MAX SUPER ARM 2300
Moves heavy gates up to 20’High-traffic, High-wind
Self-locking, Mag Lock unnecessaryOverload clutch release on 3-ton impact
DSP Control
2 Year Warranty or 100,000 Cycleswhichever comes first
MAX ACcontrol box
UL 2018 THE NEW STANDARD
MECHANICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
• 24 Volt DC motor • Two independently adjustable closing speed controls with 16 positions each• Switchable 115/230 voltage selection• Adaptive DSP motor control for advanced motion control • Real time performance analyzer and event log (OBD PORT and Black Box)• Magic Box enables low voltage wiring capabilities for remote power up to 1000 ft • On-board switch for solar mode enables 5 milliamp idle in sleep mode• Gold contact input connections and automobile grade connectors• -4F to 165F (-20C to +74C) operational range including battery backup without a heater
• Shipping weight of Actuator: Super Arm (35 lbs)• Shipping weight of AC Control Box (38 lbs)• The patented brake system allows the operator to retract with extreme force. When the force
exceeds 3 tons, the clutch releases upon impact, then automatically resets. Causes for clutch release include a vehicle strike while the gate is in motion.
• Stainless steel output shaft• Direct gear drive (no internal chains, belts, or pulleys)• Mechanical and electrical gate release functions• Continuous duty cycle at extreme temperature range. No overheating• Intelligent ramp-up and ramp-down for smooth gate operation
MAX SUPER ARM 2300 FEATURE LIST:
= Unique to Max Super Arm 2300
7.3”
Min = 37”
4.5”
9.25”
Max = 54.75”
control box13.5” 5.75”
17”JOG GATEOPEN / CLOSE
RESET ALARM
115VAC3A max
7AFUSE
POWER
On
Off
WARNING: For continued protection against fire, replace only with the
same type and rating of fuse.
AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d’incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
Select Input Voltage115VAC or 230VAC
(AC)
POWER IN
115V
SAFETYCENTEREXITJ3
J2
J4 J5
EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORTBLACK BOX
PROGRAMMING
SOLAR MODE
MOTOROVERLOAD
ERDMOTOROVERLOAD MIN MAX
OFF
MAXSENSE
MAXSENSE
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2LIMITS
MAGLOCK
ULENTRAP
STOP CLOSE
CLOSETIMER
MAGLOCKDELAY
JOG
BATTERYTEST
BATTERY
INPUTERROR
BATTERYIN USE
POWER
REPLACEBATTERY LEAVE
CLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEE F1/2
RESET
IDPLUG
MODULEPORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN / CLS NC
GND12VDC OUT
GND
GND
GND
GND
GND
JOG C
LOSE
JOG O
PEN
TAMP
ER IN
TAMP
ER NO
GATE
DISAB
LE
KEYP
AD/CA
RD
GND
GND
MAX O
PEN
FIRE D
EPT
RADIO
GND
RADIO
SIGN
AL
STRIK
E
CLOS
ECO
M
COM
STOP
OPEN
PHOTO CLS 10KOPEN / CLS 10K
12VDC OUT
NOCOM
NC
COMGATE CLOSED
LIMIT 1GND
LIMIT 2
MOTOR 1LIMITS
MOTOR 1
MOTOR 2
LIMIT 1GND
LIMIT 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
ID PLUGERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOPLOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFFBATTERY
CLOSE
DUAL
ON
ANTI-TAILGATE
PUSHOPEN
PULLOPEN
GATEOFF
123456789
10OFF
123456
MIN MIN
MAX MAX
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16MIN
16MIN
3
1
14 12
9
7 3
1
14 12
9
7
UL SE
NSOR
10K
UL SE
NSOR
N.C.
MODE
AMO
DE B
PROGRAM
MOTOR 1INPUTS
[+][-]
[+][-]
MOTOR 2INPUTS
MAXIMUM CONTROLSDSP ARM CONTROLLER
8ft 12ft 16ft 20ft
2300
lbs
2000
lbs
1800
lbs
1500
lbs
Max Weight/Length
7.3”
Min = 37”
4.5”
9.25”
Max = 54.75”
control box13.5” 5.75”
17”JOG GATEOPEN / CLOSE
RESET ALARM
115VAC3A max
7AFUSE
POWER
On
Off
WARNING: For continued protection against fire, replace only with the
same type and rating of fuse.
AVERTISSEMENT: pour ne pas compromettre la protection contre les risques d’incendie, utiliser un
fusible de mêmes type et caractéristiques nominales.
Select Input Voltage115VAC or 230VAC
(AC)
POWER IN
115V
SAFETYCENTEREXITJ3
J2
J4 J5
EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORTBLACK BOX
PROGRAMMING
SOLAR MODE
MOTOROVERLOAD
ERDMOTOROVERLOAD MIN MAX
OFF
MAXSENSE
MAXSENSE
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2LIMITS
MAGLOCK
ULENTRAP
STOP CLOSE
CLOSETIMER
MAGLOCKDELAY
JOG
BATTERYTEST
BATTERY
INPUTERROR
BATTERYIN USE
POWER
REPLACEBATTERY LEAVE
CLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEE F1/2
RESET
IDPLUG
MODULEPORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN / CLS NC
GND12VDC OUT
GND
GND
GND
GND
GND
JOG C
LOSE
JOG O
PEN
TAMP
ER IN
TAMP
ER NO
GATE
DISAB
LE
KEYP
AD/CA
RD
GND
GND
MAX O
PEN
FIRE D
EPT
RADIO
GND
RADIO
SIGN
AL
STRIK
E
CLOS
ECO
M
COM
STOP
OPEN
PHOTO CLS 10KOPEN / CLS 10K
12VDC OUT
NOCOM
NC
COMGATE CLOSED
LIMIT 1GND
LIMIT 2
MOTOR 1LIMITS
MOTOR 1
MOTOR 2
LIMIT 1GND
LIMIT 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
ID PLUGERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOPLOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFFBATTERY
CLOSE
DUAL
ON
ANTI-TAILGATE
PUSHOPEN
PULLOPEN
GATEOFF
123456789
10OFF
123456
MIN MIN
MAX MAX
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16MIN
16MIN
3
1
14 12
9
7 3
1
14 12
9
7
UL SE
NSOR
10K
UL SE
NSOR
N.C.
MODE
AMO
DE B
PROGRAM
MOTOR 1INPUTS
[+][-]
[+][-]
MOTOR 2INPUTS
MAXIMUM CONTROLSDSP ARM CONTROLLER
8ft 12ft 16ft 20ft
2300
lbs
2000
lbs
1800
lbs
1500
lbs
Max Weight/Length
Gate Capacity
2
SAFETY SPECIFICATIONS
• UL 325/991 compliant Class I, II, III, and IV. CSA approved• Vehicle hit protection technology protects the gate operator from collision damage caused by
automobile impact, avoiding costly repairs• Built in advanced entrapment protection and alarm output• Built in gate-in-motion alarm for industrial applications
• Robust lightning protection, up to 20KVolts and 10KAmps on all inputs and outputs (35 channels) including loop detector input connections
• Two selectable 16 position safety obstruction sensors, auto adaptable to gate weight and size, for independent control of open and close cycles
• Independent closing speeds for primary and secondary• Dual motor overcurrent safety shut off for additional protection• Two 7amp hour batteries provide 500 cycles in case of power failure with three modes of battery
backup, open once, leave open or leave closed• On-board three button station• On-board UL reset button
= Unique to Max Super Arm 2300
SECURITY SPECIFICATIONS
• High traffic intuitive loop management system for exceptional security• Advanced security features with built-in audible and remote alarms • Magnetic lock control relay outputs with selectable delay times• Tamper alert relay output triggers “on” if gate is forced open• Audible alarm if gate is tampered with or ERD is triggered for heightened security• Steel cover with lock protects against intruders and vandalism• Gate disable feature disables all inputs with exception of the fire department and Max Open input
for increased security • Built in transaction buffer• Gate status outputs for gate monitoring• Key activated jog function for emergency OPEN/CLOSE function• Advanced anti-tailgate feature prevents unwanted intrusion
3
The Max Super Arm 2300 has a solid stainless steel output shaft and key lock for mechanical release. For emergency release unlock the key and lift up the hood. To engage the actuator, push down the hood and lock to resume automatic operation.
The Max Super Arm 2300 ships with a heavy duty half inch stock rear bracket that is broached and welded. Both brackets front and rear, are silver zinc plated.
Front BracketRear Bracket
SUPER ARM 2300 MECHANICAL RELEASE
AND MOUNTING BRAKETS
4
Maximum Controls recognizes swing gates are more prone to vehicular collisions. For this reason, the Max Super Arm 2300 will collapse on impact when struck by vehicular traffic. When a vehicle hits a moving gate, to avoid damage to the actuators, the Super Arm 2300 reset automatically.
VEHICLE HIT PROTECTION
PUSH OPEN
PULL OPENINSIDE PROPERTY
OUTSIDE PROPERTY
TWO INSTALLATION OPTIONS
OPEN
OPEN
CLOSED
CLOSED
5
90° Open 75° Open
90° Open 75° Open
90° Open 75° Open
90° Open 75° Open
Opening one 90° and the other is 75°
with the independent closing speeds adjusted the closing gate leaves can be synced
ASYMMETRIC SPEED CONTROL
For asymmetric installations the two independent closing speeds can be adjusted to achieve a smooth closing sync. Whichever gate closes first, slow it down. This enables the installer to visually sync the closing cycle. This feature is unique to Maximum Control’s actuators.
6
AC CONTROL BOX
Two 12V 7 AGM Batteries
UL Reset Button
Jog Open/CloseKey Switch for emergency access to property
Selectable Switch115V or 230V AC
7 ampFuse
ON and OFF Power Supply Switch
Two plugin power outlets
Loop RackSafety LoopCenter LoopExit Loop
Steel housing2- layer protection
Gold zinc Electrostatic
powder coating
Gold plated automobile connectorsthroughout the system
Control Panel
The AC Control Box features rugged metal construction that is gold zinc plated and powder coated. Each AC Control Box comes with an exterior UL reset button, a convenient jog key switch for emergency access or egress, a 10 amp power supply with two 115 VAC accessory outlets, two 7 amp batteries conveniently located behind the control panel, a loop rack and much more. A lockable steel cover finishes off this slick design.
A convenient LCD display keeps you informed. Functional data and error messages are visible when an accessory failure or function is present. This makes troubleshooting and monitoring a breeze.
These many features can be explored in our downloadable installation manual available on max.us.com
7
MAX SOLAR CONTROL BOX
Two 12V 18 Agm Batteries
UL Reset Button
Jog Switch inputOPTIONAL
ON and OFF Power Supply Switch
30AFUSE
Loop RackOPTIONAL
Steel housing2-layer protection
Gold zinc Electrostatic
powder coating
Gold plated automobile connectors
through the system
Control Panel
Solar Regulator24V, 20A
(MORNING STAR)
Solar Regulator24V, 20A(MORNING STAR)
8
1. Battery Input2. Power/Solar Input3. Module Port4. Reset
5. UL Alarm6. ID Plug7. Loop Rack Input8. 12VDC & 24VDC Limited Current Power Output
1. Battery Backup Mode Switch 2. Battery Test Switch3. ERD Sensitivity4. OBD Port5. DIP Switches6. Program Button7. Loop Status
8. Solar Mode Application9. Motion Control Buttons
10. Maglock Delay11. LCD Display12. Close Timer Switch13. Jog Open/Close14. Closing Gate Speed
87653 421
CONTROL FEATURES AND CONNECTIONS
12
113
4
5
6
7
8
9
12
10
14
13
9
MAX SOLAR CONTROL BOX
Two 12V 18 AH (AGM Rechargable Batteries)
UL Reset Button
Jog SwitchOPTIONAL
30AFUSE
Loop RackOPTIONAL
Steel housing2-layer protection
Gold zinc Electrostatic
powder coating
Gold plated automobile connectors
through the system
SOLAR MODESwitch to enable low power draw for solar mode
Control Panel
Solar Regulator24V, 10A
(MORNING STAR)
Solar Regulator24V, 10A(MORNING STAR)
24V Solar PanelOutput: 36 V (Max) - Open Circuit
Wire solar panel terminals to solar regulator inputCaution: polarity matters EXIT PWR
ALARM
POWER /SOLAR IN
BATTERYINPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORTBLACK BOX
PROGRAMMING
SOLAR MODE
MOTOROVERLOAD
ERD
MOTOROVERLOAD MIN MAX
OFF
MAXSENSE
MAXSENSE
BATTERYBACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2LIMITS
MAGLOCK
ULENTRAP
STOP CLOSE
CLOSETIMER
MAGLOCKDELAY
JOG
BATTERYTEST
BATTERY
INPUTERROR
BATTERYIN USE
POWER
REPLACEBATTERY
LEAVECLOSED
LEAVEOPEN
OPEN1 TIME
BATTERY VOLTAGEF1/2E
RESET
IDPLUG
MODULEPORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NCOPEN / CLS NC
GND12VDC OUT
GND
GND
GND
GND
GND
JOG
CLOS
EJO
G OP
EN
TAMP
ER IN
TAMP
ER N
O
GATE
DISA
BLE
KEYP
AD/C
ARD
GND
GND
MAX
OPEN
FIRE
DEP
T
RADI
O GN
DRA
DIO
SIGN
AL
STRI
KE
CLOS
ECO
M
COM
STOP
OPEN
CLS ONLY 10KOPEN / CLS 10K
12VDC OUT
NOCOM
NC
COMGATE CLOSED
LIMIT 1GND
LIMIT 2
MOTOR 1LIMITS
MOTOR 1
MOTOR 2
LIMIT 1GND
LIMIT 2
LIMIT 1LIMIT 2LIMIT 1LIMIT 2
ID PLUGERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOPLOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFFBATTERY
CLOSE
DUAL
ON
ANTI-TAILGATE
PUSHOPEN
PULLOPEN
GATEOFF
123456789
10OFF
123456
MIN MIN
MAX MAX
ON
OFF 2.5 sec1.5 sec
FAULTSOPERATOR
OFF
EXIT LOOP
16MIN
16MIN
3
1
14 12
9
7 3
1
14 12
9
7
UL S
ENSO
R 10
KUL
SEN
SOR
N.C.
MODE
AMO
DE B
PROGRAM
MOTOR 1INPUTS
[+][-]
[+][-]
MOTOR 2INPUTS
MAXIMUM CONTROLSDSP ARM CONTROLLER
Maximum Controls LLC. • 949.699.0220 • 10530 Lawson River Ave, Fountain Valley, CA 92708
MAX ACTUATOR CONTROL BOX Solar Application Guide/Wiring www.max.us.com
Rev April25
LOADBATTERYSOLAR+ - + - + -
Solar Regulator Terminal
Enclosure
NOTE: Cover solar panel from sunlight BEFORE wiring
to prevent a shock from occurring.
NOTE: For more information about solar panel wiring, see your chosen panel’s manual.
Use insulated tools and avoid placing metal objects near the batteries.
Suggested Solar Regulators:Morning Star SunSaver OR Morning Star SunSaver MPPT
Pos + RedNeg - Black
Polarity Matters!
12 Volt
Batteries wired in series
12 Volt
Batteries should be in a
well ventilated enclosure
or overheating will occur
and reduce battery life.
DANGERHAZARDOUS CURRENT
NEVER touch
positive and
negative battery
cables together!
Solar Panel
Connect solar panelto regulator
3
Connect batteries to regulator4Connect solar regulator toPower/ Solar IN DSP ARMCONTROLER
5
Install components in water resistant well ventilated enclosure.Properly Ground Enclosure.
Two 12 V Batteries (24V)Use AGM battery type.
POWER/SOLAR IN
9
7
Pos + RedNeg - Black
ON and OFF Power Supply Switch
www.max.us.com
PRO SERIES Solar Application Guide/Wiring
The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.
USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.
Select proper solar panel and battery size1
33Ah 33Ahbatteries
50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries
19 20 11 12 4 55020
16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250
5020
100200250
5020
100200250
4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059
166 53 99 19 3925 67 #NUM! 13
68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
173 58 105 24 44169 54 101 21 41166 53 99 19 39131
131
25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS
batteries
batteries batteries batteries batteries
batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)
SWING PRO OPERATORS
33Ah 33Ah50Ah 33Ah 50Ah50Ah
9297
9059
www.max.us.com
PRO SERIES Solar Application Guide/Wiring
The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.
USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.
Select proper solar panel and battery size1
33Ah 33Ahbatteries
50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries
19 20 11 12 4 55020
16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250
5020
100200250
5020
100200250
4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059
166 53 99 19 3925 67 #NUM! 13
68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
173 58 105 24 44169 54 101 21 41166 53 99 19 39131
131
25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS
batteries
batteries batteries batteries batteries
batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)
SWING PRO OPERATORS
33Ah 33Ah50Ah 33Ah 50Ah50Ah
9297
9059
www.max.us.com
PRO SERIES Solar Application Guide/Wiring
The map and daily cycle rate shown are approximations based upon the average solar radiation and the temperature effects on batteries in the given regions. Local geography and weather conditions may require additional solar panels.
USE LOW POWER accessories in order to minimize power draw. Each additional accessory draws power affecting the daily cycle rate.
Select proper solar panel and battery size1
33Ah 33Ahbatteries
50Ah 33Ah 50Ah50Ah batteries batteries batteries batteries batteries
19 20 11 12 4 55020
16 17 8 9 2 2100 14 16 7 8 1 1200 9 10 2 3 #NUM! #NUM!250
5020
100200250
5020
100200250
4 5 #NUM! #NUM! #NUM! #NUM!97 173 58 105 24 4492 169 54 101 21 419059
166 53 99 19 3925 67 #NUM! 13
68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
173 58 105 24 44169 54 101 21 41166 53 99 19 39131
131
25 67 #NUM! 1368 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROGATE WEIGHT LESS THAN 1000 LBS
batteries
batteries batteries batteries batteries
batteries5 19 20 11 12 4 515 16 17 8 9 2 220 14 16 7 8 1 140 9 10 2 3 #NUM! #NUM!60 4 5 #NUM! #NUM! #NUM! #NUM!5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
Gate solar cycles per dayZone 1
(6 Hrs Sunlight/Day)Zone 2
(4 Hrs Sunlight/Day)Zone 3
(2 Hrs Sunlight/Day)
60W* Solar Panel NOTE: Must Use 24V
Solar Panel
85W* Solar Panel NOTE: Must Use 24V
Solar Panel
Total System Current
Draw (mA)
5 97 173 58 105 24 4415 92 169 54 101 21 4120 90 166 53 99 19 39100 59 131 25 67 #NUM! 13250 9 68 #NUM! 14 #NUM! #NUM!
120W* Solar Panel NOTE: Must Use 24V
Solar Panel
MEGATRON PROHEAVY GATE WEIGHT GREATER THAN 1000 LBS (LESS THAN MAX WEIGHT)
SWING PRO OPERATORS
33Ah 33Ah50Ah 33Ah 50Ah50Ah
9297
9059
SWING, ACTUATORACTUATOR GATE SOLAR CYCLES PER DAY
ZONE 1(6 Hrs Sunlight/Day)
ZONE 2(4 Hrs Sunlight/Day)
ZONE 3(2 Hrs Sunlight/Day)
PANEL SIZETotal System
CurrentDraw (mA)
18AhBATTERIES
18AhBATTERIES
18AhBATTERIES
60 W
26 442.74 438.58 338.38
50 408.16 400.16 296.12
100 336.13 320.13 208.08
200 192.08 160.06 32.01
250 120.05 80.03 -56.02
85 W
26 442.74 438.58 434.41
50 408.16 400.16 392.16
100 336.13 320.13 304.12
200 192.08 160.06 128.05
250 120.05 80.03 40.02
120 W
26 442.74 438.58 434.41
50 408.16 400.16 392.16
100 336.13 320.13 304.12
200 192.08 160.06 128.05
250 120.05 80.03 40.02
200 W
26 442.74 438.58 434.41
50 408.16 400.16 392.16
100 336.13 320.13 304.12
200 192.08 160.06 128.05
250 120.05 80.03 40.02
LIGHTNINGPROTECTION
The Max Super Arm 2300 offers the most robust lightning protection available in the industry. The Super Arm protects all peripheral inputs, loop inputs, power inputs, relay outputs, and all communication lines (over 35 channels of protection) in 1/1,000,000,000 of a second. With special emphasis on power supply protection, the Max Super Arm 2300 is guaranteed to withstand any lightning hit more than 50 feet away. Truly protected like no other operator in the world.
50 FEET 50 FEET
50 F
EET
50 F
EET
12
SUPER ARM 2300MAX
WARRANTY2-Year Warranty or 100,000 Cycleswhichever comes first
Maximum Controls LLC Warranty and Return Policy
Section I Coveragea. 2 years or 100,000 cycles whichever comes first on componentsb. 1 year on batteries
Section II Not Covereda. Damages due to floodingb. Damages due to firec. Damages due to negligence i.e. leaving the cover off in the rain, improper wiring of AC or
peripheral systemsd. Damages due to product misuse i.e. gate and operator combination mismatche. Damages due to vandalism
Section III RMA Shipping Policya. Maximum Controls LLC will pay for return shipping via standard ground UPS or USPS FOB
CA on all RMA’s within one year of Distributor’s purchaseb. Any form of “Expedited Shipping” on any RMA will be paid by Distributor
Section IV Product Returnsa Products must be in original, resalable condition with all warranty information, manuals, and
original packaging.b. A re-stock fee of 10% will be charged on all returned products.c. All returned products must reference a Maximum Controls RMA number or it will be refused.d. Maximum Controls is not responsible for freight charges associated with returned
merchandise.
13
Maximum Controls LLC949.699.0220
10530 Lawson River Ave. Fountain Valley CA 92708
USA
Independent Dealer or Distributor
www.Max.US.com
DSP Control
ACcontrol box
MADE IN USA
MAX SUPER ARM 2300MADE IN GERMANY
Rev. OCT-2019