 18. If you make a
mistake, key in zeroes until the display is cleared, then start over. When the correct value is displayed,
press ENTER to advance to the next step. The display will show:
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
17
..ADV PROGRAM MODE..
PREACT AUTO 0.520
NO for choice,ENTER
to select, or EXIT
The PREACT is the amount of liquid which passes through the valve between the time the coil is de-
energized and the when the valve actually closes. There are two methods available: a fixed value and
an automatic preact in which the controller continuously monitors the overshoot and uses 10% of the
overshoot to correct the preact for the next batch. Most users should choose the automatic preact. The
factory preact values are shown in Table 3 on page 26. To change the fixed preact, use the numeric
keys, then press ENTER.
To select the automatic preact, press NO then ENTER to advance to the next step. The display will
look like this:
..ADV PROGRAM MODE..
NO OF ACTIVE SETPT 6
NO for choice,ENTER
to select, or EXIT
The number of active setpoints may be from one to six. Press NO to change the number. If set at one,
only the MANUAL setpoint is available. If set at two, the MANUAL setpoint plus 1 PRESET is
available, and so so on. When set at six, the MANUAL setpoint plus all five PRESETS are active.
This feature is provided so that if only some of the PRESETS are in use, the others may be turned off so
they do not confuse the operator. Press ENTER when the display shows the correct number of presets.
The display will show:
..PROGRAM MODE..
PROGRAM UNIT
NO for choice,ENTER
to select, or EXIT
If you are finished programming, press EXIT and the display will show:
SAVING
PROGRAM IN MEMORY
Please wait!
The controller saves the data and reverts to the previous display.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
18
CALIBRATION MODE – AUTOMATIC CALIBRATION
Press the program button and after entering the PASSWORD (see page 14), the user may choose to
enter the CALIBRATION MODE. With the screen showing this:
..PROGRAM MODE..
PROGRAM UNIT
NO for choice,ENTER
to select, or EXIT
Press NO until the screen shows:
..PROGRAM MODE..
CALIBRATE UNIT
NO for choice,ENTER
to select, or EXIT
Press ENTER and the display will show:
..CALIBRATION MODE..
SCALER 0.12890
Push ENTER to cali-
brate, NO to skip.
The number 0.12890 is an example – your number may be different. Press ENTER to enter the
calibration mode and the unit will show:
..CALIBRATION MODE..
AMOUNT 0
Enter test amount to
run and press ENTER
Ideally, the flow meter will be calibrated at approximately the batch size most commonly used. If this
is impractical, we suggest a minimum calibration amount of 100 lbs. A container large enough to hold
the batch amount and a scale for weighing it are required. Water weights 8.35 lbs/gal. For example, if
you entered 100 lbs and pressed ENTER, the display will show:
..CALIBRATION MODE..
AMOUNT 100
Push START if catch
bucket in place.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
19
Press START and water will run until the test amount is metered out. The display will then show:
..CALIBRATION MODE..
ACTUAL 0
Weigh test amt, key
in wt, press ENTER
If the 100 lb test batch actually weighs 102 lbs, key in 102 and the display will show:
..CALIBRATION MODE..
ACTUAL 102
Weigh test amt, key
In Wt, press ENTER
Next, press ENTER and the controller will automatically calculate a new scaler and display as follows:
..CALIBRATION MODE..
OLD SCALER 0.12890
NEW SCALER 0.13148
Push ENTER to accept
Press ENTER to accept the new scaler, NO to revert to the old value. Press EXIT to exit setup.
Manual Calibration
The meter is factory calibrated and should require no adjustments for many years. However, should
calibration be necessary, the following procedure may be followed:
1. Obtain a scale and a container capable of holding at least 100 lbs. of water.
2. Weigh the empty container and record the weight.
3. Set the meter for 100 lbs. and run the water into the container. Allow the hose to drain.
4. Weigh the container and water, then subtract out the weight of the container.
5. Calculate an adjustment factor:
Actual Weight of water = Factor
100 lbs.
i.e. If actual Weight of water is 102 lbs, then 102 lbs. = 1.02
100 lbs.
6. Go to the programming section on pages 13-17. Follow the instructions (including entering
advanced programming) and find the scaler.
7. Multiply the scaler by the factor found above.
New Scaler = Old Scaler x factor
i.e. If the old scaler is 0.12890 and the factor is 1.02, then:
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
20
0.12890 x 1.02 = 0.13148
8. Enter the new scaler and press EXIT to return to the normal display.
9. Note: If the adjustment to the scaler is more than five percent, there is a serious problem with the
meter. See the “Not Metering Accurately” in the troubleshooting section on page 22.
MAINTENANCE MODE
After entering the PASSWORD (see page 14), the user may choose to enter the MAINTENANCE
MODE. With the screen showing this:
..PROGRAM MODE..
PROGRAM UNIT
NO for choice,ENTER
to select, or EXIT
Press NO until the screen shows:
..PROGRAM MODE..
MAINTENANCE MODE
NO for choice,ENTER
to select, or EXIT
Calibration is discussed on page 18. Press ENTER to continue into the MAINTENANCE MODE. The
screen will show:
----ACTUAL 0 LB
POT VOLTAGE 0.54
BLNDR POSITION 39
BLNDR SETTING=MANUAL
The displayed values are:
1. Top line: actual volume of liquid drawn.
2. Second line: position potentiometer voltage reading.
3. Third line: blender valve angular position.
4. Bottom line: blender valve setting – use NO to toggle between MANUAL, BLEND, HOT,
CITY and ICE.
(Note: Automatic blending unit is required for items 2 through 4. See automatic blender manual.)
Maintenance controls are provided to easily test the flow valve. Press START to open and STOP to
close.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
21
ZERO CROSSING PARAMETER
After entering the PASSWORD (see page 14), the user may choose to change the zero crossing
parameter. With the screen showing this:
..PROGRAM MODE..
PROGRAM UNIT
NO for choice,ENTER
to select, or EXIT
Press NO until the screen shows:
..PROGRAM MODE..
MAINTENANCE MODE
NO for choice,ENTER
to select, or EXIT
Press ENTER to continue into the MAINTENANCE MODE. The screen will show:
----ACTUAL 0 LB
POT VOLTAGE 0.54
BLNDR POSITION 39
BLNDR SETTING=MANUAL
Press ENTER to continue to change the zero crossing parameter. The screen will show:
ZERO CROSSING
TIME CONSTANT 4
ENTER VALUE 1 to 8
In order to reduce wear on the relay contacts, the controller attempts to operate the relay as the AC
voltage crosses zero (hence “zero crossing”). In order to do that, it must de-energize the coil 1 to 8
milliseconds early. The default value is 8 ms, but can be changed if necessary.
If you receive a zero crossing error at the end of the draw, change the time constant up or down 2 ms. If
this does not correct the zero crossing problem, the circuit board my need to be replaced.
CAUTION: Changing this to an erroneous value may cause the unit to stop working.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
22
TROUBLESHOOTING
Water runs, but there is no count:
Switch is loose: Open the top cover of the meter and make sure that the pick-up switch is tightly held
against the top of the meter casing by the retainer plate. Turn the retainer plate counter-clockwise to
tighten it down.
Switch wires loose or broken: Check that the wires from the controller to the switch are not broken or
loose.
Switch defective: To check for a defective switch, open the top cover of the meter and disconnect the
three wires. Touch the black and white wires together rapidly. The counter should count (the count
may be very erratic). This shows that the counter is working.
Another way to check switch operation is to remove the switch by turning the retainer plate clockwise.
Leave the wires hooked up. Find a small magnet (this must be a loose magnet, not one in a holder, such
as a screwdriver handle). Alternately touch the north and south poles of the magnet to the bottom
center of the aluminum switch housing. The controller will display 1 LB for about every eight touches
of the magnet.
If the switch appears to be defective, open up the controller and check the voltage between terminals 5
V and GND on the back of the controller. It should be 5 VDC. Next, check the voltage between
terminals 5V and FCNT. Take the magnet and touch the bottom of the switch, alternating the poles
with each touch. It should alternate between 0 and 4.5 VDC. If the switch is defective, install a new
one. See page 7 for wiring schematic.
Controller defective: If the controller does not count when the black and white wires are touched, check
the voltage between the red and black wires. It should be 5 VDC. If not, check the wires and check
that 5 VDC is present between terminals 5V and GND on the back of the controller. If voltage is
present, but the unit still does not count, touch a jumper wire between terminals 5V and FCNT. The
controller will display 1 LB for about every eight touches of the jumper. If the unit counts, the problem
is in the wiring, if not, the problem is in the controller. Replace the controller board. See page 7 for
wiring schematic.
Scale factor set near zero: If the meter has been re-calibrated in the field, it is possible for the scale
factor to be set very low, which will appear to not register. See page 13 for reprogramming.
Meter internals not moving: To check if the magnet inside the meter is turning when water is flowing,
remove the pickup switch by turning the retainer plate counter-clockwise. Get a paper clip and cut a ¼”
long piece of wire. Place this wire in the machined recess in the top of the meter housing where the
switch rests. The magnet inside will pull the wire into alignment with it. Now turn on the water. If the
magnet is turning, the wire will turn with it. If the wire is not turning, open the meter and determine
what is preventing rotation. Foreign matter in the meter is the most likely cause. If the meter internals
show considerable wear or scoring, replace the internals.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
23
The unit is plugged in and power is on, but nothing happens:
Wiring: Check that all wires on the back of the controller board are firmly connected.
Power: Check that 120VAC power is present at terminals L1 and L2 on the back of the controller.
Fuse: Check that the fuse on the circuit board is not blown. If it is, replace it with 2.0A, 250V fuse.
Controller: If power is supplied to the controller and the fuse is good, but the display is dark or
meaningless, the controller board should be replaced.
Solenoid valve: Check to see that the solenoid valve is receiving power when the START button is
pushed. If it is getting power but does not open, check the solenoid valve coil. See page 29 for
solenoid valve assembly diagram.
Not metering accurately:
Scale factor changed: If the liquid amount is off proportionately the same amount each time, the scale
factor may have been changed. See the programming section on page 13.
Meter internals worn: If the scale factor is correct, but a proportional error of more than 5% is present,
the meter internal parts may be worn, broken, or improperly installed. Disassemble the meter and
inspect. Reassembly should be done on a workbench.
Meter internals heat distorted: The standard meter internals are limited to 150 degrees F operation. If
water hotter than this is passed through the meter, the internal parts may become distorted, which will
prevent proper operation. Distortion generally causes the meter to run slow, resulting in too much
water.
If distortion is suspected, disassemble the meter and remove the metering chamber. The cylindrical
sides of the metering chamber should be straight. If a straightedge shows them to be concave, replace
the metering chamber. See page 28 for meter assembly diagram.
Additionally, the meter internals should turn freely. A small amount of air blown in the rectangular
inlet on the side of the metering chamber should spin the internals, making a characteristic “wuk-wuk-
wuk” sound.
Water won’t shut off at setpoint:
Solenoid Valve: If the solenoid valve remains open when de-energized, it is stuck open (rapping it will
sometimes make it close). Disassemble the valve and clean all the parts. If this does not fix the
problem, install a new valve or rebuild the existing one.
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
24
Temperature setting on the Blender is too sensitive. Small setting changes cause big temperature
changes:
This is generally the result of unbalanced water pressure in the lines. Run the unit with ice water only
and check the rate in pounds per minute. Run the unit with city water only and check its rate. For good
blender control, these rates should be about the same. This may be done with hot water providing it
isn’t more than 150 degrees F.
Pressure unbalance generally can be corrected by running a large pipe on the lower pressure line back to
its source or in the case of ice water increasing the pump pressure. Regulators can also be used to
reduce the higher pressure line’s flow rates to match the lowest pressure line, but be sure that the
resulting pressure doesn’t reduce the flow rate to less than 100 lbs. per minute through the meter and
solenoid valve.
Display is Dim:
Over time the display may grow dim and hard to read. This is adjustable. Turn off the power and
remove the front cover. The adjustment is a multi-turn potentiometer located on the back of the board,
on the right side, about a quarter of the way down from the top. It is labeled “DISPL ADJ”. Turn
counterclockwise to brighten the display.
Zero Crossing Error:
This means that the unit is missing the zero crossing. The default value is 8 ms. See page 25 for
explanation and setting. In general, this must be set for 7 or 8 ms. Other values may cause the unit to
stop working.
Piping & Pressure Calculations:
This section will be helpful in determining the pipe size to use or the rate of water flow with a given
pipe size.
The pressure drop in the line may be estimated from the following:
Rate of Water Flow Pressure Drop – PSI
Lbs/min
Gals./min
Mark II
Meter
2 Way
Blender
3 Way
Blender
Cut-Off
Sol. Valve
¾” Pipe
Per Ft.
1” Pipe
Per Ft.
1 ¼” Pipe
Per Ft.
100 12 1.3 1.0 2.0 2 0.19 0.06 0.015
150 18 3.2 2.4 3.5 4 0.40 0.12 0.032
200 24 6.3 4.5 6.0 7 0.70 0.20 0.055
250 30 9.0 6.7 9.0 11 1.0 0.30 0.082
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
25
Approximate equivalent lengths in feet of pipe for various fittings:
Fitting Pipe Size
¾” 1” 1 ¼”
Ball Valve 2 2.5 3
Globe Valve 22 27 38
Elbow 2.2 2.7 3.6
Tee 4.5 5.7 7.5
Table 1 – Piping & Pressure Calculations
Table 2 – Numeric Code
(See Page 13 to understand how to use this feature.)
For example, if you have a Mark II water meter, with a 1 decimal point weight accuracy displayed in
pounds. The code that should be entered is 121222.
Temp. Units
1 = ºC
2 = ºF
Volume Units 1 = LB
2 = KG
3 = LT
4 = GAL
Liquid Type
1 = Water
2 = Oil
3 = Sugar
Decimal Point
1 = None
2 = One
3 = Two
Temp. Control
1 = Off
2 = Display Only
3 = Control On
Meter Types
1 = Mark I
2 = Mark II
3 = Mark V
4 = Hot Water
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
26
FACTORY DEFAULT VALUES
Mark II Meter (Water Only) Units Pounds Gallons Liters Kilograms
Preact 0.520 0.062 0.236 0.236
Decimal Point None None None None
Scaler 0.12890 0.01544 0.05845 0.05845
Alarm On On On On
(These values are subject to change without notice.)
Table 3 – Factory Default Values
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
27
FIG. 7 MODEL K2 ASSEMBLY
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
28
FIG. 8 MARK II METER ASSEMBLY
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
29
FIG.9 1” SOLENOID VALVE ASSEMBLY
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
30
FIG.10 1” SOLENOID VALVE ASSEMBLY
PARK
ER VALVE
USED PRIOR
TO
MAY, 2009
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
31
FIG.11 1” MANUAL 2-WAY BLENDER ASSEMBLY
PFENING Mark II Water Meter With Model K2 Controller V1.06 MAY 2009
32
FIG.12 1” MANUAL 3-WAY BLENDER ASSEMBLY