M&B TM
1998 Ford Escort
Ford ECT
ECT
ECT
KOEOECT Disconnected
ECT Voltage= 4.75VECT Temperature= 61F
KOEOJumper Across ECTECT Voltage= .01V
ECT Temperature= 61F
KOER At Operating TemperatureECT Voltage= .66V
ECT Temperature= 192F
KOER At Operating TemperatureECT Disconnected- car still running
ECT Voltage= 4.75VECT Temperature= 199F and climbing
Cooling Fan On as soon as ECT was Disconnected
KOER At Operating TemperatureJumper Across ECT- car still running
ECT Voltage= .01VECT Temperature= 210 and climbing
Cooling Fan on as soon as ECT was Jumped
KOEO at Operating TemperatureECT Disconnected until Max Temperature was achieved
ECT Temperature stopped at 219F
KOER at Operating TemperatureECT Plugged Back In
Cooling Fan Switched OffECT Voltage= .73V
ECT Temperature= 183F