Selecting the Right EquipmentA peristaltic pump uses positive displacement to transfer fluids within a flexible tube fitted inside a circular casing. A rotor (with a number of rollers attached) compresses the tube and as the rotor turns, the part of the tube under compression is pinched closed forcing the fluid to be pumped through the tube - this is known as ‘occlusion’.
This brochure contains an overview of the extensive range of Masterflex peristaltic pump systems.
To ensure you select the right equipment for your particular needs, follow these steps as a guide:
All Masterflex pumps conform to either ISO 9001:2008 or ISO 9001:2000 standards
To ensure you select the right peristaltic pumping system for your needs or for servicing your equipment, simply contact John Morris Scientific for professional advice.
Define Flow Rate
Select from relevant Pump Series
Solution/Product to be Pumped
Check the Tubing Type with tubing formulation to be pumped - refer table on page 3. Note: If options exist, refer Tubing Material Life Comparison chart to refine your selection (page 3)
Select Pump Drive, Pump Head & Tubing Size
Pump Drive Considertypeofhead,flowrate,fixed/variablespeed,numberofheads,etc)- selectfromrelevantPumpSeries
Pump Head ChoosethePumpHeadbasedonTubingFormulationsuitability (per Step 2) - select from relevant Pump Series
Tubing Size Basedonrequiredflowrate,selectthetubingsizetomeetyourneeds- selectfromrelevantPumpSeries
Flow Range Series Application Overview
Example
C/L
L/S
I/P
B/T
Combine low flow & compact size into a single pump
Fixed & variable speed with high-accuracy
Powerful & better protection from dust & water
Heavy duty & ideal in manufacturing
With a desired 900 mL/min flow rate, we have a choice of L/S or I/P Pump Series - we select L/S Series as it is the most popular & designed for lab use
We choose Acetone which, based on the Tubing Type table, offers CD (Chem-Durance Bio) or PFL (Gore Style 500) tubing formulation - we select CD tubing because it has a longer life & lower price
1
2
3
0.002 to 43 mL/min Compact/Low Flow
0.001 to 3,400 mL/min Lab/Standard
10 to 19,000 mL/min Industrial/Process
650 to 42,000 mL/min Batch/Transfer
Pump Head Tubing
Pump Drive
Based on L/S Series, we select Economy Console Pump Drive (600 rpm) as it satisfies flow rate, choice of variable speeds & is cheaper than I/P
As CD tubing formulation offers Easy Load or Easy Load II Pump Heads, we select Easy Load II as it has adjustable occlusion models
We select L/S 17 as it meets our flow rate requirements
2
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 552 724 Australia coleparmer.johnmorris.com.au
AcetaldehydeAcetate LMWAcetic acid <5%Acetic acid >5%Acetic anhydrideAcetoneAcetonitrileAcetyl bromideAcetyl chlorideAirAliphatic hydrocarbonsAluminium chlorideAluminium sulfateAlumsAmmonia, gas / liquidAmmonium acetateAmmonium carbonateAmmonium chlorideAmmonium hydroxideAmmonium nitrateAmmonium phosphateAmmonium sulfateAmyl acetateAmyl alcoholAmyl chlorideAnilineAniline hydrochlorideAqua regia 80% HCI, 20% HAromatic hydrocarbonsArsenic saltsBarium saltsBenzaldehydeBenzenesulfonic acidBleaching liquorsBoric acidBromineButaneButanol (butyl alcohol)Butyl acetateButyric acidCalcium oxideCalcium saltsCarbon bisulfideCarbon dioxideCarbon tetrachlorideChlorine, dryChlorine, wetChloroacetic acidChlorobenzeneChlorobromomethaneChloroformChlorosulfonic acidChromic acid, 30%Chromium saltsCopper saltsCresolCyclohexaneCyclohexanoneDiacetone alcoholDimethyl formamideDimethyl Sulfoxide (DMSO)Essential oilsEthanol (ethyl alcohol)EtherEthyl acetateEthyl bromideEthyl chlorideEthylamineEthylene chlorohydrinEthylene dichlorideEthylene glycolEthylene oxideFatty acidsFerric chlorideFerric sulfateFerrous chlorideFerrous sulfateFluoboric acidFluoroborate saltsFluosilicic acidFormaldehydeFormic acid, 25%Freon TMSGasoline, high-aromaticGasoline, nonaromaticGlucoseGlue, P.V.A.GlycerinHydriodic acidHydrobromic acid, 30%Hydrochloric acid (dil)Hydrochloric acid (med)Hydrochloric acid (conc)Hydrocyanic acidHydrocyanic acid, gas, 10%Hydrofluoric acid, 50%
Hydrofluoric acid, 75%Hydrogen peroxide (dil)Hydrogen peroxide, 90%Hypochlorous acidIodine solutionsIodoformKeroseneKetonesLacquer solventsLactic acid, 3–10%Lead acetateLinseed oilLithium hydroxideMagnesium chlorideMagnesium sulfateMalic acidManganese saltsMercury saltsMethaneMethanol (methyl alcohol)Methyl chlorideMethyl ethyl ketone (MEK)Mixed acid 40% H2SO4, 15% Molybdenum disulfideMonoethanolamineNaphthaNatural gasNickel saltsNitric acid (dil)Nitric acid (med)Nitric acid (conc)NitrobenzeneNitrogen oxidesNitrous acidOils, animalOils, mineralOils, vegetableOleic acidOxalic acid, coldOxygen, gasPalmitic acid, 100% in etherPerchloric acidPerchloroethylenePhenol (carbolic acid)Phosphoric acid, 50%Phthalic acidPlating solutionsPolyglycolPotassium carbonatePotassium chloratePotassium hydroxide (med)Potassium hydroxide (conc)Potassium iodidePropanol (propyl alcohol)PyridineSilicone fluidsSilicone oilsSilver nitrateSoap solutionsSodium bicarbonateSodium bisulfateSodium bisulfiteSodium borateSodium carbonateSodium chlorateSodium chlorideSodium ferrocyanideSodium hydrosulfiteSodium hydroxide (dil)Sodium hydroxide, 25%Sodium hydroxide (conc)Sodium hypochlorite, <5%Sodium hypochlorite, >5%Sodium nitrateSodium silicateSodium sulfideSodium sulfiteSteam, up to 40 psiStearic acidStyreneSulfuric acid (dil)Sulfuric acid (med)Sulfuric acid (conc)Sulfurous acidTannic acidTanning liquorsTartaric acidTin saltsToluene (toluol)Trichloroacetic acidTrichloroethyleneTrisodium phosphateTurpentineUreaUric acidWater, freshWater, saltXyleneZinc chloride
PN CF S T TU TC CD PFL V FPTubing Formulations Tubing FormulationsSolution/Product Solution/Product
Determine the right tubing formulation for your application using this compatibility table for all Masterflex tubing sizes. All ratings indicate tubing condition after exposure to the chemical at 21ᵒC.
The information in this brochure has been supplied by the manufacturer & is to be used as a guide only.
Whilst John Morris Scientific has taken every care to ensure the accuracy of information, no responsibility for errors or omissions is accepted.
Do not use L/S PTFE Tubing Pump Head with gases due to excessive heat build-up
Tubing FormulationsPN PharMed BPT, High-Pressure PharMed BPT, PharmaPure, Norprene, Norprene Food, PuriFlex CF C-FLEX & C-Flex UltraS Silicone (peroxide/ platinum-cured),BioPharm, BioPharm Plus, GORE Style 100SCT Tygon E-Lab, Tygon E-LFL, Tygon E-FoodTU Tygon Fuel & LubricantTC Tygon ChemicalCD Chem-Durance BioPFL GORE Style 500V Viton, GORE Style 400FP Polytetrafluoroethylene (PTFE)
Ratings Recommended for use
Not recommended (blank)
No data available
PN CF S T TU TC CD PFL V FP
10,000
1000
500
200
100
Aver
age
life
(hou
rs) @
50
rpm
Tygo
n® E-
Food
, E-L
ab
Vito
n®
C-FL
EX®
, Si
licon
e
Nor
pren
e®,
Phar
Med
® B
PT,
Phar
maP
ure®
10,000
Puri
-Fle
x™, C
-Fle
x® U
LTRA
5000
Tygo
n® E
-LFL
2500
500
300
150
Bio
Phar
m P
lus
silic
one,
Ch
em-D
uran
ce®
Bio
2000
10,000
1000
500
200
100
Average life (hours) @ 50 rpm
Tygon® E-Food, E-Lab
Viton®
C-FLEX®, Silicone
Norprene®, PharMed® BPT, PharmaPure®
10,000
Puri-Flex™, C-Flex® ULTRA
5000
Tygon® E-LFL
2500
500
300
150
BioPharm Plus silicone, Chem-Durance® Bio
2000
Tubing Type
Tubing Material Life Comparison
3
Toll Free: 0800 200 070 New Zealand coleparmer.johnmorris.co.nz
C/L Pump SeriesThe Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series. a. C/LPumpHeadSuitabilitywithTubingFormulations
c. C/L Pump Tubing Size
Masterflex provides a large range of C/L tubing to satisfy all requirements (internal diameters from 0.19 to 2.79 mm with a Flow Range from 0.002 to 43 mL/minute). Simply contact John Morris Scientific for further information.
b. C/L Pump Drives
Model Flow Rate per Channel (mL/
min)
RPM Number of Heads
Reversible Portable (12 VDC)
Size(cm)
Weight (kg)
Models
Flow Range
0.002 to 43 mL/min
Tubing Formulation Suitability Temp Range Advantages Limitations
Single Channel
0.002 - 43 Variable1.7 - 300 1
L: 17.8W: 8.9H: 8.9
1.4 6
0.002 - 12.3 Variable1.6 - 60
2L: 19.9W: 9.5H: 8.9
1.4 4
Dual Channel
C-Flex -40ᵒCto60ᵒC
PharMed BPT -20ᵒCto80ᵒC
Puri-Flex -30ᵒCto80ᵒC
Silicone (peroxide-cured) -40ᵒCto100ᵒC
Silicone (platinum-cured) -40ᵒCto100ᵒC
Tygon E-Lab (E-3603) 0ᵒCto40ᵒC
Tygon E-LFL 0ᵒCto40ᵒC
Viton 0ᵒCto150ᵒC
Physical properties similar to silicone with chemical compatibility of Tygon
Great for tissue & cell work - nontoxic & nonhemolytic
Biocompatible, heat sealable & weldable
Excellent biocompatibility
Excellent biocompatibility
Inexpensive tubing for general lab applications
Longest life of all Tygon peristaltic tubing
Perfect for food & lab applications (FDA compliant)
Not recommended for use with hydrocarbons
Potential leaching of USP mineral oil or blend material
Do not use with concentrated solvents, oils or acids
Do not use with concentrated solvents, oils or acids
Do not use with concentrated acids & bases, organic solvents or oils
Limited pumping life
Do not use with strong acids or alkalies
Limited pumping life
4
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 552 724 Australia coleparmer.johnmorris.com.au
L/S Pump SeriesThe Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series. a. L/SPumpHeadSuitabilitywithTubingFormulations
Tubing Formulation Standard Easy-Load IIEasy-Load Easy-Load 3
Temp Range
Advantages LimitationsPump HeadsMulti
ChannelCartridge
High Performance (Precision)
Flow Range
0.001 to 3,400 mL/min
BioPharm Plus Silicone (platinum-cured)
BioPharm Silicone (platinum-cured)
C-Flex
C-Flex ULTRA
Chem-Durance Bio
GORE Style 100SC
GORE Style 400
GORE Style 500
Norprene (A 60 G)
Norprene Food(A 60 F)
PharmaPure
PharMed BPT
PTFE
Puri-Flex
Silicone (peroxide-cured)
Silicone (platinum-cured)
Tygon Chemical (2001)
Tygon E-Food (B-44-4X)
Tygon E-Lab (E-3603)
Tygon E-LFL
Tygon Fuel & Lubricant (F-4040-A)
Viton
Similar to BioPharm Silicone plus longest life
of any silicone tubing
Ultra-smooth inner surface minimises
particle entrapment
FDA approval & excellent for food/dairy
Nontoxic & nonhemolytic(similar to PharMed BPT)
& biocompatible
Great for tissue & cell work - nontoxic &
nonhemolytic
Perfect for food & lab applications (FDA
compliant)
Longest life of all Tygon peristaltic tubing
Inexpensive tubing for general lab applications
Best chemical resistance of any Tygon formulation
Designed especially for handling food products
Designed especially for handling food products
Excellent biocompatibility
Specially formulated to transport hydrocarbons, petroleum products &
distillates
Chemically inert & excellent chemical
resistance
Biocompatible & heat sealable & weldable
Best choice for vacuum/pressure applications
Similar to STA-PURE PCS tubing but with enhanced
chemical resistance
Properties similar to silicone with chemical compatibility of Tygon
Properties similar to silicone with chemical compatibility of Tygon
Excellent chemical resistance & durability
Long life (even up to 4 bar pressure) & excellent
flow stability
Long life under pressure
-40ᵒC to 100ᵒC
-40ᵒC to 100ᵒC
-40ᵒC to 60ᵒC
-40ᵒC to 80ᵒC
0ᵒC to 40ᵒC
-40ᵒC to 150ᵒC
0ᵒC to 150ᵒC
-40ᵒC to 150ᵒC
-20ᵒC to 80ᵒC
-20ᵒC to 80ᵒC
-20ᵒC to 80ᵒC
-20ᵒC to 80ᵒC
-40ᵒC to 150ᵒC
-30ᵒC to 80ᵒC
-40ᵒC to 100ᵒC
-40ᵒC to 100ᵒC
0ᵒC to 40ᵒC
0ᵒC to 40ᵒC
0ᵒC to 40ᵒC
0ᵒC to 40ᵒC
0ᵒC to 40ᵒC
0ᵒC to 150ᵒC
--
-
- -
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
--
Do not use with concentrated
solvents, oils or acids
Do not use with concentrated solvents,
oils or acids
Potential leaching of USP mineral
oil or blend material
Potential leaching of USP mineral oil or
blend material
Potential leaching of USP mineral oil or
blend material
Do not use with concentrated acids & basis,
organic solvents or oils
Do not use with strong acids or alkalies
Limited pumping life
Limited pumping life
Limited pumping life
Do not use with strong acids or alkalies
Limited pumping life & sold as tube elements
onlyDo not use with
concentrated solvents, oils or acids
Do not use with concentrated solvents,
oils or acids
Potential leaching of USP mineral
oil or blend material
Sold as tube elements only
Not recommended for use with hydrocarbons
Not recommended for use with hydrocarbons
Requires high starting torque
Sold as tube elements only
Does not meet either USP or FDAclassifications
Limited pumping life
5
Toll Free: 0800 200 070 New Zealand coleparmer.johnmorris.co.nz
b. L/S Pump Drives
Type Model Flow Rate per Channel
(mL/min)
RPM Number of Heads
Reversible Portable (12 VDC)
Size(cm)
Weight (kg)
Models
Fixed Speed 0.06 - 290 1 or 2L: 15.2
W: 13.4H: 11.9
L: 28.0W: 34.3H: 44.4
L: 13.6W: 13.3H: 11.4
L: 27.9W: 16.5H: 22.2
L: 27.4W: 21.2H: 21.6
L: 25.1W: 12.2H: 22.4
L: 27.7W: 9.7H: 11.7
L: 30.5W: 22.9H: 23.6
L: 16.5W: 13.3H: 11.4
L: 21.6W: 9.7H: 11.7
L: 22.9W: 18.1H: 13.3
L: 27.4W: 21.2H: 21.6
L: 22.7W: 9.7H: 12.0
L: 27.9W: 25.4H: 40.6
L: 27.4W: 21.2H: 21.6
L: 31.7W: 23.4H: 18.3
72.9Fixed
1, 2, 6, 12, 20, 30, 60
Variable60 - 600
Variable1 - 1006 - 600
Variable35 - 200
Variable20 - 90
100 - 500
Fixed600
Variable0.02 - 1000.1 - 600
Variable0.1 - 600
Variable20 - 100
Variable70 - 400
Variable0.02 - 1000.1 - 600
Variable7 - 200
20 - 600
Variable1 - 1003 - 3006 - 600
Fixed100, 540, 570
Variable0.1 - 600
Variable6 - 600
Economy Console 0.42 - 2,900 1 or 2 23.7
Samplers - Composite 1,650 1 110.9
Precision Modular 0.06 - 3,400 2 or 4 47.1
Compact 0.8 - 105 1 or 2 22.7
Air-Powered 3.6 - 3,400 2 16.0
DC Powered - Compact
6 - 2,700 1 or 2 44.1
Modular Dispensers 0.006 - 3,400 2 27.1
Digital Standard 0.001 - 3,400 2 or 4 25.9
Stackable 2.1 - 560 1 21.7
Samplers - Portable 4.2 - 1,100 1 18.7
Precision Console 0.06 - 3,400 2 or 4 36.9
Digi-Staltic Dispenser 0.72 - 5,800 2 213.7
DC Powered - Cabinet-Style 1.2 - 2,400 1 or 2 25.3
Digital Process 0.006 - 3,400 2 111.8
Computer Compatible 0.001 - 3,400 2 or 4 25.9
- -
-
-
-
-
-
-
-
-
-
-
Analog
Speciality
Digital
6
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 552 724 Australia coleparmer.johnmorris.com.au
c. L/S Pump Heads
d. L/S Pump Tubing Size
Masterflex provides a large range of L/S tubing to satisfy all requirements (internal diameters from 0.8 to 9.7 mm with a Flow Range from 0.001 to 3,400 mL/minute) - refer page 11 for pump tubing size guide. Simply contact John Morris Scientific for further information.
Select the appropriate pump head to complement your pumping requirements and pump features
Type RPM (max)
Flow Rate(mL/min)
Stackable Multi Channel
MultiChannel
Features Models
Low cost, high precision & accuracy. Best choice for dispensing applications. One
head accepts one tubing size
Precise repeatable
fluid transferUp to 4 Heads 25-
-
-
-
--
--
-
Up to 32 Channels
--
8
4
1
8
4
2
6
2
Easy tubing changesUp to 4 Heads
Reduced pulsationUp to 4 Heads
Mount & stack heads without
toolsUp to 4 Heads
Up to 4 Heads
1 to 12 Channels
Synchronous flow rates
Highest pump head
flow rate
For PTFE tubing
Low pulsation
Aggressive fluids10 - 800
0.00005 - 2,300
4mm OD Tubing
0.001 - 17
6mm OD Tubing
0.005 - 65
0.006 - 3,400
0.00001 - 1,700
0.001 - 2,900
0.001 - 2,900
0.001 - 2,300
0.001 - 2,900 600
600
600
600
600
600
300
600
400
Same as Easy-Load (above) but with automatic tubing retention & higher flow
rates. Models with adjustableocclusion
Synchronous flow rates from each channel. Cartridges snap in/out quickly for
multichannel applications
Rigid PTFE tubing is the only wetted part. Pressure capability to 6.9 bar (100 psi)
PTFE & borosilicate glass are the only wetted parts. Excellent for metering.
Pressure capability to 6.9 bar (100 psi)
Very fast tubing changes. One head accepts many tubing sizes. Change tubing without
dismounting pump head from drive
Easiest tubing changes with automatic retention, same side tubing entry/exit. Mount & stack heads without tools or
hardware
Accepts all high-performance precision tubing sizes. Offers highest flow rate of any L/S pump head. Tubing enters & exits same
side of pump head
Synchronous flow from up to 32 channels without cartridges. Two-stop tubing sets are
easy to load with no adjustment needed
Standard
Easy- Load II
Multi Channel Cartridge
PTFE Tubing
Easy-Load
Easy-Load 3
High Performance
Multi Channel
PTFE Diaphragm
7
Toll Free: 0800 200 070 New Zealand coleparmer.johnmorris.co.nz
Tubing Formulation
Pump Heads Temp Range
Advantages Limitations
Standard Easy-LoadHigh
Performance
I/P Pump SeriesThe Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series. a. I/PPumpHeadSuitabilitywithTubingFormulations
BioPharm Plus Silicone (platinum-cured)
Similar to BioPharm Silicone plus longest life of any silicone tubing
Similar to STA-PURE PCS tubing but with enhanced chemical resistance
Excellent biocompatibility
Ultra-smooth inner surface minimises particle entrapment
Best choice for vacuum/pressureapplications
Excellent biocompatibility
Physical properties similar to silicone with chemical compatibility of Tygon
FDA approval & excellent for food/dairy
Best chemical resistance of any Tygon formulation
Physical properties similar to silicone with chemical compatibility of Tygon
Nontoxic & nonhemolytic(similar to PharMed BPT) &
biocompatible
Designed especially for handling food products
Excellent chemical resistance & durability
Great for tissue & cell work - nontoxic & nonhemolytic
Inexpensive tubing for general lab applications
Long life (even under pressures up to 4 bar) & excellent flow stability
Chemically inert & excellent chemical resistance
Longest life of all Tygon peristaltic tubing
Long life under pressure
Biocompatible & heat sealable & weldable
Specially formulated to transport hydrocarbons, petroleum products
& distillates
Perfect for food & lab applications (FDA compliant)
Do not use with concentratedsolvents, oils or acids
Sold as tube elements only
Do not use with concentrated solvents, oils or acids
Do not use with concentrated solvents, oils or acids
Potential leaching of USP mineraloil or blend material
Do not use with concentrated acids & bases, organic solvents or oils
Not recommended for use with hydrocarbons
Potential leaching of USP mineraloil or blend material
Limited pumping life
Not recommended for use with hydrocarbons
Potential leaching of USP mineral oil or blend material
Limited pumping life
Requires high starting torque
Potential leaching of USP mineral oil or blend material
Limited pumping life
Sold as tube elements only
Limited pumping life & sold as tube elements only
Do not use with strong acids or alkalies
Does not meet either USP or FDA classifications
Do not use with concentrated solvents, oils or acids
Do not use with strong acids or alkalies
Limited pumping life
BioPharm Silicone (platinum-cured)
C-Flex
C-Flex ULTRA
Chem-Durance Bio
GORE Style 100SC
GORE Style 400
GORE Style 500
Norprene (A 60 G)
Norprene Food(A 60 F)
PharmaPure
Tygon Chemical (2001)
Tygon Fuel & Lubricant (F-4040-A)
Viton
PharMed BPT
PTFE
Puri-Flex
Tygon E-Food (B-44-4X)
Silicone (peroxide-cured)
Tygon E-Lab (E-3603)
Silicone (platinum-cured)
Tygon E-LFL
-40ᵒC to 100ᵒC
-40ᵒC to 100ᵒC
-40ᵒC to 60ᵒC
-40ᵒC to 80ᵒC
0ᵒC to 40ᵒC
-40ᵒC to 150ᵒC
0ᵒC to 150ᵒC
-40ᵒC to 150ᵒC
-40ᵒC to 100ᵒC
-20ᵒC to 80ᵒC
-40ᵒC to 100ᵒC
-20ᵒC to 80ᵒC
0ᵒC to 40ᵒC
-20ᵒC to 80ᵒC
0ᵒC to 40ᵒC
-20ᵒC to 80ᵒC
0ᵒC to 40ᵒC
-40ᵒC to 150ᵒC
0ᵒC to 40ᵒC
-30ᵒC to 80ᵒC
0ᵒC to 40ᵒC
0ᵒC to 150ᵒC
-
-
-
-
- -
Flow Range
10 to 19,000 mL/min
8
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 552 724 Australia coleparmer.johnmorris.com.au
Type Flow Rate(mL/min)
RPM (max)
Stackable Multi Channel
Usage ModelsFeatures
6
2
10 - 13,000 650Up to
2 HeadsPrecise
repeatable fluid transfer
Yes
10 - 19,000 650
410 - 13,000 650 Up to 2 Heads
Easy tubing changes
Highest pump head flow rate
Yes
--
Standard
High Performance
Easy-Load
b. I/P Pump Drives
c. I/P Pump Heads
Select the appropriate pump head to complement your pumping requirements and pump features
d. I/P Pump Tubing Size
Masterflex provides a large range of I/P tubing to satisfy all requirements (internal diameters from 6.4 to 15.88 mm & Flow Range from 10 to 19,000 mL/minute) - refer page 11 for pump tubing size guide.
Simply contact John Morris Scientific for further information.
Low cost, high precision & accuracy. Best choice for dispensing applications.
One head accepts one tubing size
Quick tubing changes. One head accepts several tubing sizes. Change
tubing without dismounting pump head from drive. Model available for ATEX
Zone 2 applications.
Accepts all high-performance precision tubing sizes. Offers highest flow rate
of any I/P pump head. Tubing enters & exits same side of pump head. Model available for ATEX Zone 2 applications.
Type Model Flow Rate per Channel
(mL/min)RPM Number of
HeadsReversible Weight
(kg)ModelsSize
(cm)
Variable6 - 650
Variable0.1 - 650
Fixed83, 100, 450, 540
Flow rates and features are dependent upon motor selection(contact John Morris Scientific for more details)
2
2
4
9.9
18.1
19.0
2
2
2
36.0 - 19,000
0.6 - 19,000
500 - 14,100
1
2
1
10.0
12.6
9.6-
2
2
2
200 - 19,000
0.6 - 19,000
600 - 19,000
Variable33 - 650
Variable0.1 - 650
Variable100 - 650
Modular
Digital Process
Fixed Speed & Multi Channel
Brushless Process
Modular Dispensing
Air Powered
Pump Head Adaptors
Digital
Speciality
L: 35.3W: 13.9H: 15.6
L: 35.0W: 25.0H: 23.0
L: 36.2W: 17.8H: 16.5
L: 42.3W: 28.3H: 32.8
L: 28.2W: 21.6H: 22.9
L: 43.0W: 27.6H: 26.1
9
Toll Free: 0800 200 070 New Zealand coleparmer.johnmorris.co.nz
Tubing Formulation Suitability Temp Range Advantages Limitations
-40ᵒC to 100ᵒC
-30ᵒC to 80ᵒC
0ᵒC to 150ᵒC
0ᵒC to 40ᵒC
-40ᵒC to 60ᵒC
-40ᵒC to 100ᵒC
-20ᵒC to 80ᵒC
0ᵒC to 40ᵒC
0ᵒC to 40ᵒC
-40ᵒC to 100ᵒC
-20ᵒC to 80ᵒC
-40ᵒC to 150ᵒC
0ᵒC to 40ᵒC
-20ᵒC to 80ᵒC
BioPharm Plus Silicone (platinum-cured)
C-Flex
GORE Style 100SC
Norprene (A 60 G)
PharMed BPT
Silicone (peroxide-cured)
Tygon E-Food (B-44-4X)
Chem-Durance Bio
GORE Style 400
PharmaPure
Puri-Flex
Silicone (platinum-cured)
Tygon E-Lab (E-3603)
Tygon E-LFL
Similar to BioPharm Silicone plus longest life of any silicone tubing
Physical properties similar to silicone with chemical compatibility of Tygon
Excellent chemical resistance and durability
Long life (even under pressures up to 4 bar) & excellent flow stability
Long life under pressure
Best choice for vacuum/pressureapplications
Nontoxic & nonhemolytic(similar to PharMed BPT) & biocompatible
Great for tissue & cell work - nontoxic & nonhemolytic
Biocompatible & heat sealable & weldable
Excellent biocompatibility
Excellent biocompatibility
Designed especially for handling food products
Inexpensive tubing for general lab applications
Longest life of all Tygon peristaltic tubing
Do not use with concentratedsolvents, oils or acids
Not recommended for use with hydrocarbons
Requires high starting torque
Sold as tube elements only
Does not meet either USP or FDAclassifications
Potential leaching of USP mineraloil or blend material
Potential leaching of USP mineral oil or blend material
Potential leaching of USP mineral oil or blend material
Do not use with concentrated solvents, oils or acids
Do not use with concentrated solvents, oils or acids
Do not use with concentrated acids & bases, organic solvents or oils
Limited pumping life
Limited pumping life
Do not use with strong acids or alkalies
The Pump Drive, Pump Head and Tubing Size must be selected from the same Pump Series. a. B/TPumpHeadSuitabilitywithTubingFormulations
B/T Pump Series
ModelType ModelsWeight (kg)Size(cm)
ReversibleNumber of Heads
RPMFlow Rate per Channel
(mL/min)
1
1
4
35,000 Fixed271 1
L: 68.6W: 40.0H: 38.4
L: 68.6W: 40.0H: 42.4
L: 68.6W: 40.0H: 38.4
L: 68.6W: 40.0H: 42.4
L: 68.6W: 40.0H: 38.4
40.4
39.9
650 - 42,000
2,100 - 42,000
Variable11 - 321
Variable35 - 321
1
1
710 - 42,000Variable12 - 321 1
28.5Flow rates & features are dependent upon motor selection (contact John Morris Scientific for more details)
40.4
44.71
1 -
Fixed Speed*
Modular Dispensing*
Air-Powered*
Rapid Load Pump Heads
Variable Speed*
b. B/T Pump Heads & DrivesSelect the appropriate pump head to complement your pumping requirements and pump features
c. B/T Pump Tubing SizeMasterflex provides a large range of B/T tubing to satisfy all requirements (Internal Diameters from 12.7 to 19.0 mm and Flow Range from 650 to 42,000 mL/minute) - refer page 11 for pump tubing size guide. Simply contact John Morris Scientific for further information.
* Pump Head is included in each Pump Drive
Digital
Speciality
Analog
Flow Range
650 to 42,000 mL/min
10
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Free Call: 1800 552 724 Australia coleparmer.johnmorris.com.au
Pump Tubing Size Guide per Pump SeriesL/S Pump Tubing
I/P Pump Tubing
B/T Pump Tubing
Tubing Cross Section - Precision
Tubing Cross Section - Precision
Tubing Cross Section
Tubing Cross Section - High Performance
Tubing Cross Section - High Performance
Model Number
Model Number
Model Number
Model Number
Model Number
L/S 13
L/S 15 L/S 24 L/S 35 L/S 36
L/S 14 L/S 16 L/S 25 L/S 17 L/S 18
0.8mm
I/P 26
6.4mm
B/T 87
12.7mm
4.8mm 6.4mm 7.9mm 9.7mm
I/P 70
9.5mm
1.6mm 3.1mm
I/P 73
9.5mm
B/T 91
19.0mm
I/P 88
12.7mm
4.8mm 6.4mm
I/P 82
12.7mm
I/P 89
15.88mm
7.9mmInside Diameter
Inside Diameter
Inside Diameter
Inside Diameter
Inside Diameter
AccessoriesJohn Morris Scientific also offers an extensive range of Masterflex Peristaltic Pumping System accessories & spare parts.
Repairs & MaintenanceOur Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Masterflex Peristaltic Pumping Systems to ensure your equipment is operating to its optimum capacity.
To ensure you select the right peristaltic pumping system for your needs or for servicing your equipment, simply contact John Morris Scientific for professional advice.
11
Toll Free: 0800 200 070 New Zealand coleparmer.johnmorris.co.nz
Scientific
JohnMorris John Morris Scientific
Service plus SolutionsAustraliaAddress 61-63 Victoria Avenue Chatswood NSW 2067 AustraliaFree Call 1800 552 724Enquiries +61 (0) 2 9496 4200 Email [email protected] coleparmer.johnmorris.com.au
At John Morris Scientific we offer more than just the product - we provide the full package -
sales and servicing of instrumentation plus design tailored solutions to meet your needs.
We offer more than 'just the box'
SupportSalesSolutions Service
New ZealandAddress 78 Wellesley Street Auckland NZ 1010Toll Free 0800 200 070Enquiries +64 (0) 9 366 3999 Email [email protected] coleparmer.johnmorris.co.nz
For Over 50 Years