14
MAX SUPER ARM 2300 Moves heavy gates up to 20’ High-traffic, High-wind Self-locking, Mag Lock unnecessary Overload clutch release on 3-ton impact DSP Control 2 Year Warranty or 100,000 Cycles whichever comes first MAX AC control box UL 2018 THE NEW STANDARD
Transcript
Page 1: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

MAX SUPER ARM 2300

Moves heavy gates up to 20’High-traffic, High-wind

Self-locking, Mag Lock unnecessaryOverload clutch release on 3-ton impact

DSP Control

2 Year Warranty or 100,000 Cycleswhichever comes first

MAX ACcontrol box

UL 2018 THE NEW STANDARD

Page 2: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

MECHANICAL SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

• 24 Volt DC motor • Two independently adjustable closing speed controls with 16 positions each• Switchable 115/230 voltage selection• Adaptive DSP motor control for advanced motion control • Real time performance analyzer and event log (OBD PORT and Black Box)• Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft • On-board switch for solar mode enables 5 milliamp idle in sleep mode• Gold contact input connections and automobile grade connectors• -4F to 165F (-20C to +74C) operational range including battery backup without a heater

• Shipping weight of Actuator: Super Arm (35 lbs)• Shipping weight of AC Control Box (38 lbs)• The patented brake system allows the operator to retract with extreme force. When the force

exceeds 3 tons, the clutch releases upon impact, then automatically resets. Causes for clutch release include a vehicle strike while the gate is in motion.

• Stainless steel output shaft• Direct gear drive (no internal chains, belts, or pulleys)• Mechanical and electrical gate release functions• Continuous duty cycle at extreme temperature range. No overheating• Intelligent ramp-up and ramp-down for smooth gate operation

MAX SUPER ARM 2300 FEATURE LIST:

= Unique to Max Super Arm 2300

7.3”

Min = 37”

4.5”

9.25”

Max = 54.75”

control box13.5” 5.75”

17”JOG GATEOPEN / CLOSE

RESET ALARM

115VAC3A max

7AFUSE

POWER

On

Off

WARNING: For continued protection against fire, replace only with the

same type and rating of fuse.

AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d’incendie, utiliser un

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage115VAC or 230VAC

(AC)

POWER IN

115V

SAFETYCENTEREXITJ3

J2

J4 J5

EXIT PWR

ALARM

POWER /SOLAR IN

BATTERYINPUT

OPENING CLOSING

MOTOR 2MOTOR 1

ERD

OBD PORTBLACK BOX

PROGRAMMING

SOLAR MODE

MOTOROVERLOAD

ERDMOTOROVERLOAD MIN MAX

OFF

MAXSENSE

MAXSENSE

BATTERYBACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2LIMITS

MAGLOCK

ULENTRAP

STOP CLOSE

CLOSETIMER

MAGLOCKDELAY

JOG

BATTERYTEST

BATTERY

INPUTERROR

BATTERYIN USE

POWER

REPLACEBATTERY LEAVE

CLOSED

LEAVEOPEN

OPEN1 TIME

BATTERY VOLTAGEE F1/2

RESET

IDPLUG

MODULEPORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NCOPEN / CLS NC

GND12VDC OUT

GND

GND

GND

GND

GND

JOG C

LOSE

JOG O

PEN

TAMP

ER IN

TAMP

ER NO

GATE

DISAB

LE

KEYP

AD/CA

RD

GND

GND

MAX O

PEN

FIRE D

EPT

RADIO

GND

RADIO

SIGN

AL

STRIK

E

CLOS

ECO

M

COM

STOP

OPEN

PHOTO CLS 10KOPEN / CLS 10K

12VDC OUT

NOCOM

NC

COMGATE CLOSED

LIMIT 1GND

LIMIT 2

MOTOR 1LIMITS

MOTOR 1

MOTOR 2

LIMIT 1GND

LIMIT 2

LIMIT 1LIMIT 2LIMIT 1LIMIT 2

ID PLUGERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOPLOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFFBATTERY

CLOSE

DUAL

ON

ANTI-TAILGATE

PUSHOPEN

PULLOPEN

GATEOFF

123456789

10OFF

123456

MIN MIN

MAX MAX

ON

OFF 2.5 sec1.5 sec

FAULTSOPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16MIN

16MIN

3

1

14 12

9

7 3

1

14 12

9

7

UL SE

NSOR

10K

UL SE

NSOR

N.C.

MODE

AMO

DE B

PROGRAM

MOTOR 1INPUTS

[+][-]

[+][-]

MOTOR 2INPUTS

MAXIMUM CONTROLSDSP ARM CONTROLLER

8ft 12ft 16ft 20ft

2300

lbs

2000

lbs

1800

lbs

1500

lbs

Max Weight/Length

7.3”

Min = 37”

4.5”

9.25”

Max = 54.75”

control box13.5” 5.75”

17”JOG GATEOPEN / CLOSE

RESET ALARM

115VAC3A max

7AFUSE

POWER

On

Off

WARNING: For continued protection against fire, replace only with the

same type and rating of fuse.

AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d’incendie, utiliser un

fusible de mêmes type et caractéristiques nominales.

Select Input Voltage115VAC or 230VAC

(AC)

POWER IN

115V

SAFETYCENTEREXITJ3

J2

J4 J5

EXIT PWR

ALARM

POWER /SOLAR IN

BATTERYINPUT

OPENING CLOSING

MOTOR 2MOTOR 1

ERD

OBD PORTBLACK BOX

PROGRAMMING

SOLAR MODE

MOTOROVERLOAD

ERDMOTOROVERLOAD MIN MAX

OFF

MAXSENSE

MAXSENSE

BATTERYBACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2LIMITS

MAGLOCK

ULENTRAP

STOP CLOSE

CLOSETIMER

MAGLOCKDELAY

JOG

BATTERYTEST

BATTERY

INPUTERROR

BATTERYIN USE

POWER

REPLACEBATTERY LEAVE

CLOSED

LEAVEOPEN

OPEN1 TIME

BATTERY VOLTAGEE F1/2

RESET

IDPLUG

MODULEPORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NCOPEN / CLS NC

GND12VDC OUT

GND

GND

GND

GND

GND

JOG C

LOSE

JOG O

PEN

TAMP

ER IN

TAMP

ER NO

GATE

DISAB

LE

KEYP

AD/CA

RD

GND

GND

MAX O

PEN

FIRE D

EPT

RADIO

GND

RADIO

SIGN

AL

STRIK

E

CLOS

ECO

M

COM

STOP

OPEN

PHOTO CLS 10KOPEN / CLS 10K

12VDC OUT

NOCOM

NC

COMGATE CLOSED

LIMIT 1GND

LIMIT 2

MOTOR 1LIMITS

MOTOR 1

MOTOR 2

LIMIT 1GND

LIMIT 2

LIMIT 1LIMIT 2LIMIT 1LIMIT 2

ID PLUGERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOPLOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFFBATTERY

CLOSE

DUAL

ON

ANTI-TAILGATE

PUSHOPEN

PULLOPEN

GATEOFF

123456789

10OFF

123456

MIN MIN

MAX MAX

ON

OFF 2.5 sec1.5 sec

FAULTSOPERATOR

DSP ARM CONTROLLER

OFF

EXIT LOOP

16MIN

16MIN

3

1

14 12

9

7 3

1

14 12

9

7

UL SE

NSOR

10K

UL SE

NSOR

N.C.

MODE

AMO

DE B

PROGRAM

MOTOR 1INPUTS

[+][-]

[+][-]

MOTOR 2INPUTS

MAXIMUM CONTROLSDSP ARM CONTROLLER

8ft 12ft 16ft 20ft

2300

lbs

2000

lbs

1800

lbs

1500

lbs

Max Weight/Length

Gate Capacity

2

Page 3: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

SAFETY SPECIFICATIONS

• UL 325/991 compliant Class I, II, III, and IV. CSA approved• Vehicle hit protection technology protects the gate operator from collision damage caused by

automobile impact, avoiding costly repairs• Built in advanced entrapment protection and alarm output• Built in gate-in-motion alarm for industrial applications

• Robust lightning protection, up to 20KVolts and 10KAmps on all inputs and outputs (35 channels) including loop detector input connections

• Two selectable 16 position safety obstruction sensors, auto adaptable to gate weight and size, for independent control of open and close cycles

• Independent closing speeds for primary and secondary• Dual motor overcurrent safety shut off for additional protection• Two 7amp hour batteries provide 500 cycles in case of power failure with three modes of battery

backup, open once, leave open or leave closed• On-board three button station• On-board UL reset button

= Unique to Max Super Arm 2300

SECURITY SPECIFICATIONS

• High traffic intuitive loop management system for exceptional security• Advanced security features with built-in audible and remote alarms • Magnetic lock control relay outputs with selectable delay times• Tamper alert relay output triggers “on” if gate is forced open• Audible alarm if gate is tampered with or ERD is triggered for heightened security• Steel cover with lock protects against intruders and vandalism• Gate disable feature disables all inputs with exception of the fire department and Max Open input

for increased security • Built in transaction buffer• Gate status outputs for gate monitoring• Key activated jog function for emergency OPEN/CLOSE function• Advanced anti-tailgate feature prevents unwanted intrusion

3

Page 4: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the hood. To engage the actuator, push down the hood and lock to resume automatic operation.

The Max Super Arm 2300 ships with a heavy duty half inch stock rear bracket that is broached and welded. Both brackets front and rear, are silver zinc plated.

Front BracketRear Bracket

SUPER ARM 2300 MECHANICAL RELEASE

AND MOUNTING BRAKETS

4

Page 5: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

Maximum Controls recognizes swing gates are more prone to vehicular collisions. For this reason, the Max Super Arm 2300 will collapse on impact when struck by vehicular traffic. When a vehicle hits a moving gate, to avoid damage to the actuators, the Super Arm 2300 reset automatically.

VEHICLE HIT PROTECTION

PUSH OPEN

PULL OPENINSIDE PROPERTY

OUTSIDE PROPERTY

TWO INSTALLATION OPTIONS

OPEN

OPEN

CLOSED

CLOSED

5

Page 6: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

90° Open 75° Open

90° Open 75° Open

90° Open 75° Open

90° Open 75° Open

Opening one 90° and the other is 75°

with the independent closing speeds adjusted the closing gate leaves can be synced

ASYMMETRIC SPEED CONTROL

For asymmetric installations the two independent closing speeds can be adjusted to achieve a smooth closing sync. Whichever gate closes first, slow it down. This enables the installer to visually sync the closing cycle. This feature is unique to Maximum Control’s actuators.

6

Page 7: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

AC CONTROL BOX

Two 12V 7 AGM Batteries

UL Reset Button

Jog Open/CloseKey Switch for emergency access to property

Selectable Switch115V or 230V AC

7 ampFuse

ON and OFF Power Supply Switch

Two plugin power outlets

Loop RackSafety LoopCenter LoopExit Loop

Steel housing2- layer protection

Gold zinc Electrostatic

powder coating

Gold plated automobile connectorsthroughout the system

Control Panel

The AC Control Box features rugged metal construction that is gold zinc plated and powder coated. Each AC Control Box comes with an exterior UL reset button, a convenient jog key switch for emergency access or egress, a 10 amp power supply with two 115 VAC accessory outlets, two 7 amp batteries conveniently located behind the control panel, a loop rack and much more. A lockable steel cover finishes off this slick design.

A convenient LCD display keeps you informed. Functional data and error messages are visible when an accessory failure or function is present. This makes troubleshooting and monitoring a breeze.

These many features can be explored in our downloadable installation manual available on max.us.com

7

Page 8: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

MAX SOLAR CONTROL BOX

Two 12V 18 Agm Batteries

UL Reset Button

Jog Switch inputOPTIONAL

ON and OFF Power Supply Switch

30AFUSE

Loop RackOPTIONAL

Steel housing2-layer protection

Gold zinc Electrostatic

powder coating

Gold plated automobile connectors

through the system

Control Panel

Solar Regulator24V, 20A

(MORNING STAR)

Solar Regulator24V, 20A(MORNING STAR)

8

Page 9: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

1. Battery Input2. Power/Solar Input3. Module Port4. Reset

5. UL Alarm6. ID Plug7. Loop Rack Input8. 12VDC & 24VDC Limited Current Power Output

1. Battery Backup Mode Switch 2. Battery Test Switch3. ERD Sensitivity4. OBD Port5. DIP Switches6. Program Button7. Loop Status

8. Solar Mode Application9. Motion Control Buttons

10. Maglock Delay11. LCD Display12. Close Timer Switch13. Jog Open/Close14. Closing Gate Speed

87653 421

CONTROL FEATURES AND CONNECTIONS

12

113

4

5

6

7

8

9

12

10

14

13

9

Page 10: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

MAX SOLAR CONTROL BOX

Two 12V 18 AH (AGM Rechargable Batteries)

UL Reset Button

Jog SwitchOPTIONAL

30AFUSE

Loop RackOPTIONAL

Steel housing2-layer protection

Gold zinc Electrostatic

powder coating

Gold plated automobile connectors

through the system

SOLAR MODESwitch to enable low power draw for solar mode

Control Panel

Solar Regulator24V, 10A

(MORNING STAR)

Solar Regulator24V, 10A(MORNING STAR)

24V Solar PanelOutput: 36 V (Max) - Open Circuit

Wire solar panel terminals to solar regulator inputCaution: polarity matters EXIT PWR

ALARM

POWER /SOLAR IN

BATTERYINPUT

OPENING CLOSING

MOTOR 2MOTOR 1

ERD

OBD PORTBLACK BOX

PROGRAMMING

SOLAR MODE

MOTOROVERLOAD

ERD

MOTOROVERLOAD MIN MAX

OFF

MAXSENSE

MAXSENSE

BATTERYBACKUP MODE

ERD SENSITIVITY

MOTION CONTROL

OPEN

CLOSING GATE SPEED

MOTOR 2LIMITS

MAGLOCK

ULENTRAP

STOP CLOSE

CLOSETIMER

MAGLOCKDELAY

JOG

BATTERYTEST

BATTERY

INPUTERROR

BATTERYIN USE

POWER

REPLACEBATTERY

LEAVECLOSED

LEAVEOPEN

OPEN1 TIME

BATTERY VOLTAGEF1/2E

RESET

IDPLUG

MODULEPORT

GATE OPEN

GND

OPEN ONLY NC

OPEN ONLY 10K

PHOTO CLS NCOPEN / CLS NC

GND12VDC OUT

GND

GND

GND

GND

GND

JOG

CLOS

EJO

G OP

EN

TAMP

ER IN

TAMP

ER N

O

GATE

DISA

BLE

KEYP

AD/C

ARD

GND

GND

MAX

OPEN

FIRE

DEP

T

RADI

O GN

DRA

DIO

SIGN

AL

STRI

KE

CLOS

ECO

M

COM

STOP

OPEN

CLS ONLY 10KOPEN / CLS 10K

12VDC OUT

NOCOM

NC

COMGATE CLOSED

LIMIT 1GND

LIMIT 2

MOTOR 1LIMITS

MOTOR 1

MOTOR 2

LIMIT 1GND

LIMIT 2

LIMIT 1LIMIT 2LIMIT 1LIMIT 2

ID PLUGERROR

24VDC OUTPUT

12VDC OUTPUT

GND

GND

GND

LOOPLOOP PWR

LOOP

CENTER

SAFETY

OFF

SINGLE

OPEN

ON/OFFBATTERY

CLOSE

DUAL

ON

ANTI-TAILGATE

PUSHOPEN

PULLOPEN

GATEOFF

123456789

10OFF

123456

MIN MIN

MAX MAX

ON

OFF 2.5 sec1.5 sec

FAULTSOPERATOR

OFF

EXIT LOOP

16MIN

16MIN

3

1

14 12

9

7 3

1

14 12

9

7

UL S

ENSO

R 10

KUL

SEN

SOR

N.C.

MODE

AMO

DE B

PROGRAM

MOTOR 1INPUTS

[+][-]

[+][-]

MOTOR 2INPUTS

MAXIMUM CONTROLSDSP ARM CONTROLLER

Maximum Controls LLC. • 949.699.0220 • 10530 Lawson River Ave, Fountain Valley, CA 92708

MAX ACTUATOR CONTROL BOX Solar Application Guide/Wiring www.max.us.com

Rev April25

LOADBATTERYSOLAR+ - + - + -

Solar Regulator Terminal

Enclosure

NOTE: Cover solar panel from sunlight BEFORE wiring

to prevent a shock from occurring.

NOTE: For more information about solar panel wiring, see your chosen panel’s manual.

Use insulated tools and avoid placing metal objects near the batteries.

Suggested Solar Regulators:Morning Star SunSaver OR Morning Star SunSaver MPPT

Pos + RedNeg - Black

Polarity Matters!

12 Volt

Batteries wired in series

12 Volt

Batteries should be in a

well ventilated enclosure

or overheating will occur

and reduce battery life.

DANGERHAZARDOUS CURRENT

NEVER touch

positive and

negative battery

cables together!

Solar Panel

Connect solar panelto regulator

3

Connect batteries to regulator4Connect solar regulator toPower/ Solar IN DSP ARMCONTROLER

5

Install components in water resistant well ventilated enclosure.Properly Ground Enclosure.

Two 12 V Batteries (24V)Use AGM battery type.

POWER/SOLAR IN

9

7

Pos + RedNeg - Black

ON and OFF Power Supply Switch

Page 11: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

www.max.us.com

PRO SERIES Solar Application Guide/Wiring

The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.

USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.

Select proper solar panel and battery size1

33Ah 33Ahbatteries

50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries

19 20 11 12 4 55020

16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250

5020

100200250

5020

100200250

4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059

166 53 99 19 3925 67 #NUM! 13

68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

173 58 105 24 44169 54 101 21 41166 53 99 19 39131

131

25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS

batteries

batteries batteries batteries batteries

batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)

SWING PRO OPERATORS

33Ah 33Ah50Ah 33Ah 50Ah50Ah

9297

9059

www.max.us.com

PRO SERIES Solar Application Guide/Wiring

The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.

USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.

Select proper solar panel and battery size1

33Ah 33Ahbatteries

50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries

19 20 11 12 4 55020

16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250

5020

100200250

5020

100200250

4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059

166 53 99 19 3925 67 #NUM! 13

68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

173 58 105 24 44169 54 101 21 41166 53 99 19 39131

131

25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS

batteries

batteries batteries batteries batteries

batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)

SWING PRO OPERATORS

33Ah 33Ah50Ah 33Ah 50Ah50Ah

9297

9059

www.max.us.com

PRO SERIES Solar Application Guide/Wiring

The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.

USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.

Select proper solar panel and battery size1

33Ah 33Ahbatteries

50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries

19 20 11 12 4 55020

16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250

5020

100200250

5020

100200250

4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059

166 53 99 19 3925 67 #NUM! 13

68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

173 58 105 24 44169 54 101 21 41166 53 99 19 39131

131

25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS

batteries

batteries batteries batteries batteries

batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

Gate solar cycles per dayZone 1

(6 Hrs Sunlight/Day)Zone 2

(4 Hrs Sunlight/Day)Zone 3

(2 Hrs Sunlight/Day)

60W* Solar Panel NOTE: Must Use 24V

Solar Panel

85W* Solar Panel NOTE: Must Use 24V

Solar Panel

Total System Current

Draw (mA)

5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!

120W* Solar Panel NOTE: Must Use 24V

Solar Panel

MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)

SWING PRO OPERATORS

33Ah 33Ah50Ah 33Ah 50Ah50Ah

9297

9059

SWING, ACTUATORACTUATOR GATE SOLAR CYCLES PER DAY

ZONE 1(6 Hrs Sunlight/Day)

ZONE 2(4 Hrs Sunlight/Day)

ZONE 3(2 Hrs Sunlight/Day)

PANEL SIZETotal System

CurrentDraw (mA)

18AhBATTERIES

18AhBATTERIES

18AhBATTERIES

60 W

26 442.74 438.58 338.38

50 408.16 400.16 296.12

100 336.13 320.13 208.08

200 192.08 160.06 32.01

250 120.05 80.03 -56.02

85 W

26 442.74 438.58 434.41

50 408.16 400.16 392.16

100 336.13 320.13 304.12

200 192.08 160.06 128.05

250 120.05 80.03 40.02

120 W

26 442.74 438.58 434.41

50 408.16 400.16 392.16

100 336.13 320.13 304.12

200 192.08 160.06 128.05

250 120.05 80.03 40.02

200 W

26 442.74 438.58 434.41

50 408.16 400.16 392.16

100 336.13 320.13 304.12

200 192.08 160.06 128.05

250 120.05 80.03 40.02

Page 12: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

LIGHTNINGPROTECTION

The Max Super Arm 2300 offers the most robust lightning protection available in the industry. The Super Arm protects all peripheral inputs, loop inputs, power inputs, relay outputs, and all communication lines (over 35 channels of protection) in 1/1,000,000,000 of a second. With special emphasis on power supply protection, the Max Super Arm 2300 is guaranteed to withstand any lightning hit more than 50 feet away. Truly protected like no other operator in the world.

50 FEET 50 FEET

50 F

EET

50 F

EET

12

Page 13: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

SUPER ARM 2300MAX

WARRANTY2-Year Warranty or 100,000 Cycleswhichever comes first

Maximum Controls LLC Warranty and Return Policy

Section I Coveragea. 2 years or 100,000 cycles whichever comes first on componentsb. 1 year on batteries

Section II Not Covereda. Damages due to floodingb. Damages due to firec. Damages due to negligence i.e. leaving the cover off in the rain, improper wiring of AC or

peripheral systemsd. Damages due to product misuse i.e. gate and operator combination mismatche. Damages due to vandalism

Section III RMA Shipping Policya. Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB

CA on all RMA’s within one year of Distributor’s purchaseb. Any form of “Expedited Shipping” on any RMA will be paid by Distributor

Section IV Product Returnsa Products must be in original, resalable condition with all warranty information, manuals, and

original packaging.b. A re-stock fee of 10% will be charged on all returned products.c. All returned products must reference a Maximum Controls RMA number or it will be refused.d. Maximum Controls is not responsible for freight charges associated with returned

merchandise.

13

Page 14: MAX SUPER ARM 2300€¦ · The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the

Maximum Controls LLC949.699.0220

10530 Lawson River Ave. Fountain Valley CA 92708

USA

Independent Dealer or Distributor

www.Max.US.com

DSP Control

ACcontrol box

MADE IN USA

MAX SUPER ARM 2300MADE IN GERMANY

Rev. OCT-2019


Recommended