21
Master Builders Green Living Conference
Transcript
  • Master Builders Green Living Conference

  • The All Electric House Of The Future STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 2

  • What is a heat pump? STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 3

  • The house of the future is available now – a case study STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 4

  • The house of the future is available now – a case study STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 5

    › Effects on self consumption case study › PV install: 15 kW PV peak, 15’000 to 17,000 kWh/year

    • No optimisation of system: 25 to 30 % • Programming Timers to noon: 40 to 45% • Software with predictive data: 50 to 55%

    • 55%+ when using car charging at home

  • Hydronic solution for the case study STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 6

  • Energy Management STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 7

    › So you have hydronic heating and solar PV… how do you get the most out of it?

    Nissan Leaf 2018 SBP700 Buffer Tank Tesla Powerwall 2

  • Energy Management STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 8

    1. Temperature raise 1 K, good thermal mass build, inslab heating 2. Hot water tank 300 l, 20 K raise 3. Hydronic buffer tank 1000 l, 30 K raise 4. Source: Origin energy 5. Example Nissan Leaf 2018

    Potential of energy storage Storage thermal Electrical capacity Extra cost AUD

    Building mass activation1 20 kWh 7 kWh -

    Buffer tank hydronic system3 35 kWh 14 kWh $2,000

    Battery4 0 kWh 13 kWh (Tesla Powerwall 2) $12,800

    Battery car5 0 kWh 40 kWh (average) From $35,000

  • You need a buffer…. STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 9

  • Family Business Stiebel Eltron Germany

  • A Company Full of Energy Since 1924 STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 11

  • Energy Campus in Germany STIEBEL ELTRON

    13

    Powered by three renewable energy sources: - Solar PV system - Geothermal heat pumps - Air source heat pumps

    DGNB platinum award by the German Sustainable Building Council

    EV Charging stations

  • Portfolio Hydronic Heat Pumps

  • Portfolio essentials STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 16

    WPL 25 A Airsourced Inverter Heatpump 14kW @ A7W35 COP A7W35: 5.09 EN14511 Cooling option available Single or 3 Phase 65°C max. 54 dB(A) Cascade up to 6 Units Outdoor Use

    WPF 16 Geothermal Heatpump 21.5 kW @ B10W35 COP B10W35: 5.67 EN14511 Cooling option available Single or 3 Phase 65°C max. 53 dB(A) Integrated Pumps Indoor use

    WPM Controllers Wall mounted Outdoor temperature guided Management of 2 mixed circuits Pool management available Solar management available

    Smart Home Solutions (2 Devices) ISG Web Integration and control via Internet or smartphone ISG Plus Integration and control via Internet or smartphone Energy management solution Solar PV/heat pump connection

    Buffer tanks From 100 to 1500 l Insulation up to 110 mm Designed for heat pumps Combi tanks for domestic hot water Cooling options available Solar options available Inside install only

  • Testing Testing and standards

  • Testing Heat Pumps STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 18

    › Most important test standards for Hydronic heat pumps:

    › HP Keymark New standardised test reports for a heat pump in the European market › DIN EN 14511 European test standards for heat pumps, A/C’s and chillers › EHPA seal of quality Going further than DIN EN14511. Defines minimal COP’s, measures

    efficiency and noise emissions within +/- 5% tolerance

  • Testing Heat Pumps STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 19

    › Impressions test facilities:

    Climatic chamber Air sourced heat pump (NTB Buchs)

    Sound emissions testing Domestic hot water heat pump

  • Noise emissions: Look beyond the data sheet! STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 20

    › Sound power vs sound pressure:

    • Sound power level (Lw) is measured dB to test standards in a sound lab.

    • Sound pressure level (Lp) is measured on site. Related to orientation, situation, distance and sound power level

    › Regularities and laws: • Both values can’t be directly compared without further information • Relations are logarithmical not linear • Duplicating the distance to the source reduces sound pressure level

    for 6 dB • 10 dB difference is perceived as double the noise • Using two identical units will be 3 dB louder than just one

  • Case study with real time data – what's possible today? STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 21

    335 m2 older House in Gembrook Victoria Retrofit solution with existing underfloor heating Installed new Air-sourced Inverter Heat pump. 200 l Buffer tank. Internet remote access. Domestic hot water separate. Data so far for 2018: Operating hours: 1,620 Average Room temperature 20°C Average Flow temperature Hydronic: 45°C Energy produced: 15,775 kWh Electrical consumption: 3,955 kWh COP: 4.0

    Pictures by Siddons Solar Hydronics

  • Case study: Real time data STIEBEL ELTRON

    Company Presentation STIEBEL ELTRON 22

    Outside temperature (blue) Flow temperature (green) Compressor speed (yellow)

    8:00 am 18.8.2018

    8:00 pm 18.8.2018

    8:00 am 19.8.2018

  • Legal notice | We are committed to our policy of continual improvement. Some features may have subsequently been changed or even removed. Our team will be happy to assist you regarding the currently applicable equipment features. The images used in this presentation are for reference only.

    Have we sparked your interest? For further information please visit www.stiebel.com.au or free call our customer service team on 1800 153 351

    Thank you for your attention!

    STIEBEL ELTRON Australia Pty Ltd | ABN 82 066 271 083

    Oliver Joss, Manager Renewable Technologies

    6 Prohasky Street 3207 Port Melbourne

    +61 3 9644 5023

    [email protected]

    Slide Number 1The All Electric House Of The FutureWhat is a heat pump?The house of the future is available now – a case studyThe house of the future is available now – a case studyHydronic solution for the case studyEnergy ManagementEnergy ManagementYou need a buffer….Slide Number 10A Company Full of Energy Since 1924Energy Campus in GermanySlide Number 15Portfolio essentialsSlide Number 17Testing Heat PumpsTesting Heat PumpsNoise emissions: Look beyond the data sheet!Case study with real time data – what's possible today?Case study: Real time dataSlide Number 23