Page 1: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

M&B TM

1998 Ford Escort

Page 2: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

Ford ECT

ECT

Page 3: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

ECT

Page 4: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOEOECT Disconnected

ECT Voltage= 4.75VECT Temperature= 61F

Page 5: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOEOJumper Across ECTECT Voltage= .01V

ECT Temperature= 61F

Page 6: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOER At Operating TemperatureECT Voltage= .66V

ECT Temperature= 192F

Page 7: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOER At Operating TemperatureECT Disconnected- car still running

ECT Voltage= 4.75VECT Temperature= 199F and climbing

Cooling Fan On as soon as ECT was Disconnected

Page 8: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOER At Operating TemperatureJumper Across ECT- car still running

ECT Voltage= .01VECT Temperature= 210 and climbing

Cooling Fan on as soon as ECT was Jumped

Page 9: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOEO at Operating TemperatureECT Disconnected until Max Temperature was achieved

ECT Temperature stopped at 219F

Page 10: M&B TM 1998 Ford Escort. Ford ECT ECT KOEO ECT Disconnected ECT Voltage= 4.75V ECT Temperature= 61F.

KOER at Operating TemperatureECT Plugged Back In

Cooling Fan Switched OffECT Voltage= .73V

ECT Temperature= 183F